170 resultados para Sylvian fissure
Resumo:
This article presents a case report of autogenous tooth transplantation to the site of the fissure, in addition to bone augmentation with graft of autogenous bone harvested from the iliac crest, performed in a cleft palate patient, who had insufficient bone volume. A non-syndromic 10-year-old girl, with a unilateral cleft lip and palate, incisal transforamen fissures, agenesis of the maxillary left central incisor and both maxillary lateral incisors, was treated with autogenous bone graft in the cleft area. The orthodontic treatment plan was to replace the missing lateral incisors with the maxillary canines and to extract the mandibular first premolars. One of the mandibular premolars was extracted from its site with 2/3 of its root formation completed and transplanted to the maxillary left central incisor area. After orthodontic treatment, the anatomic crowns were characterized with composite resin. Autogenous tooth transplantation can be performed in the area of the fissure in young cleft palate patients, by performing bone graft augmentation before transplantation of the tooth, to gain sufficient recipient alveolar bone volume. A multidisciplinary approach is mandatory for the success of this clinical procedure, especially in cleft palate patients. © 2012 John Wiley & Sons A/S.
Resumo:
New pit-and-fissure sealants with the capacity to release calcium and phosphate because of the presence of ACP have been introduced into the dental marketplace. With the continuous introduction of new dental materials, it is important not only to research and confirm their properties, but also to propose modifications or associations that may contribute to their improvement.
Resumo:
This study investigated the structure of the fissure fundus on occlusal surfaces with respect to the detection of possible irregularities below the enamel-dentin junction (EDJ). Occlusal surfaces were examined by micro-computed tomography (µCT). In total, 203 third molars with clinically sound occlusal fissures or non-cavitated lesions were selected. All specimens were scanned with µCT. Subsequently, each tooth was sectioned, and each slice was investigated by stereomicroscopy. In 7 of 203 molars (3.4%), demarcated radiolucencies below the EDJ were detected by µCT. These defects were obviously of non-carious origin, because the µCT images revealed no gradient of demineralization in the dentin. In all cases, a direct pathway between the oral cavity and the dentin was evident. The comparison of the µCT sites with conventional histological images also revealed defects in the dentin. These results demonstrate that demarcated radiolucencies below the EDJ may not necessarily be caries lesions according to µCT images and may be classified as possible developmental irregularities. To avoid misinterpreting µCT data, dental researchers should carefully consider this condition when analyzing µCT images. The clinical significance of this finding is that these defects may predispose molar teeth to early-onset caries in occlusal pits and fissures.
Resumo:
OBJECTIVES AND METHODS: This study investigated the sealing ability of a current available unfilled fissure sealant applied over sound (n=80), artificially created (n=80) and naturally carious fissures (n=80) under different humidity conditions (90+/-2 and 45+/-2% relative humidity) and etching times (40 and 60s). All samples were submitted to 5000 thermal cycles and examined by light microscopy after sectioning. Microleakage, penetration ability, fissure type, fissure entrance angle, sealant occlusal length, caries location and caries depth were assessed. RESULTS: The significantly longer sealant occlusal length and larger entrance angle exhibited by shallow fissures, contributed to their higher microleakage and smaller amounts of unfilled areas compared to deep fissures. Sealant microleakage was significantly influenced by the condition of the enamel (sound, artificial and natural caries) and the caries location in the fissures, but not by enamel caries depth (D1 and D2), etching time, or humidity condition. Natural caries exhibited significantly higher microleakage than sound or artificially created carious fissures. CONCLUSIONS: Based on the results of this study, it can be concluded that location of caries in the fissure rather than its depth should be taken into account when applying a fissure sealant. When the borders of the fissure sealant are on carious enamel, a significantly higher microleakage must be expected. The artificial caries model was not a suitable method to assess the behavior of natural fissure caries.
Resumo:
The aim of this in vitro study was to evaluate the influence of pit and fissure sealants on fluorescence readings using lasers. We selected 166 permanent molars and randomly divided them into 4 groups which were each treated with a different sealant (a commercially available clear sealant, 2 opaque sealants and an experimental nanofilled clear sealant). The teeth were independently measured twice by 2 experienced dentists using conventional laser fluorescence (LF) and a laser fluorescence pen device (LFpen), before and after sealing, and again after thermocycling to simulate the thermal stressing between the tooth and the dental materials. Friedman test showed no statistically significant changes using LF and LFpen for the commercial clear sealant group, although values tended to increase after sealing. However, the values increased significantly after thermocycling. There was a statistically significant decrease in fluorescence after application of opaque sealants. After application of the experimental nanofilled clear sealant, LF values increased only after thermocycling, whereas the LFpen values increased after sealing and after thermocycling as well. The intraclass correlation coefficient ranged from 0.87 to 0.96 for interexaminer and 0.82 to 0.94 for intraexaminer reproducibility. It was shown that pit and fissure sealants influence LF and LFpen readings, with the values increasing or decreasing according to the material used. In conclusion, both laser fluorescence devices could be useful as an adjunct to detect occlusal caries under unfilled clear sealants. Nevertheless, surfaces sealed with clear nanofilled material could be assessed using only the LF device.
