850 resultados para Saline solutions


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The study of proton conductance across artificial membranes has revealed a surprisingly high permeability for H+, (Pnet H+). A high Pnet H+ is difficult to reconcile with the biological requirement for the maintenance of pH gradients across the plasma membranes of cells, organellar study was undertaken to examine the role played by cholesterol and phospholipid fatty acid side chain composition in determining how well a membrane will function as a barrier to acid. The effects of counter-ion movement on acidification rates were examined in order to interpret the data obtained from variations in membrane composition. In phosphate buffered saline solutions, vesicle membranes composed of unsaturated fatty acid phosphatidylcholines proved to be poorer barriers to acid than membranes composed of saturated fatty acids. The barrier properties of these membranes could be ranked in the following order: DPL, (palmitic) $>$ Egg PC, (mixed chains) $>$ DLL, (linoleic), with DPL being the most effective in maintaining a one pH unit gradient near neutrality. Cholesterol decreased acidification rates of membranes made from the unsaturated phosphatidylcholines Egg PC and DLL, but enhanced acidification rates in vesicle membranes composed of the saturated phospholipid DPL. The cholesterol and fatty acid side chain effects were mediated by changes in membrane fluidity, with more rigid bilayers forming better barriers to acid. Experimental evidence was obtained which confirmed the Pnet H+ is very high relative to the permeabilities of other ions. Counter-ion controlled acidification rates depended on the size and charge of the ion which was moving in order to maintain electroneutrality. The biological relevance of a high intrinsic Pnet H+ and the possible role of counter-ion controlled acidification were discussed. ^

Relevância:

60.00% 60.00%

Publicador:

Resumo:

El objetivo principal de este trabajo es profundizar en el conocimiento del fenómeno de la corrosión subpelicular inducida por contaminantes hidrosolubles en la intercara metal/pintura. La contaminación salina del substrato es una situación común en la práctica: la superficie metálica suele estar expuesta a atmósferas contaminadas antes de ser recubierta, limpieza previa del metal con abrasivos contaminados, etc. La eliminación total de estos contaminantes resulta muy difícil de conseguir incluso con las técnicas más sofisticadas de limpieza. Esta investigación se centra en la determinación del efecto de la naturaleza del contaminante y la naturaleza y espesor del recubrimiento en el proceso de corrosión subpelicular del acero. En la investigación se utilizaron dos barnices de naturaleza diferente: poliuretano y vinílico; y se aplicaron a tres espesores diferentes. Los contaminantes empleados en este trabajo fueron: NaCl, NH4C1, CaCl2, Na2S04, (NH4)2S04, NaN03, NH4N03, Ca(N03)2. Los ensayos se realizaron en una cámara de condensación de humedad permanente. Los tiempos de exposición fueron 100, 300 y 600 horas. La velocidad de corrosión se evaluó gravimétricamente, mediante la técnica de pérdida de peso. Se realizaron estudios de permeabilidad al oxígeno y al agua de películas libres de substrato, evaluación de la velocidad de corrosión de probetas sin pintar inmersas en soluciones salinas de los contaminantes seleccionados, conductividad de dichas soluciones salinas, solubilidad del oxígeno en las soluciones salinas, adherencia en seco y en húmedo a diferentes tiempos de exposición. Se aporta evidencia respecto al control ejercido en el proceso corrosivo por el oxígeno que permea a través de la película, mientras que la permeación de agua controla la pérdida de adherencia del recubrimiento. Ambas permeabilidades dependen de la naturaleza del recubrimiento y de su espesor. Se ha investigado la influencia de la naturaleza del contaminante en la intercara metal/pintura. La naturaleza del catión parece quedar enmascarada por el efecto definitivo del anión. La concentración salina ejerce asimismo un efecto importante en la corrosión subpelicular. ABSTRACT The main aim of this work is to study in depth the knowledge of underfilm corrosión induced by hydrosoluble contaminants at the metal/paint Ínterface. The saline contamination of the substrate is a common situation in practice: metallic surfaces use to be exposed to polluted atmospheres, previous cleaning of the metal with contaminated abrasives, etc. Total elimination of these contaminants is hard to obtain even with modern cleaning techniques. This research is focused in determining the effect of contaminant nature, coating nature and its thickness on the steel underfilm corrosión process. In this work we used two varnishes with different nature: polyurethane and vinyl; they were applied in three different thicknesses. The saline contaminants employed were: NaCl, NH4C1, CaCl2, Na2S04, (NH4)2S04, NaN03, NH4N03/ Ca(N03)2. The tests were carried out