991 resultados para Saudi Building Code


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The use of mineral wool is becoming more widespread due to increased acoustic and thermal demands of Spanish Technical Building Code. This increase affects both in rehabilitation and new construction projects. Therefore, waste generation of this type of insulating material is having more importance. The main objective of this research is to study the possibility of recycling fiber obtained from mineral wool of the C&DW as an alternative material to chopped glass fibers that are currently used as reinforcing elements in the prefabricated plaster. To achieve this objective, series are made of plaster E-35 additived with rock wool residue and glass wool residue at different rates of addition. These series are repeated by changing the additive by E fiberglass (length of 25mm) to make a comparative analysis with respect to the series additived with mineral wool waste. All the series are subjected to the test to determine Shore C surface hardness and mechanical testing to determine the compressive and flexural strength. From the results it can be concluded that: with rock wool residue, increases Shore C hardness up to 15% with respect to the glass fiber and 9% with respect to the glass wool, with a percentage of addition 2%. With rock wool residue, weight is decreased by 5% with respect to the glass fiber and 4% with respect to the glass wool waste, with an addition percentage of 4%. For an addition rate of 4%, results in the flexural strength test with fiberglass are 85% higher than those obtained with glass wool residue. However, for a percentage of 1% addition, the results obtained with glass wool residue are 35% higher than those obtained with fiberglass. For an addition rate of 3% results in the compressive strength test with fiberglass are 54% lower than those obtained with rock wool waste and 70% lower than those obtained with glass wool waste. Comparing the two mineral wools, it can be concluded that up to 3% of the addition, the glass wool series results obtained are 10% higher than those additived with rock wool. However, higher percentages of addition show that the results obtained with rock wool are 35% higher than those obtained with glass wool. The general conclusion is that the series additived with mineral wool from C&DW show better results in tests than the ones used nowadays as plaster reinforcement.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

RESUMEN Su objetivo esencial: Regular el proceso de la edificación, está basado en 3 grandes pilares: 1.- Completar la configuración legal de los agentes que intervienen en el mismo, fijando sus obligaciones para así establecer las responsabilidades. 2.- Fomentar la calidad de los edificios. 3.- Fijar las garantías a los usuarios frente a los posibles daños. Estos tres fundamentos están intensamente relacionados, ya que, las obligaciones y responsabilidades de los agentes son la base de la constitución de las garantías a los usuarios, definidas mediante los requisitos básicos que deben satisfacer los edificios. Partiendo del análisis cualitativo y cuantitativo del grado de cumplimiento del objetivo de la nueva Ley, elaborado a través del estudio de sus tres pilares fundamentales, proponemos medidas tendentes a la plena entrada en vigor de la misma. Para ello se deberá desarrollar el Real Decreto previsto en la Disposición Adicional 2ª, una vez conseguido el grado de madurez de los sectores de la edificación y del seguro. En todo este proceso de estudio hemos podido apreciar que la objetiva identificación de los daños y en especial los que afectan la estabilidad del edificio, constituye una herramienta fundamental para la correcta atribución de responsabilidades a los agentes, basada en la aplicación de los tres grados de responsabilidad “ex lege” por daños materiales y sus plazos de prescripción surgidos del nuevo régimen impuesto por el art. 17 LOE Para avalar esta propuesta hemos analizado: 1.- El entorno económico, general y pormenorizado al sector de la edificación, en Europa y España durante el período comprendido entre los años 1990 y 2013, años previos y posteriores a la entrada en vigor de la Ley, dada la influencia de los ciclos de actividad producidos en la regulación del sector, las responsabilidades atribuidas a los agentes, el fomento de la calidad y las garantías ofrecidas a los adquirentes. 2.- Las diversas legislaciones sobre responsabilidades y garantías de los agentes de la edificación en los países de nuestro entorno económico. 3.- La gestación de la LOE, incidiendo en la evolución de los últimos borradores y su tramitación parlamentaria. 4.- El desarrollo doctrinal de la Transición desde el régimen de responsabilidades, fijado por el art. 1591 de Código Civil, y su Jurisprudencia, hacia el nuevo régimen de responsabilidades establecido por el art. 17 LOE. En esta tarea además de apreciar la asimilación, por parte de los Jueces y Magistrados, de los principios doctrinales de la LOE, hemos observado la labor de los peritos, de cuya experta identificación de las causas de los daños depende la justa y eficaz atribución de responsabilidades. 5 -. El grado de eficacia de la LOE a la vista de la estadística siniestral, de la que ya hay datos consolidados, tras la cancelación de casi 15.000 expedientes de reclamación a Arquitectos. 6 -. También hemos estudiado el grado de cumplimiento con el usuario y propietario de las garantías previstas en el art. 19 de la Ley y en la D.A. 1ª, los efectos reales alcanzados y las tareas pendientes por delante. Analizando la atribución de responsabilidades a los agentes de la edificación, dentro del primer pilar fundamental de la LOE, hemos estudiado las actuaciones de los peritos expertos y su incidencia en este objetivo, previa selección de casos de gran interés y dificultad. Fruto de ello se han formulado propuestas tendentes a la especialización de este colectivo, evitando conductas “irregulares” que tanto daño provocan a los agentes reclamados como a los propietarios afectados. Este daño es evidente pudiendo ocasionar condenas injustas, enriquecimientos ilícitos o bien falsas expectativas de satisfacción de daños mal dictaminados y costosas e ineficaces reparaciones. De cara a la consecución del pilar de la calidad de la edificación, mediante los requisitos básicos planteados por la LOE y desarrollados por el Código Técnico de la Edificación (Real Decreto 314/2006, de 17 de marzo), hemos procesado datos de expedientes de reclamaciones por daños que afectan a edificios ejecutados bajo el nuevo régimen LOE. Con esta base se han analizado las causas generadoras de las diversas lesiones y su frecuencia para