995 resultados para Stray current corrosion


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The abrasion damage on retrieved CoCrMo based hip joints is reported to be influenced by the entrainment of micron and sub-micron sized debris/hard particles. This paper represents the first attempt to look into the effects of relatively soft abrasives with micron and sub-micron dimensions on the abrasion mechanisms and the abrasion-corrosion performance of the cast CoCrMo in simulated hip joint environments. A modified micro-abrasion tester incorporating a liquid tank and a three-electrode electrochemical cell was used. Al O (300 nm and 1 μm) and sub-micron sized BaSO abrasives were chosen as being comparable in the size and hardness to the wear particles found in vivo. Results show that the specific wear rates of cast CoCrMo are dependent on the abrasive particle size, hardness and volume concentration. Larger particle size, higher hardness and greater abrasive volume fractions gave greater wear rates. The wear-induced corrosion current generally increases with increasing wear rates, and the presence of proteins seems to suppress the wear-induced corrosion current especially when abrasive volume fractions were high. This study shows that the nature of abrasives and the test solutions are both important in determining the wear mechanisms and the abrasion-corrosion response of cast CoCrMo. These findings provide new and important insights into the in vivo wear mechanisms of CoCrMo. © 2009 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Este trabalho teve como objetivos a produção, caracterização e aplicação de microelétrodos (MEs) de diamante como sensores amperométricos e potenciométricos em sistemas de corrosão nos quais a agressividade do meio e a presença de produtos de corrosão, constituem obstáculos que podem diminuir o desempenho, ou inviabilizar a utilização, de outros tipos de sensores. Os microeléctrodos são baseados em filmes finos de diamante dopado com boro (BDD – Boron Doped Diamond) depositados sobre fios de tungsténio afiados, através do método de deposição química a partir da fase vapor, assistida por filamento quente (HFCVD – Hot Filament Chemical Vapor Deposition). A otimização das diversas etapas de fabricação dos MEs deu origem ao desenvolvimento de um novo sistema de afiamento eletroquímico para obtenção destes fios e a várias opções para a obtenção dos filmes de diamante condutor e seu isolamento com resinas para exposição apenas da ponta cilíndrica. A qualidade cristalina dos filmes de diamante foi avaliada por espectroscopia de Raman. Esta informação foi complementada com uma caracterização microestrutural dos filmes de diamante por microscopia eletrónica de varrimento (SEM), em que se fez a identificação da tipologia dos cristais como pertencendo às gamas de diamante nanocristalino ou microcristalino. Os filmes de BDD foram utilizados na sua forma não modificada, com terminações em hidrogénio e também com modificação da superfície através de tratamentos de plasma RF de CF4 e O2 indutores de terminações C-F no primeiro caso e de grupos C=O, C-O-C e C-OH no segundo, tal como determinado por XPS. A caracterização eletroquímica dos MEs não modificados revelou uma resposta voltamétrica com elevada razão sinal/ruído e baixa corrente capacitiva, numa gama de polarização quasi-ideal com extensão de 3 V a 4 V, dependente dos parâmetros de crescimento e pós-tratamentos de superfície. Estudou-se a reversibilidade de algumas reações heterogéneas com os pares redox Fe(CN)6 3-/4- e FcOH0/+ e verificou-se que a constante cinética, k0, é mais elevada em elétrodos com terminações em hidrogénio, nos quais não se procedeu a qualquer modificação da superfície. Estes MEs não modificados foram também testados na deteção de Zn2+ onde se observou, por voltametria cíclica, que a detecção da redução deste ião é linear numa escala log-log na gama de 10-5-10-2 M em 5 mM NaCl. Realizaram-se também estudos em sistemas de corrosão modelares, em que os microeléctrodos foram usados como sensores amperométricos para mapear a distribuição de oxigénio e Zn2+ sobre um par galvânico Zn-Fe, com recurso a um sistema SVET (Scanning Vibrating Electrode Technique). Foi possível detetar, com resolução lateral de 100 μm, um decréscimo da concentração de O2 junto a ambos os metais e produção de catiões de zinco no ânodo. Contudo verificou-se uma significativa deposição de zinco metálico na superfície dos ME utilizados. Os MEs com superfície modificada por plasma de CF4 foram testados como sensores de oxigénio dissolvido. A calibração dos microeléctrodos foi efetuada simultaneamente por voltametria cíclica e medição óptica através de um sensor de oxigénio comercial. Determinou-se uma sensibilidade de ~0.1422 nA/μM, com um limite de deteção de 0.63 μM. Os MEs modificados com CF4 foram também testados como sensores amperométricos com os quais se observou sensibilidade ao oxigénio dissolvido em solução, tendo sido igualmente utilizados durante a corrosão galvânica de pares Zn-Fe. Em alguns casos foi conseguida sensibilidade ao ião Zn2+ sem que o efeito da contaminação superficial com zinco metálico se fizesse sentir. Os microeléctrodos tratados em plasma de CF4 permitem uma boa deteção da distribuição de oxigénio, exibindo uma resposta mais rápida que os não tratados além de maior estabilidade de medição e durabilidade. Nos MEs em que a superfície foi modificada com plasma de O2 foi possível detetar, por cronopotenciometria a corrente nula, uma sensibilidade ao pH de ~51 mV/pH numa gama de pH 2 a pH 12. Este comportamento foi associado à contribuição determinante de grupos C-O e C=O, observados por XPS com uma razão O/C de 0,16. Estes MEs foram igualmente testados durante a corrosão galvânica do par Zn-Fe onde foi possível mapear a distribuição de pH associada ao desenvolvimento de regiões alcalinas causadas pela redução do oxigénio, acima da região catódica, e de regiões ácidas decorrentes da dissolução anódica do ânodo de zinco. Com o par galvânico imerso em 50 mM NaCl registou-se uma variação de pH aproximadamente entre 4,8 acima do ânodo de zinco a 9,3 sobre o cátodo de ferro. A utilização pioneira destes MEs como sensores de pH é uma alternativa promissora aos elétrodos baseados em membranas seletivas.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The biocompatibility of commercially pure (cp) titanium stems from its chemical stability within an organism, due to a fine film of impermeable titanium oxide covering the metal surface, which guarantees its resistance to corrosion. Despite its biocompatible characteristic, this material does not promote the formation of a hydroxyapatite layer, therefore, many research groups have sought to alter the material`s surface, introducing modifications that might influence corrosion resistance. The electrochemical behavior of cp Ti, with hydroxyapatite coating and without hydroxyapatite coating, commonly used in implant materials, was investigated using an artificial saliva solution at 25 degrees C and pH=7.4. In the conditions of the study it was observed that the hydroxyapatite layer influences the properties of corrosion resistance. This study of the behavior of cp Ti with and without hydroxyapatite coating, in naturally aerated artificial saliva solution at 25 degrees C, was based on open circuit potential measurements and potentiodynamic polarization curves. At approximately 1x10(-6) A/cm(2) the potential for cp Ti with and without hydroxyapatite coating begins to increase at a faster rate, but at -74mV (SCE) for coated cp Ti and at 180mV (SCE) for uncoated cp Ti the increase in potential begins to slow. This behavior, characterized by a partial stabilization of current density, indicates that in those potential ranges a protective passive film is formed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Existing corrosion protection technologies for aluminium alloys utilising chromates are environmentally damaging and extremely toxic. This paper presents a preliminary investigation into rare earth diphenyl phosphates as new environmentally benign corrosion inhibitors. Full immersion weight loss experiments, cyclic potentiodynamic polarisation measurements and Raman spectroscopy were used in this study. Results show cerium diphenyl phosphate (Ce(dpp)3) acts as a cathodic inhibitor, decreasing cathodic current density and Ecorr by passivating cathodic intermetallic particles on the alloy surface. Mischmetal diphenyl phosphate (Mm(dpp)3) acts a mixed inhibitor, shifting Ecorr to more noble values, decreasing cathodic current density, increasing the breakdown potential and suppressing pitting.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The use of materials with otherwise desirable mechanical properties is often problematic in practice as a result of corrosion. Susceptibility may arise for a number of reasons, including an electrochemically heterogeneous surface or destabilisation of a passive film. These shortcomings have historically been overcome through the use of various coatings or claddings. However, a more robust surface layer with enhanced corrosion resistance could possibly be produced via local surface alloying using a fluidised bed. A fluidised bed treatment allows a surface to be alloyed, producing a distinct surface layer up to tens of microns thick. Surface alloying additions can be selected on the basis of whether they are known or suspected to enhance the corrosion resistance of a particular material, whilst at a minimum, surface alloying likely provides a more electrochemically homogeneous surface. Electrochemical evaluations using potentiodynamic polarisations in NaCl electrolytes have shown chromised plain carbon and stainless steel surfaces have decreased rates of corrosion, decreased passive current densities, and ennobled pitting potentials relative to untreated specimens.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