Resumo:
OBJECTIVE To search the literature and assess the short- and long-term release of bisphenol-A (BPA) in human tissues after treatment with dental sealants. DATA Two review authors performed data extraction independently and in duplicate using data collection forms. Disagreements were resolved by discussion with an arbiter. SOURCES Electronic database searches of published and unpublished literature were performed. The following electronic databases with no language and publication date restrictions were searched: MEDLINE (via Ovid and Pubmed), EMBASE (via ovid), Cochrane Trials Register and CENTRAL. The reference lists of all eligible studies were hand-searched. STUDY SELECTION In the absence of RCTs, six interventional and two observational studies, examining in vivo BPA release in human salivary, blood and urinary samples, were included. Due to the heterogeneity in methodology and reporting, the main synthesis of the results was qualitative. The quantitative synthesis based on the weighted Z-test could only include two studies. BPA levels identified in saliva ranged from traces below the method's detection limit to 30 μg/ml. In urine, BPA quantities spanned from 0.17 mg/g to 45.4 mg/g. BPA was not traced in any blood sample at any point of time in the relevant studies. The quantitative analysis showed evidence of BPA release one hour after sealant placement compared to the amount traced before restoration (Stouffer's z trend: <0.001). CONCLUSIONS The available evidence on this topic derived from studies that represent a moderate level of evidence. Nevertheless, the available evidence supports that BPA is released in saliva after sealant placement. CLINICAL SIGNIFICANCE From the qualititative and quantitative synthesis of studies, it is reasonable to conclude that BPA is released after placement of some dental pit and fissure sealants in the oral cavity. The biggest quantities are detected in saliva immediately after or one hour after their placement.
Resumo:
The aim of the study was to compare fissure sealant quality after mechanical conditioning of erbium-doped yttrium aluminium garnet (Er:YAG) laser or air abrasion prior to chemical conditioning of phosphoric acid etching or of a self-etch adhesive. Twenty-five permanent molars were initially divided into three groups: control group (n = 5), phosphoric acid etching; test group 1 (n = 10), air abrasion; and test group 2, (n = 10) Er:YAG laser. After mechanical conditioning, the test group teeth were sectioned buccolingually and the occlusal surface of one half tooth (equal to one sample) was acid etched, while a self-etch adhesive was applied on the other half. The fissure system of each sample was sealed, thermo-cycled and immersed in 5% methylene dye for 24 h. Each sample was sectioned buccolingually, and one slice was analysed microscopically. Using specialized software microleakage, unfilled margin, sealant failure and unfilled area proportions were calculated. A nonparametric ANOVA model was applied to compare the Er:YAG treatment with that of air abrasion and the self-etch adhesive with phosphoric acid (α = 0.05). Test groups were compared to the control group using Wilcoxon rank sum tests (α = 0.05). The control group displayed significantly lower microleakage but higher unfilled area proportions than the Er:YAG laser + self-etch adhesive group and displayed significantly higher unfilled margin and unfilled area proportions than the air-abrasion + self-etch adhesive group. There was no statistically significant difference in the quality of sealants applied in fissures treated with either Er:YAG laser or air abrasion prior to phosphoric acid etching, nor in the quality of sealants applied in fissures treated with either self-etch adhesive or phosphoric acid following Er:YAG or air-abrasion treatment.
Resumo:
Cet article revient sur le processus d'édition de La Fissure de Robert Pinget, roman inédit que l'auteur a eu l'occasion de publier dans «Le Métier à tisser», collection qu'il dirige à Genève chez MetisPresses, avec une préface de Clothilde Roullier.
Resumo:
Diverses œuvres de poésie moderne et contemporaine mettent en scène le rapport à l’écriture d’un sujet lyrique. Une telle problématique trouve une incarnation particulièrement intéressante dans l’œuvre de Patrice Desbiens, notamment dans certains de ses textes des années 1990 et 2000, où elle apparaît avec plus d’acuité. Pourtant, sa pratique auto-réflexive a fait l’objet de très peu de recherches. Afin d’éclairer le rapport qu’entretient Patrice Desbiens avec l’écriture et avec la poésie, ce mémoire s’intéresse à deux de ses textes, soit La fissure de la fiction (1997) et Désâmé, (2005) en accordant davantage d’espace au premier, que je considère comme un texte-charnière dans la production poétique de Desbiens. Dans un premier temps, mon travail présente ainsi la précarité qui caractérise le protagoniste de La fissure de la fiction et, sous un autre angle, le sujet lyrique de Désâmé. Dans cette optique, la figure du poète est étudiée dans La fissure de la fiction à la lumière de la reprise ironique du mythe de la malédiction littéraire et du sens que la réactualisation de ce mythe confère au personnage dans ce récit poétique. Dans un second temps, ce mémoire s’attache à montrer que la cohérence et la vraisemblance des univers mis en scène dans La fissure de la fiction et Désâmé sont minées. C’est à l’aune de ces analyses que peut ensuite être envisagé le rôle d’une poésie qui, en dernière instance, comporte malgré tout un caractère consolateur, en dépit ou en raison de l’esthétique du grotesque, tantôt comique, tantôt tragique, dans laquelle elle s’inscrit et que nous tâcherons de mettre en lumière.
