944 resultados para Stains and Staining
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Background: Hematology tests are useful to evaluate physiologic disturbances in fish and can provide important information for the diagnosis and prognosis of disease. Objectives: the primary purpose of this study was to define reference intervals for thrombocytes and leukocytes in healthy channel catfish (Ictalurus punctactus). In addition, the morphologic, cytochernical, and ultrastructural features of blood cells were assessed. Methods: Blood samples (0.5 mL were collected into EDTA from 40 clinically healthy catfish on a commercial fish farm in Jaboticabal, Brazil. Thrombocyte, total WBC, and differential WBC counts were determined and reference intervals were calculated as the 25-95th percentiles of data. Thrombocyte and leukocyte morphology was assessed in blood smears stained with May Griinwald-Giemsa-Wright and ultrastructurally by transmission electron microscopy. Cytochemical staining patterns were described using periodic acid-Schiff (PAS), peroxidase, nonspecific esterase, alkaline phosphatase, and toluidine blue. Results: Reference intervals were as follows: thrombocytes 58,802-99,569/mu L; total WBCs 27,460-41,523/mu L; lymphocytes 5380-11,581/mu L; monocytes 2949-7459/mu L; neutrophils 12,529-22,748/mu L, and basophils 736-2003/mu L. Neutrophils were positive for peroxidase and PAS; monocytes were positive for nonspecific esterase; and basophils were positive with toluidine blue. Conclusion: the morphologic and staining features of neutrophils and monocytes of channel catfish are similar to those of mammals, and the presence of basophils in this species was verified. These reference intervals and morphologic findings provide a foundation for future investigations on the functions and alterations of blood cells in channel catfish.
Resumo:
We have studied the possibility of associating fluorescence microscopy and hematoxylin-eosin staining for the identification of elastic fibers in elastin-rich tissues. Elastic fibers and elastic laminae were consistently identified by the proposed procedure, which revealed itself to be easy and useful for the determination of such structures and their distribution. The fluorescence properties of stained elastic fibers are due to eosin staining as revealed by fluorescence analysis of the dye in solution, with no or only minor contribution by the elastin autofluorescence. The main advantage of this technique resides in the possibility of studying the distribution of elastic fibers in file material without further sectioning and staining. The use of the confocal laser scanning microscope greatly improved the resolution and selectivity of imaging elastic fibers in different tissues. The determination of the three-dimensional distribution and structure of elastic fiber and laminae using the confocal laser scanning microscope was evaluated and also produced excellent results.
Resumo:
Background: Maxillary sinus floor augmentation procedures are currently the treatment of choice when the alveolar crest of the posterior maxilla is insufficient for dental implant anchorage. This procedure aims to obtain enough bone with biomaterial association with the autogenous bone graft to create volume and allow osteo conduction. The objective of this study was to histologically and histometrically evaluate the bone formed after maxillary sinus floor augmentation by grafting with a combination of autogenous bone, from the symphyseal area mixed with DFDBA or hydroxyapatite.Methods: Ten biopsies were taken from 10 patients 10 months after sinus floor augmentation using a combination of 50% autogenous bone plus 50% dernineralized freeze-dried bone allograft (DFDBA group) or 50% autogenous bone plus 50% hydroxyapatite (HA group). Routine histological processing and staining with hernatoxylin and eosin and Masson's trichrome were performed.Results: the histomorphometrical analysis indicated good regenerative results in both groups for the bone tissue mean in the grafted area (50.46 +/- 16.29% for the DFDBA group and 46.79 +/- 8.56% for the HA group). Histological evaluation revealed the presence of mature bone with compact and cancellous areas in both groups. The inflammatory infiltrate was on average nonsignificant and of mononuclear prevalence. Some biopsies showed blocks of the biomaterial in the medullary spaces close to the bone wall, with absence of osteogenic activity.Conclusions: the results indicated that both DFDBA and HA associated with an autogenous bone graft were biocompatible and promoted osteoconduction, acting as a matrix for bone formation. However, both materials were still present after 10 months.
Resumo:
This case report describes the sequential steps that were used to treat unesthetic, white, hard-texture enamel stains of unknown etiology. A tapered fine diamond bur was used to remove superficial enamel followed by the use of an enamel microabrasion compound Opalustre (Ultradent Products Inc). This technique removed the stains and was followed by polishing with a fluoride paste to restore the enamel to a smooth finish. The teeth were subsequently bleached with carbamide peroxide (Opalescence 10%, Ultradent Products), which achieved the patient's desired esthetic results.