que de este análisis puedan establecerse pautas de actuación para su prevención. Finalmente, tras demostrar que las garantías obligatorias impuestas por la LOE sólo abarcan un pequeño porcentaje de los posibles daños a la edificación, insistimos en la necesidad de la plena eficacia de la Ley mediante la aprobación de todas las garantías previstas y para todo tipo de edificaciones. En suma, se ha diseñado la tesis como una matriz abierta en la que podremos continuar incorporando datos de la evolución de la doctrina, la jurisprudencia y la estadística de los daños en la edificación. ABSTRACT The approval of Law 38/1999 on November 5, 1999, (Official Gazette BOE 266/1999 of 11.6.1999, p. 38925), was the culmination of a long period of over 20 years of gestation for which deep agreements were needed between all stakeholders affected. Although several parliamentary groups denounced its incomplete approval, regarding mandatory guarantees to the purchaser, its enactment caused general satisfaction among most of the the building agents. This assessment remains after fourteen years since its partial enactment. Its essential purpose, “to regulate the building process”, is based on 3 pillars: 1.- To complete the legal configuration of the agents involved in it, setting their obligations in order to establish their responsibilities. 2.- To promote the buildings quality. 3.- To specify users´guarantees against possible buildings damage. These three issues are strongly related, since the obligations and responsibilities of the actors are the basis of the users’guarantees constitution, defined by the basic performance required by buildings. Based on the qualitative and quantitative analysis of the fulfillment of the new law’s objectives, made by monitoring the three pillars, we propose measures to the full enactment of this Directive, by the development of the Royal Decree, provided in its Second Additional Provision, once maturity in the sectors of the building and insurance is achieved. Throughout this process of study we have seen that the skill identification of damage, particularly those affecting the stability of the building, is an essential tool for the proper allocation of responsibilities of the new regime installed by the art. 17 LOE, based on the application of the three degrees of responsibility "ex lege" for property damage and limitation periods. To support this proposal, we have analyzed: 1.- The evolution of the building sector in Europe and Spain during the years before and after the enactment of the Law, due to the influence of cycles of activity produced in industry regulation, the responsibilities attributed to agents, promotion of the quality and the assurances given to acquirers. 2.- The scope of various laws on liability and building agents warranties in the countries of our economic environment. 3.- The long period of LOE generation, focusing on the developments in recent drafts and parliamentary procedure. 4.- The doctrinal development in the Transition from the regime of responsibilities, set by art. 1591 of the Civil Code, and its Jurisprudence, to the new liability regime established by art. 17 LOE. In this task, while we have noted assimilation by the Judges and Magistrates of the doctrinal principles of the LOE, we have also analyzed the work of experts, whose skilled identification of the damage causes helps the fair and efficient allocation of responsibilities. 5 - The effectiveness of the LOE based on knowledge of the siniestral statistics, which are already consolidated data, after the cancellation of nearly 15,000 claims to Architects. 6.- We have also studied the degree of compliance with the user and owner guarantees, established in art. 19 and the D.A. 1th of the LOE, exposing the real effects achieved and the pending tasks ahead. Analyzing the allocation of the building agents´ responsibilities, within the first cornerstone of the LOE, we have studied the expert witnesses actions and their impact on this duty, selecting cases of great interest and difficulty in this aim. The result of this enterprise has been to propose the specialization of this group, avoiding "irregular" behaviors that create as much damage as the agents claimed to affected owners. This damage is evident and can cause wrong convictions, illicit enrichment, false expectations and inefficient and costly damage repairs. In order to achieve the pillar of building quality through the basic requirements set by the LOE and developed by the Technical Building Code (Royal Decree 314/ 2006 of 17 March), we have analyzed records of damage claims involving buildings executed under the new regime LOE. On this basis we have analyzed the root causes of various damages and their frequency, from these data it will be easy to propose lines of action for prevention. Finally, after demonstrating that mandatory warranties imposed by LOE cover only a small percentage of the potential building damage, we emphasize the need for the full effectiveness of the Law by the obligation all the guarantees provided in the art. 19 LOE, and for all types of buildings. In conclusion, this thesis is designed as an open matrix in which we will continue including data on the evolution of the doctrine, jurisprudence and the statistics of the damage to the building.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper presents shake-table tests conducted on a two-fifths-scale reinforced concrete frame representing a conventional construction design under current building code provisions in the Mediterranean area. The structure was subjected to a sequence of dynamic tests including free vibrations and four seismic simulations in which a historical ground motion record was scaled to levels of increasing intensity until collapse. Each seismic simulation was associated with a different level of seismic hazard, representing very frequent, frequent, rare and very rare earthquakes. The structure remained basically undamaged and within the inter-story drift limits of the "immediate occupancy" performance level for the very frequent and frequent earthquakes. For the rare earthquake, the specimen sustained significant damage with chord rotations of up to 28% of its ultimate capacity and approached the upper bound limit of inter-story drift associated with "life safety". The specimen collapsed at the beginning of the "very rare" seismic simulation. Besides summarizing the experimental program, this paper evaluates the damage quantitatively at the global and local levels in terms of chord rotation and other damage indexes, together with the energy dissipation demands for each level of seismic hazard. Further, the ratios of column-to-beam moment capacity recommended by Eurocode 8 and ACI-318 to guarantee the formation of a strong column-weak beam mechanism are examined.