966 resultados para Structural behaviour


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The number of dams, which need rehabilitation, is growing, not only in countries that have a long tradition in dam building and operation but,also in those regions where the infrastructure is still in full development. Though rehabilitation projects generally deal with problems that are common in dam engineering practice there are some peculiarities which are a characteristic of such projects and which must be duly taken into account to avoid unsuccess and/or unnecessary costs. Regular safety inspection is essential to forestall the development of structural, hydrological and operational unsafety. if need of major repair or overall rehabilitation of a dam becomes apparent design oft he rehabilitation project must be preceded by a comprehensive checkup of the structure and appurtenant works, as well as by an evaluation of its hydrological safety inclusive of all relevant environmental aspects. The availability of complete records on the clam's structural behaviour and on meteorological and hydrological data, as well as the knowledge of the materials properties of the existing structure are important for the successful design of a rehabilitation project. To this end the installation of monitoring devices in the existing structure may be necessary to generate representative data. While the criteria to be used in structural design should correspond to current standards, the definition of hydrological design criteria depends on considerations that vary widely from region to region or even from one country to another. Some basic hydrological safety requirements, however, are recommended for general acceptance. Dam rehabilitation projects demand very careful and detailed construction planning because of their dependence on river flow conditions, operational restrictions and, often, on procedures or limitations imposed to avoid harm to the environment. of utmost importance is the timely availability of the financial funds required to complete the project, in order to avoid delays which could result in structural or operational unsafety. Since every dam sooner or later will have to undergo major repair or updating of safety, rehabilitation may evolve to a speciality of dam engineering.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this research study was to evaluate the structural behaviour of the wood and concrete composite system for bridge decks with emphasis on the metal shear connectors. Experimental tests were performed on composite specimens and wood and concrete beams with a metallic connector system in an X position, using CS100900-type screws. All specimens and beams were submitted to static loads until failure in order to obtain the strength and stiffness of the connection system. The experimental results for the stiffness of the beams were compared with the analytical results obtained through the Mohler model, presenting good equivalence for service loads. The experimental results obtained demonstrate that the most significant damage in composite systems occurred in the connectors' areas.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In the present study, a new pushover procedure for 3D frame structures is proposed, based on the application of a set of horizontal force and torque distributions at each floor level; in order to predict the most severe configurations of an irregular structure subjected to an earthquake, more than one pushover analysis has to be performed. The proposed method is validated by a consistent comparison of results from static pushover and dynamic simulations in terms of different response parameters, such as displacements, rotations, floor shears and floor torques. Starting from the linear analysis, the procedure is subsequently extended to the nonlinear case. The results confirm the effectiveness of the proposed procedure to predict the structural behaviour in the most severe configurations.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The purpose of this thesis is to further the understanding of the structural, electronic and magnetic properties of ternary inter-metallic compounds using density functional theory (DFT). Four main problems are addressed. First, a detailed analysis on the ternary Heusler compounds is made. It has long been known that many Heusler compounds ($X_2YZ$; $X$ and $Y$ transition elements, $Z$ main group element) exhibit interesting half-metallic and ferromagnetic properties. In order to understand these, the dependence of magnetic and electronic properties on the structural parameters, the type of exchange-correlation functional and electron-electron correlation was examined. It was found that almost all Co$_2YZ$ Heusler compounds exhibit half-metallic ferromagnetism. It is also observed that $X$ and $Y$ atoms mainly contribute to the total magnetic moment. The magnitude of the total magnetic moment is determined only indirectly by the nature of $Z$ atoms, and shows a trend consistent with Slater-Pauling behaviour in several classes of these compounds. In contrast to experiments, calculations give a non-integer value of the magnetic moment in certain Co$_2$-based Heusler compounds. To explain deviations of the calculated magnetic moment, the LDA+$U$ scheme was applied and it was found that the inclusion of electron-electron correlation beyond the LSDA and GGA is necessary to obtain theoretical description of some Heusler compounds that are half-metallic ferromagnets. The electronic structure and magnetic properties of substitutional series of the quaternary Heusler compound Co$_2$Mn$_{1-x}$Fe$_x$Si were investigated under LDA+$U$. The calculated band structure suggest that the most stable compound in a half-metallic state will occur at an intermediate Fe concentration. These calculated findings are qualitatively confirmed by experimental studies. Second, the effect of antisite disordering in the Co$_2$TiSn system was investigated theoretically as well as experimentally. Preservation of half-metallicity for Co$_2$TiSn was observed with moderate antisite disordering and experimental findings suggest that the Co and Ti antisites disorder amounts to approximately 10~% in the compound. Third, a systematic examination was carried out for band gaps and the nature (covalent or ionic) of bonding in semiconducting 8- and 18-electron or half-metallic ferromagnet half-Heusler compounds. It was found that the most appropriate description of these compounds from the viewpoint of electronic structures is one of a $YZ$ zinc blende lattice stuffed by the $X$ ion. Simple valence rules are obeyed for bonding in the 8- and 18-electron compounds. Fourth, hexagonal analogues of half-Heusler compounds have been searched. Three series of compounds were investigated: GdPdSb, GdAutextit{X} (textit{X} = Mn, Cd and In) and EuNiP. GdPdSb is suggested as a possible half-metallic weak ferromagnet at low temperature. GdAutextit{X} (textit{X} = Mn, Cd and In) and EuNiP were investigated because they exhibit interesting bonding, structural and magnetic properties. The results qualitatively confirm experimental studies on magnetic and structural behaviour in GdPdSb, GdAutextit{X} (textit{X} = Mn, Cd and In) and EuNiP compounds. ~