in a condensation humidity chamber. The period of exposure were 100, 300 and 600 hours. Corrosión rate was assessed by weight loss. Simultaneously, studies on oxygen and water permeability of free films, assessing on corrosión rate of uncoated samples immersed in saline solutions of the selected contaminants, conductivity of these solutions, oxygen solubility in saline solutions, wet and dry adhesión of the polyurethane varnish at different periods of exposure, were carried out. There is clear evidence about control on corrosión process of oxygen that passes through the coating, while the passing of water controls the loss of adhesión of the coating. Both, water and oxygen permeation, depend on the nature and thickness of the coating. It has been researched the inf luence of the nature of contaminant at the metal/paint interface. The nature of the catión seems to be "masked" by the definitive effect of the nature of anión. The saline concentration also exerts an important effect on underfilm corrosión.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We demonstrate an intrinsic biochemical concentration sensor based on a polymer optical fiber Bragg grating. The water content absorbed by the polymer fiber from a surrounding solution depends on the concentration of the solution because of the osmotic effect. The variation of water content in the fiber causes a change in the fiber dimensions and a variation in refractive index and, therefore, a shift in the Bragg wavelength. Saline solutions with concentration from 0% to 22% were used to demonstrate the sensing principle, resulting in a total wavelength shift of 0.9 nm, allowing high-resolution concentration measurements to be realized.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND Intravenous fluids are commonly prescribed in childhood. 0.9 % saline is the most-used fluid in pediatrics as resuscitation or maintenance solution. Experimental studies and observations in adults suggest that 0.9 % saline is a poor candidate for fluid resuscitation. Although anesthesiologists, intensive care specialists, perioperative physicians and nephrologists have been the most active in this debate, this issue deserves some physiopathological considerations also among pediatricians. RESULTS As compared with so-called "balanced" salt crystalloids such as lactated Ringer, administration of large volumes of 0.9 % saline has been associated with following deleterious effects: tendency to hyperchloremic metabolic acidosis (called dilution acidosis); acute kidney injury with reduced urine output and salt retention; damaged vascular permeability and stiffness, increase in proinflammatory mediators; detrimental effect on coagulation with tendency to blood loss; detrimental gastrointestinal perfusion and function; possible uneasiness at the bedside resulting in unnecessary administration of more fluids. Nevertheless, there is no firm evidence that these adverse effects are clinically relevant. CONCLUSIONS Intravenous fluid therapy is a medicine like insulin, chemotherapy or antibiotics. Prescribing fluids should fit the child's history and condition, consider the right dose at the right rate as well as the electrolyte levels and other laboratory variables. It is unlikely that a single type of fluid will be suitable for all pediatric patients. "Balanced" salt crystalloids, although more expensive, should be preferred for volume resuscitation, maintenance and perioperatively. Lactated Ringer appears unsuitable for patients at risk for brain edema and for those with overt or latent chloride-deficiency. Finally, in pediatrics there is a need for new fluids to be developed on the basis of a better understanding of the physiology and to be tested in well-designed trials.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The present study compared the accuracy of three electronic apex locators (EALs) - Elements Diagnostic®, Root ZX® and Apex DSP® - in the presence of different irrigating solutions (0.9% saline solution and 1% sodium hypochlorite). The electronic measurements were carried out by three examiners, using twenty extracted human permanent maxillary central incisors. A size 10 K file was introduced into the root canals until reaching the 0.0 mark, and was subsequently retracted to the 1.0 mark. The gold standard (GS) measurement was obtained by combining visual and radiographic methods, and was set 1 mm short of the apical foramen. Electronic length values closer to the GS (± 0.5 mm) were considered as accurate measures. Intraclass correlation coefficients (ICCs) were used to verify inter-examiner agreement. The comparison among the EALs was performed using the McNemar and Kruskal-Wallis tests (p < 0.05). The ICCs were generally high, ranging from 0.8859 to 0.9657. Similar results were observed for the percentage of electronic measurements closer to the GS obtained with the Elements Diagnostic® and the Root ZX® EALs (p > 0.05), independent of the irrigating solutions used. The measurements