73 resultados para THROMBECTOMY


Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION Diagnostic tools to show emboli reliably and protection techniques against embolization when employing stent retrievers are necessary to improve endovascular stroke therapy. The aim of the present study was to investigate iatrogenic emboli using susceptibility-weighted imaging (SWI) in an open series of patients who had been treated with stent retriever thrombectomy using emboli protection techniques. METHODS Patients with anterior circulation stroke examined with MRI before and after stent retriever thrombectomy were assessed for iatrogenic embolic events. Thrombectomy was performed in flow arrest and under aspiration using a balloon-mounted guiding catheter, a distal access catheter, or both. RESULTS In 13 of 57 patients (22.8 %) post-interventional SWI sequences detected 16 microemboli. Three of them were associated with small ischemic lesions on diffusion-weighted imaging (DWI). None of the microemboli were located in a new vascular territory, none showed clinical signs, and all 13 patients have been rated as Thrombolysis in Cerebral Infarction (TICI) 2b (n = 3) or 3 (n = 10). Retrospective reevaluation of the digital subtraction angiography (DSA) detected discrete flow stagnation nearby the iatrogenic microemboli in four patients with a positive persistent collateral sign in one. CONCLUSION Our study demonstrates two things: First, SWI seems to be more sensitive to detect emboli than DWI and DSA and, second, proximal or distal protected stent retriever thrombectomy seems to prevent iatrogenic embolization into new vascular territories during retraction of the thrombus, but not downstream during mobilization of the thrombus. Both techniques should be investigated and refined further.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Clinical trials have shown a beneficial effect of mechanical thrombectomy in acute ischemic stroke patients treated within six up to even 12 h after symptom onset. This treatment was already performed in selected hospitals in Belgium before completion of the randomized controlled trials. Outcome data on these procedures in Belgium have not been published. We performed a retrospective multicenter study of all patients with acute ischemic stroke treated with mechanical endovascular therapy in four hospitals in Belgium. Clinical outcomes, as measured by the modified Rankin Scale (mRS), site of arterial occlusion, reperfusion and the association between these variables were studied. The study included 80 patients: 65 patients with an occlusion in the anterior circulation and 15 with an occlusion in the posterior circulation. Good functional outcome (GFO) rates, defined as mRS 0-2 at 90 days, were 42 % in all patients, 44 % in anterior circulation stroke and 34 % in posterior circulation stroke. Reperfusion was achieved in 78 % of patients; more (100 %) in patients with posterior compared to patients with anterior circulation stroke (72 %; p = 0.02). The rate of GFO was greater in patients with reperfusion versus patients in whom reperfusion was not achieved (adjusted OR 8.2, 95 % CI 2.0-34.2). Symptomatic intracerebral hemorrhage was documented in 5 % of all patients. Endovascular treatment with mechanical devices for acute ischemic stroke in Belgium results in GFO and reperfusion rates similar to recently published results in the endovascular-treated arms of randomized clinical trials. Rates of symptomatic intracranial hemorrhage are low and comparable to other cohort studies and clinical trials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE Mechanical thrombectomy is beneficial for patients with acute ischemic stroke and a proximal anterior occlusion, but it is unclear if these results can be extrapolated to patients with an M2 occlusion. The purpose of this study was to examine the technical aspects, safety, and outcomes of mechanical thrombectomy with a stent retriever in patients with an isolated M2 occlusion who were included in 3 large multicenter prospective studies. MATERIALS AND METHODS We included patients from the Solitaire Flow Restoration Thrombectomy for Acute Revascularization (STAR), Solitaire With the Intention For Thrombectomy (SWIFT), and Solitaire With the Intention for Thrombectomy as Primary Endovascular Treatment (SWIFT PRIME) studies, 3 large multicenter prospective studies on thrombectomy for ischemic stroke. We compared outcomes and technical details of patients with an M2 with those with an M1 occlusion. All patients were treated with a stent retriever. Imaging data and outcomes were scored by an independent core laboratory. Successful reperfusion was defined as modified Thrombolysis in Cerebral Infarction score of 2b/3. RESULTS We included 50 patients with an M2 and 249 patients with an M1 occlusion. Patients with an M2 occlusion were older (mean age, 71 versus 67 years; P = .04) and had a lower NIHSS score (median, 13 versus 17; P < .001) compared with those with an M1 occlusion. Procedural time was nonsignificantly shorter in patients with an M2 occlusion (median, 29 versus 35 minutes; P = .41). The average number of passes with a stent retriever was also nonsignificantly lower in patients with an M2 occlusion (mean, 