819 resultados para SUBMILLIMETER WAVELENGTHS
Resumo:
We present a secondary eclipse observation for the hot Jupiter HD 189733b across the wavelength range 290-570 nm made using the Space Telescope Imaging Spectrograph on the Hubble Space Telescope. We measure geometric albedos of Ag = 0.40 ± 0.12 across 290-450 nm and Ag < 0.12 across 450-570 nm at 1σ confidence. The albedo decrease toward longer wavelengths is also apparent when using six wavelength bins over the same wavelength range. This can be interpreted as evidence for optically thick reflective clouds on the dayside hemisphere with sodium absorption suppressing the scattered light signal beyond ~450 nm. Our best-fit albedo values imply that HD 189733b would appear a deep blue color at visible wavelengths.
Resumo:
This Doctoral Thesis entitled Contribution to the analysis, design and assessment of compact antenna test ranges at millimeter wavelengths aims to deepen the knowledge of a particular antenna measurement system: the compact range, operating in the frequency bands of millimeter wavelengths. The thesis has been developed at Radiation Group (GR), an antenna laboratory which belongs to the Signals, Systems and Radiocommunications department (SSR), from Technical University of Madrid (UPM). The Radiation Group owns an extensive experience on antenna measurements, running at present four facilities which operate in different configurations: Gregorian compact antenna test range, spherical near field, planar near field and semianechoic arch system. The research work performed in line with this thesis contributes the knowledge of the first measurement configuration at higher frequencies, beyond the microwaves region where Radiation Group features customer-level performance. To reach this high level purpose, a set of scientific tasks were sequentially carried out. Those are succinctly described in the subsequent paragraphs. A first step dealed with the State of Art review. The study of scientific literature dealed with the analysis of measurement practices in compact antenna test ranges in addition with the particularities of millimeter wavelength technologies. Joint study of both fields of knowledge converged, when this measurement facilities are of interest, in a series of technological challenges which become serious bottlenecks at different stages: analysis, design and assessment. Thirdly after the overview study, focus was set on Electromagnetic analysis algorithms. These formulations allow to approach certain electromagnetic features of interest, such as field distribution phase or stray signal analysis of particular structures when they interact with electromagnetic waves sources. Properly operated, a CATR facility features electromagnetic waves collimation optics which are large, in terms of wavelengths. Accordingly, the electromagnetic analysis tasks introduce an extense number of mathematic unknowns which grow with frequency, following different polynomic order laws depending on the used algorithmia. In particular, the optics configuration which was of our interest consisted on the reflection type serrated edge collimator. The analysis of these devices requires a flexible handling of almost arbitrary scattering geometries, becoming this flexibility the nucleus of the algorithmia’s ability to perform the subsequent design tasks. This thesis’ contribution to this field of knowledge consisted on reaching a formulation which was powerful at the same time when dealing with various analysis geometries and computationally speaking. Two algorithmia were developed. While based on the same principle of hybridization, they reached different order Physics performance at the cost of the computational efficiency. Inter-comparison of their CATR design capabilities was performed, reaching both qualitative as well as quantitative conclusions on their scope. In third place, interest was shifted from analysis - design tasks towards range assessment. Millimetre wavelengths imply strict mechanical tolerances and fine setup adjustment. In addition, the large number of unknowns issue already faced in the analysis stage appears as well in the on chamber field probing stage. Natural decrease of dynamic range available by semiconductor millimeter waves sources requires in addition larger integration times at each probing point. These peculiarities increase exponentially the difficulty of performing assessment processes in CATR facilities beyond microwaves. The bottleneck becomes so tight that it compromises the range characterization beyond a certain limit frequency which typically lies on the lowest segment of millimeter wavelength frequencies. However the value of range assessment moves, on the contrary, towards the highest segment. This thesis contributes this technological scenario developing quiet zone probing techniques which achieves substantial data reduction ratii. Collaterally, it increases the robustness of the results to noise, which is a virtual rise of the setup’s available dynamic range. In fourth place, the environmental sensitivity of millimeter wavelengths issue was approached. It is well known the drifts of electromagnetic experiments due to the dependance of the re sults with respect to the surrounding environment. This feature relegates many industrial practices of microwave frequencies to the experimental stage, at millimeter wavelengths. In particular, evolution of the atmosphere within acceptable conditioning bounds redounds in drift phenomena which completely mask the experimental results. The contribution of this thesis on this aspect consists on modeling electrically the indoor atmosphere existing in a CATR, as a function of environmental variables which affect the range’s performance. A simple model was developed, being able to handle high level phenomena, such as feed - probe phase drift as a function of low level magnitudes easy to be sampled: relative humidity and temperature. With this model, environmental compensation can be performed and chamber conditioning is automatically extended towards higher frequencies. Therefore, the purpose of this thesis is to go further into the knowledge of millimetre wavelengths involving compact antenna test ranges. This knowledge is dosified through the sequential stages of a CATR conception, form early low level electromagnetic analysis towards the assessment of an operative facility, stages for each one of which nowadays bottleneck phenomena exist and seriously compromise the antenna measurement practices at millimeter wavelengths.