Relevância:

60.00% 60.00%

Publicador:

Resumo:

L'obiettivo della tesi è stato quello di indagare il complesso problema della vulnerabilità sismica dei ponte in muratura ad arco utilizzando modelli semplificati. Dopo una descrizione dei materiali da costruzione impiegati nella realizzazione e dei principali elementi dei un ponti in muratura, si è indirizzato lo studio di un ponte ad arco situato nel comune di San Marcello Pistoiese. Viene mostrato un modello numerico che permette di descrivere il comportamento strutturale del ponte sotto azione sismica e di valutare la capacità di carico del ponte sottoposto ad una azione trasversale. In un secondo momento viene descritta la realizzazione di un modello in scala del ponte, che è stato sottoposto a prove distruttive effettuate per valutare la capacità di carico del ponte rispetto ad un ipotetica azione orizzontale. Si è cercato poi di inquadrare il problema in un modello teorico che faccia riferimento all'analisi limite. Esso descrive un cinematismo di collasso a telaio che prende spunto dal quadro fessurativo del modello in muratura. Infine sono stati presentati modelli FEM numerici in ordine di complessità crescente, cercando di inquadrare il comportamento meccanico del prototipo del ponte. Tre tipi di modelli sono rappresentati: un telaio incernierato alle estremità costituito da elementi beam con resistenza alla flessione . Il secondo tipo è costituito da una reticolare equivalente che mima lo schema del ponte ed è formato solo da bielle. Infine, il terzo tipo cerca di descrivere l'intero modello con elementi tridimensionali.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this thesis is the elucidation of structure-properties relationship of molecular semiconductors for electronic devices. This involves the use of a comprehensive set of simulation techniques, ranging from quantum-mechanical to numerical stochastic methods, and also the development of ad-hoc computational tools. In more detail, the research activity regarded two main topics: the study of electronic properties and structural behaviour of liquid crystalline (LC) materials based on functionalised oligo(p-phenyleneethynylene) (OPE), and the investigation on the electric field effect associated to OFET operation on pentacene thin film stability. In this dissertation, a novel family of substituted OPE liquid crystals with applications in stimuli-responsive materials is presented. In more detail, simulations can not only provide evidence for the characterization of the liquid crystalline phases of different OPEs, but elucidate the role of charge transfer states in donor-acceptor LCs containing an endohedral metallofullerene moiety. Such systems can be regarded as promising candidates for organic photovoltaics. Furthermore, exciton dynamics simulations are performed as a way to obtain additional information about the degree of order in OPE columnar phases. Finally, ab initio and molecular mechanics simulations are used to investigate the influence of an applied electric field on pentacene reactivity and stability. The reaction path of pentacene thermal dimerization in the presence of an external electric field is investigated; the results can be related to the fatigue effect observed in OFETs, that show significant performance degradation even in the absence of external agents. In addition to this, the effect of the gate voltage on a pentacene monolayer are simulated, and the results are then compared to X-ray diffraction measurements performed for the first time on operating OFETs.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Se trata de un proyecto de pasarela peatonal colgante sobre el río Ulla, de aproximadamente 36 metros de luz. La especial belleza del área natural en que se situará llevó a la opción de un diseño claro y sencillo para lograr su integración en el lugar. Se busca que la pasarela pase lo más desapercibida posible y deje el protagonismo para el entorno, el río y la naturaleza misma. La difícil accesibilidad de la zona condicionó el diseño y los procedimientos constructivos a adoptar. Se optó por una tipología de pasarela colgante de cables de acero, tablero de madera de castaño y soportes de madera laminada cilíndrica, sobre unos estribos de hormigón armado parcialmente ocultos gracias a su integración en la topografía del lugar. El diseño modular del tablero, construido a base de piezas prefabricadas de madera de castaño que se ensamblan entre sí, permite el montaje en seco mediante avance del tablero sin necesidad de cimbra. Su diseño con dos capas cruzadas de entablado solidarizadas proporciona al conjunto un comportamiento estructural similar al de una placa maciza de madera. This is the project of a suspension footbridge over the Ulla River. It has a span of about 36 meters. The beauty of the natural surroundings where it is located guided the design to the option of a clear and simple proposal with the aim of achieving an integrated project for the area. The footbridge tries to be as invisible as possible with the purpose of maintaining the natural quality of the river and its surroundings. The difficult access to the area conditioned the design and the construction procedures chosen. A suspension footbridge with stainless steel cables, chestnut timber deck and cylindrical glulam piles was designed in the end. The reinforced concrete abutments are partially concealed thanks to their integration in the topography of the area. The deck is built of prefabricated chestnut timber modules that can be joined together at the construction site and can be assembled without the necessity of scaffolding over the river. The design of the deck, with two crossed layers of chestnut boards screwed down together, permits a structural behaviour similar to a solid wooden slab.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

