928 resultados para Surgical Instruments


Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Peri-implantitis is a frequent finding in patients with dental implants. The present study compared two non-surgical mechanical debridement methods of peri-implantitis. MATERIAL AND METHODS: Thirty-seven subjects (mean age 61.5; S.D+/-12.4), with one implant each, demonstrating peri-implantitis were randomized, and those treated either with titanium hand-instruments or with an ultrasonic device were enrolled. Data were obtained before treatment, and at 1, 3, and 6 months. Parametric and non-parametric statistics were used. RESULTS: Thirty-one subjects completed the study. The mean bone loss at implants in both groups was 1.5 mm (SD +/-1.2 mm). No group differences for plaque or gingival indices were found at any time point. Baseline and 6-month mean probing pocket depths (PPD) at implants were 5.1 and 4.9 mm (p=0.30) in both groups. Plaque scores at treated implants decreased from 73% to 53% (p<0.01). Bleeding scores also decreased (p<0.01), with no group differences. No differences in the total bacterial counts were found over time. Higher total bacterial counts were found immediately after treatment (p<0.01) and at 1 week for ultrasonic-treated implants (p<0.05). CONCLUSIONS: No group differences were found in the treatment outcomes. While plaque and bleeding scores improved, no effects on PPD were identified.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction. Patient safety culture is the integration of interrelated practices that once developed is supported by both the culture and leadership of the organization (Sagan, 1993). The purpose of this study is to describe and examine the relationship between surgical residents’ perception of their leadership and the resulting organizational safety culture within their clinical setting. This assessment is important to understanding the extent that leadership style affects the perception of the safety culture.^ Methods. A secondary dataset was used which included data from 68 surgical residents from two survey instruments, Organizational Description Questionnaire (ODQ) and Patient Safety Climate In Healthcare Organizations (PSCHO) Survey. Multiple regressions followed by hierarchical regressions with the introduction of the Post Graduate Year (PGY) variable examined the association between the leadership styles, Transactional and Transformational and the organizational safety culture variables, Overall Emphasis on Safety, Senior management engagement, Organizational resources for safety. Independent t-tests were conducted to assess whether males and females differ among the organizational safety culture variables and either leadership style.^ Results. The surgical residents perceived their organizational leadership to have greater emphasis placed on transformational leadership culture style relative to transactional leadership culture style. The only significant association found was between Transformational leadership and Organizational resources for safety. PGY had no significant effect on the leadership or the safety culture perceived. No significant difference was found between females and males in regards to the safety culture or the leadership style.^ Discussion. These results have implications as they support the premise for the study which is surgical residents perceive their existing leadership and organizational culture to be more transformational in nature than transactional. Significance was found between the leadership perceived and one of the safety culture variables, Organizational resources for safety. The foundation for this association lies in the fact that surgical residents are the personnel which are a part of the organizational resources. Although PGY differentiation did not seem to play a difference in the leadership perceived this could be attributed to the small sample size. No gender difference were found which supports the assumption that within such a highly specialized group such as surgical residents there is no gender differences since the highly specialized field draws a certain type of person with distinct characteristics. In future research these survey tools can be used to gauge the survey audiences’ perception and safety interventions can be developed based on the results. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The present work covers the first validation efforts of the EVA Tracking System for the assessment of minimally invasive surgery (MIS) psychomotor skills. Instrument movements were recorded for 42 surgeons (4 expert, 22 residents, 16 novice medical students) and analyzed for a box trainer peg transfer task. Construct validation was established for 7/9 motion analysis parameters (MAPs). Concurrent validation was determined for 8/9 MAPs against the TrEndo Tracking System. Finally, automatic determination of surgical proficiency based on the MAPs was sought by 3 different approaches to supervised classification (LDA, SVM, ANFIS), with accuracy results of 61.9%, 83.3% and 80.9% respectively. Results not only reflect on the validation of EVA for skills? assessment, but also on the relevance of motion analysis of instruments in the determination of surgical competence.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To compare assessment capabilities of a motion analysis tool against a validated checklist during laparoscopic training.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background Objective assessment of psychomotor skills has become an important challenge in the training of minimally invasive surgical (MIS) techniques. Currently, no gold standard defining surgical competence exists for classifying residents according to their surgical skills. Supervised classification has been proposed as a means for objectively establishing competence thresholds in psychomotor skills evaluation. This report presents a study comparing three classification methods for establishing their validity in a set of tasks for basic skills’ assessment. Methods Linear discriminant analysis (LDA), support vector machines (SVM), and adaptive neuro-fuzzy inference systems (ANFIS) were used. A total of 42 participants, divided into an experienced group (4 expert surgeons and 14 residents with >10 laparoscopic surgeries performed) and a nonexperienced group (16 students and 8 residents with <10 laparoscopic surgeries performed), performed three box trainer tasks validated for assessment of MIS psychomotor skills. Instrument movements were captured using the TrEndo tracking system, and nine motion analysis parameters (MAPs) were analyzed. The performance of the classifiers was measured by leave-one-out cross-validation using the scores obtained by the participants. Results The mean accuracy performances of the classifiers were 71 % (LDA), 78.2 % (SVM), and 71.7 % (ANFIS). No statistically significant differences in the performance were identified between the classifiers. Conclusions The three proposed classifiers showed good performance in the discrimination of skills, especially when information from all MAPs and tasks combined were considered. A correlation between the surgeons’ previous experience and their execution of the tasks could be ascertained from results. However, misclassifications across all the classifiers could imply the existence of other factors influencing psychomotor competence.