990 resultados para Stents and prostheses
Resumo:
Central venous catheters (CVCs) are being utilized with increasing frequency in intensive care and general medical wards. In spite of the extensive experience gained in their application, CVCs are related to the long-term risks of catheter sheath formation, infection, and thrombosis (of the catheter or vessel itself) during catheterization. Such CVC-related-complications are associated with increased morbidity, mortality, duration of hospitalization, and medical care cost [1]. The present study incorporates a novel group of Factor XIIIa (FXIIIa, plasma transglutaminase) inhibitors into a lubricious silicone elastomer in order to generate an optimized drug delivery system whereby a secondary sustained drug release profile occurs following an initial burst release for catheters and other medical devices. We propose that the incorporation of FXIIIa inhibitors into catheters, stents, and other medical implant devices would reduce the incidence of catheter sheath formation, thrombotic occlusion, and associated staphylococcal infection. This technique could be used as a local delivery system for extended release with an immediate onset of action for other poorly aqueous soluble compounds. © 2012 Elsevier B.V. All rights reserved.
Resumo:
Depuis ces dernières décennies, le domaine des biomatériaux a connu un essor considérable, évoluant de simples prothèses aux dispositifs les plus complexes pouvant détenir une bioactivité spécifique. Outre, le progrès en science des matériaux et une meilleure compréhension des systèmes biologiques a offert la possibilité de créer des matériaux synthétiques pouvant moduler et stimuler une réponse biologique déterminée, tout en améliorant considérablement la performance clinique des biomatériaux. En ce qui concerne les dispositifs cardiovasculaires, divers recouvrements ont été développés et étudiés dans le but de modifier les propriétés de surface et d’améliorer l’efficacité clinique des tuteurs. En effet, lorsqu’un dispositif médical est implanté dans le corps humain, son succès clinique est fortement influencé par les premières interactions que sa surface établit avec les tissus et les fluides biologiques environnants. Le recouvrement à la surface de biomatériaux par diverses molécules ayant des propriétés complémentaires constitue une approche intéressante pour atteindre différentes cibles biologiques et orienter la réponse de l’hôte. De ce fait, l’élucidation de l’interaction entre les différentes molécules composant les recouvrements est pertinente pour prédire la conservation de leurs propriétés biologiques spécifiques. Dans ce travail, des recouvrements pour des applications cardiovasculaires ont été créés, composés de deux molécules ayant des propriétés biologiques complémentaires : la fibronectine (FN) afin de promouvoir l’endothélialisation et la phosphorylcholine (PRC) pour favoriser l’hémocompatibilité. Des techniques d’adsorption et de greffage ont été appliquées pour créer différents recouvrements de ces deux biomolécules sur un polymère fluorocarboné déposé par traitement plasma sur un substrat en acier inoxydable. Dans un premier temps, des films de polytétrafluoroéthylène (PTFE) ont été utilisés en tant que surface modèle afin d’explorer l’interaction de la PRC et de la FN avec les surfaces fluorocarbonées ainsi qu’avec des cellules endothéliales et du sang. La stabilité des recouvrements de FN sur l’acier inoxydable a été étudiée par déformation, mais également par des essais statiques et dynamiques sous-flux. Les recouvrements ont été caractérisés par Spectroscopie Photoéléctronique par Rayons X, immunomarquage, angle de contact, Microscopie Électronique de Balayage, Microscopie de Force Atomique et Spectrométrie de Masse à Ionisation Secondaire à Temps de Vol (imagerie et profilage en profondeur). Des tests d’hémocompatibilité ont été effectués et l’interaction des cellules endothéliales avec les recouvrements a également été évaluée. La FN greffée a présenté des recouvrements plus denses et homogènes alors que la PRC quant à elle, a montré une meilleure homogénéité lorsqu’elle était adsorbée. La caractérisation de la surface des échantillons contenant FN/PRC a été corrélée aux propriétés biologiques et les recouvrements pour lesquels la FN a été greffée suivie de l’adsorption de la PRC ont présenté les meilleurs résultats pour des applications cardiovasculaires : la promotion de l’endothélialisation et des propriétés d’hémocompatibilité. Concernant les tests de stabilité, les recouvrements de FN greffée ont présenté une plus grande stabilité et densité que dans le cas de l’adsorption. En effet, la pertinence de présenter des investigations des essais sous-flux versus des essais statiques ainsi que la comparaison des différentes stratégies pour créer des recouvrements a été mis en évidence. D’autres expériences sont nécessaires pour étudier la stabilité des recouvrements de PRC et de mieux prédire son interaction avec des tissus in vivo.