Resumo:
This paper proposes a quiet zone probing approach which deals with low dynamic range quiet zone acquisitions. Lack of dynamic range is a feature of millimeter and sub-millimeter wavelength technologies. It is consequence of the gradually smaller power generated by the instrumentation, that follows a f^α law with frequency, being α≥1 variable depending on the signal source’s technology. The proposed approach is based on an optimal data reduction scenario which redounds in a maximum signal to noise ratio increase for the signal pattern, with minimum information losses. After theoretical formulation, practical applications of the technique are proposed.
Resumo:
Las bandas de las denominadas ondas milimétricas y submilimétricas están situadas en la región del espectro entre las microondas y el infrarrojo. La banda de milimétricas se sitúa entre 30 y 300 GHz, considerada normalmente como la banda EHF (Extremely High Frequency). El margen de frecuencias entre 300 y 3000 GHz es conocido como la banda de ondas submilimétricas o de terahercios (THz). Sin embargo, no toda la comunidad científica está de acuerdo acerca de las frecuencias que limitan la banda de THz. De hecho, 100 GHz y 10 THz son considerados comúnmente como los límites inferior y superior de dicha banda, respectivamente. Hasta hace relativamente pocos años, la banda de THz sólo había sido explotada para aplicaciones en los campos de la espectroscopía y la radioastronomía. Los avances tecnológicos en la electrónica de microondas y la óptica lastraron el desarrollo de la banda de THz. Sin embargo, investigaciones recientes han demostrado las ventajas asociadas a operar en estas longitudes de onda, lo que ha aumentado el interés y los esfuerzos dedicados a la tecnología de THz. A pesar de que han surgido un gran número de aplicaciones, una de las más prometedoras está en el campo de la vigilancia y la seguridad. Esta tesis está dedicada al desarrollo de radares de onda continua y frecuencia modulada (CW-LFM) de alta resolución en la banda de milimétricas, más concretamente, en las ventanas de atenuación situadas en 100 y 300 GHz. Trabajar en estas bandas de frecuencia presenta beneficios tales como la capacidad de las ondas de atravesar ciertos materiales como la ropa o el papel, opacos en el rango visible, y la posibilidad de usar grandes anchos de banda, obteniéndose así elevadas resoluciones en distancia. Los anchos de banda de 9 y 27 GHz seleccionados para los sistemas de 100 y 300 GHz, respectivamente, proporcionan resoluciones en distancia alrededor y por debajo del cm. Por otro lado, las aplicaciones objetivo se centran en la adquisición de imágenes a corto alcance. En el caso del prototipo a 300 GHz, su diseño se ha orientado a aplicaciones de detección a distancia en escenarios de vigilancia y seguridad. La naturaleza no ionizante de esta radiación supone una ventaja frente a las alternativas tradicionalmente usadas tales como los sistemas de rayos X. La presente tesis se centra en el proceso de diseño, implementación y caracterización de ambos sistemas así como de la validación de su funcionamiento. Se ha elegido una solución basada en componentes electrónicos, y no ópticos, debido a su alta fiabilidad, volumen reducido y amplia disponibilidad de componentes comerciales. Durante el proceso de diseño e implementación, se han tenido en cuenta varias directrices tales como la minimización del coste y la versatilidad de los sistemas desarrollados para hacer posible su aplicación para múltiples propósitos. Ambos sistemas se han utilizado en diferentes pruebas experimentales, obteniendo resultados satisfactorios. Aunque son sólo ejemplos dentro del amplio rango de posibles aplicaciones, la adquisición de imágenes ISAR de modelos de blancos a escala para detección automática así como la obtención de datos micro-Range/micro- Doppler para el análisis de patrones humanos han validado el funcionamiento del sistema a 100 GHz. Por otro lado, varios ejemplos de imágenes 3D obtenidas a 300 GHz han demostrado las capacidades del sistema para su uso en tareas de seguridad y detección a distancia. ABSTRACT The millimeter- and submillimeter-wave bands are the regions of the spectrum between the microwaves and the infrared (IR). The millimeter-wave band covers the range of the spectrum from 30 to 300 GHz, which is usually considered as the extremely high frequency (EHF) band. The