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Poster Purpose: A study to validate a prototype Hartmann-Shack (HS) wavefront aberrometer. Methods: The dynamic range was assessed using a calibrated model eye. It was validated against a conventional HS-aberrometer (Topcon KR1W) in 75 eyes using both instruments in random order. Additionally, intra-sessional repeatability was tested. Results: The aberrometer showed a large dynamic range of +21.0 D to −25.0 D. It was comparable to a conventional HS aberrometer for spherical-equivalent SE (MD ± 95% CI: 0.02 ± 0.49D; correlation: r = 0.995, p < 0.001), astigmatic components (J0: 0.02 ± 0.15D; r = 0.977, p < 0.001; J45: 0.03 ± 0.28; r = 0.666, p < 0.001) and HOAs RMS (0.02 ± 0.20D; r = 0.620, p < 0.001). Intra-sessional repeatability correlation was also excellent (SE = 1.000, p < 0.001; astigmatic-components J0 = 0.998, p < 0.001, J45 = 0.980, p < 0.01; HOAs RMS = 0.961, p < 0.001). Conclusions: This study confirms the validity of the prototype aberrometer. The prototype aberrometer can measure continuously to provide direct feedback of the optical status of the eye during surgery.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Transconjunctival microincision vitrectomy surgery (MIVS) has grown increasingly popular among vitreoretinal surgeons over the last few years. Technical advances have led to the development of cutting-edge vitrectomy systems and instruments that significantly contributed to the success of MIVS. Trocar evolution has added extra safeness and effectiveness to the technique. In the hands of an experienced surgeon, microincision vitrectomy trocars offer a new range of applications that can redefine surgical practices and facilitate otherwise complex surgical techniques.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Transconjunctival microincision vitrectomy surgery (MIVS) has grown increasingly popular among vitreoretinal surgeons over the last few years. Technical advances have led to the development of cutting-edge vitrectomy systems and instruments that significantly contributed to the success of MIVS. Trocar evolution has added extra safeness and effectiveness to the technique. In the hands of an experienced surgeon, microincision vitrectomy trocars offer a new range of applications that can redefine surgical practices and facilitate otherwise complex surgical techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hospital acquired infections (HAI) are costly but many are avoidable. Evaluating prevention programmes requires data on their costs and benefits. Estimating the actual costs of HAI (a measure of the cost savings due to prevention) is difficult as HAI changes cost by extending patient length of stay, yet, length of stay is a major risk factor for HAI. This endogeneity bias can confound attempts to measure accurately the cost of HAI. We propose a two-stage instrumental variables estimation strategy that explicitly controls for the endogeneity between risk of HAI and length of stay. We find that a 10% reduction in ex ante risk of HAI results in an expected savings of £693 ($US 984).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recently the National Patient Safety Agency in the United Kingdom published a report entitled "Mitigating surgical risk in patients undergoing hip arthroplasty for fractures of the proximal femur". A total of 26 deaths had been reported to them when cement was used at hemiarthroplasty between October 2003 and October 2008. This paper considers the evidence for using cement fixation of a hemiarthroplasty in the treatment of hip fractures.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research has established, through ultrasound, near infrared spectroscopy and biomechanics experiments, parameters and parametric relationships that can form the framework for quantifying the integrity of the articular cartilage-on-bone laminate, and objectively distinguish between normal/healthy and abnormal/degenerated joint tissue, with a focus on articular cartilage. This has been achieved by: 1. using traditional experimental methods to produce new parameters for cartilage assessment; 2. using novel methodologies to develop new parameters; and 3. investigating the interrelationships between mechanical, structural and molec- ular properties to identify and select those parameters and methodologies that can be used in a future arthroscopic probe based on points 1 and 2. By combining the molecular, micro- and macro-structural characteristics of the tissue with its mechanical properties, we arrive at a set of critical benchmarking parameters for viable and early-stage non-viable cartilage. The interrelationships between these characteristics, examined using a multivariate analysis based on principal components analysis, multiple linear regression and general linear modeling, could then to deter- mine those parameters and relationships which have the potential to be developed into a future clinical device. Specifically, this research has found that the ultrasound and near infrared techniques can subsume the mechanical parameters and combine to characterise the tissue at the molecular, structural and mechanical levels over the full depth of the cartilage matrix. It is the opinion in this thesis that by enabling the determination of the precise area of in uence of a focal defect or disease in the joint, demarcating the boundaries of articular cartilage with dierent levels of degeneration around a focal defect, better surgical decisions that will advance the processes of joint management and treatment will be achieved. Providing the basis for a surgical tool, this research will contribute to the enhancement and quanti�cation of arthroscopic procedures, extending to post- treatment monitoring and as a research tool, will enable a robust method for evaluating developing (particularly focalised) treatments.