La durabilidad de las estructuras de hormigón armado no es ilimitada, en especial en determinados ambientes. El ingreso de agentes agresivos en el hormigón, fundamentalmente dióxido de carbono e iones cloruros, rebasando el espesor del recubrimiento y alcanzando las armaduras, reducen el alto pH del hormigón hasta alcanzar un umbral crítico, por debajo del cual, el acero queda despasivado. Posteriormente, si existe el suficiente aporte de humedad y oxígeno, el acero se corroe, lo que supone drásticas reducciones de la vida de servicio de estas estructuras y su inevitable reparación. La utilización de armaduras de acero inoxidable es una alternativa que está recibiendo cada vez más consideración. Su resistencia a la corrosión en los ambientes más agresivos, incluso con ataque de cloruros, lo convierte en el material idóneo para prolongar de forma muy considerable la vida útil de la estructura. En este trabajo se ha evaluado el comportamiento mecánico y estructural, y de resistencia a la corrosión, de un nuevo acero inoxidable dúplex de bajo contenido en níquel, el EN 1.4482 (AISI 2001), y se ha comparado con el inoxidable austenítico más utilizado, el EN 1.4301 (AISI 304), con el dúplex EN 1.4362 (AISI 2304) y con el tradicional acero al carbono B-500-SD. El estudio mecánico y estructural se ha realizado en tres niveles diferentes: a nivel de barra, estudiando las propiedades mecánicas y de ductilidad de los cuatro aceros citados; a nivel de sección, estudiando su comportamiento a flexión con diferentes cuantías de armado por medio de los diagramas momento-curvatura; y a nivel de pieza, ensayando una serie de vigas armadas con diferentes aceros y cuantías, y comprobando su comportamiento a desplazamiento y resistencia por medio de los diagramas carga-desplazamiento. El estudio de resistencia a la corrosión se ha realizado embebiendo barras corrugadas, de los tres aceros inoxidables mencionados, en probetas de mortero contaminadas con diferentes cantidades de cloruros, y realizando mediciones electroquímicas durante un periodo de al menos un año. Se han preparado probetas de mortero para dos comparativas diferentes. La primera, manteniendo las probetas en un desecador con el 95 % de humedad relativa durante todo el periodo de mediciones. La segunda, sumergiendo parcialmente las probetas en una solución tampón para carbonatar el mortero. Los resultados de los ensayos mecánicos han demostrado dos aspectos diferentes. Uno, que las armaduras de acero inoxidable tienen un comportamiento muy similar a las de acero al carbono en lo referente a las resistencias alcanzadas, en el límite elástico y en rotura, pero distinto en cuanto al módulo de deformación longitudinal, cuyo valor es claramente inferior al del acero al carbono, por lo que su utilización en las estructuras de hormigón necesita tener en cuenta ese dato en los análisis lineales de cálculo. El segundo aspecto es que las armaduras de acero inoxidable laminadas en caliente presentan una ductilidad muy superior a las de acero al carbono, por lo que ofrecen una mayor seguridad frente a su rotura o al colapso de la estructura, lo que se debe tener en cuenta en el análisis de cálculo plástico. En cambio, las armaduras de acero inoxidable laminadas en frío sólo cumplen con los límites mínimos de ductilidad establecidos en la instrucción EHE-08 para los aceros soldables, y no para los aceros con características especiales de ductilidad. El estudio a nivel de sección refleja la paradoja de obtener secciones menos dúctiles con las armaduras de acero inoxidable laminadas en caliente que con las armaduras de acero al carbono. Para subsanarlo, se definen los conceptos de curvatura última de rotura y ductilidad de la sección en rotura, que tienen en cuenta las altas deformaciones alcanzadas por las armaduras de acero inoxidable. Los resultados a nivel de pieza permiten identificar el comportamiento estructural del hormigón armado con barras corrugadas de acero inoxidable y compararlo con el de las estructuras de hormigón armado convencionales, verificando los resultados experimentales con los teóricos obtenidos con la formulación recogida en la instrucción EHE- 08. Los ensayos de resistencia a la corrosión por cloruros demuestran, durante el primer año y medio de vida de las probetas, un comportamiento muy similar entre el nuevo acero inoxidable dúplex bajo en níquel y el austenítico y el dúplex utilizados para la comparación, incluso para las probetas carbonatadas. Por último, se añade una comparativa económica, realizada sobre dos edificaciones tipo, para cuantificar el sobrecoste que supone la utilización de armaduras de acero inoxidable respecto a las de acero al carbono. El alto coste inicial de las armaduras de acero inoxidable se ve compensado en el coste final de la estructura de muy diferentes formas, principalmente dependiendo del grado de acero elegido y de si se emplean en el total de la estructura o solamente en los elementos más expuestos. The durability of the concrete structures is limited, especially in certain environments. The attack of aggressive agents in the concrete, mainly carbon dioxide and chloride ions, penetrating the thickness of concrete cover and reaching the reinforcements, reduce the high pH of concrete to the point of reaching a critical threshold, under which, the steel despasivates. Therefore, if there is enough humidity and oxygen, the steel corroes, causing drastic reductions in the service life of these structures and its inevitable repair. Despite the high initial cost compared to carbon steel, the usage of stainless steel reinforcements is an alternative with a major consideration nowadays. Its resistance to corrosion in the most aggressive atmospheres, including chlorides attack, makes the stainless steel a suitable material to extend considerably its lifetime. In this study, it’s been evaluated the mechanical and structural behaviour, and the corrosion resistance, of a new low-nickel duplex stainless steel EN 1.4482 (AISI 2001), and it has been compared with the most widely used austenitic type EN 1.4301 (AISI 304), with duplex steel EN 1.4362 (AISI 2304) and with the traditional carbon steel B-500-SD. The mechanical and structural study has been carried out in three different levels: bar level, studying mechanical properties and ductility of the four steels; section level, studying its behaviour when blending with different amounts of reinforcement through the moment-curvature diagrams; and structural element level, testing a series of reinforced beams with different steels and amounts, and checking its sag and resistance through the load-deflection diagrams. The corrosion resistance study was performed by embedding ribbed bars, using the three stainless steel listed, on mortar specimens contaminated with different amounts of chlorides, and taking electrochemical measurements over a period of at least one year. Mortar specimens have been prepared for two different comparisons. The first, keeping the specimens at 95% of relative humidity during the measurement period. The second, immersing the specimens partially in a carbonate buffer solution. The results of those tests have proved two different aspects. Firstly, that stainless steel reinforcements show a very similar behaviour to carbon steel, according to the reached levels of mechanical resistance, yield stress and steel strength, but a different behaviour in Young’s modulus, which value is clearly lower than the carbon steel. Therefore, when using in concrete structures it is need to consider on that point the existing calculus of linear analysis. The second aspect is that stainless steel reinforcement manufactured by hot-rolling process show a very higher ductility than carbon steel, offering a better security on cracks or structure collapse, which it has to be taken into account on plastic calculus analysis. However, the stainless steel reinfor9 cement cold-rolled bars only meet the minimum thresholds of