Resumo:
Clinical feasibility of mandibular implant overdenture retainers submitted to immediate load Introduction: Millions of people around the world do not have access to the benefits of osseointegration. Treatments involving oral rehabilitation with overdentures have been widely used by specialists in the oral medicine field. This is an alternative therapy for retention and stability achievement in total prosthesis with conventional treatment, and two implants are enough to establish a satisfactory overdenture. Objective: The objectives of the study were to evaluate 16 patients of both sexes, with an average age of 47.4 +/- 4 years, using electromyographic analysis of masseter and temporal muscles and analyse the increase of incisive and molar maximal bite force with their existing complete dentures and following mandibular implant overdenture therapy to assess the benefits of this treatment. Materials and methods: For these tests, the Myosystem-BR1 electromyograph and the IDDK Kratos dynamometer were used. Statistical analysis was performed using the repeated measures test (SPSS 17.0). Results: A decrease in electromyographic activity during the rest, lateral and protrusion movements and increase of the maximal incisive and molar bite force after 15 months with a mandibular implant overdenture was observed. Conclusion: All the patients in this study reported a considerable improvement in the masticatory function and prostheses stability following treatment. It is possible to propose that the use of mandibular implants overdenture should become the selected treatment for totally edentulous patients to facilitate oral function and quality of life.
Resumo:
OBJECTIVE: To assess the feasibility and safety of coronary interventions performed through the radial artery. METHODS: We studied 103 patients with ages from 38 to 86 years (57±8.7), 90 (87%) males, and: radial pulse with a good amplitude, presence of ulnar pulse, a good collateral flow through the palmar arch assessed with the Allen's test. RESULTS: The vascular approach was obtained in 97 (94%) patients, 88 (91%) treated electively and 9 (9%) during acute myocardial infarction, for primary angioplasty; 56 (64%) unstable angina; 22 (25%) stable angina; 10 (11%) were asymptomatic, 6 referred for recanalization of chronic occlusion and 4 silent ischemia in the first week after acute myocardial infarction. We approached 107 arteries: anterior descending artery, 49 (46%); right coronary artery, 27 (25%); circumflex artery, 25 (23%); diagonal artery, 6 (6%); and 2 saphenous vein bypass grafts. We treated 129 lesions: 80 (62%) B2 type; 23 (18%) B1 type; 17 (13%) C type; and 9 (7%). A type. There were 70 stents , and 59 balloon angioplasties performed. Thirty-two (33%) patients used GP IIb/IIIa inhibitors. The mean duration of the elective procedure was 42.3±12.8 min. Success, correct stent deployment and residual lesion <20%, was reached in 100% of the lesions treated with stent implantation; arterial dilation with residual lesion <50% was obtained in 96% of the lesions treated with transluminal coronary angioplasty (TCA). Complications, were: 1 (1.0%) non-Q-wave acute myocardial infarction; 2 (2%) hematomas in the forearm; and 2 losses of radial pulse. CONCLUSION: Radial artery aproach is practical and safe for percutaneous coronary interventions there was a low incidence of complications.
Resumo:
Introduction: Renal transplantation is considered the treatment of choice for end-stage renal disease. However, the association of occlusive aorto-iliac disease and chronic renal failure is frequent and aorto-iliac reconstruction may be necessary prior to renal transplantation. This retrospective study reviews the results of this operative strategy.Material and Methods: Between January 2001 and June 2010, 309 patients underwent renal transplantation at our institution and 8 patients had prior aorto-iliac reconstruction using prosthetic material. There were 6 men and 2 women with a median age of 62 years (range 51-70). Five aorto-bifemoral and 2 aorto-bi-iliac bypasses were performed for stage II (n=5), stage IV (n=1) and aortic aneurysm (n=1). In one patient, iliac kissing stents and an ilio-femoral bypass were implanted. 4 cadaveric and 4 living donor renal transplantations were performed with an interval of 2 months to 10 years after revascularization.The results were analysed with respect of graft and patients survival. Differences between groups were tested by the log rank method.Results: No complications and no death occurred in the post-operative period. All bypasses remained patent during follow-up. The median time of post transplantation follow-up was 46 months for all patients and 27 months for patients with prior revascularization. In the revascularized group and control group, the graft and patient survival at 1 year were respectively 100%/96%, 100%/99% and at 5 years 86%/86%, 86%/94%, without significant differences between both groups.Discussion: Our results suggest that renal transplantation following prior aorto-iliac revascularisation with prosthetic material is safe and effective. Patients with end-stage renal disease and concomitant aorto-iliac disease should therefore be considered for renal transplantation. However, caution in the interpretation of the results is indicated due to the small sample size of our study.
