962 resultados para Scanning reference electrode technique


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new type of ion-selective electrode-water membrane system is proposed and an assumption of water membrane is confirmed. A NdCl_3 water membrane electrode has be- en made te demonstrate its applicability to the determination of Nd (PMBP)_3 (PMBP=1- phenyl-3-methyl-4-benzoyl-5-pyrazolone)in cyclohexanone. Conditions for stabilizing potential of reference electrode in nonaqueous system are optimized. It is observed that the potential response on the surface of two immiscible solution is bidirection...

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Price, T., Urquhart, C. & Cooper, J. (2007). Using a prompt sheet to improve the reference interview in a health telephone helpline service. Evidence Based Library and Information Practice, 2(3), 43-58 Open access journal

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A bluish-black shining free standing polypyrrole film (PPy) of electronic conductivity 130 S cm-1 has been prepared by electrochemical oxidative polymerization of pyrrole on Pt/transparent glass conducting electrode resistance 15 O cm-1, using a room temperature melt as an electrolyte, composed of 1:3 stoichiometric ratio of cetyl pyridinium chloride and anhydrous aluminum chloride at 0.58 V versus Al wire as a reference electrode. The film possessed a charge transfer resistance of 132 O, and showed two absorption peaks at 457 and 1264 nm in the UV-vis–NIR diffused reflectance spectra. The morphology of the film was hexagonal. The potential step technique suggested a layered structure. This thin film can easily be peeled off from the electrode surface after three cycles and can be used for various applications like dissipation of electrostatic charge, battery electrode materials, solid electrolytic capacitor, electrochromic windows and displays, microactuators etc. It was also characterized by IR, thermal and SEM studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The voltammetry and kinetics of the Ag vertical bar Ag+ system (commonly used as a reference electrode material in both protic/aprotic and RTIL solvents) was studied in the room-temperature ionic liquid N-butyl-N-methylpyrrolidinium bis(trifluoromethylsulfonyl)imide, [C(4)mpyrr][NTf2] on a 10 mu m diameter Pt electrode. For the three silver salts investigated (AgOTf, AgNTf2, and AgNO3, where OTf- = trifluoromethanesulfonate, NTf2- = bis(trifluoromethylsulfonyl)imide, and NO3- = nitrate), the voltammetry gave rise to a redox couple characteristic of a

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work describes the electrochemical methodology for the determination of the Donnan potential from diffusion-limited steady-state voltammograms of acrylamide gels. The technique is based upon the measurement of gel–sol systems that have reached Donnan equilibrium and contain Cd2+ as a probe ion. Au-amalgam microelectrodes are used to measure the Cd concentration in the gel phase relative to the solution phase, thus permitting comparison of the Cd voltammograms obtained in both phases. This approach yields two independent measures of the Donnan potential resulting from (i) the potential shift relative to the reference electrode, and (ii) the enhancement of the Cd2+ wave. Two suites of acrylamide gels containing 0.2% and 0.5% Na-acrylate were studied as a function of ionic strength by varying [NaNO3] and maintaining a constant concentration of the electroactive probe ion, [Cd2+] = 1 · 10 5 mol/L in the equilibrating solutions. Independent model predictions of the Donnan potential as a function of ionic strength that consider the effects of differential swelling on the charge density, the influence of a mixed electrolyte on the potential developed in the gel at the limit of low ionic strength and the effects of incomplete dissociation of the carboxylic functional groups were in agreement with the Donnan potentials independently measured by the twofold steady-state voltammetric approach.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Química e Biológica - Processos Químicos