Resumo:
Diverses œuvres de poésie moderne et contemporaine mettent en scène le rapport à l’écriture d’un sujet lyrique. Une telle problématique trouve une incarnation particulièrement intéressante dans l’œuvre de Patrice Desbiens, notamment dans certains de ses textes des années 1990 et 2000, où elle apparaît avec plus d’acuité. Pourtant, sa pratique auto-réflexive a fait l’objet de très peu de recherches. Afin d’éclairer le rapport qu’entretient Patrice Desbiens avec l’écriture et avec la poésie, ce mémoire s’intéresse à deux de ses textes, soit La fissure de la fiction (1997) et Désâmé, (2005) en accordant davantage d’espace au premier, que je considère comme un texte-charnière dans la production poétique de Desbiens. Dans un premier temps, mon travail présente ainsi la précarité qui caractérise le protagoniste de La fissure de la fiction et, sous un autre angle, le sujet lyrique de Désâmé. Dans cette optique, la figure du poète est étudiée dans La fissure de la fiction à la lumière de la reprise ironique du mythe de la malédiction littéraire et du sens que la réactualisation de ce mythe confère au personnage dans ce récit poétique. Dans un second temps, ce mémoire s’attache à montrer que la cohérence et la vraisemblance des univers mis en scène dans La fissure de la fiction et Désâmé sont minées. C’est à l’aune de ces analyses que peut ensuite être envisagé le rôle d’une poésie qui, en dernière instance, comporte malgré tout un caractère consolateur, en dépit ou en raison de l’esthétique du grotesque, tantôt comique, tantôt tragique, dans laquelle elle s’inscrit et que nous tâcherons de mettre en lumière.
Resumo:
INTRODUÇÃO: Alterações neurológicas ou sensoriais, entre elas as alterações auditivas periféricas e/ou centrais, são enfatizadas na população com baixo peso ao nascimento (BP), assim como, na presença de malformação craniofacial, tal como a fissura labiopalatina (FLP). OBJETIVO: Verificar e comparar o resultado de testes de processamento auditivo, Teste Dicótico de Dígitos (TDD) e Teste de Fusão Auditiva-Revisado (AFT-R), de crianças com FLP com e BP ao nascimento, com o de crianças sem FLP e nascida com peso normal. MÉTODO: Estudo retrospectivo e comparativo de 73 prontuários, dos quais foram verificados o sexo, peso ao nascimento, presença/ausência de FLP e o resultado de TDD e AFT-R. Foram constituídos três grupos de acordo com a análise do peso ao nascimento e presença ou ausência de FLP. RESULTADOS: Para o TDD a Análise de Covariância não mostrou diferença entre os grupos e sexos, porém a co-variável idade mostrou relação estatisticamente significante. Para o AFT-R não mostrou diferença entre os grupos, sexos e idades. CONCLUSÃO: Crianças com FLP e BP, embora sem significância estatística, apresentam maiores alterações nos testes de processamento auditivo utilizados ao comparar com crianças com FLP isolada e com crianças sem esta malformação craniofacial e sem BP. Ressalta-se ainda que o aumento da idade melhorou o desempenho no TDD.
Resumo:
This study evaluated in vitro the shear bond strength of a resin-based pit-and-fissure sealant (Fluroshield - F) associated with either an ethanol-based (Adper Single Bond 2 - SB) or an acetone-based (Prime & Bond - PB) adhesive system under conditions of oil contamination. Mesial and distal enamel surfaces from 30 sound third molars were randomly assigned to 2 groups (n=30): I - no oil contamination; II - oil contamination. Contamination (0.25 mL during 10 s) was performed after 37% phosphoric acid etching with an air/oil spray. The specimens were randomly assigned to subgroups, according to the bonding protocol adopted: subgroup A - F was applied to enamel without an intermediate bonding agent layer; In subgroups B and C, SB and PB, respectively, were applied, light-cured, and then F was applied and light-cured. Shear bond strength was tested at a crosshead speed of 0.5 mm/min in a universal testing machine. Means (± SD) in MPa were: IA-11.28 (±1.84); IIA-12.02 (±1.15); IB-9.73 (±2.38); IIB-9.62 (±2.29); IC-28.30 (±1.63); and IIC-25.50 (±1.91). It may be concluded that the oil contamination affected negatively the sealant bonding to enamel and the acetone-based adhesive system (PB) layer applied underneath the sealant was able to prevent its deleterious effects to adhesion.