ductility established by EHE-08 for welded steel, and not for steels with special ductility. The results at the section level reflect the paradox of getting less ductile sections with hot rolled stainless steel reinforcement than with carbon steel reinforcements. To overcome that, the concepts of last break curvature and break ductility section have been defined, which take into account the high deformation value achieved by stainless steel reinforcements. The results at the structural element level allow to identify the structural behaviour of reinforced concrete with stainless steel reinforcements and compared with that of conventional steel reinforcement, contrasting the experimental with the theoretical results obtained from the formulation contained in the instruction EHE-08. Tests on resistance of chloride corrosion show during the first year and a half of specimens life, a similar behaviour between the new low nickel duplex stainless steel and austenitic and duplex used for comparison, even for carbonated specimens. Finally, it has been included an economic comparison on two differents building types, to quantify the additional cost involved on the use of stainless steel reinforcement compared to that of carbon steel. The high initial cost of stainless steel reinforcements is offset in the final cost of the structure in many different ways, mainly depending on the chosen steel grade and whether the reinforcement is used in the total structure or only in risky structural elements.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

El reciente desarrollo de la instrumentación diseñada para proporcionar datos de aceleraciones y movimientos del cajón número 8 del dique Botafoc (Ibiza), perteneciente a la Autoridad Portuaria de Baleares (Puertos del Estado), en conjunción con datos procedentes de una instrumentación compuesta por sensores de presión existente en el paramento vertical, proporciona un novedoso medio para analizar la respuesta estructural del cajón, no sólo ante la acción del oleaje, sino también ante los efectos producidos por las maniobras de los buques en el muelle. Como la medición de estas aceleraciones y velocidades angulares se hace a altas frecuencias (de hasta 400 Hz), podemos proporcionar datos válidos acerca del comportamiento estructural y de los movimientos reales del cajón, tratando de correlacionar este comportamiento con los resultados obtenidos por el grupo de trabajo PROVERBS (Probabilistic design of vertical breakwaters, MAST III EU Programme), y generando una base de datos estadística de movimientos que deben considerarse para enriquecer los conocimientos en este ámbito. Además, la posibilidad de registrar los efectos causados por las maniobras de atraquedesatraque-estancia de los buques, abre un nuevo punto de vista al diseño estructural de un dique-muelle, siendo también de gran interés para los diseñadores de obras marítimas y para la correcta definición de las maniobras del buque en el muelle. The recent deployment of new instrumentation designed to provide accelerations and angular velocities from caisson #8 at Botafoc seawall, Ibiza, along with an existing pressure sensor instrumentation at the vertical wall, provides a way to record and process data of the structural response, not only to waves, but also to effects caused by ship mooring operations at Botafoc seawall. As the measurement of these angular speeds and accelerations is programmed with sampling frecuencies up to 400 Hz, and by integrating all data through time we may provide suitable data of the structural behaviour of the caisson. This behaviour is tried to be correlated with the PROVERBS working group achievements (Probabilistic design of vertical breakwaters, MAST III EU Programme), generating a statistical movement database that must be used to improve knowledge on this subject. Also the possibility to record the effects caused by the different ship mooring operations is a new point of view of the complete structural design of a seawall-wharf, which is considered an interesting matter for coastal designers as well for a correct ship mooring processes definition.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Los puentes arco de fábrica representan una parte importante del inventario de puentes en España y en Europa. De aquí, la importancia cuantitativa de estas estructuras y el interés que representa tanto para las Administraciones, organismos públicos y privados como para la sociedad en general, mantener estos puentes en servicio. Para poder alargar su vida útil, aún más si cabe, se plantea imprescindible llevar a cabo una labor de conservación y mantenimiento adecuada. La importancia de la evaluación estructural de los puentes de fábrica se basa en la conveniencia de conocer el comportamiento estructural tanto en condiciones de servicio como en agotamiento. El comportamiento en Estado Límite Último ha sido estudiado en profundidad y como resultado, la seguridad frente a agotamiento ha quedado definida con cierta confianza. Sin embargo, el comportamiento en Estado Límite de Servicio no es tan conocido. Se considera necesaria una revisión del concepto de ELS en puentes arco de fábrica puesto que muchos de ellos, cumpliendo las comprobaciones establecidas para ELU, presentan daños asociados a las actuales condiciones de explotación existentes actuales. El presente trabajo se enmarca dentro de un proyecto que está llevando a cabo la UIC (Union Internationale de Chemins de Fer) desde 2004. El objetivo general del mismo es conocer el comportamiento de los puentes arco de fábrica y mejorar los métodos de evaluación, mantenimiento y reparación existentes. Con este estudio, se pretende contribuir a mejorar la caracterización del comportamiento en servicio de estas estructuras. Para ello se ha realizado un análisis del estado tensional de la bóveda y el relleno estudiando la influencia de la configuración geométrica de los puentes y las propiedades de los materiales que los componen. Entender el funcionamiento de estas estructuras y conocer sus peculiares características ha sido el paso previo al desarrollo del estudio. Para ello, se ha acudido al minucioso trabajo desarrollado por diversos autores, desde los primeros análisis mediante la línea de presiones hasta los actuales métodos basados en elementos finitos. En primer lugar, se ha realizado un estudio paramétrico de diferentes configuraciones geométricas. El objetivo es comprobar la influencia de las dimensiones absolutas y las relaciones existentes entre las mismas en el comportamiento en servicio de los puentes. A continuación, se ha estudiado la influencia de las propiedades mecánicas de los rellenos rígido y granular (modificando su módulo de deformabilidad) en el estado tensional de la bóveda y el propio relleno. Para las dos etapas anteriores se emplea un modelo simplificado de puente arco de fábrica. A continuación, se crea un modelo más completo del mismo, para estudiar la influencia de las propiedades mecánicas del substrato de cimentación en el