taken with these two EALs were more accurate than those taken with Apex DSP®, regardless of the irrigating solution used (p < 0.05). It was concluded that Elements Diagnostic® and Root ZX® apex locators are able to locate the cementum-dentine junction more precisely than Apex DSP®. The presence of irrigating solutions does not interfere with the performance of the EALs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Despite the increasing prevalence of salinity world-wide, the measurement of exchangeable cation concentrations in saline soils remains problematic. Two soil types (Mollisol and Vertisol) were equilibrated with a range of sodium adsorption ratio (SAR) solutions at various ionic strengths. The concentrations of exchangeable cations were then determined using several different types of methods, and the measured exchangeable cation concentrations compared to reference values. At low ionic strength (low salinity), the concentration of exchangeable cations can be accurately estimated from the total soil extractable cations. In saline soils, however, the presence of soluble salts in the soil solution precludes the use of this method. Leaching of the soil with a pre-wash solution (such as alcohol) was found to effectively remove the soluble salts from the soil, thus allowing the accurate measurement of the effective cation exchange capacity (ECEC). However, the dilution associated with this pre-washing increased the exchangeable Ca concentrations while simultaneously decreasing exchangeable Na. In contrast, when calculated as the difference between the total extractable cations and the soil solution cations, good correlations were found between the calculated exchangeable cation concentrations and the reference values for both Na (Mollisol: y=0.873x and Vertisol: y=0.960x) and Ca (Mollisol: y=0.901x and Vertisol: y=1.05x). Therefore, for soils with a soil solution ionic strength greater than 50 mM (electrical conductivity of 4 dS/m) (in which exchangeable cation concentrations are overestimated by the assumption they can be estimated as the total extractable cations), concentrations can be calculated as the difference between total extractable cations and soluble cations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The photodegradation of irinotecan (CPT-11), the semisynthetic derivative of the antitumor alkaloid 20(S)-camptothecin, has been investigated. The drug was exposed to laboratory light for up to 5 days in 0.9% saline solution (pH 8.5). Five significant photodegradation products were observed and a high-performance liquid chromatography (HPLC) assay was employed to isolate them from CPT-11 using gradient conditions. The structures were elucidated by nuclear magnetic resonance spectroscopy and tandem mass spectrometry and shown to be the result of extensive modifications of the lactone ring of CPT-11. Three of the compounds were found to belong to the mappicine group of alkaloids. In addition, the effect of light on the stability of CPT-11 in aqueous solutions and biological fluids was also assessed, Potassium phosphate buffers (0.05 M, pH 5.0-8.2) and saline, plasma, urine, and bile solutions containing 20 mu M CPT-11 were equilibrated in the dark for 24 h before being exposed to laboratory light for up to 171 h at ambient temperature. Four of the five identified photodegradation products were observed and quantitated by isocratic HPLC, using a different detection mode (fluorescence) than the one used for gradient elution, In general, CPT-11 was found to be unstable under neutral and alkaline conditions for all solutions investigated, with the exception of bile. We conclude that CPT-11 is photolabile and that care should be taken to protect samples, particularly those intended for the isolation and identification of novel metabolites of CPT-11.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective. The objective of this study was to evaluate the antibacterial efficacy of irrigating solutions and their combinations against Enterococcus faecalis. Study design. One hundred ten single-rooted human teeth were inoculated with E. faecalis and incubated for 21 days. Teeth were divided according to the irrigant: Group I (GI), 2.5% sodium hypochlorite solution (NaOCl); GII, 2.5% NaOCl + 10% citric acid; GIII, 2.5% NaOCl + apple cider vinegar; GIV, apple cider vinegar; GV, 2% chlorhexidine solution; GVI, 1% peracetic acid; GVII, saline solution. Microbiological samples were taken after root canal preparation and 7 days later. Data were submitted to ANOVA (5%). Results. All solutions promoted reduction of E. faecalis after instrumentation, but bacterial counts were higher in the final sample. GI, GV, and GVI had lower bacterial counts than the other groups. Conclusions. The irrigating solutions may present activity but do not eradicate E. faecalis in the root canal system. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2011; 112:396-400)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We conducted an open, randomized, and prospective study to determine the effect of hypertonic saline on the secretion of antidiuretic hormone (ADH) and aldosterone in children with severe head injury (Glasgow coma scale <8). Thirty-one consecutive patients at a level III pediatric intensive care unit at a children's hospital received either lactated Ringer's solution (Ringer's group, n = 16) or hypertonic saline (Hypertonic Saline group, n = 15) over a 3-day period. Serum ADH levels were significantly larger in the Hypertonic Saline group as compared with the Ringer's group (P = 0.001; analysis of variance) and were correlated to sodium intake (Ringer's group: r = 0.39, R(2) = 0.15, P = 0.02; Hypertonic Saline group: r = 0.42, R(2) = 0.18, P = 0.02) and volume of fluids given IV (Ringer's group: r = 0.38, R(2) = 0.15, P = 0.02; Hypertonic Saline group: r = 0.32, R(2) = 0.1, P = not significant). Correlation of ADH to plasma osmolality was significant if plasma osmolality was >280 mOsm/kg (r = 0.5, R(2) = 0.25, P = 0.06), indicating an osmotic threshold for ADH release. Serum aldosterone levels were larger on the first day than during Days 2 and 3 in both groups and inversely correlated to serum sodium levels only in the Ringer's group (r = -0.55, R(2) = 0.3, P < 0.001). This group received a significantly larger fluid volume on Day 1 (P = 0.05, Mann-Whitney U-test) than did patients in the Hypertonic Saline group, indicating hypovolemia during the first day. Head-injured children have appropriate levels of ADH. They may be hypovolemic during the first day of treatment, especially if they receive lactated Ringer's solution. IMPLICATIONS: In head-injured patients, we recommend fluid restriction to avoid inappropriate secretion of antidiuretic hormone. In a prospective, randomized, and controlled study in 31 children, we were able to show that the antidiuretic hormone levels are appropriate in response to hypovolemia, sodium load, or both.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: Resuscitation in severe head injury may be detrimental when given with hypotonic fluids. We evaluated the effects of lactated Ringer's solution (sodium 131 mmol/L, 277 mOsm/L) compared with hypertonic saline (sodium 268 mmol/L, 598 mOsm/L) in severely head-injured children over the first 3 days after injury. DESIGN: An open, randomized, and prospective study. SETTING: A 16-bed pediatric intensive care unit (ICU) (level III) at a university children's hospital. PATIENTS: A total of 35 consecutive children with head injury. INTERVENTIONS: Thirty-two children with Glasgow Coma Scores of <8 were randomly assigned to receive either lactated Ringer's solution (group 1) or hypertonic saline (group 2). Routine care was standardized, and included the following: head positioning at 30 degrees; normothermia (96.8 degrees to 98.6 degrees F [36 degrees to 37 degrees C]); analgesia and sedation with morphine (10 to 30 microg/kg/hr), midazolam (0.2 to 0.3 mg/kg/hr), and phenobarbital; volume-controlled ventilation (PaCO2 of 26.3 to 30 torr [3.5 to 4 kPa]); and optimal oxygenation (PaO2 of 90 to 105 torr [12 to 14 kPa], oxygen saturation of >92%, and hematocrit of >0.30). MEASUREMENTS AND MAIN RESULTS: Mean arterial pressure and intracranial pressure (ICP) were monitored continuously and documented hourly and at every intervention. The means of every 4-hr period were calculated and serum sodium concentrations were measured at the same time. An ICP of 15 mm Hg was treated with a predefined sequence of interventions, and complications were documented. There was no difference with respect to age, male/female ratio, or initial Glasgow Coma Score. In both groups, there was an inverse correlation between serum sodium concentration and ICP (group 1: r = -.13, r2 = .02, p < .03; group 2: r = -.29, r2 = .08, p < .001) that disappeared in group 1 and increased in group 2 (group 1: r = -.08, r2 = .01, NS; group 2: r = -.35, r2 =.12, p < .001). Correlation between serum sodium concentration and cerebral perfusion pressure (CPP) became significant in group 2 after 8 hrs of treatment (r = .2, r2 = .04, p = .002). Over time, ICP and CPP did not significantly differ between the groups. However, to keep ICP at <15 mm Hg, group 2 patients required significantly fewer interventions (p < .02). Group 1 patients received less sodium (8.0 +/- 4.5 vs. 11.5 +/- 5.0 mmol/kg/day, p = .05) and more fluid on day 1 (2850 +/- 1480 vs. 2180 +/- 770 mL/m2, p = .05). They also had a higher frequency of acute respiratory distress syndrome (four vs. 0 patients, p = .1) and more than two complications (six vs. 1 patient, p = .09). Group 2 patients had significantly shorter ICU stay times (11.6 +/- 6.1 vs. 8.0 +/- 2.4 days; p = .04) and shorter mechanical ventilation times (9.5 +/- 6.0 vs. 6.9 +/- 2.2 days; p = .1). The survival rate and duration of hospital stay were similar in both groups. CONCLUSIONS: Treatment of severe head injury with hypertonic saline is superior to that treatment with lactated Ringer's solution. An increase in serum sodium concentrations significantly correlates with lower ICP and higher CPP. Children treated with hypertonic saline require fewer interventions, have fewer complications, and stay a shorter time in the ICU.