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The potential of a quasi-reference electrode can be determined by introducing an internal reference redox system (IRRS) which comprises either the oxidizable or reducible form of a reversible (and, ideally, outer-sphere) redox couple and then observing the cyclic voltammetric responses. The objective is to choose the IRRS so that the cyclic voltammetric response for the simultaneously present electroactive analyte system (ANS) can be observed independently of the IRRS response. We identify three fundamental paradigms describing the relative positioning of the IRRS and ANS on the potential scale, the operative redox components for the IRRS and ANS, and the starting potential (E start), reversing potential (E rev), and ending potential (E end) for the cyclic voltammetric scan as follows: paradigm A, an optimal paradigm which can produce completely independent cyclic voltammetric responses for the IRRS or for ANS; paradigm B, a less-than-optimal paradigm which can produce an independent cyclic voltammetry (CV) response for the ANS or a mixed response for the IRRS with that response on top of the ANS response; paradigm C, a problematic paradigm that can produce an independent CV response for the IRRS or a mixed response for the ANS with that response on top of the IRRS response; and any mixed response produces a thermodynamically favored redox cross-reaction which couples the IRRS and ANS systems and which can complicate the analysis of the ANS and IRRS responses. The conclusion is that paradigm C is to be avoided.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Bi-functional oxygen electrodes are an enabling component for rechargeable metal-air batteries and regenerative fuel cells, both of which are regarded as the next-generation energy devices with zero emission. Nonetheless, at the present, no single metal oxide component can catalyze both oxygen reduction reaction (ORR) and oxygen evolution reaction (OER) with high performance which leads to large overpotential between ORR and OER. This work strives to address this limitation by studying the bi-functional electrocatalytic activity of the composite of a good ORR catalyst compound (e.g. palladium oxide, PdO) and a good OER catalyst compound (e.g. ruthenium oxide, RuO2) in alkaline solution (0.1M KOH) utilizing a thin-film rotating disk electrode technique. The studied compositions include PdO, RuO2, PdO/RuO2 (25wt.%/75wt.%), PdO/RuO2 (50wt.%/50wt.%) and PdO/RuO2 (75wt.%/25wt.%). The lowest overpotential (e.g. E (2 mA cm−2) - E (-2 mA cm−2)) of 0.82 V is obtained for PdO/RuO2 (25wt.%/75wt.%) (versus Ag|AgCl (3M NaCl) reference electrode).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Biopsy by fine needle aspiration together with microbiological examination and scanning electron microscopy were evaluated in diagnosis of clinical bovine mastitis in a Prototheca zopfii outbreak. Fine needle aspiration was performed in 21 mammary quarters from ten Holstein cows presenting clinical mastitis caused by P. zopfii. The algae were previously identified in the microbiological examination of milk collected from these cows. Material aspirated from these 21 mammary glands was submitted to cytological staining (Gram, Giemsa and/or Shor staining). Fine needle aspiration enabled cytological identification of the algae in these 21 mammary glands, from which P. zopfii was isolated in the milk. Simultaneously, five mammary fragments collected by fine needle aspiration from these 21 mammary glands presenting clinical mastitis were also submitted to microbiological examination. P. zopfii was also isolated from these five fragments. Scanning electron microscopy technique also identified three of these five P. zopfii strains isolated from mammary fragments collected by cytological aspiration. These results suggest that fine needle aspiration may be an alternative method for the diagnosis of clinical mastitis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The presence of trace neutral organonitrogen compounds as carbazole and indole in derivative petroleum fuels plays an important role in the car's engine maintenance. In addition, these substances contribute to the environmental contamination and their control is necessary because most of them are potentially carcinogenic and mutagenic. For those reasons, a reliable and sensitive method was proposed for the determination of neutral nitrogen compounds in fuel samples, such as gasoline and diesel using preconcentration with modified silica gel (Merck 70-230 mesh ASTM) followed by differential pulse voltammetry (DPV) technique on a glassy carbon electrode. The electrochemical behavior of carbazole and indole studied by cyclic voltammetry (CV) suggests that their reduction occurs via a reversible electron transfer followed by an irreversible chemical reaction. Very well resolved diffusion controlled voltammetric peaks were obtained in dimethylformamide (DMF) with tetrabutylammonium tetrafluoroborate (TBAF(4) 0.1 mol L-1) for indole (-2.27 V) and carbazole (-2.67 V) versus Ag vertical bar AgCl vertical bar KClsat reference electrode. The proposed DPV method showed a good linear response range from 0.10 to 300 mg L-1 and a limit of detection (L.O.D) of 7.48 and 2.66 mu g L-1 for indole and carbazole, respectively. The results showed that simultaneous determination of indole and carbazole presents in spiked gasoline samples were 15.8 +/- 0.3 and 64.6 +/- 0.9 mg L-1 and in spiked diesel samples were 9.29 +/- 1 and 142 +/- 1 mg L-1, respectively. The recovery was evaluated and the results