969 resultados para THICK DISC
Resumo:
Purpose: To investigate the effects of intrapulpal temperature changes induced by a quartz tungsten halogen (QTH) and a light emitting diode (LED) curing units on the metabolism of odontoblast-like cells. Methods: Thirty-six 0.5 mm-thick dentin discs obtained from sound human teeth were randomly assigned into three groups: QTH, LED and no light (control). After placement of the dentin discs in pulp chamber devices, a thermistor was attached to the pulpal surface of each disc and the light sources were applied on the occlusal surface. After registering the temperature change, odontoblast-like cells MDPC-23 were seeded on the pulpal side of the discs and the curing lights were again applied. Cell metabolism was evaluated by the MTT assay and cell morphology was assessed by SEM. Results: In groups QTH and LED the intrapulpal temperature increased by 6.4 degrees C and 3.4 degrees C, respectively. The difference between both groups was statistically significant (Mann-Whitney; P< 0.05). QTH and LED reduced the cell metabolism by 36.4% and 33.4%, respectively. Regarding the cell metabolism, no statistically significant difference was observed between both groups (Mann-Whitney; P> 0.05). However, when compared to the control, only QTH significantly reduced the cell metabolism (Mann-Whitney; P< 0.05). It was concluded that the irradiance of 0.5 mm-thick human dentin discs with a QTH in comparison to a LED curing unit promoted a higher temperature rise, which propagates through the dentin negatively affecting the metabolism of the underlying cultured pulp cells. (Am J Dent 2009;22:151-156).
Resumo:
The objective of this study was to evaluate in vitro light activation of the nano-filled resin composite Vita shade A1 and A3 with a halogen lamp (QTH) and argon ion laser by Knoop microhardness profile. Materials and methods: Specimens of nanofilled composite resin (Z350-3 M-ESPE) Vita shade A1 and A3 were prepared with a single increment inserted in 2.0-mm-thick and 3-mm diameter disc-shaped Teflon mold. The light activation was performed with QTH for 20 s (with an intensity of approximately 1,000 mW/cm(2) and 700 mW/cm(2)) and argon ion laser for 10 s (with a power of 150 mW and 200 mW). Knoop microhardness test was performed after 24 h and 6 months. The specimens were divided into the 16 experimental groups (n = 10), according to the factors under study: photoactivation form, resin shade, and storage time. Knoop microhardness data was analyzed by a factorial ANOVA and TukeyA ` s tests at the 0.05 level of significance. Results: Argon ion laser was not able to photo-activate the darker shade of the nanofilled resin composite evaluated but when used with 200 mW it can be as effective as QTH to photo-activate the lighter shade with only 50% of the time exposure. After 6 months storage, an increase in the means of Knoop microhardness values were observed. Conclusions: Light-activation significantly influenced the Knoop microhardness values for the darker nanofilled resin composite.
Resumo:
A major consideration in the performance of mouthguards is their ability to absorb energy and reduce transmitted forces when impacted. This is especially important to participants in contact sports such as hockey or football. The thickness of mouthguard materials is directly related to energy absorption and inversely related to transmitted forces when impacted. However, wearer comfort is also an important factor in their use. Thicker mouthguards are not user-friendly. While thickness of material over incisal edges and cusps of teeth is critical, just how thick should a mouthguard be and especially in these two areas? Transmitted forces through different thicknesses of the most commonly used mouthguard material, ethylene vinyl acetate (EVA) (Shore A Hardness of 80) were compared when impacted with identical forces which were capable of damaging the oro-facial complex. The constant impact force used in the tests was produced by a pendulum and had an energy of 4.4 joules and a velocity of 3 meters per second. Improvements in energy absorption and reductions in transmitted forces were observed with increasing thickness. However, these improvements lessened when the mouthguard material thickness was greater than 4 mm. The results show that the optimal thickness for EVA mouthguard material with a Shore A Hardness of 80 is around 4 mm. Increased thickness, while improving performance marginally, results in less wearer comfort and acceptance.
Resumo:
Knowledge on forced magma injection and magma flow in dykes is crucial for the understanding of how magmas migrate through the crust to the Earth's surface. Because many questions still persist, we used the long, thick, and deep-seated Foum Zguid dyke (Morocco) to investigate dyke emplacement and internal flow by means of magnetic methods, structural analysis, petrography, and scanning electron microscopy. We also investigated how the host rocks accommodated the intrusion. Regarding internal flow: 1. Important variations of the rock magnetic properties and magnetic fabric occur with distance from dyke wall; 2. anisotropy of anhysteretic remanent magnetization reveals that anisotropy of magnetic susceptibility (AMS) results mainly from the superposition of subfabrics with distinct coercivities and that the imbrication between magnetic foliation and dyke plane is more reliable to deduce flow than the orientation of the AMS maximum principal axis; and 3. a dominant upward flow near the margins can be inferred. The magnetic fabric closest to the dyke wall likely records magma flow best due to fast cooling, whereas in the core the magnetic properties have been affected by high-temperature exsolution and metasomatic effects due to slow cooling. Regarding dyke emplacement, this study shows that the thick forceful intrusion induced deformation by homogeneous flattening and/or folding of the host sedimentary strata. Dewatering related to heat, as recorded by thick quartz veins bordering the dyke in some localities, may have also helped accommodating dyke intrusion. The spatial arrangement of quartz veins and their geometrical relationship with the dyke indicate a preintrusive to synintrusive sinistral component of strike slip.