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Brick facades are a construction type, strongly linked to local construction characteristics and methods. In Spain, particularly in Castilla, the facades have been built since the '80s with Castilian half foot (11.5 cm), resting on the edge of slabs. The design of these facades, to horizontal loads from wind, depending on the codes used, can lead to completely different valid solutions. Applying same loads, the facades studied with current European standard (Eurocode 6), have a maximum length of 7.1 m between supports, while the Spanish code, Technical Building Code - Structural Safety Masonry, (CTE SE-F), 8.4 m can be achieved. This represents an increase of flexural strength, depending on the calculation model used, which can reach until 8 times. This is due to the difference of the calculation method and the structural model in one and another standard, depending on if this facade is analyzed as a vertical or horizontal beam or by formation of a vertical or horizontal archh. This paper analyzes the constructive solution of the brick facades that results from applying Spanish or European standards and how it affects the model applied in the safety of the resulting facade.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

El riesgo de caída por deslizamiento en los edificios es un riesgo muy importante ya que supone numerosas muertes, perdida de días laborales y secuelas, así como importantes costes económicos. Se trata de accidentes difíciles de predecir debido al número de factores que intervienen para que se produzcan, muchos de los cuales son difícilmente controlables, como el calzado del usuario o su comportamiento. Para evitar un resbalón es necesario que la fricción del conjunto pavimento/calzado/contaminante supere el coeficiente de fricción requerido para la estabilidad y que depende de la forma de caminar, la longitud del paso, etc. Por ello, es necesario medir la contribución del pavimento al riesgo de deslizamiento y limitarla adecuadamente. A lo largo de la historia reciente se han diseñado y desarrollado multitud de aparatos con la intención de medir esta contribución en la forma de coeficientes de fricción —dinámicos, estáticos, de transición— sin llegar a un acuerdo sobre cuál es el método más apropiado. La reglamentación española de edificación, que ha sufrido un importante cambio recientemente con la adopción de un nuevo código basado en prestaciones, ha sido innovadora en este campo introduciendo por primera vez una medida contrastable de la contribución del pavimento al riesgo de deslizamiento mediante el ensayo del péndulo de fricción en húmedo. Sin embargo, el desacuerdo a nivel europeo sobre un ensayo único y las limitaciones en las normas de ensayo existentes derivadas de esta falta de consenso, han sido la causa de que la solución aportada por el Código Técnico de la Edificación (CTE) se cimentara en normas que no contemplaban todas las modalidades de ensayo. Esto ha generado algunos problemas de aplicación que han afectado fundamentalmente a los pavimentos pulidos, que han visto prácticamente vetada su utilización en los edificios incluso en las zonas donde, por no existir presencia de agua, el riesgo es menor. El objetivo de esta tesis es analizar estos problemas de aplicación, ligados al ensayo del péndulo de fricción, y tratar de resolverlos optimizando el procedimiento de ensayo empleado, modificando sus condiciones, para representar de forma mucho más adecuada el riesgo que se pretende limitar. Para ello se ha estudiado de forma exhaustiva la literatura científica y las normas y reglamentaciones, tanto españolas como extranjeras. Se han detectado los posibles problemas que podría plantear la introducción del ensayo del péndulo de fricción en seco y se ha diseñado una campaña de ensayos, tanto de coeficiente de fricción con el péndulo, como de la rugosidad superficial, para confirmarlos o desecharlos. El análisis de los resultados de la campaña de ensayos ha permitido validar la modalidad de ensayo planteada y proponer una medida complementaria de la rugosidad superficial que resulte útil para facilitar la evaluación de este riesgo no poco importante. Los resultados de esta tesis han permitido desarrollar una modificación del CTE de próxima aparición y un documento de apoyo que ya la adelanta, y con ello, resolver el problema de aplicación del CTE a los pavimentos pulidos. ABSTRACT Slipping accidents in building environments are a serious problem involving numerous fatal accidents, loss of work days, incapacity and great costs. Prediction of such accidents is difficult due to the number of factors involved, many of which are not controllable, like footwear or users behavior. To prevent a slip the coefficient of friction provided by the combination floor-footwear-contaminant must be greater than the required coefficient of friction for stability, that depends on the step length and the walking speed among other factors. It is then necessary to measure the contribution of the floor to the slipping risk so it can be limited to an adequate extent. In the recent history many apparatuses have been developed in order to measure this contribution in the form of friction coefficients —dynamic, static or even transition COFs— but none of them seems to be internationally accepted as sufficiently valid. The Spanish Building Code, which has recently undergone a big change to a performance based code, has been innovative in this area, introducing for the first time a measurement of this contribution by means of the friction pendulum test. However, due to the European disagreement about an unique test for slip resistance, and to the limitations of the European standards derived from it, the Spanish Building Code relies on standards that do not take into account all possible methods. As a consequence, smooth floors have been seriously affected and cannot be installed in almost any place, not even in dry areas where the risk of slipping is much lower. The aim of this research is to analyze these problems associated with the pendulum test and resolve them proposing some changes to the test conditions in order to represent in a proper manner the real risk that is to be considered: the slip in dry conditions. Relevant scientific literature has been studied as well as Spanish and foreign codes and standards. Potential problems of the pendulum test in dry conditions have been detected and an experiment has been designed to confirm or discard them, testing both friction coefficient and surface roughness. The results of the experiment have permitted to validate the pendulum test in dry conditions and to suggest a complementary measurement of the surface roughness to help evaluate the slip resistance of a floor. These results have also permitted to develop an amendment to the building code that will appear soon. In the meanwhile it has been included in a support document issued by the administration to resolve this urgent problem.