919 resultados para Signal amplitude


Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study aimed to analyze the electromyographic (EMG) activity of iliocostalis lumborum (IL), internal oblique (IO) and multifidus (MU) and the antagonist cocontraction (IO/MU and IO/IL) during the performance of Centering Principle of Pilates Method. Participating in this study were eighteen young and physically fit volunteers, without experience in Pilates Method, divided in two groups: low back pain group (LBPG, n = 8) and control group (CG, n = 10). Two isometric contractions of IO muscles (Centering Principle) were performed in upright sitting posture. EMG signal amplitude was calculated by Root Mean Square (RMS), which was normalized by RMS maximum value. The common area method to calculate the antagonist cocontraction index was used. MU and IO activation and IO/MU cocontraction (. p < 0.05) were higher in CG. The CG therefore showed a higher stabilizer muscles recruitment than LBPG during the performance of Centering Principle of Pilates Method. © 2012 Elsevier Ltd.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O objetivo desta tese foi desenvolver um magnetômetro à precessão nuclear para prospecção geofísica e estações-base magnéticas. O magnetômetro à precessão nuclear mede a intensidade total do campo magnético. Seu funcionamento é baseado na ressonância magnética nuclear. A medida de campo é feita pela de terminação da freqüência de precessão de núcleos de hidrogênio – prótons - de líquidos não viscosos no campo magnético terrestre. O magnetômetro é constituído de duas partes: o sensor e o instrumento de medida. O sensor é uma bobina solenoidal, cujo núcleo é preenchido com o líquido. Três líquidos diferentes foram testados; água, propanol e um querosene sintético. Optou-se pelo uso do querosene porque oferece maior amplitude no sinal de precessão, dando, conseqüentemente, maior relação sinal/ ruído. O sistema de medida contém os circuitos de sintonia e amplificação do sinal e, os circuitos lógicos para a programação da operação e contagem da freqüência de precessão. Cada ciclo de medida tem duração de 3 segundos, sendo 2,3s para a polarização e 0,7s para a recepção do sinal. São possíveis dois modos de operação: manual, reciclando automaticamente e por controle remoto. O sinal de precessão é amplificado seletivamente em uma das 14 faixas de sintonia, que cobrem medidas entre 22000 e 95000 gammas. A freqüência de precessão é multiplicada por um fator de 64 e contada durante um tempo igual a 0,36699s, determinado com base na razão giromagnética do próton. O número de pulsos contados é numericamente igual ao valor do campo magnético em gammas. A resposta pode ser lida em mostradores digitais ou na saída BCD paralela quando operando por controle remoto. A precisão da medida é de 1 gamma. O instrumento foi testado no campo para avaliar a relação sinal/ruído, gradiente suportável e consumo de potência. Nos testes de aplicação do protótipo, foram obtidos dados de variação diurna e realizaram-se levantamentos magnético de reconhecimento e detalhe em um sítio arqueológico na Ilha de Marajó, Pará. As respostas dos testes foram comparados com dois magnetômetros comerciais - o GP-70, McPhar e o G-816, Geometrics e, ainda, com dados do Observatório Magnético de Tatuoca-Pa. Em todos os casos, a comparação dos dados mostrou bom desempenho do magnetômetro em teste.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We investigate the strong magnetic and gravity anomalies of the Goias Alkaline Province (GAP), a region of Late Cretaceous alkaline magmatism along the northern border of the Parana Basin, Brazil. The alkaline complexes (eight of which are present in outcrops, two others inferred from magnetic signals) are characterized by a series of small intrusions forming almost circular magnetic and gravimetric anomalies varying from -4000 to +6000 nT and from -10 to +40 mGal, respectively. We used the Aneuler method and Analytical Signal Amplitude to obtain depth and geometry for mapped sources from the magnetic anomaly data. These results were used as the reference models in the 3D gravity inversion. The 3D inversion results show that the alkaline intrusions have depths of 10-12 km. The intrusions in the northern GAP follow two alignments and have different sizes. In the anomaly magnetic map, dominant guidelines correlate strongly with the extensional regimes that correlate with the rise of alkaline magmatism. The emplacement of these intrusions marks mechanical discontinuities and zones of weakness in the upper crust. According to the 3D inversion results, those intrusions are located within the upper crust (from the surface to 18 km depth) and have spheres as the preferable geometry. Such spherical shapes are more consistent with magmatic chambers instead of plug intrusions. The Registro do Araguaia anomaly (similar to 15 by 25 km) has a particular magnetic signature that indicates that the top is deeper than 1500 m. North of this circular anomaly are lineaments with structural indices indicating contacts on their edges and dikes/sills in the interiors. Results of 3D inversion of magnetic and gravity data suggest that the Registro do Araguaia is the largest body in the area, reaching 18 km depth and indicating a circular layered structure. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Array seismology is an useful tool to perform a detailed investigation of the Earth’s interior. Seismic arrays by using the coherence properties of the wavefield are able to extract directivity information and to increase the ratio of the coherent signal amplitude relative to the amplitude of incoherent noise. The Double Beam Method (DBM), developed by Krüger et al. (1993, 1996), is one of the possible applications to perform a refined seismic investigation of the crust and mantle by using seismic arrays. The DBM is based on a combination of source and receiver arrays leading to a further improvement of the signal-to-noise ratio by reducing the error in the location of coherent phases. Previous DBM works have been performed for mantle and core/mantle resolution (Krüger et al., 1993; Scherbaum et al., 1997; Krüger et al., 2001). An implementation of the DBM has been presented at 2D large-scale (Italian data-set for Mw=9.3, Sumatra earthquake) and at 3D crustal-scale as proposed by Rietbrock & Scherbaum (1999), by applying the revised version of Source Scanning Algorithm (SSA; Kao & Shan, 2004). In the 2D application, the rupture front propagation in time has been computed. In 3D application, the study area (20x20x33 km3), the data-set and the source-receiver configurations are related to the KTB-1994 seismic experiment (Jost et al., 1998). We used 60 short-period seismic stations (200-Hz sampling rate, 1-Hz sensors) arranged in 9 small arrays deployed in 2 concentric rings about 1 km (A-arrays) and 5 km (B-array) radius. The coherence values of the scattering points have been computed in the crustal volume, for a finite time-window along all array stations given the hypothesized origin time and source location. The resulting images can be seen as a (relative) joint log-likelihood of any point in the subsurface that have contributed to the full set of observed seismograms.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A novel design based on electric field-free open microwell arrays for the automated continuous-flow sorting of single or small clusters of cells is presented. The main feature of the proposed device is the parallel analysis of cell-cell and cell-particle interactions in each microwell of the array. High throughput sample recovery with a fast and separate transfer from the microsites to standard microtiter plates is also possible thanks to the flexible printed circuit board technology which permits to produce cost effective large area arrays featuring geometries compatible with laboratory equipment. The particle isolation is performed via negative dielectrophoretic forces which convey the particles’ into the microwells. Particles such as cells and beads flow in electrically active microchannels on whose substrate the electrodes are patterned. The introduction of particles within the microwells is automatically performed by generating the required feedback signal by a microscope-based optical counting and detection routine. In order to isolate a controlled number of particles we created two particular configurations of the electric field within the structure. The first one permits their isolation whereas the second one creates a net force which repels the particles from the microwell entrance. To increase the parallelism at which the cell-isolation function is implemented, a new technique based on coplanar electrodes to detect particle presence was implemented. A lock-in amplifying scheme was used to monitor the impedance of the channel perturbed by flowing particles in high-conductivity suspension mediums. The impedance measurement module was also combined with the dielectrophoretic focusing stage situated upstream of the measurement stage, to limit the measured signal amplitude dispersion due to the particles position variation within the microchannel. In conclusion, the designed system complies with the initial specifications making it suitable for cellomics and biotechnology applications.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The last half-century has seen a continuing population and consumption growth, increasing the competition for land, water and energy. The solution can be found in the new sustainability theories, such as the industrial symbiosis and the zero waste objective. Reducing, reusing and recycling are challenges that the whole world have to consider. This is especially important for organic waste, whose reusing gives interesting results in terms of energy release. Before reusing, organic waste needs a deeper characterization. The non-destructive and non-invasive features of both Nuclear Magnetic Resonance (NMR) relaxometry and imaging (MRI) make them optimal candidates to reach such characterization. In this research, NMR techniques demonstrated to be innovative technologies, but an important work on the hardware and software of the NMR LAGIRN laboratory was initially done, creating new experimental procedures to analyse organic waste samples. The first results came from soil-organic matter interactions. Remediated soils properties were described in function of the organic carbon content, proving the importance of limiting the addition of further organic matter to not inhibit soil processes as nutrients transport. Moreover NMR relaxation times and the signal amplitude of a compost sample, over time, showed that the organic matter degradation of compost is a complex process that involves a number of degradation kinetics, as a function of the mix of waste. Local degradation processes were studied with enhanced quantitative relaxation technique that combines NMR and MRI. The development of this research has finally led to the study of waste before it becomes waste. Since a lot of food is lost when it is still edible, new NMR experiments studied the efficiency of conservation and valorisation processes: apple dehydration, meat preservation and bio-oils production. All these results proved the readiness of NMR for quality controls on a huge kind of organic residues and waste.