914 resultados para System monitoring


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Waste oil recycling companies play a very important role in our society. Competition among companies is tough and process optimization is essential for survival. By equipping oil containers with a level monitoring system that periodically reports the level and alerts when it reaches the preset threshold, the oil recycling companies are able to streamline the oil collection process and, thus, reduce the operation costs while maintaining the quality of service. This paper describes the development of this level monitoring system by a team of four students from different engineering backgrounds and nationalities. The team conducted a study of the state of the art, draw marketing and sustainable development plans and, finally, designed and implemented a prototype that continuously measures the container content level and sends an alert message as soon as it reaches the preset capacity.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The Electromyography (EMG) is an important tool for gait analyzes and disorders diagnoses. Traditional methods involve equipment that can disturb the analyses, being gradually substituted by different approaches, like wearable and wireless systems. The cable replacement for autonomous systems demands for technologies capable of meeting the power constraints. This work presents the development of an EMG and kinematic data capture wireless module, designed taking into account power consumption issues. This module captures and converts the analog myoeletric signal to digital, synchronously with the capture of kinetic information. Both data are time multiplexed and sent to a PC via Bluetooth link. The work carried out comprised the development of the hardware, the firmware and a graphical interface running in an external PC. The hardware was developed using the PIC18F14K22, a low power family of microcontrollers. The link was established via Bluetooth, a protocol designed for low power communication. An application was also developed to recover and trace the signal to a Graphic User Interface (GUI), coordinating the message exchange with the firmware. Results were obtained which allowed validating the conceived system in static and with the subject performing short movements. Although it was not possible to perform the tests within more dynamic movements, it is shown that it is possible to capture, transmit and display the captured data as expected. Some suggestions to improve the system performance also were made.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia Electrotécnica e de Computadores

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Despite the recent progresses in robotics, autonomous robots still have too many limitations to reliably help people with disabilities. On the other hand, animals, and especially dogs, have already demonstrated great skills in assisting people in many daily situations. However, dogs also have their own set of limitations. For example, they need to rest periodically, to be healthy (physically and psychologically), and it is difficult to control them remotely. This project aims to “augment” the Assistance dog, by developing a system that compensates some of the dog weaknesses through a robotic device mounted on the dog harness. This specific study, involved in the COCHISE project, focuses on the development of a system for the monitoring of dogs activity and physiological parameters.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The Inequalities Monitoring System comprises a basket of indicators which are monitored over time to assess area differences in morbidity, utilisation of and access to health and social care services in Northern Ireland. Inequalities between the 20% most deprived electoral wards and Northern Ireland as a whole are measured with deprived areas identified from an update of the Noble Income domain for current ward boundaries. Results for 20% most rural areas were also compared against Northern Ireland overall using population density from the 2001 Census of Population as a measure of rurality. This report is the first annual update of the baseline results presented in Chapter 8 of Equality and Inequalities in Health and Social care in Northern Ireland – A Statistical Overview (DHSSPS 2004) which focused on 2001/2002. The morbidity and utilisation data in this report are the latest available while the locations of services for the accessibility analysis will be updated in subsequent years åÊ

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The Inequalities Monitoring System comprises a basket of indicators which are monitored over time to assess area differences in morbidity, utilisation of and access to health and social care services in Northern Ireland. Inequalities between the 20% most deprived electoral wards and Northern Ireland as a whole are measured with deprived areas identified from an update of the Noble Income domain for current ward boundaries. Results for 20% most rural areas were also compared against Northern Ireland overall using population density from the 2001 Census of Population as a measure of rurality. This report is the firståÊ annual update of the baseline results presented in Chapter 8 of Equality and Inequalities in Health and Social care in Northern Ireland – A Statistical Overview (DHSSPS 2004) which focused on 2001/2002. The morbidity and utilisation data in this report are the latest available while the locations of services for the accessibility analysis will be updated in subsequent years. åÊ åÊ

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Key Points: Health outcomes are generally worse in the most deprived areas in Northern Ireland when compared both with those witnessed in the region generally and in the least deprived areas. Large differences (health inequality gaps) continue to exist for a number of different health measures. åá Males in the 20% most deprived areas could expect, on average, to live 4.3 fewer years than the NI average and 7.3 fewer years than those in the 20% least deprived areas.åá Female life expectancy in the most deprived areas was 2.6 years less than the regional average and 4.3 years less than that in the least deprived areas.åá The overall death rate for males as measured by the All Age All Cause Mortality (AAACM) rate was a fifth higher in the most deprived areas (1,567 deaths per 100,000 population) than the NI average (1,304 deaths per 100,000 population), and 44% higher than in the least deprived areas (1,090 deaths per 100,000 population).åá The overall death rate for females (AAACM) in the most deprived areas (1,093 deaths per 100,000 population) was 17% higher than regionally (935 deaths per 100,000 population), and a third higher than in the least deprived areas (829 deaths per 100,000 population).åá The suicide rate in the most deprived areas (30.7 deaths per 100,000 population) was three times that in the least deprived areas (10.1 deaths per 100,000 population). All HSCIMS reports are published on the Departmental website at: http://www.dhsspsni.gov.uk/index/statistics/health-inequalities.htm