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Over the last decade the intense activity of the building sector has generated large quantities of construction and demolition waste (CDW). In particular, in Europe around 890 million tons of CDW is generated every year; however, only 50% of them are recycled. In Spain, over the last years 40 millions of tons of construction and demolition waste have been generated. On the other hand, since the implementation of the Technical Building Code regulation the use of mineral wools as building insulation materials has become a widespread solution in both rehabilitation and new construction works, and because of that, this kind of insulation waste is increasing. This research analyzes the potential of a new composite (gypsum and fiber waste) including several mineral wools waste into a plaster matrix. For this purpose, an experimental plan, characterizing the physical and mechanical behaviour as well as the Shore C hardness of the new composite, was elaborated fulfilling UNE Standards.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

En la actualidad, el crecimiento de la población urbana, el incremento de la demanda energética junto al desarrollo tecnológico impulsado en los últimos veinte años han originado un estudio y replanteamiento de los sistemas constructivos empleados. Como consecuencia se han establecido nuevos marcos normativos, marcando nuevos objetivos de confort y de demanda energética. En España, el Código Técnico de la Edificación (aprobado en el Real Decreto 314/2006 de 17 de Marzo) es el marco normativo que establece las exigencias que se deben cumplir al proyectar construir, usar, mantener y conservar los edificios, incluidas sus instalaciones, con el fin de asegurar la calidad, seguridad y salud del usuario, respetando en todo momento su entorno. Para asegurar el cumplimiento de las exigencias del Código Técnico de la Edificación (CTE), se han elaborado diferentes Documentos Básicos (DB). Entre ellos están los documentos básicos DB HR-Protección frente al ruido y el DB HS-Salubridad. En el DB HS 3 Calidad del aire interior, se establecen las condiciones que deben de adoptarse para que los recintos de los edificios se puedan ventilar adecuadamente, eliminando los contaminantes que se produzcan de forma habitual durante un uso normal de los edificios, de forma que se aporte un caudal suficiente de aire exterior y se garantice la extracción y expulsión del aire viciado por los contaminantes. En el apartado 3.1, Condiciones generales de los sistemas de ventilación, se indica que las viviendas deben disponer de un sistema general de ventilación donde el aire debe circular desde los locales secos a los húmedos. Para ello los comedores, los dormitorios y las salas de estar deben de disponer de aberturas de admisión, pudiéndose resolver esta cuestión técnica con diversas soluciones. El DB HR Protección frente al ruido del CTE, establece unos valores del aislamiento acústico a ruido aéreo, entre un recinto protegido y el exterior, en función del uso del edificio y del nivel sonoro continuo equivalente día, Ld de la zona donde se ubique el edificio. El hacer compatibles el cumplimiento de las exigencias de los dos Documentos Básicos anteriormente citados, origina algunas dificultades en los proyectos de edificación actuales. Los proyectistas tienen que recurrir en la mayoría de los casos a nuevos sistemas constructivos o duplicaciones de soluciones existentes, evitando la manipulación de los elementos de regulación de entrada de aire en las viviendas. El objetivo fundamental de la Tesis presentada es el estudio de los efectos que producen la colocación de sistemas de aireación permanente en el aislamiento acústico a ruido aéreo de las ventanas compactas. Se comprueba la influencia de cada uno de los componentes de la ventana compacta: perfiles, unidades de vidrio, sistema de apertura, cajón de persiana, persiana, aireadores, etc. en el aislamiento a ruido aéreo del sistema completo. Los ensayos acústicos se han realizado mediante dos métodos: conforme a la norma UNE-EN ISO 10140-2:2011 Medición en laboratorio del aislamiento acústico al ruido aéreo de los elementos de construcción y mediante intensimetría acústica acorde a la norma UNE-EN ISO 15186-1:2004 Medición del aislamiento acústico en los edificios y de los elementos de construcción utilizando intensidad sonora. Los resultados obtenidos podrán ser de gran utilidad para todos los profesionales que intervienen en el proceso edificatorio: arquitectos, ingenieros, instaladores, promotores, fabricantes de productos, etc., tanto en la obra nueva como en la rehabilitación. En un futuro, podrían incorporarse a los Catálogos y Documentos de Aplicación del CTE, así como a los nuevos programas informáticos de diseño y aislamiento acústico. Con el conocimiento adquirido y su aplicación, se contribuirá a la mejora de la calidad de una edificación más sostenible y eficiente. Se incrementará la productividad y la competitividad de los fabricantes de materiales y sistemas constructivos, aumentando el grado de satisfacción del usuario final con el consiguiente aumento de la calidad de vida de los ciudadanos. También se ampliará el conocimiento técnico de este tipo de sistemas y la compatibilidad entre las distintas exigencias marcadas por la normativa. ABSTRACT At present, the urban population growth, the increase of energy demand and the technological development in the last twenty years have led to a rethinking of the used building systems. As a result, new regulatory frameworks have been established, setting new goals of comfort and energy demand. In Spain, the Building Code, Código Técnico de la Edificación (CTE) (RD 314/2006 of March 17th) is the regulatory framework that establishes the requirements to be met by projecting, building, using, maintaining and preserving buildings, including its facilities in order to ensure the quality, safety and health of the user, always respecting the environment. To ensure compliance with the requirements of the CTE, different technical requirements Documentos básicos (DB) have been developed. Among them, are the DB-HR-Protection against noise and DB-HS-Health. In the DB-HS- part3, Indoor Air Quality, are set the conditions needed to be taken into consideration so that