989 resultados para Soft liner material


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Polymerase chain reaction techniques were developed and applied to identify DNA from .40 species of prey contained in fecal (scat) soft-part matrix collected at terrestrial sites used by Steller sea lions (Eumetopias jubatus) in British Columbia and the eastern Aleutian Islands, Alaska. Sixty percent more fish and cephalopod prey were identified by morphological analyses of hard parts compared with DNA analysis of soft parts (hard parts identified higher relative proportions of Ammodytes sp., Cottidae, and certain Gadidae). DNA identified 213 prey occurrences, of which 75 (35%) were undetected by hard parts (mainly Salmonidae, Pleuronectidae, Elasmobranchii, and Cephalopoda), and thereby increased species occurrences by 22% overall and species richness in 44% of cases (when comparing 110 scats that amplified prey DNA). Prey composition was identical within only 20% of scats. Overall, diet composition derived from both identification techniques combined did not differ significantly from hard-part identification alone, suggesting that past scat-based diet studies have not missed major dietary components. However, significant differences in relative diet contributions across scats (as identified using the two techniques separately) reflect passage rate differences between hard and soft digesta material and highlight certain hypothesized limitations in conventional morphological-based methods (e.g., differences in resistance to digestion, hard part regurgitation, partial and secondary prey consumption), as well as potential technical issues (e.g., resolution of primer efficiency and sensitivity and scat subsampling protocols). DNA analysis of salmon occurrence (from scat soft-part matrix and 238 archived salmon hard parts) provided species-level taxonomic resolution that could not be obtained by morphological identification and showed that Steller sea lions were primarily consuming pink (Oncorhynchus gorbuscha) and chum (Oncorhynchus keta) salmon. Notably, DNA from Atlantic salmon (Salmo salar) that likely originated from a distant fish farm was also detected in two scats from one site in the eastern Aleutian Islands. Overall, molecular techniques are valuable for identifying prey in the fecal remains of marine predators. Combining DNA and hard-part identification will effectively alleviate certain predicted biases and will ultimately enhance measures of diet richness, fisheries interactions (especially salmon-related ones), and the ecological role of pinnipeds and other marine predators, to the benefit of marine wildlife conservationists and fisheries managers.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Clinical application of ozone gas has been shown to arrest the progression of dentinal caries in children. In this study, we compare the immediate effects of gaseous ozone and chlorhexidine gel on bacteria in cavitated carious lesions in children. Forty children, each with at least two open occlusal carious lesions, were enrolled in the study. Two teeth were chosen randomly. In one lesion, overlying soft biological material was removed, whilst the other lesion was not excavated. Cavities were rinsed with sterile water and dried with air. A standardised sample was taken from the mesial part of each lesion. Then, gaseous ozone (HealOzone) or 1% chlorhexidine gel (Corsodyl) was applied for 30 s on both lesions of 20 children each, and a second sample was taken from the distal part of each lesion. The anaerobic microbiota was cultivated; the number of colony forming units was calculated per milligram sample. The two-sided paired t test showed no significant (P > 0.05) differences in the reduction of total bacterial counts per milligram comparing samples before and after ozone or chlorhexidine application. The tests also showed no statistically significant difference whether the superficial decayed dentine had been removed before ozone or with chlorhexidine treatment or not. It can be concluded that gaseous ozone or chlorhexidine gel application for 30 s to deep occlusal carious cavities had no significant immediate antimicrobial effects whether the superficial decayed layers dentine were removed or not.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This case report describes the magnetic resonance imaging (MRI) findings and the treatment of a far lateral extrusion of disc material at the sixth and seventh lumbar vertebrae (L6-L7) in a five-year-old male Alpine Dachsbracke dog referred to our hospital for investigation of the complaint of a one week progressive lameness in the left pelvic limb and poorly localized back pain. An extra-foraminal left lateral disc herniation impinging on the sixth lumbar nerve root was diagnosed by MRI examinations. Due to the far lateral position of the extruded disc material on MRI, surgical opening of the spinal canal was not necessary. Removal of the herniated soft disc material impinging on the L6 nerve root, and fenestration of the L6-L7 disc was performed laterally. To the author's knowledge 'far-lateral' disc herniation beyond the neuroforamen without any spinal canal contact has not been described in dogs until now. A complete recovery with no evidence of pain was achieved only after a couple of weeks after surgery. We acknowledge that it is possible that other pathological mechanisms may have contributed to clinical signs and to a delayed recovery.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Interest in corneal biomechanics has increased with the development of new refractive surgery techniques aimed at modifying corneal properties and a variety of surgical options for corneal ectasia management. The human cornea behaves as soft biological material. It is a viscoelastic tissue and its response to a force applied to it depends not only on the magnitude of the force, but also on the velocity of the application. There are concerns about the limitations to measuring corneal biomechanical properties in vivo. To date, 2 systems are available for clinical use: the Ocular Response Analyzer, a dynamic bidirectional applanation device, and the Corvis ST, a dynamic Scheimpflug analyzer device. These devices are useful in clinical practice, especially for planning some surgical procedures and earlier detection of ectatic conditions, but further research is needed to connect the clinical measurements obtained with these devices to the standard mechanical properties.