comportamiento estructural en servicio de la estructura. El objetivo final de este trabajo fin de máster, es conocer el comportamiento en servicio de los puentes arco de fábrica, para poder establecer las variables que condicionan el mismo. El siguiente paso en este campo de estudio, consiste en fijar unos valores límite para las mismas. Como síntesis de las conclusiones obtenidas, se menciona que el comportamiento estructural de los puente arco de fábrica, en mayor o menor medida, está influenciado por su geometría y las propiedades de los rellenos y substrato de cimentación que forman parte del mismo. Masonry arch bridges represent an important part of the total bridges, both in Spain and Europe. For this reason, these structures are so important in terms of quantity. They play an essential role for public administration and people in general. In order to remain those bridges serviceable, suitable inspections and repairs are required. It is necessary to have knowledge of the bridge condition so that an assessment can be made with confidence. It is therefore necessary to check that bridges behave properly under Ultimate Limit State criterion and Serviceability Limit State criterion. ULS has been studied thoroughly and as result, requirements under collapse are well described. However, structural behaviour under conditions of serviceability is not well evaluated. Serviceability Limit State criterion should be redefined for masonry arch bridges assessment. This is because many bridges that fulfil SLS criterion have damages. The purpose of this work is to take part in the improvement of assessment under serviceability. A vault and fill structural behaviour analysis has been performed from two points of view: geometry of the bridge and materials’ properties. The starting point was learning about masonry arch bridges behaviour and their special features. For this task, a revision of several authors’ thorough study has been made, from the line of thrust analysis to the current finite element analysis. Firstly, a parametric study of typologies of bridge has been made. The aim is to know how vault and fill behaviour changes modifying both absolute dimensions and relation between them. In the next step, a study of both surface fill and backfill properties has been done. The aim is to know how vault and fill behaviour changes modifying Young’s modulus. The principal conclusion achieved along this work is that the structural behaviour of masonry bridges depends of the bridge geometry and its material properties.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Las estructuras de hormigón son susceptibles de sufrir los efectos asociados a las acciones de fatiga cuando estas se ven sometidas a un elevado número de cargas repetidas. Muchas de estas estructuras no requieren armadura transversal para cumplir los condicionantes de dimensionamiento estático como por ejemplo las losas superiores de tableros de puentes, los muros de contención, las losas de transición de puentes, las torres eólicas o las estructuras marítimas. La mayor parte de los códigos de diseño vigentes no incluyen una comprobación específica del nivel de seguridad a cortante de estas estructuras para acciones de fatiga, y aquellas que lo hacen prefieren utilizar expresiones de tipo empírico basadas en curvas S-N que relacionan el número de ciclos resistentes con el valor de la carga aplicada. A pesar de que el empleo de curvas S-N es de gran utilidad desde un punto de vista práctico, estas curvas no permiten comprender el proceso de rotura por cortante para cargas repetidas. El objetivo principal de esta Tesis es el de estudiar el comportamiento a cortante de elementos de hormigón armado sin cercos sometidos a fatiga. Además, el análisis es ampliado al estudio del comportamiento transversal de los voladizos de las losas superiores de tableros de puentes de hormigón que de forma habitual son diseñados sin armadura de cortante. De forma habitual estos elementos se diseñan atendiendo a criterios de dimensionamiento estáticos sin tener en cuenta la resistencia a cortante cuando se ven sometidos a cargas cíclicas. A pesar de que las cargas de fatiga son inferiores a aquellas que producen el fallo estático, es importante tener en cuenta el comportamiento de estos elementos ante cargas repetidas. Los trabajos experimentales existentes en vigas de hormigón armado sin cercos evidenciaron diferencias significativas entre los modos de fallo ante cargas estáticas y cíclicas. Estos trabajos llegaron a la conclusión de que estos elementos diseñados para tener un fallo dúctil por flexión pueden llegar a desarrollar un tipo de fallo frágil por cortante cuando se ven sometidos a cargas repetidas. El proceso de rotura por cortante en elementos de hormigón armado sin cercos sometidos a fatiga es un proceso complejo que debe ser estudiado en profundidad debido al carácter frágil de este tipo de fallo. Los trabajos experimentales permitieron comprobar que el origen de este fallo tiene lugar tras la formación de una fisura de cortante a partir de una fisura de flexión formada durante los primeros ciclos en el vano de cortante. Tras la formación de esta fisura, esta se va propagando hacia la cabeza de compresión hasta que finalmente se produce el fallo como consecuencia de la destrucción de la cabeza de compresión cuando la altura alcanzada por esta es insuficiente para resistir la fuerza de compresión aplicada en esta zona. Por otra parte, la propagación de esta fisura diagonal puede desarrollarse por completo en el instante en el que esta se forma derivando en un tipo de fallo por cortante más frágil que el anterior. El proceso de fatiga es estudiado en esta Tesis mediante un modelo mecánico. Por una parte, se propone un modelo predictivo para determinar el número de ciclos acumulados hasta que se forma la fisura diagonal en función del estado tensional que se tiene en la punta de una fisura crítica de flexión formada en los primeros ciclos. Por otra parte, la resistencia a fatiga tras la formación de la fisura diagonal se analiza teniendo en cuenta el daño por fatiga acumulado en la cabeza de compresión y las variables que afectan a la propagación de esta fisura de cortante. Para la evaluación de la resistencia a fatiga tras la formación de la fisura crítica de cortante en este tipo de elementos, se plantea un modelo teórico basado en conceptos de Mecánica de la Fractura adaptados al hormigón. Este modelo puede ser aplicado a vigas de hormigón armado sin cercos de canto constante o variable siguiendo diferentes procedimientos. Una campaña experimental ha sido llevada a cabo con el objetivo de estudiar el comportamiento a cortante de vigas de hormigón armado sin cercos de canto variable sometidas a cargas estáticas y de fatiga. Se han desarrollado un total de diez ensayos estáticos y de fatiga para diferentes niveles de carga y esbelteces de cortante, teniendo lugar diferentes modos de fallo. Estos elementos fueron diseñados para reproducir, a escala real y de forma simplificada, los voladizos