the building enclosures can be adequately ventilated, eliminating pollutants that occur regularly during normal use of the buildings, so that a sufficient airflow of outdoor is supplied and a removal and extraction of stale air pollutants is guaranteed. In section 3.1, General Terms of ventilation systems, is indicated that dwellings must have a general ventilation system where air can circulate from dry to wet enclosures. For this, dining rooms, bedrooms and living rooms should have air intake, being able to resolve this technical issue with various solutions. The DB-HR Protection against noise, provides sound insulation values of airborne sound transmission between a protected room and the outside, depending on the use of the building and the equivalent continuous sound level day, Ld, in the area where the building is located. Satisfying the requirements of the two requirements mentioned above causes some difficulties in current building project. Designers have to rely in most cases, to new construction elements or duplicate existing solutions, avoiding the manipulation of the air intakes elements. The main objective of this Thesis is the study of the effects of permanent intakes systems in the acoustic insulation against airborne noise transmission in compact windows. The influence of each of the components of the compact window is determined: frames, glass units, opening systems, shutter box, trickle vents, etc. in the airborne sound insulation of the entire system. The acoustic survey were performed using two methods: UNE-EN ISO 10140-2: 2011 Laboratory measurements of sound insulation of building elements and UNE-EN ISO 15186-1:2004 Measurement of sound insulation in buildings and of building elements using sound intensity. The obtained results may be useful for all professionals involved in the building process: architects, engineers, installers, developers, manufacturers, etc. in the new construction developments and in rehabilitation. In the future, it could be added to building catalogues and applications of the Spanish Building Code, as well as to the new design and sound insulation software. With the acquired knowledge and its application, there will be a contribution to improve the quality of a more sustainable and efficient construction. Productivity and competitiveness of manufacturers of building materials and components will improve, increasing the degree of satisfaction of the final user with a consequent increase in the quality of life of citizens. Technical knowledge of such systems and compatibility between the various requirements set by the legislation will also expand.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

La edificación residencial existente en España y en Europa se encuentra abocada a una rehabilitación profunda para cumplir los objetivos marcados en la estrategia europea para el año 2050. Estos, para el sector de la edificación, se proponen una reducción del 90% de emisiones de gases de efecto invernadero (GEI) respecto a niveles del año 1990. Este plan a largo plazo establece hitos intermedios de control, con objetivos parciales para el año 2020 y 2030. El objetivo último es aprovechar el potencial de reducción de demanda energética del sector de la edificación, del cual la edificación residencial supone el 85% en España. Dentro de estos requerimientos, de reducción de demanda energética en la edificación, la ventilación en la edificación residencial se convierte en uno de los retos a resolver por su vinculación directa a la salud y el confort de los ocupantes de la misma, y al mismo tiempo su relación proporcional con la demanda energética que presenta el edificio asociada al acondicionamiento térmico. Gran parte de las pérdidas térmicas de la edificación residencial se producen por el aire de renovación y la infiltración de aire a través de la envolvente. La directiva europea de eficiencia energética de la edificación (EPBD), que establece las directrices necesarias para alcanzar los objetivos de este sector en cuanto a emisiones de CO2 y gases de efecto invernadero (GEI), contempla la ventilación con aire limpio como un requisito fundamental a tener en cuenta de cara a las nuevas construcciones y a la rehabilitación energética de los edificios existentes. El síndrome del edificio enfermo, un conjunto de molestias y síntomas asociados a la baja calidad del aire de edificios no residenciales que surgió a raíz de la crisis del petróleo de 1973, tuvo su origen en una ventilación deficiente y una renovación del aire interior insuficiente de estos edificios, producto del intento de ahorro en la factura energética. Teniendo en cuenta que, de media, pasamos un 58% de nuestro tiempo en las viviendas, es fundamental cuidar la calidad del aire interior y no empeorarla aplicando medidas de “eficiencia energética” con efectos no esperados. Para conseguir esto es fundamental conocer en profundidad cómo se produce la ventilación en la edificación en bloque en España en sus aspectos de calidad del aire interior y demanda energética asociada a la ventilación. El objetivo de esta tesis es establecer una metodología de caracterización y de optimización de las necesidades de ventilación para los espacios residenciales existentes en España que aúne el doble objetivo de garantizar la calidad ambiental y reducir la demanda energética de los mismos. La caracterización del parque edificatorio residencial español en cuanto a ventilación es concluyente: La vivienda en España se distribuye principalmente en tres periodos en los que se encuentran más del 80% del total de las viviendas construidas. El periodo anterior a las normas básicas de la edificación (NBE), de 1960 a 1980, el periodo desde 1980 al año 2005, con el mayor número total de viviendas construidas, guiado por la NTE ISV 75, y el periodo correspondiente a la edificación construida a partir del Código Técnico de la Edificación, en 2006, cuyo documento básico de condiciones de salubridad (DB HS3) es la primera norma de obligado cumplimiento en diseño y dimensionamiento de ventilación residencial en España. La selección de un modelo de bloque de viviendas de referencia, un valor medio y representativo, seleccionado de entre estos periodos, pero con cualidades que se extienden más allá de uno de ellos, nos permite realizar un intensivo análisis comparativo de las condiciones de calidad de aire interior y la demanda energética del mismo, aplicando las distintas configuraciones que presenta la ventilación en viviendas dependiendo del escenario o época constructiva (o normativa) en que esta fuera construida. Este análisis se lleva a cabo apoyándose en un doble enfoque: el modelado numérico de simulaciones y el análisis de datos experimentales, para comprobar y afinar los modelos y observar la situación real de las viviendas en estos dos aspectos. Gracias a las conclusiones del análisis previo, se define una estrategia de optimización de la ventilación basada fundamentalmente en dos medidas: 1) La introducción de un sistema de extracción mecánica y recuperación de calor que permita reducir la demanda energética debida a la renovación del aire y a la vez diluir los contaminantes interiores más eficazmente para mejorar, de esta forma, la calidad del ambiente interior. 