1.4 versus 1.7; P = .07). There were no significant differences in successful reperfusion (85% versus 82%, P = .82), symptomatic intracerebral hemorrhages (2% versus 2%, P = 1.0), device-related serious adverse events (6% versus 4%, P = .46), or modified Rankin Scale score 0-2 at follow-up (60% versus 56%, P = .64). CONCLUSIONS Endovascular reperfusion therapy appears to be feasible in selected patients with ischemic stroke and an M2 occlusion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several recent prospective randomized controlled trials of endovascular stroke therapy using latest generation thrombectomy devices, so called stent-retrievers, have shown significantly improved clinical outcome compared to the standard treatment with intra-venous thrombolysis using r-tPA alone. Despite some differences in inclusion criteria between these studies, all required non-invasive vessel imaging to proof occlusion of a major brain supplying vessel. Furthermore, in most studies additional imaging techniques were used to exclude patients with already established large cerebral infarction or unfavorable collateral or penumbral status. Patients with small infarct volume, severe neurological deficits and in whom thrombectomy can be initiated within the first 6 hours after symptom onset seem to benefit the most. Therefore, mechanical thrombectomy using stent-retrievers in addition to intra-venous thrombolysis is recommended for the treatment of acute ischemic stroke with proven major vessel occlusion in the anterior circulation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The original version of this consensus statement on mechanical thrombectomy was approved at the European Stroke Organisation (ESO)-Karolinska Stroke Update conference in Stockholm, 16-18 November 2014. The statement has later, during 2015, been updated with new clinical trials data in accordance with a decision made at the conference. Revisions have been made at a face-to-face meeting during the ESO Winter School in Berne in February, through email exchanges and the final version has then been approved by each society. The recommendations are identical to the original version with evidence level upgraded by 20 February 2015 and confirmed by 15 May 2015. The purpose of the ESO-Karolinska Stroke Update meetings is to provide updates on recent stroke therapy research and to discuss how the results may be implemented into clinical routine. Selected topics are discussed at consensus sessions, for which a consensus statement is prepared and discussed by the participants at the meeting. The statements are advisory to the ESO guidelines committee. This consensus statement includes recommendations on mechanical thrombectomy after acute stroke. The statement is supported by ESO, European Society of Minimally Invasive Neurological Therapy (ESMINT), European Society of Neuroradiology (ESNR), and European Academy of Neurology (EAN).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A number of thrombectomy devices using a variety of methods have now been developed to facilitate clot removal. We present research involving one such experimental device recently developed in the UK, called a ‘GP’ Thrombus Aspiration Device (GPTAD). This device has the potential to bring about the extraction of a thrombus. Although the device is at a relatively early stage of development, the results look encouraging. In this work, we present an analysis and modeling of the GPTAD by means of the bond graph technique; it seems to be a highly effective method of simulating the device under a variety of conditions. Such modeling is useful in optimizing the GPTAD and predicting the result of clot extraction. The aim of this simulation model is to obtain the minimum pressure necessary to extract the clot and to verify that both the pressure and the time required to complete the clot extraction are realistic for use in clinical situations, and are consistent with any experimentally obtained data. We therefore consider aspects of rheology and mechanics in our modeling.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: In this work, we present the analysis, design and optimization of one experimental device recently developed in the UK, called the 'GP' Thrombus Aspiration Device (GPTAD). This device has been designed to remove blood clots without the need to make contact with the clot itself thereby potentially reducing the risk of problems such as downstream embolisation. Method: To obtain the minimum pressure necessary to extract the clot and to optimize the device, we have simulated the performance of the GPTAD analysing the resistances, compliances and inertances effects. We model a range of diameters for the GPTAD considering different forces of adhesion of the blood clot to the artery wall, and different lengths of blood clot. In each case we determine the optimum pressure required to extract the blood clot from the artery using the GPTAD, which is attached at its proximal end to a suction pump. Result: We then compare the results of our mathematical modelling to measurements made in laboratory using plastic tube models of arteries of comparable diameter. We use abattoir porcine blood clots that are extracted using the GPTAD. The suction pressures required for such clot extraction in the plastic tube models compare favourably with those predicted by the mathematical modelling. Discussion & Conclusion: We conclude therefore that the mathematical modelling is a useful technique in predicting the performance of the GPTAD and may potentially be used in optimising the design of the device.