laterales de las losas superiores de tableros de puentes de carretera de hormigón. Los resultados experimentales demostraron que el tipo de fallo desarrollado depende de varios parámetros como por ejemplo el nivel de carga máxima, el nivel de oscilación de tensiones en la armadura longitudinal, la esbeltez de cortante o la calidad del hormigón utilizado entre otros. Para valores similares de esbeltez de cortante, los ensayos de fatiga realizados permitieron comprobar que la rotura por cortante de estos elementos está asociada a niveles de carga máxima elevados, mientras que el fallo por fatiga de la armadura longitudinal tiene mayor probabilidad de ocurrir en elementos sometidos a elevados niveles de oscilación de tensiones en esta armadura. Además, estos ensayos han sido analizados a través del modelo propuesto para tratar de comprender el comportamiento resistente de estos elementos sometidos a cargas de fatiga. Concrete structures are able to suffer fatigue when they are subjected to high number of cyclic loads. Many of these need not shear reinforcement to satisfy static design requirements, such as bridge deck slabs, retaining walls, bridge approach slabs, wind towers or maritime structures among others. Many codes of practice do not include a verification of the shear fatigue safety. Moreover, those which include it still prefer empirical S-N-based approaches that provide the number of cycles as a function of applied forces. S-N models are practical but they do not provide information to understand the shear fatigue process. The main objective of this Thesis is to study shear behaviour of reinforced concrete elements without stirrups subjected to fatigue loads. In addition, the analysis is extended in order to study the transverse behaviour of cantilever slabs of concrete bridges that traditionally are designed without shear reinforcement. These elements usually are designed on the basis of static strength and it is unusual that codes consider fatigue strength of concrete in shear. Accordingly, it is important to take into account the fatigue behaviour of structural members subjected to cyclic loads although these loads are lower than those which produce the static failure. Existing experimental works show important differences between the static and cyclic failure modes of reinforced concrete beams without stirrups. These works concluded that beams without transverse reinforcement, designed to have a ductile failure mode in flexure, can submit a brittle shear failure mode when they are subjected to repeated loads. Shear fatigue failure of reinforced concrete beams without stirrups is a rather complex process from the mechanical viewpoint. Since it leads to a brittle failure mode it should be better understood. Experimental evidence indicates that a diagonal crack first develops from the inclination of flexural cracks in the shear span. Thereafter, the diagonal crack propagates into the compression zone. Failure normally takes place by the destruction of the compression zone when its depth is too small to resist the applied force. The propagation of the diagonal crack can also be instantaneous, leading to sudden diagonal cracking fatigue failure rather than shear-compression failure. Fatigue process is studied in this Thesis on a mechanical basis. On the one hand, a predictive model is derived to obtain the number of cycles up to diagonal cracking, as a function of the stress state at the tip of a critical flexural crack. On the other hand, the residual fatigue strength after diagonal cracking is analyzed taking into account the fatigue damage accumulated by the compression zone and the variables affecting the propagation of the diagonal crack. In order to assess the residual fatigue strength after diagonal cracking of such elements, a theoretical model is proposed based on concepts from fracture mechanics adapted to concrete. This model can be successfully applied for straight or haunched reinforced concrete beams without stirrups following different procedures. In order to achieve a more advanced knowledge in this subject, an experimental campaign has been carried out with the aim of study the shear behaviour of reinforced concrete haunched beams without stirrups subjected to static and fatigue loads. A total of ten static and fatigue tests have been performed with distinct load levels and shear span-to-depth ratios, presenting different failures modes. These elements were designed to reproduce in a simplified form the cantilever slab of concrete bridges at real scale. Experimental results showed that the type of failure depends on several parameters as for example the maximum load level, the stress oscillation level on the longitudinal reinforcement, the shear span-to-depth ratio or the quality of the concrete used among others. For a similar value of the shear span-to-depth ratio, tests evidenced that shear fatigue failure is related to high maximum load levels, while steel fatigue failure is easier to occur in elements subjected to high stress oscillation level on the reinforcement bars. Besides, these tests have been analyzed through the proposed model in order to clarify the structural behaviour of such elements subjected to fatigue loads.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The interest for modelling of human actions acting on structures has been recurrent since the first accidents on suspension bridges in the nineteenth century such as Broughton (1831) in the U.K. or Angers (1850) in France. Stadiums, gymnasiums are other types of structure where human induced vibration is very important. In these structures a particular phenomenon appears such as the interaction personstructure (lock-in), the person-person synchronization, and the influence of the mass and damping of the people in the structural behaviour. This paper focuses on the latter topic. In order to evaluate these property modifications several tests have been carried out on a stand-alone building. For the test an electro-dynamic shaker was installed at a fixed point of the gym slab and different groups of people were located around the shaker. The dynamic characteristics of the structure without people inside have been calculated by two methods: using a three-dimensional finite element model of the building and by operational modal analysis. These calculated experimental and numerical values are the reference values used to evaluate the modifications in the dynamic properties of the structure.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Adobe is commonly found in Aveiro's ancient constructions. Preservation and rehabilitation of those constructions, some of them with architectural and historical interest, has been forgotten for many years. As a result, in Aveiro region, the majority of existing constructions in adobe is structurally weak, and, in several cases, they are in the threshold of ruin. Rehabilitation and/or strengthening urge. Despite some efforts has been made, a great difficulty for technicians working on the rehabilitation of these constructions relies on the lack of knowledge on adobe's mechanical behaviour. In fact, in order to properly describe the structural behaviour of those constructions, there is a need to investigate the mechanical behaviour of adobe. Hence, this paper is based on a study intended to characterise the behaviour of adobe brick units. Specimens were prepared from selected representative constructions of the Aveiro region. The prepared specimens were tested in order to evaluate their mechanical behaviour in compression and tension