2) La racionalización del horario de utilización de estos sistemas, no malgastando la energía en periodos de no ocupación, permitiendo una leve ventilación de fondo, debida a la infiltración, que no incida en pérdidas energéticas cuantiosas. A esta optimización, además de aplicar la metodología de análisis previo, en cuanto a demanda energética y calidad del aire, se aplica una valoración económica integradora y comparativa basada en el reglamento delegado EU244/2012 de coste óptimo (Cost Optimal Methodology). Los resultados principales de esta tesis son: • Un diagnóstico de la calidad del aire interior de la edificación residencial en España y su demanda energética asociada, imprescindible para lograr una rehabilitación energética profunda garantizando la calidad del aire interior. • Un indicador de la relación directa entre calidad de aire y demanda energética, para evaluar la adecuación de los sistemas de ventilación, respecto de las nuevas normativas de eficiencia energética y ventilación. • Una estrategia de optimización, que ofrece una alternativa de intervención, y la aplicación de un método de valoración que permite evaluar la amortización comparada de la instalación de los sistemas. ABSTRACT The housing building stock already built in Spain and Europe faces a deep renovation in the present and near future to accomplish with the objectives agreed in the European strategy for 2050. These objectives, for the building sector, are set in a 90% of Green House Gases (GHG) reduction compared to levels in 1990. This long‐term plan has set milestones to control the correct advance of achievement in 2020 and 2030. The main objective is to take advantage of the great potential to reduce energy demand from the building sector, in which housing represents 85% share in Spain. Among this reduction on building energy demand requirements, ventilation of dwellings becomes one of the challenges to solve as it’s directly connected to the indoor air quality (IAQ) and comfort conditions for the users, as well as proportional to the building energy demand on thermal conditioning. A big share of thermal losses in housing is caused by air renovation and infiltration through the envelope leaks. The European Directive on Building energy performance (EPBD), establishes the roots needed to reach the building sector objectives in terms of CO2 and GHG emissions. This directive sets the ventilation and renovation with clean air of the new and existing buildings as a fundamental requirement. The Sick Building Syndrome (SBS), an aggregation of symptoms and annoys associated to low air quality in non residential buildings, appeared as common after the 1973 oil crisis. It is originated in defective ventilation systems and deficient air renovation rates, as a consequence of trying to lower the energy bill. Accounting that we spend 58% of our time in dwellings, it becomes crucial to look after the indoor air quality and focus in not worsening it by applying “energy efficient” measures, with not expected side effects. To do so, it is primary to research in deep how the ventilation takes place in the housing blocks in Spain, in the aspects related to IAQ and ventilation energy demand. This thesis main objective is to establish a characterization and optimization methodology regarding the ventilation needs for existing housing in Spain, considering the twofold objective of guaranteeing the air quality as reducing the energy demand. The characterization of the existing housing building stock in Spain regarding ventilation is conclusive. More of 80% of the housing stock is distributed in 3 main periods: before the implementation of the firsts regulations on building comfort conditions (Normas Básicas de la Edificación), from 1960 to 1980; the period after the first recommendations on ventilation (NTE ISV 75) for housing were set, around 1980 until 2005 and; the period corresponding to the housing built after the existing mandatory regulation in terms of indoor sanity conditions and ventilation (Spanish Building Code, DB HS3) was set, in 2006. Selecting a representative blueprint of a housing block in Spain, which has medium characteristics not just within the 3 periods mention, but which qualities extent beyond the 3 of them, allows the next step, analyzing. This comparative and intense analyzing phase is focused on the air indoor conditions and the related energy demand, applying different configurations to the ventilation systems according to the different constructive or regulation period in which the building is built. This analysis is also twofold: 1) Numerical modeling with computer simulations and 2) experimental data collection from existing housing in real conditions to check and refine the models to be tested. Thanks to the analyzing phase conclusions, an optimization strategy on the ventilation of the housing stock is set, based on two actions to take: 1) To introduce a mechanical exhaust and intake ventilation system with heat recovery that allows reducing energy demand, as improves the capacity of the system to dilute the pollutant load. This way, the environmental quality is improved. 2) To optimize the schedule of the system use, avoids waste of energy in no occupancy periods, relying ventilation during this time in a light infiltration ventilation, intended not to become large and not causing extra energy losses. Apart from applying the previous analyzing methodology to the optimization strategy, regarding energy demand and air quality, a ROI valorization is performed, based on the cost optimal methodology (delegated regulation EU244/2012). The main results from the thesis are: • To obtain a through diagnose regarding air quality and energy demand for the existing housing stock in Spain, unavoidable to reach a energy deep retrofitting scheme with no air quality worsening. • To obtain a marker to relate air quality and energy demand and evaluate adequateness of ventilation systems, for the new regulations to come. • To establish an optimization strategy to improve both air quality and energy demand, applying a compared valorization methodology to obtain the Return On Investment (ROI).