949 resultados para Step-up ratio


Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper presents dynamic hysteresis band height control to reduce the overshoot and undershoot issue on output voltage caused by load change. The converters in this study are Boost and Positive Buck-Boost (PBB) converters. PBB has been controlled to work in a step up conversion and avoid overshoot when load is changed. Simulation and experimental results have been presented to verify the proposed method.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In photovoltaic, fuel cells and storage batteries, the low output DC voltage should be boosted. Therefore, a step-up converter is necessary to boost the low DC voltage for the DC link voltage of the inverter. The main contribution of this chapter is to electrical energy conversion in renewable energy systems based on multilevel inverters. Different configuration of renewable energy systems based on power converters will be discussed in detail. Finally, a new single inductor Multi-Output Boost (MOB) converter is proposed, which is compatible with the diode-clamped configuration. Steady state and dynamic analyses have been carried out in order to show the validity of the proposed topology. Then the joint circuit of the proposed DC-DC converter with a three-level diode-clamped converter is presented in order to have a series regulated voltage at the DC link voltage of the diode-clamped inverter. MOB converter can boost the low input DC voltage of the renewable energy sources and at the same time adjust the voltage across each capacitor to the desired voltage levels, thereby solving the main problem associated with capacitor voltage imbalance in this type of multilevel converter.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper presents a new multi-output DC/DC converter topology that has step-up and step-down conversion capabilities. In this topology, several output voltages can be generated which can be used in different applications such as multilevel converters with diode-clamped topology or power supplies with several voltage levels. Steady state and dynamic equations of the proposed multi-output converter have been developed, that can be used for steady state and transient analysis. Two control techniques have been proposed for this topology based on constant and dynamic hysteresis band height control to address different applications. Simulations have been performed for different operating modes and load conditions to verify the proposed topology and its control technique. Additionally, a laboratory prototype is designed and implemented to verify the simulation results.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The Proposal is a well-executed romantic comedy that easily meets its low ambitions. Director Anne Fletcher (Step Up, 27 Dresses) and newcomer writer Peter Chiarelli team up to deliver a lighthearted comedy termpered with heartwarming family values. The cute and lovable cast, headed by Sandra Bullock and Ryan Reynolds, enriches this simple tale...

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Leadership research demonstrates that there are serious shortcomings in the quality and competence of leaders in our organizations. The recent global financial crisis has also reminded us that, if our society and economies are to move forward sustainability, we must have the right kind of leaders and the right kind of leadership throughout our organizations. "The Leader in You: Developing Your Leadership Potential" has been framed to be useful to all individuals who are currently in leadership roles, from chief executives to frontline managers, and for those who wish to step up to a leadership role. Organizations can also utilize this book to assist their leaders to increase their leadership potential or to complement leadership development programs. If you want to search for and develop leadership qualities in yourself, then this book is for you. If you want to set a higher standard in your organization and you think leadership is a serious matter in the lives of other people, then this book is for you. In the process of self-reflection, "The Leader in You: Developing Your Leadership Potential" will enable you to develop an individual leadership profile and an individual skills profile, culminating in the development of a plan for leadership improvement. This book aims to couple these outcomes with exposure to some practical skills that leaders need to lead in every day environments. The first four chapters allow the reader to develop an understanding of the concepts that underpin leadership performance, and to undertake exercises to develop a comprehensive understanding of their values, behaviors and personality. That is, to understand who they are and why they behave the way they do. An individual leadership profile is developed at the end of these chapters. Then, the remaining chapters look at issues that leaders will face in contemporary society, and at the skills required to address them in everyday environments. An individual skills profile is developed at the end of these chapters culminating in the development of a plan for leadership improvement.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The LIS profession in Australia is a small world where connections are vital for career success and developing resilience. So what about those of us who feel like wallflowers at the party, always on the margins? It can be difficult for quieter souls to step up, get involved and build relationships. A major hurdle for many people, both introverts and extroverts, is figuring out how to proclaim their awesomeness to the world but in a way that is unique to them. The aim of this session is to inspire and challenge students, new grads and anyone who has a fear of networking to take risks and explore a different more social side of themselves without changing their personalities. This is a deeply personal topic with plenty of fear and self-image issues at stake. As well, most of us have had very few opportunities to find role models or a chance to practice in a comfortable environment. Therefore the authors will present strategies for success based on their personal experiences. We will demonstrate the actual benefits we have attained through our networking and volunteer activities. We hope that attendees will come away with some realistic strategies and goals to create lasting relationships with present and future colleagues such as we have enjoyed. Our networking tips may not transform you into the belle of the ball but you will have more confidence to get out on the dance floor and dance to your own beat.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective. To investigate the reliability and validity of five squat-based loading tests that are clinically appropriate for jumper's knee. The loading tests were step up, double leg squat, double leg squat on a 25-degree decline (decline squat), single leg decline squat, and decline hop. Design. Cross-sectional controlled cohort. Subjects without knee pain comprised controls, those with extensor tendon pain comprised the jumper's knee group. Setting. Institutional athlete study group in Australia Participants. Fifty-six elite adolescent basketball players participated in this study, thirteen comprised the jumper's knee group, fifteen athletes formed a control group. Intervention. Each subject performed each loading test for baseline and reliability data on the first testing day. Subjects then performed three days of intensive (6 h daily) basketball training, after which each loading test was reexamined. Main outcome measures. Eleven point interval scale for pain. Results. The tests that best detected a change in pain due to intensive workload were the single leg decline squat and single leg decline hop. This study found that decline tests have better discriminative ability than the standard squat to detect change in jumper's knee pain due to intensive training. The typical error for these tests ranged from 0.3 to 0.5, however, caution should be exercised in the interpretation of these reliability figures due to relatively low scores. Conclusions. The single leg decline squat is recommended in the physical assessment of adolescent jumper's knee. The decline squat was selected as the best clinical test over the decline hop because it was easier to standardise performance.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