range of frequencies between 300 and 3000 GHz is known as the submillimeter-wave or terahertz (THz) band. Nevertheless, the boundaries of the THz band are not accepted by the whole research community. In fact, 100 GHz and 10 THz are often considered by some authors as the lower and upper limit of this band, respectively. Until recently, the THz band had not been exploited for practical applications, with the exception of minor uses in the fields of spectroscopy and radio astronomy. The advancements on microwave electronics and optical technology left the well-known THz gap undeveloped. However, recent research has unveiled the advantages of working at these frequencies, which has motivated the increase in research effort devoted to THz technology. Even though the range of upcoming applications is wide, the most promising ones are in the field of security and surveillance. Particularly, this Ph.D. thesis deals with the development of high resolution continuouswave linear-frequency modulated (CW-LFM) radars in the millimeter-wave band, namely, in the attenuation windows located at 100 and 300 GHz. Working at these wavelengths presents several benefits such as the ability of radiation to penetrate certain materials, visibly opaque, and the great availability of bandwidth at these frequencies, which leads to high range resolution. The selected bandwidths of 9 and 27 GHz for these systems at 100 and 300 GHz, respectively, result in cm and sub-cm range resolution. On the other hand, the intended applications are in the field of short-range imaging. In particular, the design of the 300-GHz prototype is oriented to standoff detection for security and surveillance scenarios. The non-ionizing nature of this radiation allows safety concerns to be alleviated, in clear contrast to other traditional alternatives such as X-rays systems. This thesis is focused on the design, implementation and characterization process of both systems as well as the experimental assessment of their performances. An electronic approach has been selected instead of an optical solution so as to take advantage of its high reliability, reduced volume and the availability of commercial components. Through the whole design and implementation process, several guidelines such as low cost and hardware versatility have been also kept in mind. Taking advantage of that versatility, different applications can be carried out with the same hardware concept. Both radar systems have been used in several experimental trials with satisfactory results. Despite being mere examples within the wide range of fields of application, ISAR imaging of scaled model targets for automatic target recognition and micro-Range/micro-Doppler analysis of human patterns have validated the system performance at 100 GHz. In addition, 3D imaging examples at 300 GHz demonstrate the radar system’s capabilities for standoff detection and security tasks.
Resumo:
Esta tesis está dedicada al análisis de las guías de onda y el diseño de los componentes pasivos con énfasis en aplicaciones de alta frecuencia. En primer lugar, se lleva a cabo el análisis de las guías de onda con conductores metálicos no ideales, con el objetivo de establecer el límite superior en frecuencia de las aproximaciones habitualmente utilizadas en microondas para el cálculo de las pérdidas óhmicas. Posteriormente, se presenta el diseño de diferentes componentes pasivos de guía de ondas: filtros, transductores de modos ortogonales (OMT), polarizadores, duplexores y alimentadores de antena, funcionando en frecuencias desde 10 a 750 GHz. Para el correcto diseño de componentes a altas frecuencias se requiere, en primer lugar, comprender los nuevos procesos de fabricación y después adecuar los diversos componentes para cumplir especificaciones eléctricas y geométricas simultáneamente. Para esto, se presentan modificaciones y nuevas geometrías de guiado de ondas para diferentes aplicaciones y procesos tecnológicos. Además se discuten sus ventajas sobre las soluciones ya existentes. Además, el trabajo presentado en esta tesis se ocupa del desarrollo completo de dispositivos: diseño, fabricación y caracterización de los componentes ya mencionados. Por último, algunos de los dispositivos desarrollados han sido diseñados para ser integrados en diferentes sistemas. De esta forma, se mejoran las prestaciones y capacidades de dichos sistemas.