Resumo:
Objective: The purpose of this study was to evaluate the effects of the platelet-rich plasma (PRP) when used in combination with autogenous bone graft and bioabsorbable membrane (Resolut® ) in the treatment of Class III furcation defects in dogs. Material and method: Class III furcation defects (5 mm in height and in depth) were surgically created in the mandibular third premolars of five mongrel dogs. After nine weeks, the lesions were treated with scaling and root planning and each defect received one of the following treatments: autogenous bone graft + membrane (group C) or PRP + autogenous bone graft + membrane (group T). After a healing period of 90 days, the animals were sacrificed. Routine histological processing and staining with hematoxilyn and eosin and Masson trichrome were performed and a histomorphometric analysis determined the effect of the treatments on periodontal tissue regereneration. Data were analyzed by Hotelling’s T-squared (p < 0.05). Result: No statistically significant difference between C and T groups was observed by the histomorphometric analysis of the furcation area. Both treatment groups demonstrated similar regenerative results with the furcation defects partially filled and periodontal regeneration limited to the experimental notches of the lesions. (p > 0.05). Conclusion: According to the present results, PRP does not enhance the periodontal regeneration in class III furcation defects treated with autogenous bone graft and bioabsorbable membrane.
Resumo:
The purpose of this study was to evaluate the effects of the platelet-rich plasma (PRP) when used in combination with autogenous bone graft and bioabsorbable membrane (Resolut® ) in the treatment of Class III furcation defects in dogs. Material and method: Class III furcation defects (5 mm in height and in depth) were surgically created in the mandibular third premolars of five mongrel dogs. After nine weeks, the lesions were treated with scaling and root planning and each defect received one of the following treatments: autogenous bone graft + membrane (group C) or PRP + autogenous bone graft + membrane (group T). After a healing period of 90 days, the animals were sacrificed. Routine histological processing and staining with hematoxilyn and eosin and Masson trichrome were performed and a histomorphometric analysis determined the effect of the treatments on periodontal tissue regereneration. Data were analyzed by Hotelling’s T-squared (p < 0.05). Result: No statistically significant difference between C and T groups was observed by the histomorphometric analysis of the furcation area. Both treatment groups demonstrated similar regenerative results with the furcation defects partially filled and periodontal regeneration limited to the experimental notches of the lesions. (p > 0.05). Conclusion: According to the present results, PRP does not enhance the periodontal regeneration in class III furcation defects treated with autogenous bone graft and bioabsorbable membrane.
Long-term clinical evaluation of the color stability and stainability of acrylic resin denture teeth
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Superficial stains and irregularities of the enamel are generally what prompt patients to seek dental intervention to improve their smile. These stains or defects may be due to hypoplasia, amelogenesis imperfecta, mineralized white spots, or fluorosis, for which enamel microabrasion is primarily indicated. Enamel microabrasion involves the use of acidic and abrasive agents, such as with 37% phosphoric acid and pumice or 6% hydrochloric acid and silica, applied to the altered enamel surface with mechanical pressure from a rubber cup coupled to a rotatory mandrel of a low-rotation micromotor. If necessary, this treatment can be safely combined with bleaching for better esthetic results. Recent studies show that microabrasion is a conservative treatment when the enamel wear is minimal and clinically imperceptible. The most important factor contributing to the success of enamel microabrasion is the depth of the defect, as deeper, opaque stains, such as those resulting from hypoplasia, cannot be resolved with microabrasion, and require a restorative approach. Surface enamel alterations that result from microabrasion, such as roughness and microhardness, are easily restored by saliva. Clinical studies support the efficacy and longevity of this safe and minimally invasive treatment. The present article presents the clinical and scientific aspects concerning the microabrasion technique, and discusses the indications for and effects of the treatment, including recent works describing microscopic and clinical evaluations.
Resumo:
Chemical disinfectants are usually associated with mechanical methods to remove stains and reduce biofilm formation. This study evaluated the effect of disinfectants on release of metal ions and surface roughness of commercially pure titanium, metal alloys, and heat-polymerized acrylic resin, simulating 180 immersion trials. Disk-shaped specimens were fabricated with commercially pure titanium (Tritan), nickel-chromium-molybdenum-titanium (Vi-Star), nickel-chromium (Fit Cast-SB Plus), and nickel-chromium-beryllium (Fit Cast-V) alloys. Each cast disk was invested in the flasks, incorporating the metal disk to the heat-polymerized acrylic resin. The specimens (n=5) were immersed in these solutions: sodium hypochlorite 0.05%, Periogard, Cepacol, Corega Tabs, Medical Interporous, and Polident. Deionized water was used as a control. The quantitative analysis of metal ion release was performed using inductively coupled plasma mass spectrometry (ELAN DRC II). A surface analyzer (Surftest SJ-201P) was used to measure the surface roughness (µm). Data were recorded before and after the immersions and evaluated by two-way ANOVA and Tukey's test (α=0.05). The nickel release proved most significant with the Vi-Star and Fit Cast-V alloys after immersion in Medical Interporous. There was a significant difference in surface roughness of the resin (p=0.011) after immersion. Cepacol caused significantly higher resin roughness. The immersion products had no influence on metal roughness (p=0.388). It could be concluded that the tested alloys can be considered safe for removable denture fabrication, but disinfectant solutions as Cepacol and Medical Interporous tablet for daily denture immersion should be used with caution because it caused greater resin surface roughness and greater ion release, respectively.