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Hydrogels may be described as cross~linked hydrophilic polymers that swell but do not dissolve in water. They have been utilised in many biomedical applications, as there is the potential to manipulate the properties for a given application by changing the chemical structure of the constituent monomers. This project is focused on the development of novel hydrogels for keratoprosthesis (KPro). The most commonly used KPro model consists of a tansparent central stem witb a porous peripheral skirt. Clear poly (methyl methacrylate) (PMMA) core material used in the Strampelli KPros prosthesis has not been the cause of failure found in other core and skirt prostheses. However, epithelialization of this kind of solid, rigid optic material is clearly impossible. The approach to the development of a hydrogeJ for potential KPro use adopted in this work is to develop soft core material to mimic the properties of the natural cornea by incorporating some hydrophilic monomers such as N, N-dimethyacrylamide (NNSMA) N~vinyl pyrrolidone (NVP) and acryloylmorpholine (AMO) with methyl methactylate (MMA). Most of these materials have been used in other ophthalmic applications, such as contact lens. However, an unavoidable limitation of simple .MMA copolymers as conventional hydrogels is poor mechanical strength. The hydrogel for use in this application must be able to withstand the stresses involved during the surgical procedure involved with KPro surgery and the in situ stresses such as the deforming force of the eyelid during the blink cycle. Thus, semi-interpenetrating polymer networks (SIPNs) based on ester polyurethane, AMO, NVP and NNDMA were examined in this work and were found to have much improved mechanical properties at water contents between 40% and 70%. Polyethylene glycol monomethacrylate (PEG MA) was successfully incorporated in order to modulate protein deposition and cell adhesion. Porous peripheral skirts were fabricated using different types of porosigen. The water content mechanical properties, surface properties and cell response of these various materials have been investigated in this thesis. These studies demonstrated that simple hydrogel SIPNs which show isotropic mechanical behaviour, are not ideal KPro materials since they do not mimic the anisotropic behaviour of natural cornea. The final stage of the work has concentrated on the study of hydrogels reinforced with mesh materials. They offer a promising approach to making a hydrogel that is very flexible but strong under tension, thereby having mechanical properties closer to the natural cornea than has been previously possible.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

As systems for computer-aided-design and production of mechanical parts have developed, there has arisen a need for techniques for the comprehensive description of the desired part, including its 3-D shape. The creation and manipulation of shapes is generally known as geometric modelling. It is desirable that links be established between geometric modellers and machining programs. Currently, unbounded APT and some bounded geometry systems are being widely used in manufacturing industry for machining operations such as: milling, drilling, boring and turning, applied mainly to engineering parts. APT systems, however, are presently only linked to wire-frame drafting systems. The combination of a geometric modeller and APT will provide a powerful manufacturing system for industry from the initial design right through part manufacture using NC machines. This thesis describes a recently developed interface (ROMAPT) between a bounded geometry modeller (ROMULUS) and an unbounded NC processor (APT). A new set of theoretical functions and practical algorithms for the computer aided manufacturing of 3D solid geometric model has been investigated. This work has led to the development of a sophisticated computer program, ROMAPT, which provides a new link between CAD (in form of a goemetric modeller ROMULUS) and CAM (in form of the APT NC system). ROMAPT has been used to machine some engineering prototypes successfully both in soft foam material and aluminium. It has been demonstrated above that the theory and algorithms developed by the author for the development of computer aided manufacturing of 3D solid modelling are both valid and applicable. ROMAPT allows the full potential of a solid geometric modeller (ROMULUS) to be further exploited for NC applications without requiring major investment in new NC processor. ROMAPT supports output in APT-AC, APT4 and the CAM-I SSRI NC languages.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Statement of problem. Two problems found in prostheses with soft liners are bond failure to the acrylic resin base and loss of elasticity due to material aging.Purpose. This in vitro study evaluated the effect of thermocycling on the bond strength and elasticity of 4 long-term soft denture liners to acrylic resin bases.Material and methods. Four soft lining materials (Molloplast-B, Flexor, Permasoft, and Pro Tech) and 2 acrylic resins (Classico, and Lucitone 199) were processed for testing according to manufacturers' instructions. Twenty rectangular specimens (10 X 10-mm(2) cross-sectional area) and twenty cylinder specimens (12.7-mm diameter X 19.0-mm height) for each liner/resin combination were used for the tensile and deformation tests, respectively. Specimen shape and liner thickness were standardized. Samples were divided into a test group that was thermocycled 3000 times and a control group that was stored for 24 hours in water at 37degreesC. Mean bond strength, expressed in megapascals (Wa), was determined in the tensile test with the use of a universal testing machine at a crosshead speed of 5 mm/min. Elasticity, expressed as percent of permanent deformation, was calculated with an instrument for measuring permanent deformation described in ADA/ANSI specification 18. Data from both tests were examined with 1-way analysis of