966 resultados para Sound insulation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Building insulation is often used to reduce the conduction heat transfer through building envelope. With a higher level of insulation (or a greater R-value), the less the conduction heat would transfer through building envelope. In this paper, using building computer simulation techniques, the effects of building insulation levels on the thermal and energy performance of a sample air-conditioned office building in Australia are studied. It is found that depending on the types of buildings and the climates of buildings located, increasing the level of building insulation will not always bring benefits in energy saving and thermal comfort, particularly for internal-load dominated office buildings located in temperate/tropical climates. The possible implication of building insulation in face of global warming has also been examined. Compared with the influence of insulation on building thermal performance, the influence on building energy use is relatively small.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pipe insulation between the collector and storage tank on pumped storage (commonly called split), solar water heaters can be subject to high temperatures, with a maximum equal to the collector stagnation temperature. The frequency of occurrence of these temperatures is dependent on many factors including climate, hot water demand, system size and efficiency. This paper outlines the findings of a computer modelling study to quantify the frequency of occurrence of pipe temperatures of 80 degrees Celsius or greater at the outlet of the collectors for these systems. This study will help insulation suppliers determine the suitability of their materials for this application. The TRNSYS program was used to model the performance of a common size of domestic split solar system, using both flat plate and evacuated tube, selective surface collectors. Each system was modelled at a representative city in each of the 6 climate zones for Australia and New Zealand, according to AS/NZS4234 - Heat Water Systems - Calculation of energy consumption, and the ORER RECs calculation method. TRNSYS was used to predict the frequency of occurrence of the temperatures that the pipe insulation would be exposed to over an average year, for hot water consumption patterns specified in AS/NZS4234, and for worst case conditions in each of the climate zones. The results show; * For selectively surfaced, flat plate collectors in the hottest location (Alice Sprints) with a medium size hot water demand according to AS/NZS2434, the annual frequency of occurrence of temperatures at and above 80 degrees Celsius was 33 hours. The frequency of temperatures at and above 140 degrees Celsius was insignificant. * For evacuated tube collectors in the hottest location (Alice Springs), the annual frequency of temperatures at and above 80 degrees Celsius was 50 hours. Temperatures at and above 140 degrees Celsius were significant and were estimated to occur for more than 21 hours per year in this climate zone. Even in Melbourne, temperatures at and above 80 degrees can occur for 12 hours per year and at and above 140 degrees for 5 hours per year. * The worst case identified was for evacuated tube collectors in Alice Springs, with mostly afternoon loads in January. Under these conditions, the frequency of temperatures at and above 80 degrees Celsius was 10 hours for this month only. Temperatures at and above 140 degrees Celsius were predicted to occur for 5 hours in January.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Appropriate pipe insulation on domestic, pumped storage (split), solar water heating systems forms an integral part of energy conservation measures of well engineered systems. However, its importance over the life of the system is often overlooked. This study outlines the findings of computer modelling to quantify the energy and cost savings by using pipe insulation between the collector and storage tank. System sizes of 270 Litre storage tank, together with either selectively surfaced, flat plate collectors (4m2 area), or 30 evacuated tube collectors, were used. Insulation thicknesses of 13mm and 15mm, pipe runs both ways of 10, 15 and 20 metres and both electric and gas boosting of systems were all considered. The TRNSYS program was used to model the system performance at a representative city in each of the 6 climate zones for Australia and New Zealand, according to AS/NZS4234 – Heat Water Systems – Calculation of energy consumption and the ORER RECs calculation method. The results show:  Energy savings from pipe insulation are very significant, even in mild climates such as Rockhampton. Across all climates zones, savings ranged from 0.16 to 3.5GJ per system per year, or about 2 to 23 percent of the annual load.  There is very little advantage in increasing the insulation thickness from 13 to 15mm. For electricity at 19c/kWh and gas at 2 c/MJ, cost savings of between $27 and $100 per year are achieved across the climate zones. Both energy and cost savings would increase in colder climates with increased system size, solar contribution and water temperatures.  The pipe insulation substantially improves the solar contribution (or fraction) and Renewable Energy Certificates (RECs), as well as giving small savings in circulating pump running costs in milder climates. Solar contribution increased by up to 23 percent points and RECs by over 7 in some cases.  