965 resultados para Sphincter rupture


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the case of two patients hospitalized within a few weeks of each other and both presenting with spontaneous rupture of the esophagus whose evolution proved fatal. We take the opportunity of drawing attention to this rare and challenging disease, which is often diagnosed too late.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Control of hemorrhage in patients with active bleeding from rupture of the aortic arch is difficult, because of the location of the bleeding and the impossibility of cross-clamping the aorta without interfering with cerebral perfusion. A precise and swift plan of management helped us salvage some patients and prompted us to review our experience. METHODS: Six patients with active bleeding of the aortic arch in the mediastinum and pericardial cavity (5 patients) or left pleural cavity (1 patient), treated between 1992 and 1996, were reviewed. Bleeding was reduced by keeping the mediastinum under local tension (3 patients) or by applying compression on the bleeding site (2 patients), or both (1 patient) while circulatory support, retransfusion of aspirated blood, and hypothermia were established. The diseased aortic arch was replaced during deep hypothermic circulatory arrest, which ranged from 25 to 40 minutes. In 3 patients, the brain was further protected by retrograde (2 patients) or antegrade (1 patient) cerebral perfusion. RESULTS: Hemorrhage from the aortic arch was controlled in all patients. Two patients died postoperatively, one of respiratory failure and the other of abdominal sepsis. Recovery of neurologic function was assessed and complete in all patients. The 4 survivors are well 8 to 49 months after operation. CONCLUSIONS: An approach relying on local tamponade to reduce bleeding, rapid establishment of circulatory support and hypothermia, retransfusion of aspirated blood, and swift repair of the aortic arch under circulatory arrest allows salvage of patients with active bleeding from an aortic arch rupture.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La « surexploitation » des eaux souterraines est devenue au début des années 2000 une thématique majeure des programmes de développement des régions semi arides et arides de Syrie. Les fondements scientifiques du discours de surexploitation posent cependant question à plus d'un titre. Mobilisant une notion mal définie, le diagnostic de surexploitation réinterprète d'anciennes données soviétiques qui n'ont pas été actualisées. D'autre part, appliqué globalement à des espaces très hétérogènes, il n'apporte aucun élément d'évaluation et de régulation des pratiques d'exploitation. Les mesures de conservation des eaux souterraines qu'il justifie offrent alors un paradoxe. Présentées comme des mesures de restriction de l'exploitation des eaux souterraines, leur application dans les régions semi-arides a conduit à pénaliser les agriculteurs qui font l'usage le plus efficace de la ressource hydrique sans pour autant réduire la consommation en eau.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The usual treatment of blunt aortic injury (BAI) is prompt surgery. Frequently severe injuries to the brain or lungs exclude further surgical treatment. The purpose of this study is to assess the feasibility of placing endovascular stent-grafts. METHODS: From 1992 through 1999, in our primary and referral trauma center, 26 acute BAI, 21 males and 5 females, mean age 40.2+/-16.3 yrs were diagnosed. The last 4 patients underwent prospectively endovascular repair with Talent endograft. Endoprosthesis parameters were measured on three-dimensional spiral CT reconstruction. While waiting for devices, blood pressure was aggressively lowered and aortic lesions were monitored by transesophageal echography. RESULTS: Stent-graft deployment was successful in all 4 patients. There were no complications of endoleak, stent migration, paraplegia or death. Angiographic exclusion was complete in all 4 patients. CT scans at a mean follow-up of 11+/-5 months showed complete healing of the aortic wall in all patients. CONCLUSIONS: For stable acute BAI, endovascular stent-graft repair is feasible and safe, and is an effective therapeutic alternative to open surgery. Because of the normal proximal and distal wall in aortic injuries, endoluminal treatment might be the therapy of choice in the near future.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The treatment of the recently ruptured Achilles tendon can be conservative or surgical. The conservative treatment may be carried out using either a static cast immobilisation or using a dynamic brace and an early functional rehabilitation. The surgical technique can be either open or mini-invasive. Neglected and ancient ruptures may need to be treated surgically by a tendinoplasty. There is an ongoing discussion about how to manage the recently ruptured Achilles tendon, especially since recent descriptions of conservative-functional treatment procedures and mini-invasive surgical techniques. We present the choice of the different treatment options and the clinical reasoning to identify the best adapted treatment for the individual patient. The ideal treatment option depends on the functional demand and the medical condition of the patient.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Catheter-induced pulmonary artery rupture is an infrequent complication that may occur during invasive cardiopulmonary monitoring. Fatal cases are uncommon and result from hemoptysis and flooding of the opposite lung with resulting hypoyxia. Alpha-1-antitrypsin deficiency is a rare genetic disorder characterised by low serum levels of alpha-1-antitrypsin, critical in maintaining connective tissue integrity. Besides pulmonary emphysema, recent observations suggest that alpha-1-antitrypsin deficiency may also be involved in vascular wall weakening, thereby predisposing arteries to dissection and aneurysm formation. In this article, we describe an autopsy case of pulmonary artery iatrogenic rupture due to insertion of a Swan-Ganz catheter in an 82-year-old woman suffering from pulmonary hypertension and alpha-1-antitrypsin deficiency. The exact source of bleeding could not be precisely identified during autopsy due to the extent of tissue hemorrhage, though postmortem angiography revealed a contrast medium extravasation from a branch of the left pulmonary lower lobar artery. The case herein emphasises the importance of postmortem angiography in facilitating the detection of vascular injuries, the importance of familiarity with intensive care techniques and procedures on behalf of forensic pathologists as well as in-depth knowledge of all possible contributing conditions and predisposing disorders in the pathogenesis of death.