985 resultados para Subinertial frequencies


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A clinical study of Brazilian patients with neurofibromatosis type 1 (NF1) was performed in a multidisciplinary Neurofibromatosis Program called CEPAN (Center of Research and Service in Neurofibromatosis). Among 55 patients (60% females, 40% males) who met the NIH criteria for the diagnosis of NF1, 98% had more than six café-au-lait patches, 94.5% had axillary freckling, 45% had inguinal freckling, and 87.5% had Lisch nodules. Cutaneous neurofibromas were observed in 96%, and 40% presented plexiform neurofibromas. A positive family history of NF1 was found in 60%, and mental retardation occurred in 35%. Some degree of scoliosis was noted in 49%, 51% had macrocephaly, 40% had short stature, 76% had learning difficulties, and 2% had optic gliomas. Unexpectedly high frequencies of plexiform neurofibromas, mental retardation, learning difficulties, and scoliosis were observed, probably reflecting the detailed clinical analysis methods adopted by the Neurofibromatosis Program. These same patients were screened for mutations in the GAP-related domain/GRD (exons 20-27a) by single-strand conformation polymorphism. Four different mutations (Q1189X, 3525-3526delAA, E1356G, c.4111-1G>A) and four polymorphisms (c.3315-27G>A, V1146I, V1317A, c.4514+11C>G) were identified. These data were recently published.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Transcutaneous electrical nerve stimulation (TENS) is a type of therapy used primarily for analgesia, but also presents changes in the cardiovascular system responses; its effects are dependent upon application parameters. Alterations to the cardiovascular system suggest that TENS may modify venous vascular response. The objective of this study was to evaluate the effects of TENS at different frequencies (10 and 100 Hz) on venous vascular reactivity in healthy subjects. Twenty-nine healthy male volunteers were randomized into three groups: placebo (n=10), low-frequency TENS (10 Hz, n=9) and high-frequency TENS (100 Hz, n=10). TENS was applied for 30 min in the nervous plexus trajectory from the superior member (from cervical to dorsal region of the fist) at low (10 Hz/200 μs) and high frequency (100 Hz/200 μs) with its intensity adjusted below the motor threshold and intensified every 5 min, intending to avoid accommodation. Venous vascular reactivity in response to phenylephrine, acetylcholine (endothelium-dependent) and sodium nitroprusside (endothelium-independent) was assessed by the dorsal hand vein technique. The phenylephrine effective dose to achieve 70% vasoconstriction was reduced 53% (P<0.01) using low-frequency TENS (10 Hz), while in high-frequency stimulation (100 Hz), a 47% increased dose was needed (P<0.01). The endothelium-dependent (acetylcholine) and independent (sodium nitroprusside) responses were not modified by TENS, which modifies venous responsiveness, and increases the low-frequency sensitivity of α1-adrenergic receptors and shows high-frequency opposite effects. These changes represent an important vascular effect caused by TENS with implications for hemodynamics, inflammation and analgesia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pyruvate dehydrogenase (PDH) plays an important role in regulating carbohydrate oxidation in skeletal muscle. PD H is deactivated by a set of PD H kinases (PD K 1-4) with PDK2 and 4 being the predominant isoforms in skeletal muscle. PDK2 is highly sensitive to pyruvate inhibition, and is the most abundant isoform, while PDKI and 4 protein content are normally lower. This study examined the PDK isoform content and PDHa activation in muscle at rest and 10 and 40 Hz stimulation from PDK2 knockout (PDK2KO) mice to delineate the role of PDK2 in activating the PDH complex during low and moderate intensity muscle contraction. PDHa activity was lower in PDK2KO mice during contraction while total PDK actitvity was -4 fold lower. PDK4 protein was not different, however PDKI partially compensated for the lack of PDK2 and was -56% higher than WT. PDKI is a very potent inhibitor of the PDH complex due to its phosphorylation site specificity and allosteric regulation. These results suggest that the site specificity and allosteric regulatory properties of the individual PDK isoforms are more important than total PDK activity in determining transformation of the complex and PDHa activity during acute muscle contraction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A dual-port microstrip antenna with a crescent shaped patch with excellent isolation betwecn the ports has been reportcd [I]. Since circular-sided geometries are inore compact than rectangular oncs, thcy find morc applications in microstrip arrays. The crcscent shaped antenna geometry [ I ] provides greater area rcductioii compared to other circular sided patches for broadband operation [2]. In this Lctter, formulac for calculating thc TM, I and TMZI mode resonant frequencies of this microstrip antenna, obtained by modifying the equations of a standard circular patch [3] are presentcd. Thcorctical results are compared with experimental observations aid the validity of the computation is established.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The arrow shaped microstrip antenna, which produces dual frequency dual polarisation operation with considera-ble size reduction compared to conventional patches has been reported [I]. These antennas provide greater area reduction and improved gain compared to drum shaped patches [2]. Prediction of the resonance frequency of drum shaped patches [3] and circular patches for broadband operation [4] are available in the literature. In this Letter, we propose empirical formulas for calculating the resonance frequencies of the arrow shaped microstrip antenna. These antennas can be employed for obtaining dual frequency with the same polarisation, bandwidth enhancement, circular polarisation etc. by varying its different parameters or by introducing slots. The proposed design equations provide an easier and simple way of predicting the resonant frequencies of these patches.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dielectric properties of polyaniline at different frequencies were studied. Cavity perturbation technique was employed for the study. Poly aniline in the powder and pelletised forms were prepared under different environmental conditions. Different samples of poly aniline exhibit high conductivity. However, the conductivity of samples prepared under different environmental conditions is found to vary. All the samples in the powder form have high conductivity irrespective of the method of preparation. The high conductivity at microwave frequency makes it possible to be used for developing microwave components like filters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple technique for calculating the resonance frequencies of a compact arrow-shaped microstrip antenna is presented and discussed . The accuracy of the method is validated by experimental results