The study highlights the need to install and maintain the integrity of appropriate pipe insulation on solar water heaters over their life time in Australia and New Zealand.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Anna Hickey-Mody and Melissa Iocca invented a new name for the cinema-goer at "Bad Boy Bubby" (1993) when they wrote: "In de Heer's film, the viewer is primarily a listener, or aurator, and secondly a spectator" and I have argued the label 'aurator' can also be used for the person experiencing "Ten Canoes" (2006). This Aboriginal Australian Dreamtime fable features dialogue recorded entirely in the Ganalbingu language of the Indigenous people it stars, and is a prime example of what I would suggest can be labeled 'The Aboriginal Australian Films of Rolf de Heer'. "The Tracker" (2002) and "Dr. Plonk" (2007) have also included depictions of Aboriginal Australians and each of the trio utilizes Cat Hope's "innovative sound ideas" to present what I argue is an aural auteur's signature revealing a post-colonial Australian world-view that privileges the justice system and eco-spirituality of Aboriginal Australians.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Guy Webster is a sound artist who has been featured in numerous festivals, galleries, conferences and theatres in Australia, Japan, UK and Europe. As part of the Transmute Collective he developed the immersive soundscape of Intimate Transactions. On 2nd November, 2005 Jilliann Hamilton and Jeremy Yuille met with Guy Webster to discuss his approach to immersion in soundsapes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article compares YouTube and the National Film and Sound Archive (NFSA) as resources for television historians interested in viewing old Australian television programs. The author searched for seventeen important television programs, identified in a previous research project, to compare what was available in the two archives and how easy it was to find. The analysis focused on differences in curatorial practices of accessioning and cataloguing. NFSA is stronger in current affairs and older programs, while YouTube is stronger in game shows and lifestyle programs. YouTube is stronger than the NFSA on “human interest” material—births, marriages, and deaths. YouTube accessioning more strongly accords with popular histories of Australian television. Both NFSA and YouTube offer complete episodes of programs, while YouTube also offers many short clips of “moments.” YouTube has more surprising pieces of rare ephemera. YouTube cataloguing is more reliable than that of the NFSA, with fewer broken links. The YouTube metadata can be searched more intuitively. The NFSA generally provides more useful reference information about production and broadcast dates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In recent decades, assessment practices within Australian law schools have moved from the overwhelming use of end-of-year closed-book examinations to an increase in the use of a wider range of techniques. This shift is often characterised as providing a ‘better’ learning environment for students, contributing more positively to their own ‘personal development’ within higher education, or, considered along the lines of critical legal thought, as ‘liberating’ them from the ‘conservatising’ and ‘indoctrinating’ effects of the power relations that operate in law schools. This paper seeks to render problematic such liberal-progressive narratives about these changes to law school assessment practices. It will do so by utilising the work of French historian and philosopher Michel Foucault on power, arguing that the current range of assessment techniques demonstrates a shift in the ‘economy’ of power relations within the law school. Rather than ‘liberating’ students from relations of power, these practices actually extend the power relations through which students are governed. This analysis is intended to inform legal education research and assessment practice by providing a far more nuanced conceptual framework than one that seeks to ‘free’ law students from these ‘repressive’ practices, or hopes to ‘objectively’ contribute to their ‘personal development’.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Characteristics of modal sound radiation of finite cylindrical shells are studied using finite element and boundary element methods in this paper. In the low frequency range, modal radiation efficiencies of finite cylindrical shells are found to asymptotically approach those of the corresponding infinite cylindrical shell when structural trace wavelengths of the cylindrical shells are greater than the acoustic wavelength. Modal radiation efficiencies for each group of modes having the same circumferential modal index decrease as the axial modal index increases. They converge to each other when the axial trace wavelength is much greater than the circumferential trace wavelength. The mechanism leading to lower radiation efficiency of modes with higher circumferential modal index of short cylinders is explained. Similar to those of flat plate panels, change in slope or waviness is observed in modal radiation efficiency curves of modes with higher order axial modal index at medium frequencies. This is attributed to the interference of sound radiated by neighbouring vibrating cells when the distance between nodal lines of a vibrating mode is in the same order or smaller than the acoustic wavelength. Effects of the internal sound field on modal radiation efficiencies of a finite open-end cylinder are discussed.