At present water treatment and distribution is of high priority to ensure that communities have access to safe and affordable drinking water. Current information states that in the United States a total annual cost of $36 billion (US) is spent replacing aging infrastructure, lost water from unaccounted-for leaks, corrosion inhibitors, internal mortar linings, external coatings, and cathodic protection as a result of corrosion. In order to reduce the cost incurred as a result of corrosion in the water distribution industry, it is essential that better corrosion management and preventative strategies are implemented. However through investigation of research previously undertaken by others, it was found that there was a lack of study of corrosion within distribution systems in the tropics taking into account the related seasonal temperature variations. To assist in the development of management strategies to improve the outcomes of drinking water distribution systems, the authors propose to implement a pilot study involving the installation of a corrosion reactor based on standard corrosion assessment technologies in a water distribution system located in the tropics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose - The objective of this work was to develop practical experimental techniques for monitoring corrosion in "difficult-to-test" conditions such as corrosion under insulation (CUI).

Design/methodology/approach - An electrochemically integrated multi-electrode array namely the wire beam electrode (WBE) method has been used in combination with noise signature analysis for the first time to monitor the penetration of corrosive species under simulated corrosion-under-insulation conditions. Corrosion of aluminium exposed under insulation materials such as rock wool, glass wool, cotton wool and tissue paper has been successfully monitored.