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recently, we have presented some studies concerning the analysis, design and optimization of one experimental device developed in the UK - GPTAD - which has been designed to remove blood clots without the need to make contact with the clot itself, thereby potentially reducing the risk of problems such as downstream embolisation. Based on the idea of a modification of the previous device, in this work, we present a model based in the use of stents like the SolitaireTM FR, which is in contact with the clot itself. In the case of such devices, the stent is self-expandable and the extraction of the blood clot is faciliatated by the stent, which must be inside the clot. Such stents are generally inserted in position by using the guidewire inserted into the catheter. This type of modeling could potentially be useful in showing how the blood clot is moved by the various different forces involved. The modelling has been undertaken by analyzing the resistances, compliances and inertances effects. We model an artery and blood clot for range of forces for the guidewire. In each case we determine the interaction between blood clot, stent and artery.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The decrease in the number of cadaveric donors has proved a limiting factor in the number of liver transplants, leading to the death of many patients on the waiting list. The living donor liver transplantation is an option that allows, in selected cases, increase the number of donors. One of the most serious complications in liver transplantation is hepatic artery thrombosis, in the past considered potentially fatal without urgent re-transplantation. A white male patient, 48 years old, diagnosed with hepatocellular carcinoma in chronic liver failure caused by hepatitis B virus, underwent living donor liver transplantation (right lobe). Doppler echocardiography performed in the immediate postoperative period did not identify arterial flow in the right branch, having been confirmed thrombosis of the right hepatic artery in CT angiography. Urgent re-laparotomy was performed, which consisted of thrombectomy and re-anastomosis of the hepatic artery with segmental splenic artery allograft interposition. The patient started anticoagulation and antiplatelet therapy with acetylsalicylic acid. Serial evaluation with Doppler echocardiography showed hepatic artery patency. At present, the patient is asymptomatic. One of the most devastating complications in liver transplantation, and particularly in living liver donor, is thrombosis of the hepatic artery; thus, early diagnosis and treatment is vital. The rapid intervention for revascularization of the graft avoids irreversible ischemia of the bile ducts and hepatic parenchyma, thus avoiding the need for re-transplantation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Treatment strategies for acute basilar artery occlusion (BAO) are based on case series and data that have been extrapolated from stroke intervention trials in other cerebrovascular territories, and information on the efficacy of different treatments in unselected patients with BAO is scarce. We therefore assessed outcomes and differences in treatment response after BAO. METHODS: The Basilar Artery International Cooperation Study (BASICS) is a prospective, observational registry of consecutive patients who presented with an acute symptomatic and radiologically confirmed BAO between November 1, 2002, and October 1, 2007. Stroke severity at time of treatment was dichotomised as severe (coma, locked-in state, or tetraplegia) or mild to moderate (any deficit that was less than severe). Outcome was assessed at 1 month. Poor outcome was defined as a modified Rankin scale score of 4 or 5, or death. Patients were divided into three groups according to the treatment they received: antithrombotic treatment only (AT), which comprised antiplatelet drugs or systemic anticoagulation; primary intravenous thrombolysis (IVT), including subsequent intra-arterial thrombolysis; or intra-arterial therapy (IAT), which comprised thrombolysis, mechanical thrombectomy, stenting, or a combination of these approaches. Risk ratios (RR) for treatment effects were adjusted for age, the severity of neurological deficits at the time of treatment, time to treatment, prodromal minor stroke, location of the occlusion, and diabetes. FINDINGS: 619 patients were entered in the registry. 