New residential scale photovoltaic (PV) arrays are commonly connected to the grid by a single DC-AC inverter connected to a series string of PV modules, or many small DC-AC inverters which connect one or two modules directly to the AC grid. This paper shows that a "converter-per-module" approach offers many advantages including individual module maximum power point tracking, which gives great flexibility in module layout, replacement, and insensitivity to shading; better protection of PV sources, and redundancy in the case of source or converter failure; easier and safer installation and maintenance; and better data gathering. Simple nonisolated per-module DC-DC converters can be series connected to create a high voltage string connected to a simplified DC-AC inverter. These advantages are available without the cost or efficiency penalties of individual DC-AC grid connected inverters. Buck, boost, buck-boost and Cuk converters are possible cascadable converters. The boost converter is best if a significant step up is required, such as with a short string of 12 PV modules. A string of buck converters requires many more modules, but can always deliver any combination of module power. The buck converter is the most efficient topology for a given cost. While flexible in voltage ranges, buck-boost and Cuk converters are always at an efficiency or alternatively cost disadvantage

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A group of passionate and naïve young people leave their known worlds behind to spend 100 days in the jungles of Borneo. Their mission is to confront one of the great global challenges of our time, saving rainforests and giving hope to endangered orangutans. Their task is enormous and the odds are against them. Jojo, an orphaned baby orangutan, is entrusted in their care and they must find a way to return her to her forest home. To do this, they need to build an orangutan rehabilitation centre and find ways to help the local communities protect their forest. Under the guidance of their mentor Dr Willie Smits, they introduce an innovative satellite monitoring system called Earthwatchers and enlist the help of school students around the world. The system is put to the test when the bulldozers move in and threaten the future of a nearby community living in a traditional longhouse. This is a story about what it takes it be an eco-warrior, an individual willing to step up and take action to avert a global catastrophe taking place before our eyes. The eco-warriors represent a new generation, ready to face what is happening on our planet and willing to do something, no matter how small, to build a more humane and balanced world. For them, every individual matters, every action counts. - Written by Cathy Henkel

Relevância:

80.00% 80.00%

Publicador:

Resumo:

An offshore wind turbine usually has the grid step-up transformer integrated in the nacelle. This increases mechanical loading of the tower. In that context, a transformer-less, high voltage, highly-reliable and compact converter system for nacelle installation would be an attractive solution for large offshore wind turbines. This paper, therefore, presents a transformer-less grid integration topology for PMSG based large wind turbine generator systems using modular matrix converters. Each matrix converter module is fed from three generator coils of the PMSG which are phase shifted by 120°. Outputs of matrix converter modules are connected in series to increase the output voltage and thus eliminate the need of a coupling step-up transformer. Moreover, dc-link capacitors found in conventional back-to-back converter topologies are eliminated in the proposed system. Proper multilevel output voltage generation and power sharing between converter modules are achieved through an advanced switching strategy. Simulation results are presented to validate the proposed modular matrix converter system, modulation method and control techniques.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Vertical line extensions, both step-up and step-down, are common occurrence in consumer products. For example, Timex recently launched its luxury high-end Valentino line. On the other hand, many companies use downscale extensions to increase the overall sales volume. For instance, a number of luxury watch brands recently introduced watch collections with lower price points, like TAG Heur’s affordable watch the Aquaracer Calibre 5. Previous literature on vertical extensions has investigated how number of products in the line (Dacin and Smith 1994), the direction of the extension, brand concept (Kim, Lavack, and Smith 2001), and perceived risk (Lei, de Ruyter, and Wetzels 2008) affect extensions’ evaluation. Common to this literature is the use of models based on adaptation-level theory, which states that all relevant price information is integrated into a single prototype value and used in consumer judgments of price (Helson 1947; Mazumdar, Raj, and Sinha 2005). In the current research we argue that, while adaptation-level theory can be viewed as a useful simplification to understanding consumers’ evaluations, it misses out important contextual influences caused by a brand’s price range. Drawing on research on range-frequency theory (Mellers and Cooke 1994; Parducci 1965) we investigate the effects of price point distance and parent brand’s price range on evaluations of vertical extensions. Our reasoning leads to two important predictions that we test in a series of three experiments...