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: An age-controlled comparison concerning patient satisfaction and electrical performance of microfibres (DTL) and rigid contact lens (Henkes) corneal ERG electrodes was carried out. METHODS: 36 test persons underwent complete ophthalmological examination and were equally distributed into 3 age groups. Electroretinograms were recorded according to ISCEV standards. Randomly, in one eye a Henkes electrode was used and in the other eye a DTL electrode. Amplitudes of a- and b-waves and implicit times were measured and compared for the two electrode types. RESULTS: 34 of 36 test persons preferred DTL electrodes. Electrical performance concerning b-wave amplitudes was comparable. Statistically significant differences were detected only for scotopic combined cone-rod stimulation in the age groups 20 - 40 and 41 - 60 years between the different electrodes. Other recordings did not show differences. A statistically significant reduction of signal amplitudes with age was detected for scotopic isolated rod signals and combined cone-rod signals. Significance level was p < 0.05. No conjunctival or corneal erosions were found after ERG recordings for either electrode. CONCLUSIONS: Electrical performance is comparable between electrodes. For scotopic stimulations age was a significant influencing factor for signal amplitude and should be respected for normative values. DTL electrodes were preferred by the vast majority of patients. No adverse clinical effects were observed for either electrode. DTL electrodes should be preferred due to hygienic reasons (single use) and patient comfort.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In general, vascular contributions to the in vivo magnetic resonance (MR) brain spectrum are too small to be relevant. In cerebral uptake studies, however, vascular contributions may constitute a major confounder. MR visibility of vascular Phe was investigated by recording localized spectra from fully oxygenated and well-mixed whole blood. Blood Phe levels determined by MR spectroscopy (MRS) and ion-exchange chromatography showed excellent correlation. In addition, effects of blood flow were shown to have a small effect on signal amplitude with the MRS methodology used. Hence, blood Phe is almost completely MR visible at 1.5 T, even though it is severely broadened at higher fields. Without appropriate correction, cerebral Phe influx in studies of brain Phe uptake in phenylketonuria patients or healthy subjects would appear to be faster and lead to higher levels. Similar effects are envisaged for studies of ethanol or glucose uptake across the blood-brain barrier.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

For clinical optoacoustic imaging, linear probes are preferably used because they allow versatile imaging of the human body with real-time display and free-hand probe guidance. The two-dimensional (2-D) optoacoustic image obtained with this type of probe is generally interpreted as a 2-D cross-section of the tissue just as is common in echo ultrasound. We demonstrate in three-dimensional simulations, phantom experiments, and in vivo mouse experiments that for vascular imaging this interpretation is often inaccurate. The cylindrical blood vessels emit anisotropic acoustic transients, which can be sensitively detected only if the direction of acoustic radiation coincides with the probe aperture. Our results reveal for this reason that the signal amplitude of different blood vessels may differ even if the vessels have the same diameter and initial pressure distribution but different orientation relative to the imaging plane. This has important implications for the image interpretation, for the probe guidance technique, and especially in cases when a quantitative reconstruction of the optical tissue properties is required.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In previous works we demonstrated the benefits of using micro–nano patterning materials to be used as bio-photonic sensing cells (BICELLs), referred as micro–nano photonic structures having immobilized bioreceptors on its surface with the capability of recognizing the molecular binding by optical transduction. Gestrinone/anti-gestrinone and BSA/anti-BSA pairs were proven under different optical configurations to experimentally validate the biosensing capability of these bio-sensitive photonic architectures. Moreover, Three-Dimensional Finite Difference Time Domain (FDTD) models were employed for simulating the optical response of these structures. For this article, we have developed an effective analytical simulation methodology capable of simulating complex biophotonic sensing architectures. This simulation method has been tested and compared with previous experimental results and FDTD models. Moreover, this effective simulation methodology can be used for efficiently design and optimize any structure as BICELL. In particular for this article, six different BICELL's types have been optimized. To carry out this optimization we have considered three figures of merit: optical sensitivity, Q-factor and signal amplitude. The final objective of this paper is not only validating a suitable and efficient optical simulation methodology but also demonstrating the capability of this method for analyzing the performance of a given number of BICELLs for label-free biosensing.