Relevância:

60.00% 60.00%

Publicador:

Resumo:

En la presente investigación se analiza la causa del hundimiento del cuarto compartimento del Tercer Depósito del Canal de Isabel II el 8 de abril de 1905, uno de los más graves de la historia de la construcción en España: fallecieron 30 personas y quedaron heridas otras 60. El Proyecto y Construcción de esta estructura era de D. José Eugenio Ribera, una de las grandes figuras de la ingeniería civil en nuestro país, cuya carrera pudo haber quedado truncada como consecuencia del siniestro. Dado el tiempo transcurrido desde la ocurrencia de este accidente, la investigación ha partido de la recopilación de la información relativa al Proyecto y a la propia construcción de la estructura, para revisar a continuación la información disponible sobre el hundimiento. De la construcción de la cubierta es interesante destacar la atrevida configuración estructural, cubriéndose una inmensa superficie de 74.000 m2 mediante una sucesión de bóvedas de hormigón armado de tan sólo 5 cm de espesor y un rebajamiento de 1/10 para salvar una luz de 6 m, que apoyaban en pórticos del mismo material, con pilares también muy esbeltos: 0,25 m de lado para 8 m de altura. Y todo ello en una época en la que la tecnología y conocimiento de las estructuras con este "nuevo" material se basaban en buena medida en el desarrollo de patentes. En cuanto a la información sobre el hundimiento, llama la atención en primer lugar la relevancia de los técnicos, peritos y letrados que intervinieron en el juicio y en el procedimiento administrativo posterior, poniéndose de manifiesto la trascendencia que el accidente tuvo en su momento y que, sin embargo, no ha trascendido hasta nuestros días. Ejemplo de ello es el papel de Echegaray -primera figura intelectual de la época- como perito en la defensa de Ribera, de D. Melquiades Álvarez -futuro presidente del Congreso- como abogado defensor, el General Marvá -uno de los máximos exponentes del papel de los ingenieros militares en la introducción del hormigón armado en nuestro país-, que presidiría la Comisión encargada del peritaje por parte del juzgado, o las opiniones de reconocidas personalidades internacionales del "nuevo" material como el Dr. von Emperger o Hennebique. Pero lo más relevante de dicha información es la falta de uniformidad sobre lo que pudo ocasionar el hundimiento: fallos en los materiales, durante la construcción, defectos en el diseño de la estructura, la realización de unas pruebas de carga cuando se concluyó ésta, etc. Pero la que durante el juicio y en los Informes posteriores se impuso como causa del fallo de la estructura fue su dilatación como consecuencia de las altas temperaturas que se produjeron aquella primavera. Y ello a pesar de que el hundimiento ocurrió a las 7 de la mañana... Con base en esta información se ha analizado el comportamiento estructural de la cubierta, permitiendo evaluar el papel que diversos factores pudieron tener en el inicio del hundimiento y en su extensión a toda la superficie construida, concluyéndose así cuáles fueron las causas del siniestro. De los resultados obtenidos se presta especial atención a las enseñanzas que se desprenden de la ocurrencia del hundimiento, enfatizándose en la relevancia de la historia -y en particular de los casos históricos de error- para la formación continua que debe existir en la Ingeniería. En el caso del hundimiento del Tercer Depósito algunas de estas "enseñanzas" son de plena actualidad, tales como la importancia de los detalles constructivos en la "robustez" de la estructuras, el diseño de estructuras "integrales" o la vigilancia del proceso constructivo. Por último, la investigación ha servido para recuperar, una vez más, la figura de D. José Eugenio Ribera, cuyo papel en la introducción del hormigón armado en España fue decisivo. En la obra del Tercer Depósito se arriesgó demasiado, y provocó un desastre que aceleró la transición hacia una nueva etapa en el hormigón estructural al abrigo de un mayor conocimiento científico y de las primeras normativas. También en esta etapa sería protagonista. This dissertation analyses the cause of the collapse of the 4th compartment of the 3th Reservoir of Canal de Isabel II in Madrid. It happened in 1905, on April 8th, being one of the most disastrous accidents occurred in the history of Spanish construction: 30 people died and 60 were injured. The design and construction supervision were carried out by D. José Eugenio Ribera, one of the main figures in Civil Engineering of our country, whose career could have been destroyed as a result of this accident. Since it occurred more than 100 years ago, the investigation started by compiling information about the structure`s design and construction, followed by reviewing the available information about the accident. With regard to the construction, it is interesting to point out its daring structural configuration. It covered a huge area of 74.000 m2 with a series of reinforced concrete vaults with a thickness of not more than 5 cm, a 6 m span and a rise of 1/10th. In turn, these vaults were supported by frames composed of very slender 0,25 m x 0,25 m columns with a height of 8 m. It is noteworthy that this took place in a time when the technology and knowledge about this "new" material was largely based on patents. In relation to the information about the collapse, its significance is shown by the important experts and lawyers that were involved in the trial and the subsequent administrative procedure. For example, Echegaray -the most important intellectual of that time- defended Ribera, Melquiades Álvarez –the future president of the Congress- was his lawyer, and General Marvá -who represented the important role of the military engineers in the introduction of reinforced concrete in our country-, led the Commission that was put in charge by the judge of the root cause analysis. In addition, the matter caught the interest of renowned foreigners like Dr. von Emperger or Hennebique and their opinions had a great influence. Nonetheless, this structural failure is unknown to most of today’s engineers. However, what is most surprising are the different causes that were claimed to lie at the root of the disaster: material defects, construction flaws, errors in the design, load tests performed after the structure was finished, etc. The final cause that was put forth during the trial and in the following reports was attributed to the dilatation of the roof