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Esta investigación aborda el estudio de la influencia de las uniones en el aislamiento acústico a ruido aéreo en los edificios y el análisis de las transmisiones indirectas producidas en particiones de dos hojas de ladrillo cerámico sobre bandas elásticas. La transmisión de ruido entre dos recintos separados por una partición se produce por dos vías: La vía directa a través del elemento que separa los dos recintos y la vía indirecta, a través de los elementos de flanco, como forjados, particiones, fachadas, etc. que conectados a dicho elemento de separación, vibran en presencia del campo acústico transmitiendo sus vibraciones al recinto receptor. Si las transmisiones indirectas son dominantes, el aislamiento acústico “in situ” puede ser menor que el esperado. El parámetro que expresa la atenuación acústica en las uniones es el índice de reducción vibracional en la unión o Kij. Éste parámetro se utiliza en los métodos de cálculo del aislamiento acústico a ruido aéreo, que permiten la justificación del cumplimiento de la normativa actual, el Documento Básico DB HR Protección frente al ruido del CTE. La determinación de los índices Kij de las uniones es una cuestión que debe abordarse de forma experimental. Existen diferentes expresiones empíricas obtenidas en varios laboratorios europeos que permiten el cálculo del índice Kij, pero no se han validado con ensayos realizados en soluciones habituales en la construcción española, como las estudiadas en este trabajo. El objetivo de este trabajo es la medida, análisis y cuantificación de las transmisiones indirectas producidas en las uniones de elementos de dos hojas de fábrica de ladrillo cerámico. Se ha recurrido a una campaña de ensayos en la que se reproducían las condiciones de un edificio real y se ha medido el aislamiento acústico a ruido aéreo y los índices Kij de diferentes configuraciones de uniones. Del análisis de los resultados, se demuestra que el aislamiento acústico a ruido aéreo depende de las uniones, pudiéndose obtener mejoras significativas al variar la forma de unión entre los elementos constructivos. Las mejoras de aislamiento acústico están relacionadas con un buen diseño de las uniones y con valores elevados del índice Kij. Este trabajo aporta valores experimentales de Kij para soluciones de fábrica de ladrillo y pone en discusión los valores teóricos que actualmente aparecen en la normativa vigente. ABSTRACT This research work deals with the effects of junction construction details on airborne sound insulation in buildings and the analysis of flanking transmissions across double ceramic brick walls with elastic interlayers. The sound transmission between two adjacent rooms comprises two paths: the direct path, caused by the incident sound on a separating wall, and the indirect path, through flanking elements connected to the separating wall, such as floors, internal walls, ceilings, etc. Flanking elements vibrate when excited in the sound field, thus transferring sound via structure borne to the receiving room. Dominant flanking transmissions can decrease the field sound insulation performance of the building. The vibration reduction index, Kij. expresses the acoustic attenuation of construction joints. This is an input parameter in the calculation models designed to estimate the airborne sound insulation between adjoining rooms in buildings. These models are used to comply with the acoustic requirements set by Basic Document DB HR Protection against noise included in the Spanish Building Code. The characterization of Kij. must be addressed experimentally by means of measurements. The available empirical Kij. formulae were developed in different European laboratories, but they have not been validated with standard tests performed on common Spanish walls, such as those studied in this work. The aim of this work is the measurement, analysis and quantification of indirect transmissions though joints of double ceramic brick walls. Airborne sound insulation tests and Kij measurements were performed in a laboratory which emulated the conditions of a real building. These tests were performed in different partitions whose joints were modified. It follows from the analysis of the results that airborne sound insulation depends strongly on the design of joints. Sound insulation improves when the joints between construction elements are modified to eliminate acoustic bridges. The increase in sound insulation corresponds to best practice design of joints and to high Kij values. This research work provides experimental Kij data of double ceramic brick walls and the results put in discussion the theoretical values set in the current Standards.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Evacuation route planning is a fundamental task for building engineering projects. Safety regulations are established so that all occupants are driven on time out of a building to a secure place when faced with an emergency situation. As an example, Spanish building code requires the planning of evacuation routes on large and, usually, public buildings. Engineers often plan these routes on single building projects, repeatedly assigning clusters of rooms to each emergency exit in a trial-and-error process. But problems may arise for a building complex where distribution and use changes make visual analysis cumbersome and sometimes unfeasible. This problem could be solved by using well-known spatial analysis techniques, implemented as a specialized software able to partially emulate engineer reasoning. In this paper we propose and test an easily reproducible methodology that makes use of free and open source software components for solving a case study. We ran a complete test on a building floor at the University of Alicante (Spain). This institution offers a web service (WFS) that allows retrieval of 2D geometries from any building within its campus. We demonstrate how geospatial technologies and computational geometry algorithms can be used for automating the creation and optimization of evacuation routes. In our case study, the engineers’ task is to verify that the load capacity of each emergency exit does not exceed the standards specified by Spain’s current regulations. Using Dijkstra’s algorithm, we obtain the shortest paths from every room to the most appropriate emergency exit. Once these paths are calculated, engineers can run simulations and validate, based on path statistics, different cluster configurations. Techniques and tools applied in this research would be helpful in the design and risk management phases of any complex building project.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

"1962 Edition".