shown the values of 88.9 +/- 0.4 and 90.2 +/- 0.8% for carbazole and indole in fuel determinations. The proposed method was also compared with UV-vis spectrophotometric measures and the results obtained for the two methods were in good agreement according to the F and t Student's tests. (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tetradifon, a potentially carcinogenic and mutagenic pesticide, can contribute to environmental and human contamination when applied to green bell pepper crops. In this context, in this work, a reliable and sensitive method for determination of tetradifon in Brazilian green bell pepper samples involving a differential pulse voltammetry (DPV) technique on a glassy carbon electrode is proposed. The electrochemical behavior of tetradifon as followed by cyclic voltammetry (CV) suggests that its reduction occurs via an irreversible five–electron transfer vs. Ag|AgCl, KCl 3 M reference electrode. Very well–resolved diffusion controlled voltammetric peaks have been obtained in a supporting electrolyte solution composed of a mixture of 40% dimethylformamide (DMF), 30% methanol, and 30% NaOH 0.3 mol L−1 at −1.43, −1.57, −1.73, −1.88, and −2.05 V. The proposed DPV method has a good linear response in the 3.00 – 10.0 μmol L−1 range, with a limit of detection (L.O.D) of 0.756 μmol L−1 and 0.831 μmol L−1 in the absence and in the presence of the matrix, respectively. Moreover, improved L.O.D results (0.607 μmol L−1) have been achieved in the absence of DMF from the supporting electrolyte solution. Recovery has been evaluated in five commercial green bell pepper samples, and recovery percentages ranging from 91.0 to 109 have been obtained for tetradifon determinations. The proposed voltammetric method has also been tested for reproducibility, repeatability, and potential interferents, and the results obtained for these three analytical parameters are satisfactory for electroanalytical purposes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tetradifon, a potentially carcinogenic and mutagenic pesticide, can contribute to environmental and human contamination when applied to green bell pepper crops. In this context, in this work, a reliable and sensitive method for determination of tetradifon in Brazilian green bell pepper samples involving a differential pulse voltammetry (DPV) technique on a glassy carbon electrode is proposed. The electrochemical behavior of tetradifon as followed by cyclic voltammetry (CV) suggests that its reduction occurs via an irreversible five-electron transfer vs. Ag vertical bar AgCl, KCl 3 M reference electrode. Very well-resolved diffusion controlled voltammetric peaks have been obtained in a supporting electrolyte solution composed of a mixture of 40% dimethylformamide (DMF), 30% methanol, and 30% NaOH 0.3 mol L-1 at -1.43, -1.57, -1.73, -1.88, and -2.05 V. The proposed DPV method has a good linear response in the 3.00 - 10.0 mu mol L-1 range, with a limit of detection (L.O.D) of 0.756 mu mol L-1 and 0.831 mu mol L-1 in the absence and in the presence of the matrix, respectively. Moreover, improved L.O.D results (0.607 mu mol L-1) have been achieved in the absence of DMF from the supporting electrolyte solution. Recovery has been evaluated in five commercial green bell pepper samples, and recovery percentages ranging from 91.0 to 109 have been obtained for tetradifon determinations. The proposed voltammetric method has also been tested for reproducibility, repeatability, and potential interferents, and the results obtained for these three analytical parameters are satisfactory for electroanalytical purposes. (C) 2012 The Electrochemical Society. [DOI: 10.1149/2.024207jes] All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The use of standard reference electrodes, such as Ag/AgCl or saturated calomel electrodes, in potentiometric and amperometric studies involving miniaturized electrochemical systems, or those operating under positive hydraulic pressure, is often impractical. Placement of the reference electrode in the direct vicinity of the working electrode is often prohibited by the dimensions or layout of the electrochemical cell, while the alternative strategy of locating the reference electrode in a separate compartment often leads to electrolyte leakage and contamination of the system. In the present study, we have investigated the functionality of a pseudoreference electrode comprising a platinum wire, one end of which was maintained in intimate contact with the internal solution of an Ag/AgCl reference electrode while the other was connected, via a BNC connector, to a platinum probe located within the electrochemical cell. Linear and cyclic voltammetric studies, involving both aqueous and nonaqueous electrolytes, were carried out using the pseudoreference electrode and an electrochemical cup-type cell with three electrodes or an electrochemical flow reactor. In all cases, the functionality of the Pt//Ag/AgCl system was similar to that of a conventional Ag/AgCl reference electrode. Variations in the electrolyte did not alter the potential or voltammetric profile recorded when using the pseudoreference system, although peak currents were generally improved and potential values shifted by approximately +350 mV in comparison with the Ag/AgCl electrode, therefore, the system pseudoreference can be applied in any electrochemical system due to the constant potential difference. It is concluded that the pseudoreference electrode can be used with advantage to obtain potentiometric and amperometric measurements in both simple and complex electrochemical systems.