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: There are only a few established artificial urinary sphincters for treatment of incontinence. We have developed a new device composed by three parts: the actuator, three contractile rings and a control unit. The actuator is made of Nitinol fibers, driven by microprocessor. The fibers are linked to the rings placed around the urethra. They function with alternance in their open and closed position. This concept is called piano concept. With this set-up, the constant compression on the urethra is strongly reduced. Methods: Six male sheep have been used for this study. The sphincter was open each hour for a period of 10 min., to guaranty urination. The bladder was filled with water while one cuff was closed and bladder pressure was monitored. The animals were sacrificed. Two biopsies around two cuffs of each explant and all three cuffs from each explant including urethra were analyzed. Urethra not surrounded by a cuff was taken as control. Results: The pressure exerted by the sphincter around the urethra provided continence. Simulated incontinence occurred at a pressure of 1bar measured on the bladder wall using a pressure probe. The closing force of the cuff was approx. 0·7N. No difference in tissue structure and organization of the urethra with and without artificial sphincter was observed. Conclusions: This device has several advantages compared to other urinary sphincters. It is easy to implant, has no hydraulic nature and reduces ischemic injury of the urethra by the alternance of urethral part compressed. Proof of concept in vivo has been demonstrated. Other studies are planned to determine long-term outcome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Injuries of peroneal tendons are rare. Diagnosis of traumatic rupture is often late and presents as chronic ankle instability. A case of a complete traumatic rupture of both peroneal longus and brevis tendons with acute clinical and radiological diagnosis is presented. Surgical repair was performed by direct end-to-end suture on the 4th day after trauma, with excellent functional outcome at 1-year follow-up.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction and objectives: The AMS 800TM is considered the gold standard for sphincter replacement. However, the one-ring design can erode the urethra and lead to severe complications. A mechanism that could alternatively compress successive segments of the urethra would limit such deleterious outcome. We report 12 weeks animal urethral tissue analysis following implantation of a new modular artificial sphincter. METHODS: The device is composed by three parts: the contractile unit, two rings and an integrated microprocessor. The contractile unit is made of Nitinol fibers. The rings are placed around the urethra to control the flow of urine by squeezing the urethra. They work in a sequential alternative mode and are controlled by a microprocessor connected to an external computer. The computer can reveal specific failure of device components. The device was impkanted in eight male sheep. The rings were positioned around the urethra and the control unit was placed 5cm away. The device was working twenty hours per day; it was open 10min. per hour to allow urination. The animals were sacrificed after 12 weeks. The urethra and the tissues surrounding the control unit were macroscopically and microscopically examined. Two transversal sections crossing the sphincter and two transversal sections crossing the urethra alone were obtained and stained with modified Paragon after resin embedding. Urethra was also embedded in paraffin. The first section was stained with safranin-hematoxylin-eosin, the second section was stained with Masson's Trichrome and the remaining eight sections were available for immunolabelling of the macrophages.Results: The chronic study went uneventful. No clinical infection or pain was observed. The computer registered no specific failure in ring function, Nitinol wires and tube connectors. At explantation, except for a slight grade of lymphocytes in two out of eight specimens, no urethral stricture or atrophy could be observed. Immunohistochemistry confirmed the absence of macrophages. Tissue structure and organization of the urethra with and without artificial sphincter were similar. No migration of the device was observed.Conclusions: The study clearly showed no tissue damage or inflammation of the urethra. Electronic design, preservation of urethral vascularisation and adjustability after implantation are the key ideas to improve the actual AUS. Further studies will be carried out to evaluate this potential.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Management of ischemic stroke in the presence of aneurysmal brain disease is controversial. Recent retrospective evidence suggests that in selected patients, intravenous thrombolysis (IVT) remains a safe approach for reperfusion. METHODS: We document a case of post-thrombolysis aneurysmal rupture. Supported by additional scientific literature we postulate that acute aneurysmal thrombosis leading to stroke in the culprit artery may be an ominous sign of rupture and should be considered separately from fortuitously discovered distant aneurysmal disease. RESULTS: A 71-year-old female presented with an acute right middle cerebral artery stroke syndrome. IVT allowed vessel reperfusion and revealed a previously concealed, juxtaposed non-giant M1 segment saccular aneurysm. Secondary aneurysmal rupture ensued. The aneurysm was secured by surgical clipping. Postoperative course was uneventful. CONCLUSIONS: This case shows that despite reports of thrombolysis safety in the presence of brain aneurysms, thrombolysis remains potentially hazardous and hints toward an increased risk when the stroke arises on the parent vessel itself.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Delayed rupture of the spleen following trauma is an exceedingly rare phenomenon in children. In the case we have experienced, arterial embolization was successfully performed, surgery was avoided, and functional splenic tissue was preserved. Embolization is of value in the management of blunt splenic injuries in hemodynamically stable children, even after delayed rupture. The exact criteria for its use remain to be established.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rotator cuff disease is the most common pathology causing shoulder pain with an overall prevalence rate of 30%. There is a significant association between increasing age and the presence of rotator cuff tears. Spontaneous healing of clinically relevant tears has not been observed. Although satisfactory pain relief is possible without rotator cuff tendon healing, functional outcome is better for healed repairs. Operative treatment must be considered in the context of the reasonable expectations for success. Repairability and potential of surgically tendon construct to heal are important considerations in surgical indications. There is no difference of outcomes between the arthroscopic and the open techniques.