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hydroxyapatite (HAp, Ca10(PO4)6(OH)2) bioceramic and chitosan (poly [( -1-4) D-glucosamine]) biopolymer show good biocompatibility in vivo. They have biological origin and show excellent interactions with microwave. Microwave study of HAp made using different drying techniques and their composites with chitosan in the ISM band is presented. Pastes are made using HAp and chitosan with different ratios of mixing. The dielectric properties of this composites match with that of human fat, collagen tissues. Some of the compositions exhibit dielectric property close to that of natural bone. This makes them more biocompatible and better substitutes for natural bone. Thus composite bioceramics can be considered as phantom model constituents for imaging purposes. Their dielectric properties prove that they are biocompatible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article reports a new method of analyzing pericardial fluid based on the measurement of the dielectric properties at microwave frequencies. The microwave measurements were performed by rectangular cavity perturbation method in the S-band of microwave frequency with the pericardial fluid from healthy persons as well as from patients suffering from pericardial effusion. It is observed that a remarkable change in the dielectric properties of patient samples with the normal healthy samples and these measurements were in good agreement with clinical analysis. This measurement technique and the method of extraction of pericardial fluid are simple. These results give light to an alternative in-vitro method of diagnosing onset pericardial effusion abnormalities using microwaves without surgical procedure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dielectric properties of polyaniline at different frequencies were studied. Cavity perturbation technique was employed for the study. Poly aniline in the powder and pelletised forms were prepared under different environmental conditions. Different samples of poly aniline exhibit high conductivity. However. the conductivity of samples prepared under different environmental conditions is found to vary. All the samples in the powder form have high conductivity irrespective of the method of preparation. The high conductivity at microwave frequency makes it possible to be used for developing microwave components like filters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the medical field, microwaves play a larger role for treatment than diagnosis. For the detection of diseases by microwave methods, it is essential to know the dielectric properties of biological materials. For the present study, a cavity perturbation technique was employed to determine the dielectric properties of these materials. Rectangular cavity resonators were used to measure the complex permittivity of human bile, bile stones, gastric juice and saliva. The measurements were carried out in the S and J bands. It is observed that normal and infected bile have different dielectric constant and loss tangent. Dielectric constant of infected bile and gastric juice varies from patient to patient. Detection and extraction of bile stone with possible method of treatment is also discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ionic polymers (ionomers) with interesting characteristics are emerging as important commercial polymers. Ionomers have the unique ability to behave as cross-linked materials at ambient temperatures and to melt and flow at elevated temperatures like thermoplastics. The complex permittivity and conductivity of a class of ionomers at microwave frequencies are determined using the cavity perturbation technique and the results are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we discuss our research in developing general and systematic method for anomaly detection. The key ideas are to represent normal program behaviour using system call frequencies and to incorporate probabilistic techniques for classification to detect anomalies and intrusions. Using experiments on the sendmail system call data, we demonstrate that we can construct concise and accurate classifiers to detect anomalies. We provide an overview of the approach that we have implemented

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple approach for accurate determination of the resonant frequencies of microstrip antennas of regular geometries is developed and presented. In this approach, a generalised empirical formula for the computation of effective dielectric permittivity is given which takes into account the ratio of the fringing area to the area of the patch. A correction to the equivalent side length of an equilateral triangular patch, previously published, is modified and a new formula is given. A correction to the effective dimensions of an elliptical microstrip antenna is also carried out. Numerical results obtained for the resonant frequencies of elliptical, circular, rectangular and equilateral-triangular microstrip antennas are in good agreement with the available theoretical and experimental results reported by others. The present approach is more efficient, simpler and more accurate

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The remarkable difference between the nuclear quadrupole frequencies v_Q of Cu(1) and Cu(2) in YBa_2Cu_3O_6 and YBa_2Cu_3O_7 is analyzed. We calculate the ionic contribution to the electric field gradients and estimate, by using experimental results for Cu_2O and La_2CuO_4, the contribution of the d valence electrons. Thus, we determine v_Q1, v_Q2, and the asymmetry parameter η for YBa_2Cu_3O_6 and YBa_2Cu_3O_7. The number of holes in dthe Cu-O planes and chains is found to be important for the different behavior of v_Q1 and v_Q2.