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this work we study the colloidal osmotic pressure (COP) and aggregate shape in phosphate saline buffer solutions (PH 7.4) containing bovine serum albumin (BSA), poly(ethylene glycol) lipid (PEG(2000)-PE) and Dextran (Dx). Dx was added to the BSA/PEG(2000)-PE system in order to increase the COP of the solution to levels comparable to the COP of healthy adults, with the aim of using the solution as a blood COP regulator. Dynamic light scattering and small angle X-ray scattering results shown the formation of BSA/PEG(2000)-PE/Dx aggregates in the solution. Osmometry results shown that the addition of Dx to the BSA/PE2000-PE system could successfully increase the COP, through the formation of BSA/PEG(2000)-PE/Dx aggregates. The BSA/PEG(2000)-PE/Dx solutions attained COP= 15 mm Hg, representing 60% of COP measured for healthy adults. (c) 2008 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The smaller volemic state from hypertonic (7.5%) saline (HS) solution administration in hemorrhagic shock can determine lesser systemic oxygen delivery and tissue oxygenation than conventional plasma expanders. In a model of hemorrhagic shock in dogs, we studied the systemic and gastrointestinal oxygenation effects of HS and hyperoncotic (6%) dextran-70 in combination with HS (HSD) solutions in comparison with lactated Ringer's (LR) and (6%) hydroxyethyl starch (HES) solutions. Forty-eight mongrel dogs were anesthetized, mechanically ventilated, and subjected to splenectomy. A gastric air tonometer was placed. in the stomach for intramucosal gastric CO2 (Pgco(2)) determination and for the calculation of intramucosal. pH (pHi):[pHi = pHa - log(Pgco(2)/Paco(2))].The dogs were hemorrhaged (42% of blood volume) to hold mean arterial blood pressure at 40-50 mm Hg over 30 min and were then resuscitated with LR (n = 12) in a 3:1 relation to removed blood volume; HS (n = 12), 6 mL / kg; HSD (n = 12), 6 mL / kg; and HES (mean molecular weight, 200 kDa; degree of substitution, 0.5) (n = 12) in a 1:1 relation to the removed blood volume. Hemodynamic, systemic, and gastric oxygenation variables were measured at baseline, after 30 min of hemorrhage, and 5, 60, and 120 min after intravascular fluid resuscitation. After fluid resuscitation, HS showed significantly lower arterial pH and mixed venous Po-2 and higher systemic oxygen uptake index and systemic oxygenation extraction than LR and HES (P < 0.05), whereas HSD showed significantly lower arterial pH than LR and HES (P < 0.05). Only HS and HSD did not return arterial pH and pHi to control levels (P < 0.05). In conclusion, all solutions improved systemic and gastrointestinal oxygenation after hemorrhagic shock in dogs. However, the HS solution showed the worst response in comparison to LR and HES solutions in relation to systemic oxygenation, whereas HSD showed intermediate values. HS and HSD solutions did not return regional oxygenation to control values.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim To compare the ex vivo antibacterial effectiveness of the Endox Plus system and sodium hypochlorite (NaOCl) in combination with BioPure MTAD (Tulsa Dental, Tulsa, OK, USA) or with EDTA in Enterococcus faecalis-contaminated root canals.Methodology After initial preparation, the root canals of 70 single-rooted human teeth were inoculated with E. faecalis (ATCC 29212) and incubated for 21 days. Specimens were divided into five groups: Endox Plus/saline; 2.5% NaOCl/MTAD; 2.5% NaOCl/EDTA; saline (positive control); negative control (root canals not prepared, nor irrigated). Samples were collected using paper points. Microbiological analysis evaluated the number of CFUs. Data were analysed by anova and Tukey tests at 0.05 significance.Results All specimens had bacterial growth after the incubation period, with similar CFU per mL counts (P > 0.05). After chemo-mechanical preparation, the number of bacteria in all groups reduced, except for the negative control. No significant differences were observed between 2.5% NaOCl/MTAD and 2.5% NaOCl/EDTA, but these groups had lower CFU counts than the other groups (P < 0.05). In the final samples, an increase in the bacterial counts was observed for Endox Plus/saline, 2.5% NaOCl/MTAD, 2.5% NaOCl/EDTA and saline (P < 0.05) with no significant differences between these groups.Conclusions This ex vivo study revealed that the Endox Plus system was associated with a reduced antibacterial effectiveness compared with conventional irrigation using 2.5% NaOCl/MTAD and 2.5% NaOCl/EDTA. All irrigation procedures allowed recovery of bacteria 7 days after treatment, demonstrating persistence of contamination within the root canal system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)