Resumo:
In the last few years, some of the visionary concepts behind the virtual physiological human began to be demonstrated on various clinical domains, showing great promise for improving healthcare management. In the current work, we provide an overview of image- and biomechanics-based techniques that, when put together, provide a patient-specific pipeline for the management of intracranial aneurysms. The derivation and subsequent integration of morphological, morphodynamic, haemodynamic and structural analyses allow us to extract patient-specific models and information from which diagnostic and prognostic descriptors can be obtained. Linking such new indices with relevant clinical events should bring new insights into the processes behind aneurysm genesis, growth and rupture. The development of techniques for modelling endovascular devices such as stents and coils allows the evaluation of alternative treatment scenarios before the intervention takes place and could also contribute to the understanding and improved design of more effective devices. A key element to facilitate the clinical take-up of all these developments is their comprehensive validation. Although a number of previously published results have shown the accuracy and robustness of individual components, further efforts should be directed to demonstrate the diagnostic and prognostic efficacy of these advanced tools through large-scale clinical trials.
Resumo:
BACKGROUND AND PURPOSE: Endovascular treatment of wide-neck bifurcation aneurysms often results in incomplete occlusion or aneurysm recurrence. The goals of this study were to compare results of coil embolization with or without the assistance of self-expandable stents and to examine how stents may influence neointima formation. MATERIALS AND METHODS: Wide-neck bifurcation aneurysms were constructed in 24 animals and, after 4-6 weeks, were randomly allocated to 1 of 5 groups: 1) coil embolization using the assistance of 1 braided stent (n = 5); 2) coil embolization using the assistance of 2 braided stents in a Y configuration (n = 5); 3) coil embolization without stent assistance (n = 6); 4) Y-stenting alone (n = 4); and 5) untreated controls (n = 4). Angiographic results were compared at baseline and at 12 weeks, by using an ordinal scale. Neointima formation at the neck at 12 weeks was compared among groups by using a semiquantitative grading scale. Bench studies were performed to assess stent porosities. RESULTS: Initial angiographic results were improved with single stent-assisted coiling compared with simple coiling (P = .013). Angiographic results at 12 weeks were improved with any stent assistance (P = .014). Neointimal closure of the aneurysm neck was similar with or without stent assistance (P = .908), with neointima covering coil loops but rarely stent struts. Y-stent placement alone had no therapeutic effect. Bench studies showed that porosities can be decreased with stent compaction, but a relatively stable porous transition zone was a limiting factor. CONCLUSIONS: Stent-assisted coiling may improve results of embolization by allowing more complete initial coiling, but these high-porosity stents did not provide a scaffold for more complete neointimal closure of aneurysms.
Resumo:
Interventional paediatric and congenital cardiology is expanding at a rapid pace. Validated techniques (such as aortic or pulmonary valve dilatations and occlusion of persistent ductus arteriosus and atrial septal defects) are improving thanks to the use of smaller introducers and sheaths, low-profile balloons and novel devices. Moreover, catheter-based interventions have emerged as an attractive alternative to surgery in other fields: pulmonary valve replacement, balloon and stent implantation for native and recurrent coarctation, and percutaneous closure of ventricular septal defects. On the other hand, percutaneous interventions in the paediatric population may be limited by patient size or the anatomy of the defect. Hybrid approaches involving both cardiac interventionists and surgeons are being developed to overcome these limitations. Based on a better understanding of cardiac development, fetal cardiac interventions are being attempted in order to alter the history of severe obstructive lesions. Finally, some interventional procedures still carry a low success rate-for example, pulmonary vein stenosis, even with the use of conventional stents. Biodegradable stents and devices are being developed and may find an application in this setting as well as in others. The purpose of this review is to highlight the advances in paediatric interventional cardiology since the beginning of the third millennium.