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Road crashes and injuries have become a growing issue worldwide. In 2011, more than 75,000 people died in road crashes in the ten member countries of the Association of South East Asian Nations (ASEAN) and many times this number sustained long term injuries. In 2014, the Asian Development Bank (ADB), funded by the Japan Fund for Poverty Reduction, commenced a package of actions to improve road safety in ASEAN. In 2015, as part of the technical assistance for this project, a Road Safety Advisor was appointed for Cambodia for four months. The assignment produced several primary outputs, which included the organization of national training on traffic law enforcement and road safety management, the conduct of a training needs survey and cost analysis study, and the development of a proposal for strengthening speed management. It is important to note that unlike other ADB technical assistance projects, this assignment adopted a capacity building approach, which promoted and encouraged the local road safety team in the government to step up and take action. The research capacity building approach adopted in this project highlighted the feasibility of increasing participation from existing stakeholders, especially the government in identifying existing human resources, building the capacity of relevant government officials and supporting them to take the ownership of the project. It is hoped that similar outcomes will occur in the other ASEAN countries.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this paper a modified Heffron-Phillip's (K-constant) model is derived for the design of power system stabilizers. A knowledge of external system parameters, such as equivalent infinite bus voltage and external impedances or their equivalent estimated values is required for designing a conventional power system stabilizer. In the proposed method, information available at the secondary bus of the step-up transformer is used to set up a modified Heffron-Phillip's (ModHP) model. The PSS design based on this model utilizes signals available within the generating station. The efficacy of the proposed design technique and the performance of the stabilizer has been evaluated over a range of operating and system conditions. The simulation results have shown that the performance of the proposed stabilizer is comparable to that could be obtained by conventional design but without the need for the estimation and computation of external system parameters. The proposed design is thus well suited for practical applications to power system stabilization, including possibly the multi-machine applications where accurate system information is not readily available.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In Finland, suckler cow production is carried out in circumstances characterized by a long winter period and a short grazing period. The traditional winter housing system for suckler cows has been insulated or uninsulated buildings, but there is a demand for developing less expensive housing systems. In addition, more information is needed on new winter feeding strategies, carried out in inexpensive winter facilities with conventional (hay, grass silage, straw) or alternative (treated straw, industrial by-product, whole-crop silage) feeds. The new feeding techniques should not have any detrimental effects on animal welfare in order to be acceptable to both farmers and consumers. Furthermore, no official feeding recommendations for suckler cows are available in Finland and, thus, recommendations for dairy cows have been used. However, this may lead to over- or underfeeding of suckler cows and, finally, to decreased economic output. In Experiment I, second-calf beef-dairy suckler cows were used to compare the effects of diets based on hay (H) or urea-treated straw (US) at two feeding levels (Moderate; M vs. Low; L) on the performance of cows and calves. Live weight (LW) gain during the indoor feeding was lower for cows on level L than on level M. Cows on diet US lost more LW indoors than those on diet H. The cows replenished the LW losses on good pasture. Calf LW gain and cow milk production were unaffected by the treatments. Conception rate was unaffected by the treatments but was only 69%. Urea-treated straw proved to be a suitable winter feed for spring-calving suckler cows. Experiment II studied the effects of feeding accuracy on the performance of first- and second-calf beef-dairy cows and calves. In II-1, the day-to-day variation in the roughage offered ranged up to ± 40%. In II-2, the same variation was used in two-week periods. Variation of the roughages offered had minor effects on cow performance. Reproduction was unaffected by the feeding accuracy. Accurate feeding is not necessary for young beef-dairy crosses, if the total amount of energy offered over a period of a few weeks fulfills the energy requirements. Effects of feeding strategies with alternative feeds on the performance of mature beef-dairy and beef cows and calves were evaluated in Experiment III. Two studies consisted of two feeding strategies (Step-up vs. Flat-rate) and two diets (Control vs. Alternative). There were no differences between treatments in the cow LW, body condition score (BCS), calf pre-weaning LW gain and cow reproduction. A flat-rate strategy can be practised in the nutrition of mature suckler cows. Oat hull based flour-mill by product can partly replace grass silage and straw in the winter diet. Whole-crop barley silage can be offered as a sole feed to suckler cows. Experiment IV evaluated during the winter feeding period the effects of replacing grass silage with whole-crop barley or oat silage on mature beef cow and calf performance. Both whole-crop silages were suitable winter feeds for suckler cows in cold outdoor winter conditions. Experiment V aimed at assessing the effects of daily feeding vs. feeding every third day on the performance of mature beef cows and calves. No differences between the treatments were observed in cow LW, BCS, milk production and calf LW. The serum concentrations of urea and long-chain fatty acids were increased on the third day after feeding in the cows fed every third day. Despite of that the feeding every third day is an acceptable feeding strategy for mature suckler cows. Experiment VI studied the effects of feeding levels and long-term cold climatic conditions on mature beef cows and calves. The cows were overwintered in outdoor facilities or in an uninsulated indoor facility. Whole-crop barley silage was offered either ad libitum or restricted. All the facilities offered adequate shelter for the cows. The restricted offering of whole-crop barley silage provided enough energy for the cows. The Finnish energy recommendations for dairy cows were too high for mature beef breed suckler cows in good body condition at housing, even in cold conditions. Therefore, there is need to determine feeding recommendations for suckler cows in Finland. The results showed that the required amount of energy can be offered to the cows using conventional or alternative feeds provided at a lower feeding level, with an inaccurate feeding, flat-rate feeding or feeding every third day strategy. The cows must have an opportunity to replenish the LW and BCS losses at pasture before the next winter. Production in cold conditions can be practised in inexpensive facilities when shelter against rain and wind, a dry resting place, adequate amounts of feed suitable for cold conditions and water are provided for the animals as was done in the present study.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper proposes a method of designing fixed parameter decentralized power system stabilizers (PSS) for interconnected multi-machine power systems. Conventional design technique using a single machine infinite bus approximation involves the frequency response estimation called the GEP(s) between the AVR input and the resultant electrical torque. This requires the knowledge of equivalent external reactance and infinite bus voltage or their estimated values at each machine. Other design techniques using P-Vr characteristics or residues are based on complete system information. In the proposed method, information available at the high voltage bus of the step-up transformer is used to set up a modified Heffron-Phillip's model. With this model it is possible to decide the structure of the PSS compensator and tune its parameters at each machine in the multi-machine environment, using only those signals that are available at the generating station. The efficacy of the proposed design technique has been evaluated on three of the most widely used test systems. The simulation results have shown that the performance of the proposed stabilizer is comparable to that which could be obtained by conventional design but without the need for the estimation and computation of external system parameters.