due to the high temperatures that spring, albeit the collapse occurred at 7 AM... Based on this information the structural behaviour of the roof has been analysed, which allowed identifying the causes that could have provoked the initial failure and those that could have led to the global collapse. Lessons have been learned from these results, which points out the relevance of history -and in particular, of examples gone wrong- for the continuous education that should exist in engineering. In the case of the 3th Reservoir some of these lessons are still relevant during the present time, like the importance of detailing in "robustness", the design of "integral" structures or the due consideration of construction methods. Finally, the investigation has revived, once again, the figure of D. José Eugenio Ribera, whose role in the introduction of reinforced concrete in Spain was crucial. With the construction of the 3th Reservoir he took too much risk and caused a disaster that accelerated the transition to a new era in structural concrete based on greater scientific knowledge and the first codes. In this new period he would also play a major role.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

El papel esencial de los rellenos en el comportamiento y la estabilidad de las construcciones de fábrica ha sido sorprendentemente ignorado en la bibliografía técnica, contribuyendo este trabajo a cubrir esta laguna del conocimiento. Se presenta en primer lugar la configuración morfológica de los rellenos del trasdós de bóvedas en la Península Ibérica en tres periodos histórico-técnicos: la construcción romana, la románica y la gótica. La clasificación se ha realizado en base a inspecciones visuales de diferentes edificios. En sendos anexos se presentan análisis comparados de la base de datos que se ha reunido y las fichas de las construcciones consideradas. En segundo lugar se ha caracterizado el papel estructural de los rellenos, identificándose las características intrínsecas que se estiman más significativas de dichos rellenos en relación tanto con su propia configuración como con su función estructural. Muy en particular se proponen unas leyes de empujes coherentes con la naturaleza y con las condiciones de contorno de los rellenos y las bóvedas. En esta tesis se ha desarrollado una sencilla, potente y suficiente herramienta de análisis que considera las principales variables que intervienen en el comportamiento de una estructura de fábrica, incluyendo muy particularmente los rellenos. Para ello se ha planteado una herramienta basada en el análisis límite que incluye la comprobación tensional de los diferentes esfuerzos, normales o tangenciales, así como la interfaz entre bóvedas y rellenos, dotándose a los técnicos de una herramienta que permite entender estas estructuras, de complejo funcionamiento. La herramienta propuesta incluye consideraciones energéticas para encontrar la solución más cercana al funcionamiento real. La herramienta se ha calibrado con ejemplos analizados por otros autores con diferentes procedimientos, poniéndose de manifiesto su suficiente precisión y eficacia, especialmente si se tiene en cuenta que requiere sólo de unos datos mínimos. La calibración se ha extendido al ensayo en modelo reducido de este tipo de estructuras en el Laboratorio de Estructuras de la Escuela de Ingenieros de Caminos, Canales y Puertos de Madrid. Fruto de esa calibración, se ha realizado un amplio estudio paramétrico que permite cuantificar la influencia que tienen en el comportamiento estructural variables como el apuntamiento de las bóvedas (relación luz/flecha), su esbeltez (relación luz/canto en clave), la altura de los rellenos rígidos, la altura de los rellenos granulares, etc. Ese estudio ha permitido identificar los puntos críticos, las ratios características que condicionan el comportamiento y, en fin, los aspectos clave del análisis estructural de estas construcciones desde el punto de vista de la interrelación, hasta ahora desconocida, de estructura y relleno, que también es estructura. Ello permitirá orientar de mejor manera las inspecciones de estas estructuras y sus análisis estructurales. Finalmente, la tesis concluye con el desarrollo de tres ejemplos, correspondientes cada uno de ellos a los periodos históricos referidos, en los que se pone de manifiesto el papel crucial de los rellenos en la estabilidad no sólo de las bóvedas sino del resto de elementos estructurales que componen un edificio (pilares, muros, botareles, etc.). Al final se presentan las conclusiones del trabajo y se enumeran las muchas líneas de trabajo que quedan abiertas tras esta tesis. It is surprising that the essential role of the backfill at the extrados of masonry vaults and domes has been ignored or misunderstood in the technical literature. The main purpose of this work is to contribute to overcome such a lacuna. Firstly, the morphological configuration of backfill that can be found in the Iberian Peninsula in Roman, Romanesque and Gothic buildings is also presented. Two annexes are devoted to show the collected database and the result of its analysis. Then, the structural role of backfill is characterised, as well as the intrinsic and most significant properties related both to its configuration and structural function. Thus, specific thrust values are proposed to analyse such structures, taking into account the nature and boundary conditions of walls and vaults. The simple, powerful and sufficient tool of analysis that has been developed is also presented, including the main variables involved, especially the backfill. The limit analysis method, followed by a stress verification, including the extrados of vaults and backfill interface, and an enhanced algorithm based on energetic considerations, are used to provide technicians a tool to understand this type of structures efficiently, in a balanced situation between the rather scarce amount of information and sufficient accuracy and liability. The tool was calibrated by comparing the experimental and theoretical results provided by different authors regarding several examples, as well as our own experimental campaign carried out at the Civil Engineering School of Madrid. A parametric study is also developed, providing original information about the structural importance of several parameters, as the span-to-depth or span-to-rise ratios, relative height of backfill, etc. As a result of this analysis, critical points and tendencies of structural behaviour were detected, helping technicians to inspect and analyse these constructions, also revealing some particularities related to their construction. Furthermore, a set of three examples corresponding to the three structural typologies analysed (Roman, Romanesque and Gothic) is studied. The crucial importance of backfill is then highlighted, not only for the stability of vaults or domes, but also for the equilibrium of walls, pillars and buttresses. Finally, the conclusions of the study and the future research fields are also presented.