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Determining groundwater flow paths of infiltrated river water is necessary for studying biochemical processes in the riparian zone, but their characterization is complicated by strong temporal and spatial heterogeneity. We investigated to what extent repeat 3D surface electrical resistance tomography (ERT) can be used to monitor transport of a salt-tracer plume under close to natural gradient conditions. The aim is to estimate groundwater flow velocities and pathways at a site located within a riparian groundwater system adjacent to the perialpine Thur River in northeastern Switzerland. Our ERT time-lapse images provide constraints on the plume's shape, flow direction, and velocity. These images allow the movement of the plume to be followed for 35 m. Although the hydraulic gradient is only 1.43 parts per thousand, the ERT time-lapse images demonstrate that the plume's center of mass and its front propagate with velocities of 2x10(-4) m/s and 5x10(-4) m/s, respectively. These velocities are compatible with groundwater resistivity monitoring data in two observation wells 5 m from the injection well. Five additional sensors in the 5-30 m distance range did not detect the plume. Comparison of the ERT time-lapse images with a groundwater transport model and time-lapse inversions of synthetic ERT data indicate that the movement of the plume can be described for the first 6 h after injection by a uniform transport model. Subsurface heterogeneity causes a change of the plume's direction and velocity at later times. Our results demonstrate the effectiveness of using time-lapse 3D surface ERT to monitor flow pathways in a challenging perialpine environment over larger scales than is practically possible with crosshole 3D ERT.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background: Oncological treatments are traditionally administered via intravenous injection by qualified personnel. Oral formulas which are developing rapidly are preferred by patients and facilitate administration however they may increase non-adherence. In this study 4 common oral chemotherapeutics are given to 50 patients, who are still in the process of inclusion, divided into 4 groups. The aim is to evaluate adherence and offer these patients interdisciplinary support with the joint help of doctors and pharmacists. We present here the results for capecitabine. Materials and Methods: The final goal is to evaluate adhesion in 50 patients split into 4 groups according to oral treatments (letrozole/exemestane, imatinib/sunitinib, capecitabine and temozolomide) using persistence and quality of execution as parameters. These parameters are evaluated using a medication event monitoring system (MEMS®) in addition to routine oncological visits and semi-structured interviews. Patients were monitored for the entire duration of treatment up to a maximum of 1 year. Patient satisfaction was assessed at the end of the monitoring period using a standardized questionary. Results: Capecitabine group included 2 women and 8 men with a median age of 55 years (range: 36−77 years) monitored for an average duration of 100 days (range: 5-210 days). Persistence was 98% and quality of execution 95%. 5 patients underwent cyclic treatment (2 out of 3 weeks) and 5 patients continuous treatment. Toxicities higher than grade 1 were grade 2−3 hand-foot syndrome in 1 patient and grade 3 acute coronary syndrome in 1 patient both without impact on adherence. Patients were satisfied with the interviews undergone during the study (57% useful, 28% very useful, 15% useless) and successfully integrated the MEMS® in their daily lives (57% very easily, 43% easily) according to the results obtained by questionary at the end of the monitoring period. Conclusion: Persistence and quality of execution observed in our Capecitabine group of patients were excellent and better than expected compared to previously published studies. The interdisciplinary approach allowed us to better identify and help patients with toxicities to maintain adherence. Overall patients were satisfied with the global interdisciplinary follow-up. With longer follow up better evaluation of our method and its impact will be possible. Interpretation of the results of patients in the other groups of this ongoing trial will provide us information for a more detailed analysis.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Applications of genetic constructs with multiple promoters, which are fused with reporter genes and simultaneous monitoring of various events in cells, have gained special attention in recent years. Lentiviral vectors, with their distinctive characteristics, have been considered to monitor the developmental changes of cells in vitro. In this study, we constructed a novel lentiviral vector (FUM-M), containing two germ cell-specific promoters (Stra8 and c-kit), fused with ZsGreen and DsRed2 reporter genes, and evaluated its efficiency in different cells following treatments with retinoic acid and DMSO. Several cell lines (P19, GC-1 spg and HEK293T) were transduced with this vector, and functional capabilities of the promoters were verified by flow cytometry and quantitative RT-PCR. Our results indicate that FUM-M shows dynamic behavior in the presence and absence of extrinsic factors. A correlation was also observed between the function of promoters, present in the lentiviral construct and the endogenous level of the Stra8 and c-kit mRNAs in the cells. In conclusion, we recommend this strategy, which needs further optimization of the constructs, as a beneficial and practical way to screen chemical inducers involved in cellular differentiation toward germ-like cells.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Applications of genetic constructs with multiple promoters, which are fused with reporter genes and simultaneous monitoring of various events in cells, have gained special attention in recent years. Lentiviral vectors, with their distinctive characteristics, have been considered to monitor the developmental changes of cells in vitro. In this study, we constructed a novel lentiviral vector (FUM-M), containing two germ cell-specific promoters (Stra8 and c-kit), fused with ZsGreen and DsRed2 reporter genes, and evaluated its efficiency in different cells following treatments with retinoic acid and DMSO. Several cell lines (P19, GC-1 spg and HEK293T) were transduced with this vector, and functional capabilities of the promoters were verified by flow cytometry and quantitative RT-PCR. Our results indicate that FUM-M shows dynamic behavior in the presence and absence of extrinsic factors. A correlation was also observed between the function of promoters, present in the lentiviral construct and the endogenous level of the Stra8 and c-kit mRNAs in the cells. In conclusion, we recommend this strategy, which needs further optimization of the constructs, as a beneficial and practical way to screen chemical inducers involved in cellular differentiation toward germ-like cells.