Resumo:
Three different lubricating greases and their bleed and base oils were compared in terms of film thickness in a ball-on-disc test rig through optical interferometry. The theoretical values calculated according to Hamrock's equation are in close agreement with the base oil film thickness measurements, which validates the selected experimental methodology. The grease and bleed oil film thickness under fully flooded lubrication conditions presented quite similar behaviour and levels. Therefore, the grease film thickness under full film conditions might be predicted using their bleed oil properties, namely the viscosity and pressure-viscosity coefficient. The base and bleed oil lubricant parameter LP are proportional to the measured film thickness. A relationship between grease and the corresponding bleed oil film thickness was evidenced.
Resumo:
In this work, the shear modulus and strength of the acrylic adhesive 3M® DP 8005 was evaluated by two different methods: the Thick Adherend Shear Test (TAST) and the Notched Plate Shear Method (Arcan). However, TAST standards advise the use of a special extensometer attached to the specimen, which requires a very experienced technician. In the present study, the adhesive shear displacement for the TAST was measured using an optical technique, and also with a conventional inductive extensometer of 25 mm used for tensile tests. This allowed for an assessment of suitability of using a conventional extensometer to measure this parameter. Since the results obtained by the two techniques are identical, it can be concluded that using a conventional extensometer is a valid option to obtain the shear modulus for the particular adhesive used. In the Arcan tests, the adhesive shear displacement was only measured using the optical technique. This work also aimed the comparison of shear modulus and strength obtained by the TAST and Arcan test methods.
Resumo:
A detailed analysis of fabrics of the chilled margin of a thick dolerite dyke (Foum Zguid dyke, Southern Morocco) was performed in order to better understand the development of sub-fabrics during dyke emplacement and cooling. AMS data were complemented with measurements of paramagnetic and ferrimagnetic fabrics (measured with high field torque magnetometer), neutron texture and microstructural analyses. The ferrimagnetic and AMS fabrics are similar, indicating that the ferrimagnetic minerals dominate the AMS signal. The paramagnetic fabric is different from the previous ones. Based on the crystallization timing of the different mineralogical phases, the paramagnetic fabric appears related to the upward flow, while the ferrimagnetic fabric rather reflects the late-stage of dyke emplacement and cooling stresses. (C) 2014 Elsevier B.V. All rights reserved.
Resumo:
As estruturas coladas são geralmente projetadas para que o adesivo seja essencialmente sujeito a esforços de corte, pois neste tipo de solicitação o adesivo apresenta melhores caraterísticas mecânicas. A avaliação do comportamento ao corte pode ser realizada com o adesivo no estado maciço ou como camada fina em juntas adesivas. Os métodos que permitem avaliar o comportamento ao corte, quer para o adesivo, quer para as juntas, são: o ensaio Iosipescu ou V-Notched beam shear method, o ensaio de borboleta ou Notched plate shear method (Arcan), o ensaio de torsão, o ensaio de tração numa junta de sobreposição simples e o ensaio Thick Adherend Shear Test (TAST). Os ensaios Arcan e Iosipescu, tal como o ensaio de torção, podem ser realizados em provetes de adesivo maciço ou em juntas. O ensaio de torção é pouco utilizado, porque a aplicação do esforço de corte exige dispositivos e equipamentos de ensaios complexos. Os ensaios Arcan e Iosipescu utilizam provetes com entalhes e podem introduzir alguma dificuldade na medição precisa das deformações. O ensaio de tração numa junta de sobreposição simples é um dos métodos mais usados para caraterizar uma junta adesiva, porque é um método simples, as juntas são de fácil fabrico e pode ser realizado em máquinas universais de ensaios mecânicos. Neste ensaio os aderentes estão sujeitos a uma solicitação de tração, enquanto a camada de adesivo está sujeita a esforços de corte combinados com esforços de arrancamento. Os esforços de arrancamento resultam da própria geometria da junta na qual existe um desalinhamento das forças de tração, mesmo quando são colocados calços (reguladores de espessura) nos locais de amarração. O ensaio TAST é dos mais populares para obtenção das propriedades ao corte, uma vez que tanto as ferramentas de ensaio como o fabrico dos provetes são relativamente simples. Este ensaio é realizado em junta sendo os substratos espessos e de aço que, devido à sua elevada rigidez, contribuem para um esforço de corte praticamente puro no adesivo. Neste trabalho realizou-se o projeto e a fabricação das ferramentas, gabarit e substratos necessários para a execução de provetes TAST e ensaios utilizando diferentes adesivos.
Resumo:
This study compared the efficiency of Kato-Katz thick smear and thick smear techniques for the diagnosis of intestinal helminths. The sensitivity of the thick smear technique was higher than that of the Kato-Katz method for the diagnosis of all helminths except Schistosoma mansoni.
Resumo:
Tese de Doutoramento em Engenharia Mecânica.
Resumo:
Magdeburg, Univ., Fak. für Naturwiss., Diss., 2013
Resumo:
Magdeburg, Univ., Fak. für Naturwiss., Diss., 2013
Resumo:
In this paper we study basic properties of the weighted Hardy space for the unit disc with the weight function satisfying Muckenhoupt's (Aq) condition, and study related approximation problems (expansion, moment and interpolation) with respect to two incomplete systems of holomorphic functions in this space.