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This study on risk and disaster management capacities of four Caribbean countries: Barbados, the Dominican Republic, Jamaica, and Trinidad and Tobago, examines three main dimensions: 1) the impact of natural disasters from 1900 to 2010 (number of events, number of people killed, total number affected, and damage in US$); 2) institutional assessments of disaster risk management disparity; and 3) the 2010 Inter-American Bank for Development (IADB) Disaster Risk and Risk Management indicators for the countries under study. The results show high consistency among the different sources examined, pointing out the need to extend the IADB measurements to the rest of the Caribbean countries. Indexes and indicators constitute a comparison measure vis-à-vis existing benchmarks in order to anticipate a capacity to deal with adverse events and their consequences; however, the indexes and indicators could only be tested against the occurrence of a real event. Therefore, the need exists to establish a sustainable and comprehensive evaluation system after important disasters to assess a country‘s performance, verify the indicators, and gain feedback on measurement systems and methodologies. There is diversity in emergency and preparedness for disasters in the four countries under study. The nature of the event (hurricanes, earthquakes, floods, and seismic activity), especially its frequency and the intensity of the damage experienced, is related to how each has designed its risk and disaster management policies and programs to face natural disasters. Vulnerabilities to disaster risks have been increasing, among other factors, because of uncontrolled urbanization, demographic density and poverty increase, social and economic marginalization, and lack of building code enforcement. The four countries under study have shown improvements in risk management capabilities, yet they are far from being completed prepared. Barbados‘ risk management performance is superior, in comparison, to the majority of the countries of the region. However, is still far in achieving high performance levels and sustainability in risk management, primarily when it has the highest gap between potential macroeconomic and financial losses and the ability to face them. The Dominican Republic has shown steady risk performance up to 2008, but two remaining areas for improvement are hazard monitoring and early warning systems. Jamaica has made uneven advances between 1990 and 2008, requiring significant improvements to achieve high performance levels and sustainability in risk management, as well as macroeconomic mitigation infrastructure. Trinidad and Tobago has the lowest risk management score of the 15 countries in the Latin American and Caribbean region as assessed by the IADB study in 2010, yet it has experienced an important vulnerability reduction. In sum, the results confirmed the high disaster risk management disparity in the Caribbean region.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This study on risk and disaster management capacities of four Caribbean countries: Barbados, the Dominican Republic, Jamaica, and Trinidad and Tobago, examines three main dimensions: 1) the impact of natural disasters from 1900 to 2010 (number of events, number of people killed, total number affected, and damage in US$); 2) institutional assessments of disaster risk management disparity; and 3) the 2010 Inter-American Bank for Development (IADB) Disaster Risk and Risk Management indicators for the countries under study. The results show high consistency among the different sources examined, pointing out the need to extend the IADB measurements to the rest of the Caribbean countries. Indexes and indicators constitute a comparison measure vis-à-vis existing benchmarks in order to anticipate a capacity to deal with adverse events and their consequences; however, the indexes and indicators could only be tested against the occurrence of a real event. Therefore, the need exists to establish a sustainable and comprehensive evaluation system after important disasters to assess a country’s performance, verify the indicators, and gain feedback on measurement systems and methodologies. There is diversity in emergency and preparedness for disasters in the four countries under study. The nature of the event (hurricanes, earthquakes, floods, and seismic activity), especially its frequency and the intensity of the damage experienced, is related to how each has designed its risk and disaster management policies and programs to face natural disasters. Vulnerabilities to disaster risks have been increasing, among other factors, because of uncontrolled urbanization, demographic density and poverty increase, social and economic marginalization, and lack of building code enforcement. The four countries under study have shown improvements in risk management capabilities, yet they are far from being completed prepared. Barbados’ risk management performance is superior, in comparison, to the majority of the countries of the region. However, is still far in achieving high performance levels and sustainability in risk management, primarily when it has the highest gap between potential macroeconomic and financial losses and the ability to face them. The Dominican Republic has shown steady risk performance up to 2008, but two remaining areas for improvement are hazard monitoring and early warning systems. Jamaica has made uneven advances between 1990 and 2008, requiring significant improvements to achieve high performance levels and sustainability in risk management, as well as macroeconomic mitigation infrastructure. Trinidad and Tobago has the lowest risk management score of the 15 countries in the Latin American and Caribbean region as assessed by the IADB study in 2010, yet it has experienced an important vulnerability reduction. In sum, the results confirmed the high disaster risk management disparity in the Caribbean region.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

With the entry into force of the latest Italian Building Code (NTC 2008, 2018), innovative criteria were provided, especially for what concerns the seismic verifications of large infrastructures. In particular, for buildings considered as strategic, such as large dams, a seismotectonic study of the site was declared necessary, which involves a re-assessment of the basic seismic hazard. This PhD project fits into this context, being part of the seismic re-evaluation process of large dams launched on a national scale following the O.P.C.M. 3274/2003, D.L. 79/2004. A full seismotectonic study in the region of two large earth dams in Southern Italy was carried out. We identified and characterized the structures that could generate earthquakes in our study area, together with the definition of the local seismic history. This information was used for the reassessment of the basic seismic hazard, using probabilistic seismic hazard assessment approaches. In recent years, fault-based models for the seismic hazard assessment have been proposed all over the world as a new emerging methodology. For this reason, we decided to test the innovative SHERIFS approach on our study area. The occasion of the seismotectonic study gave also the opportunity to focus on the characteristics of the seismic stations that provided the data for the study itself. In the context of the work presented here, we focused on the 10 stations that had been active for the longest time and we carried out a geophysical characterization, the data of which merged into a more general study on the soil-structure interaction at seismic stations and on the ways in which it could affect the SHA. Lastly, an additional experimental study on the two dams and their associated minor structures is also presented, aimed at defining their main dynamic parameters, useful for subsequent dynamic structural and geotechnical studies.