variance and a Tukey test, with calculation of a Scheffe interval at a 95% confidence level.Results. In the tensile test under control conditions, Molloplast-B (1.51 +/- 0.28 MPa [mean SD]) and Pro Tech (1.44 +/- 0.27 MPa) liners had higher bond strength values than the others (P < .05). With regard to the permanent deformation test, the lowest values were observed for Molloplast-B (0.48% +/- 0.19%) and Flexor (0.44% +/- 0.14%) (P < .05). Under thermocycling conditions, the highest bond strength occurred with Molloplast-B (1.37 +/- 0.24 MPa) (P < .05) With regard to the deformation test, Flexor (0.46% +/- 0.13%) and Molloplast-B (0.44% +/- 0.17%) liners had lower deformation values than the others (P < .05).Conclusion. The results of this in vitro study indicated that bond strength and permanent deformity values of the 4 soft denture liners tested varied according to their chemical composition. These tests are not completely valid for application to dental restorations because the forces they encounter are more closely related to shear and tear. However, the above protocol serves as a good method of investigation to evaluate differences between thermocycled and control groups.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective: This study evaluated colour stability, hardness and roughness of soft denture liners after immersion in various cleansers. Materials and methods: Thirty specimens (14 mm x 4 mm) of Elite Soft Relining (ES) and Mucopren Soft (MS) were randomly immersed in distilled water at 37 degrees C, sodium hypochlorite 1%, and an experimental Ricinus communis solution (RC) for 7, 15 and 183 continuous days. Results: ANOVA (p < 0.05) and Tukey's test indicated that after T7 (mu =8.79 +/- 7.36); T15 (mu = 4.23 +/- 2.62) and T183 (mu = 8.78 +/- 3.16), MS presented a higher increase in hardness than ES. After T7, MS underwent an increase in roughness (mu = 0.09 +/- 0.80); ES underwent a decrease (mu = -0.08 +/- 0.16). RC caused the smallest variation in roughness. After T15, both materials presented an increase in roughness. After T183, ES (mu = -0.30 +/- 0.48) presented a higher roughness variation than MS (mu = -0.07 +/- 0.32). Hypochlorite caused an increase in roughness (mu = 0.02 +/- 0.19). Conclusion: After all periods ES presented higher colour alteration than MS; highest colour alteration was caused by hypochlorite. Both materials were more stable after immersion in RC.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this work, robustness and stability of continuum damage models applied to material failure in soft tissues are addressed. In the implicit damage models equipped with softening, the presence of negative eigenvalues in the tangent elemental matrix degrades the condition number of the global matrix, leading to a reduction of the computational performance of the numerical model. Two strategies have been adapted from literature to improve the aforementioned computational performance degradation: the IMPL-EX integration scheme [Oliver,2006], which renders the elemental matrix contribution definite positive, and arclength-type continuation methods [Carrera,1994], which allow to capture the unstable softening branch in brittle ruptures. The IMPL-EX integration scheme has as a major drawback the need to use small time steps to keep numerical error below an acceptable value. A convergence study, limiting the maximum allowed increment of internal variables in the damage model, is presented. Finally, numerical simulation of failure problems with fibre reinforced materials illustrates the performance of the adopted methodology.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this work, robustness and stability of continuum damage models applied to material failure in soft tissues are addressed. In the implicit damage models equipped with softening, the presence of negative eigenvalues in the tangent elemental matrix degrades the condition number of the global matrix, leading to a reduction of the computational performance of the numerical model. Two strategies have been adapted from literature to improve the aforementioned computational performance degradation: the IMPL-EX integration scheme [Oliver,2006], which renders the elemental matrix contribution definite positive, and arclength-type continuation methods [Carrera,1994], which allow to capture the unstable softening branch in brittle ruptures. The IMPL-EX integration scheme has as a major drawback the need to use small time steps to keep numerical error below an acceptable value. A convergence study, limiting the maximum allowed increment of internal variables in the damage model, is presented. Finally, numerical simulation of failure problems with fibre reinforced materials illustrates the performance of the adopted methodology.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: This study aimed to compare skeletal, dentoalveolar and soft tissue characteristics in white and black Brazilian subjects presenting normal occlusions. MATERIAL AND METHODS: The sample comprised the lateral cephalograms of 106 untreated Brazilian subjects with normal occlusion, divided into two groups: Group 1- 50 white subjects (25 of each gender), at a mean age of 13.17 years (standard deviation 1.07); and Group 2- 56 black subjects (28 of each gender), at a mean age of 13.24 years (standard deviation 0.56). Variables studied were obtained from several cephalometric analyses. Independent t tests were used for intergroup comparison and to determine sexual dimorphism. RESULTS: black subjects presented a more protruded maxilla and mandible, a smaller chin prominence and a greater maxillomandibular discrepancy than white subjects. Blacks presented a more horizontal craniofacial growth pattern than whites. Maxillary and mandibular incisors presented more protruded and proclined in black subjects. The nasolabial angle was larger in whites. Upper and lower lips were more protruded in blacks than in whites. CONCLUSIONS: The present study found a bimaxillary skeletal, dentoalveolar and soft tissue protrusion in black Brazilian subjects compared to white Brazilian subjects, both groups with normal occlusion. Upper and lower lips showed to be more protruded in blacks, but lip thickness was similar in both groups.