Resumo:
Les nouvelles technologies médicales contribuent aux dépenses en santé qui ne cessent de croître, alors que les budgets se trouvent limités. L’évaluation économique des technologies devraient permettre d’identifier quelles sont celles qui sont les plus rentables. Malgré cela, plusieurs technologies dont le rapport coût-efficacité reste plutôt limite ou défavorable sont utilisées en médecine moderne et remboursées par notre système public de santé. Ce mémoire se concentre sur deux technologies en santé cardiovasculaire dont le rapport coût-efficacité est plutôt limite mais qui sont fréquemment utilisées au Canada; les tuteurs médicamentés ou pharmaco-actifs et les défibrillateurs cardiaques implantables (DCI). Nous avons fait une évaluation contingente de ces technologies dans le but d’examiner si ce type d’évaluation économique complémentaire pouvait procurer un point de vue nouveau sur la valeur économique et sociétaire des ces technologies. Les résultats de ces deux évaluations indiquent que les patients accordent une grande importance aux bénéfices que procurent ces deux technologies. Nos résultats soutiennent les politiques de santé actuelles de rembourser de façon libérale ces deux technologies.
Resumo:
Pós-graduação em Ciência e Tecnologia de Materiais - FC
Resumo:
Pós-graduação em Odontologia - FOA
Resumo:
Several alloys present the shape memory effect and among them, the equiatomic NiTi alloy, nitinol, is the most important one. It is usually used in several engineering applications and also in biomedical devices, in the fabrication of orthodontic wire, stents and Judet staples. Although a considerable amount of these biomedical devices is utilized in Brazil and a fraction of it is already made here, all nitinol used is bought abroad. Thus, it is important to develop the necessary know-how to fabricate NiTi wire and sheet. It would mean less importation with job creation and wealth generation for the country. In this work nitinol was obtained powder metallurgy from elemental powders of Ti and Ni using uniaxial compression and uniaxial compression followed by isostatic compression. The final densities achieved were determined by the Archimedes method. The precipitation of intermetallic secondary phases was studied and the samples were characterized by metallographic analysis, optical microscopy and X-ray diffraction. Results indicated that 50 hours sintering route showed a low amount of intermetallics, and no trace of unreacted powder. XRD and metallography at room temperature indicated B19’ as the predominant phase, which corresponds to martensite. Although density results showed little dispersion, the most dense sample was compacted under uniaxial compression and presented 4.8 g/cm3, corresponding to 20.84% porosity. Density variation was considered normal to the measurement process and independent of the compaction mode
Resumo:
This paper describes a case of a rehabilitation involving Computer Aided Design/Computer Aided Manufacturing (CAD-CAM) system in implant supported and dental supported prostheses using zirconia as framework. The CAD-CAM technology has developed considerably over last few years, becoming a reality in dental practice. Among the widely used systems are the systems based on zirconia which demonstrate important physical and mechanical properties of high strength, adequate fracture toughness, biocompatibility and esthetics, and are indicated for unitary prosthetic restorations and posterior and anterior framework. All the modeling was performed by using CAD-CAM system and prostheses were cemented using resin cement best suited for each situation. The rehabilitation of the maxillary arch using zirconia framework demonstrated satisfactory esthetic and functional results after a 12-month control and revealed no biological and technical complications. This article shows the important of use technology CAD/CAM in the manufacture of dental prosthesis and implant-supported.
Resumo:
For some time, oral surgeons have tried several surgical procedures to improve the alveolar ridge for prosthetic appliance construction. The techniques used for this purpose are divided into four groups: submucosal vestibuloplasty; secondary epithelization; soft tissue grafting and transpositional flaps. Twenty patients who had problems to wear dentures due to unsatisfactory retention and stability were selected at the Oral and MaxilloFacial Surgery and Traumatology Clinic of Dental School of São José dos Campos. They were divided in two groups and operated by submucosal vestibuloplasty using stents and secondary epithelization vestibuloplasty by Clark's technique and were evaluated twelve months after operations in relationship of the sulcus depth. The results were obtained by clinical and radiological examination before and after surgery, and they are similar to those found in the literature reaching satisfactory functional judgement
Efeito dos parâmetros de retificação no acabamento superficial de cerâmicas aplicadas à biomateriais
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)