Resumo:
Three different fissure preparation procedures were tested and compared to the non-invasive approach using a conventional unfilled sealant and a flowable composite. Eighty permanent molars were selected and divided into 4 groups of 20 teeth each. All the teeth were split into 2 halves, and the exposed fissures were photographed under a microscope (35x) before and after being prepared using the following methods: (I) Er:YAG laser (KEY Laser, KaVo) 600 mJ pulse energy, 6 Hz; (II) diamond bur; (III) Er: YAG laser (KEY Laser, KaVo) 200 mJ pulse energy, 4 Hz; (IV) Control group: Powder jet cleaner (Prophyflex, KaVo, Germany). The pre-and postimages were superimposed in order to evaluate the amount of hard tissue removed. Ten teeth in each group were then acid etched and sealed with an unfilled sealant (Delton opaque, Dentsply), while the remaining 10 teeth were acid etched, primed and bonded (Prime ; Bond NT, Dentsply) and sealed with a flowable composite (X-flow, DeTrey, Dentsply). Material penetration and microleakage were evaluated after thermocycling (5000 cycles) and staining with methylene blue 5%. ANOVA and Mann-Whitney tests were applied for statistical analysis. The laser 600 mJ and bur eliminated the greatest amount of hard tissue. The control teeth presented the least microleakage when sealed with Delton or X-flow. A correlation between material penetration and microleakage could not be statistically confirmed. Mechanical preparation prior to fissure sealing did not enhance the final performance of the sealant.
Resumo:
Transmission electron microscopy has provided most of what is known about the ultrastructural organization of tissues, cells, and organelles. Due to tremendous advances in crystallography and magnetic resonance imaging, almost any protein can now be modeled at atomic resolution. To fully understand the workings of biological "nanomachines" it is necessary to obtain images of intact macromolecular assemblies in situ. Although the resolution power of electron microscopes is on the atomic scale, in biological samples artifacts introduced by aldehyde fixation, dehydration and staining, but also section thickness reduces it to some nanometers. Cryofixation by high pressure freezing circumvents many of the artifacts since it allows vitrifying biological samples of about 200 mum in thickness and immobilizes complex macromolecular assemblies in their native state in situ. To exploit the perfect structural preservation of frozen hydrated sections, sophisticated instruments are needed, e.g., high voltage electron microscopes equipped with precise goniometers that work at low temperature and digital cameras of high sensitivity and pixel number. With them, it is possible to generate high resolution tomograms, i.e., 3D views of subcellular structures. This review describes theory and applications of the high pressure cryofixation methodology and compares its results with those of conventional procedures. Moreover, recent findings will be discussed showing that molecular models of proteins can be fitted into depicted organellar ultrastructure of images of frozen hydrated sections. High pressure freezing of tissue is the base which may lead to precise models of macromolecular assemblies in situ, and thus to a better understanding of the function of complex cellular structures.
Resumo:
INTRODUCTION Agonistic antibodies targeting TRAIL-receptors 1 and 2 (TRAIL-R1 and TRAIL-R2) are being developed as a novel therapeutic approach in cancer therapy including pancreatic cancer. However, the cellular distribution of these receptors in primary pancreatic cancer samples has not been sufficiently investigated and no study has yet addressed the issue of their prognostic significance in this tumor entity. AIMS AND METHODS Applying tissue microarray (TMA) analysis, we performed an immunohistochemical assessment of TRAIL-receptors in surgical samples from 84 consecutive patients affected by pancreatic adenocarcinoma and in 26 additional selected specimens from patients with no lymph nodes metastasis at the time of surgery. The prognostic significance of membrane staining and staining intensity for TRAIL-receptors was evaluated. RESULTS The fraction of pancreatic cancer samples with positive membrane staining for TRAIL-R1 and TRAIL-R2 was lower than that of cells from surrounding non-tumor tissues (TRAIL-R1: p<0.001, TRAIL-R2: p = 0.006). In addition, subgroup analyses showed that loss of membrane staining for TRAIL-R2 was associated with poorer prognosis in patients without nodal metastases (multivariate Cox regression analysis, Hazard Ratio: 0.44 [95% confidence interval: 0.22-0.87]; p = 0.019). In contrast, analysis of decoy receptors TRAIL-R3 and -R4 in tumor samples showed an exclusively cytoplasmatic staining pattern and no prognostic relevance. CONCLUSION This is a first report on the prognostic significance of TRAIL-receptors expression in pancreatic cancer showing that TRAIL-R2 might represent a prognostic marker for patients with early stage disease. In addition, our data suggest that loss of membrane-bound TRAIL-receptors could represent a molecular mechanism for therapeutic failure upon administration of TRAIL-receptors-targeting antibodies in pancreatic cancer. This hypothesis should be evaluated in future clinical trials.
Resumo:
The last section, p. [95]-138, is entitled: "A letter to the right honorable the Earl of Morton, president of the Royal Society, containing experiments and observations on the agreement between the specific gravities of the several metals, and their colours when united to glass, as well as those of their other preparations. With additions. By Edward Delaval, F. R. S. Read at the Royal Society, Jan. 24, 1765."