Findings - A typical potential noise signature of a major potential jump from AA1100 WBE was observed which corresponded to the corrosive species reaching the WBE surface in WBE current distribution map. A good correlation between the galvanic current maps and the corroded surface was also observed.

Originality/value - The preliminary results suggest that the proposed novel electrochemical method is capable of monitoring CUI.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The effect of rf-power in the range from 100 to 200 W on the electrochemical properties of TiN coatings deposited on 316L stainless steel was investigated by using various electrochemical techniques in a 3.5-wt\% NaCl solution. Surface analyses were also conducted to analyze the coating characteristics. X-ray diffraction (XRD) and atomic force microscopy (AFM) analyses confirmed that increasing the rf-power led to a preferred orientation of the TiN(200) microstructure and decreased the surface roughness. The potentiodynamic test results confirmed the passive behavior of all of the specimens with low passive current densities and demonstrated that the effective pitting resistance of the TiN coatings increased with increasing rf-power. The electrochemical impedance spectroscopy (EIS) tests showed that the TiN films deposited with high rf-power had excellent corrosion resistance during an immersion time of 720 h due to their high total resistance and low porosity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An electrochemically integrated multi-electrode array namely the wire beam electrode (WBE) and noise signatures analysis have been applied in novel combinations to study crevice corrosion behaviour in the presence of pits. Characteristic electrochemical noise signatures were found to correlate with characteristic changes in WBE current distribution maps, which indicate corrosion rates distributions, corrosion patterns and the degree of pitting and crevice corrosion. Specifically, two characteristic noise patterns were observed: (i) the characteristic noise pattern of quick potential changes towards more negative direction with no recovery (termed noise signature I) was found to correspond with the initiation and stabilization of the anode inside crevice; and (ii) the characteristic noise pattern of the cyclic potential oscillation at a constant frequency (termed noise signature II) was found to correspond with the stable anodic dissolution in the occluded cavity site in WBE current distribution maps. A new parameter namely the localization parameter (LP) has been proposed to describe the degree of localization. The LP for crevice corrosion was found to be low compared to that for pitting corrosion.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aqueous corrosion behavior of low-alloy steel with aluminum contents was examined in a 10 wt% H2SO4 (pH 0.13) solution using electrochemical techniques and surface analyses. The corrosion resistance of the new alloy steel was evaluated in terms of electrochemical parameters, such as passive current density, film, and charge transfer resistances. The results showed that a high Al content in the steel imparted better passivation behavior resulting in a lower corrosion rate. It related to the enrichment of iron carbonate and hydrocarbon by the dissolution of the carbide phase.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A novel electrochemically integrated multi-electrode array namely the wire beam electrode(WBE) in combination with noise signatures analysis has been designed to monitor pittingcorrosion of one of the best corrosion resistance ferrous alloys, stainless steel type 316L.From the direct correlation of electrochemical potential noise signatures and galvanic currentdistribution maps during pitting corrosion processes, two characteristic noise patterns wereobserved prior to stable pit formation: (i) the characteristic ‘peak’ of rapid potential transient,towards less negative direction, followed by recovery (termed noise signature I) was found tocorrelate with the disappearance of unstable anode; (ii) the characteristic noise pattern ofquick potential changes towards less negative direction followed by no recovery (termed noisesignature II) was found to correspond with the massive disappearance of minor anodes leadingto formation of highly localized major anodes in the galvanic current distribution maps.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An auto-switch device has been designed, constructed, and tested for multisensor corrosion measurements. The auto-switch is able to connect/disconnect the selected wire beam electrode and/or electrode pairs under computer control. A computer controlled analog switch-array consisting of 100 inputs has been used as an essential part of the switch bank. The switch-bank is an essential component of a corrosion-monitoring instrument that is expected to find wide application in industry. The performance of the switch-bank is discussed and its effect on the signals is illustrated.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Parameters extracted from the wire beam electrode (WBE) galvanic current maps have been used in conjunction with electrochemical noise patterns to directly quantify the degree of localised corrosion inhibition provided by inhibitors and to understand the mechanism of localised corrosion inhibition. The behaviour of two traditional localised corrosion inhibitors has been assessed by their effects on the maximum anodic current density (imax), total anodic current density (itot), the number of anodic sites (Na) and the localised corrosion intensity index (LCII). Typical experiments are presented to illustrate the application of these parameters in providing useful information on the efficiency and mechanism of localised corrosion inhibition.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The corrosion behaviour of nanocrystalline and microcrystalline Fe20Cr alloys, prepared by high energy ball milling followed by compaction and sintering, was studied in 0.05M H2SO4 and 0.05M H2SO4 + 0.5M NaCl by potentiodynamic polarization. The nanocrystalline alloy exhibited improved passivating ability and pitting resistance as described by passivation potential, critical current density, passive current density and breakdown potential. XPS and SIMS analysis revealed greater Cr content in the passive film formed on the nanocrystalline form of the alloy. The enhanced passivating ability of the nanocrystalline alloy was attributed to the formation of the passive film with higher Cr content.