984 resultados para Solar Plants


Relevância:

30.00% 30.00%

Publicador:

Resumo:

A common problem when planning large free field PV-plants is optimizing the ground occupation ratio while maintaining low shading losses. Due to the complexity of this task, several PV-plants have been built using various configurations. In order to compare the shading losses of different PV technologies and array designs, empirical performance data of five free field PV-plants operating in Germany was analyzed. The data collected comprised 140 winter days from October 2011 until March 2012. The relative shading losses were estimated by comparing the energy output of selected arrays in the front rows (shading-free) against that of shaded arrays in the back rows of the same plant. The results showed that landscape mounting with mc-Si PV-modules yielded significantly better results than portrait one. With CIGS modules, making cross-table strings using the lower modules was not beneficial as expected and had more losses than a one-string-per-table layout. Parallel substrings with CdTe showed relatively low losses. Among the two CdTe products analyzed, none showed a significantly better performance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The amount of solar energy made available for the production of a sabid seed varied as a function of the time of the year, the face of the plant in which, the position in the plant on which and the position in the pod in which it was produced.Variation in solar energy availability as a consequence of the time of the year was a direct consequence of latitude. At 21degrees5'22 S the highest amounts of Global Solar Radiation (GSR) reaching the site where the experiment was conducted took place during the months from November through February. During these months there were no marked differences between any two of the amounts of GSR reaching faces North (N), South (S), West (W) East (E). From February through November (period during which the sabid plants of this study flowered and the resulting seeds matured and were harvested) the total GSR's were the lowest and marked differences were found between faces N and S, with face N receiving much more GSR than face S. During that period, faces W and E received practically the same amount of GSR and it was much less than that received by face N and much more than the one received by face S.The amount of biological energy made available for the development of a seed seemed also to vary according to a dry matter partitioning strategy by the plant -the central third of the plant seemed to be the one receiving the highest amounts of energy, followed either by the upper or the lower third of the plant- it was not very clear which third of the plant immediately followed the central one. The partitioning of biological energy at the pod level also seemed to follow a strategy by which the central seeds would be the ones to receive more, followed by the proximal seeds and these by the distal ones.This availability of energy seemed to have a direct effect on seed size, weight and on the percentage of seeds which showed a degree of dormancy deep enough to prevent their germinating under the conditions of a standard germination test.The implications of these results for the improvement of methods for the overcoming of dormancy of sabia seeds are discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEB

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of this work was to evaluate the effects of UV-B radiation on the vegetative growth and on the gas exchange characteristics of passion fruit plants (Passiflora edulis) grown in greenhouse. The average unweighted UV-B radiation near the apex of the plants was 8 W m-2 for the UV-B treatment (high UV-B), and 0.8 W m-2 for the control plants (low UV-B). Plants were irradiated with UV-B for 7 hours per day, centered on solar noon, during 16 days. High UV-B radiation resulted in lower shoot dry matter accumulation per plant. The content of UV-B absorbing compounds and anthocyanins was increased in the plants exposed to high UV-B radiation, when compared with the control. UV-B radiation did not affect stomatal conductance or transpiration rate, but reduced photosynthesis and instantaneous water‑use efficiency, and increased intercellular CO2 concentration. The accumulation of UV-B-absorbing compounds and anthocyanins did not effectively shield plants from supplementary UV-B radiation, since the growth and photosynthetic processes were significantly reduced.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

[EN]A numerical model for the evaluation of solar radiation in different locations is presented. The solar radiation model is implemented taking into account the terrain surface using two-dimensional adaptive meshes of triangles that are constructed using a refinement/derefinement procedure in accordance with the variations of terrain surface and albedo. The selected methodology defines the terrain characteristics with a minimum number of points so that the computational cost is reduced for a given accuracy. The model can be used in atmospheric sciences as well as in other fields such as electrical engineering, since it allows the user to find the optimal location for maximum power generation in photovoltaic or solar thermal power plants...

Relevância:

30.00% 30.00%

Publicador:

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Young trees transplanted from nursery into open field require a minimum amount of soil moisture to successfully root in their new location, especially in dry-climate areas. One possibility is to obtain the required water from air moisture. This can be achieved by reducing the temperature of a surface below the air dew point temperature, inducing water vapor condensation on the surface. The temperature of a surface can be reduced by applying the thermoelectric effect, with Peltier modules powered by electricity. Here, we present a system that generates electricity with a solar photovoltaic module, stores it in a battery, and finally, it uses the electricity at the moment in which air humidity and temperature are optima to maximize water condensation while minimizing energy consumption. Also, a method to reduce the evaporation of the condensed water is proposed. The objective of the system, rather than irrigating young plants in such a degree as to boost their growth, is to maintain them alive in the dryer periods.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper details an investigation into the appearance of hot-spots in two large grid-connected photovoltaics (PV) plants, which were detected after the visual inspection of trackers whose energy output was decreasing at anomalous rate. Detected hot-spots appeared not only in the solar cells but also in resistive solder bonds (RSB) between cells and contact ribbons. Both types cause similar irreversible damage to the PV modules, but the latter are the main responsible for the detected decrease in energy output, which was confirmed in an experimental testing campaign. The results of this investigation, for example, how hot-spots were detected or their impact on the output power of PV modules, may be of interest for the routine maintenance of large grid-connected PV plants.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In order to complement ISFOC’s characterization capabilities, a Helios 3198 CPV Solar Simulator was installed in summer 2010. This Solar Simulator, based on a parabolic mirror and a high-intensity, small area Xenon flash lamp was developed by the Instituto de Energía Solar in Madrid [1] and is manufactured and distributed by Soldaduras Avanzadas [2]. This simulator is used not only for R&D purposes, but as a quality control tool for incoming modules that are to be installed in ISFOC’s CPV plants. In this paper we will discuss the results of recent measurements of close to 5000 modules, the entire production of modules corresponding to a small CPV power plant (200 kWp). We scrutinize the resultant data for signs of drift in the measurements, and analyze the light quality before and after, to check for changes in spectrum or spatial uniformity.)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Young trees transplanted from nursery into open field require a minimum amount of soil moisture to successfully root in their new location, especially in dry-climate areas. One possibility is to obtain the required water from air moisture. This can be achieved by reducing the temperature of a surface below the air dew point temperature, inducing water vapor condensation on the surface. The temperature of a surface can be reduced by applying the thermoelectric effect, with Peltier modules powered by electricity. Here, we present a system that generates electricity with a solar photovoltaic module, stores it in a battery, and finally, uses the electricity at the moment in which air humidity and temperature are optimal to maximize water condensation while minimizing energy consumption. Also, a method to reduce the evaporation of the condensed water is proposed. The objective of the system is to sustain young plants in drier periods, rather than exclusively irrigating young plants to boost their growth.