27 patients were excluded from the analyses because they did not receive AT, IVT, or IAT, and all had a poor outcome. Of the 592 patients who were analysed, 183 were treated with only AT, 121 with IVT, and 288 with IAT. Overall, 402 (68%) of the analysed patients had a poor outcome. No statistically significant superiority was found for any treatment strategy. Compared with outcome after AT, patients with a mild-to-moderate deficit (n=245) had about the same risk of poor outcome after IVT (adjusted RR 0.94, 95% CI 0.60-1.45) or after IAT (adjusted RR 1.29, 0.97-1.72) but had a worse outcome after IAT compared with IVT (adjusted RR 1.49, 1.00-2.23). Compared with AT, patients with a severe deficit (n=347) had a lower risk of poor outcome after IVT (adjusted RR 0.88, 0.76-1.01) or IAT (adjusted RR 0.94, 0.86-1.02), whereas outcomes were similar after treatment with IAT or IVT (adjusted RR 1.06, 0.91-1.22). INTERPRETATION: Most patients in the BASICS registry received IAT. Our results do not support unequivocal superiority of IAT over IVT, and the efficacy of IAT versus IVT in patients with an acute BAO needs to be assessed in a randomised controlled trial. FUNDING: Department of Neurology, University Medical Center Utrecht.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: The effects of intravenous thrombolysis on floating thrombi in cervical and intracranial arteries of acute ischemic stroke patients are unknown. Similarly, the best prevention methods of early recurrences remain controversial. This study aimed to describe the clinical and radiological outcome of thrombolyzed strokes with floating thrombi. METHODS: We retrospectively analyzed all thrombolyzed stroke patients in our institution between 2003 and 2010 with floating thrombi on acute CT-angiography before the intravenous thrombolysis. The floating thrombus was diagnosed if an elongated thrombus of at least 5 mm length, completely surrounded by contrast on supra-aortic neck or intracerebral arteries, was present on CT-angiography. Demographics, vascular risk factors, and comorbidities were recorded and stroke etiology was determined after a standardized workup. Repeat arterial imaging was performed by CTA at 24 h or before if clinical worsening was noted and then by Doppler and MRA during the first week and at four months. RESULTS: Of 409 thrombolyzed stroke patients undergoing acute CT Angiography, seven (1.7%) had a floating thrombus; of these seven, six had it in the anterior circulation. Demographics, risk factors and stroke severity of these patients were comparable to the other thrombolyzed patients. After intravenous thrombolysis, the floating thrombi resolved completely at 24 h in four of the patients, whereas one had an early recurrent stroke and one developed progressive worsening. One patient developed early occlusion of the carotid artery with floating thrombus and subsequently a TIA. The two patients with a stable floating thrombus had no clinical recurrences. In the literature, only one of four reported cases were found to have a thrombolysis-related early recurrence. CONCLUSIONS: Long-term outcome seemed similar in thrombolyzed patients with floating thrombus, despite a possible increase of very early recurrence. It remains to be established whether acute mechanical thrombectomy could be a safer and more effective treatment to prevent early recurrence. However, intravenous thrombolysis should not be withheld in eligible stroke patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Early reperfusion with prompt re-establishment of coronary blood flow improves survival in patients suffering from acute ST-elevation myocardial infarction (STEMI). Leaving systemic thrombolysis for primary percutaneous coronary intervention (PCI) is justified by clinical results in favor of PCI. Nevertheless, primary PCI necessitates additional transfer time and requires an efficient territorial networking. The present article summarizes the up-to-dated management of patients with acute STEMI and/or overt cardiogenic shock.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: To compare safety and efficacy of bridging approach with intravenous (IV) thrombolysis in patients with acute anterior strokes and proximal occlusions. PATIENTS AND METHODS: Consecutive patients with ischemic anterior strokes admitted within a 4 h 30 min window in two different centers were included. The first center performed IV therapy (alteplase 0.6 mg/kg) during 30 min and, in absence of clinical improvement, mechanical thrombectomy with flow restoration using a Solitaire stent (StS); the second carried out IV thrombolysis (alteplase 0.9 mg/kg) alone. Only T, M1 or M2 occlusions present on CT angiography were considered. Endpoints were clinical outcome and mortality at 3 months. RESULTS: There were 63 patients in the bridging and 163 in the IV group. No significant differences regarding baseline characteristics were observed. At 3 months, 46% (n = 29) of the patients treated in the combined and 23% (n = 38) of those treated in the IV group had a modified Rankin scale (mRS) of 0-1 (P < 0.001). A statistical significant difference was observed for all sites of occlusion. In a logistic regression model, National Institute of Health Stroke Scale (NIHSS) and bridging therapy were independent predictors of good outcome (respectively, P = 0.001 and P = 0.0018). Symptomatic hemorrhage was documented in 6.3% vs 3.7% in the bridging and in the IV group, respectively (P = 0.32). There was no difference in mortality. CONCLUSIONS: Our results suggest that patients treated with a bridging approach were more likely to have minimal or no deficit at all at 3 months as compared to the IV treated group.