Resumo:
"Contract No. AT(30-1)-2543."
Resumo:
A method of discriminating between temperature and strain effects in fibre sensing using a conventionally written, in-fibre Bragg grating is presented. The technique uses wavelength information from the first and second diffraction orders of the grating element to determine the wavelength dependent strain and temperature coefficients, from which independent temperature and strain measurements can be made. The authors present results that validate this matrix inversion technique and quantify the strain and temperature errors which can arise for a given uncertainty in the measurement of the reflected wavelength.
Resumo:
A method of discriminating between temperature and strain effects in fibre sensing using a conventionally written, in-fibre Bragg grating is presented. The technique uses wavelength information from the first and second diffraction orders of the grating element to determine the wavelength dependent strain and temperature coefficients, from which independent temperature and strain measurements can be made. The authors present results that validate this matrix inversion technique and quantify the strain and temperature errors which can arise for a given uncertainty in the measurement of the reflected wavelength.
Resumo:
The spectral narrowing and selective tuning of picosecond pulse outputs from gain-switched diode laser and a four Bragg-grating fiber, were investigated. The fiber used under investigation was designed to provide spectral narrowing and multiple wavelength/temporal output. The maximum transmission out of each of the four output fibers was ∼7.5 mW, for a current of 180 mA. The results show that an output of any combination of multiple wavelengths is only produced at modulation frequencies which satisfy resonant conditions for all cavity arms simultaneously.
Resumo:
The optical redox ratio as a measure of cellular metabolism is determined by an altered ratio between endogenous fluorophores NADH and flavin adenine dinucleotide (FAD). Although reported for other cancer sites, differences in optical redox ratio between cancerous and normal urothelial cells have not previously been reported. Here, we report a method for the detection of cellular metabolic states using flow cytometry based on autofluorescence, and a statistically significant increase in the redox ratio of bladder cancer cells compared to healthy controls. Urinary bladder cancer and normal healthy urothelial cell lines were cultured and redox overview was assessed using flow cytometry. Further localisation of fluorescence in the same cells was carried out using confocal microscopy. Multiple experiments show correlation between cell type and redox ratio, clearly differentiating between healthy cells and cancer cells. Based on our preliminary results, therefore, we believe that this data contributes to current understanding of bladder tissue fluorescence and can inform the design of endoscopic probes. This approach also has significant potential as a diagnostic tool for discrimination of cancer cells among shed urothelial cells in voided urine, and could lay the groundwork for an automated system for population screening for bladder cancer.
Resumo:
Spectral albedo in high resolution, from 290 to 1050 nm, has been measured at Neumayer, Antarctica, (70°39' S, 8°15' W) during the austral summer 2003/2004. At 500 nm, the spectral albedo nearly reaches unity, with slightly lower values below and above 500 nm. Above 600 nm, the spectral albedo decreases to values between 0.45 and 0.75 at 1000 nm. For one cloudless case an albedo up to 1.01 at 500 nm could be determined. This can be explained by the larger directional component of the snow reflectivity for direct incidence, combined with a slightly mislevelled sensor and the snow surface not being perfectly horizontal. A possible explanation for an observed decline in albedo is an increase in snow grain size. The theoretically predicted increase in albedo with increasing solar zenith angle (SZA) could not be observed. This is explained by the small range of SZA during albedo measurements, combined with the effect of changing snow conditions outweighing the effect of changing SZA. The measured spectral albedo serves as input for radiative transfer models, describing radiation conditions in Antarctica.
Resumo:
During our Herschel Lensing Survey (HLS) of massive galaxy clusters, we have discovered an exceptionally bright source behind the z = 0.22 cluster Abell 773, which appears to be a strongly lensed submillimeter galaxy (SMG) at z = 5.2429. This source is unusual compared to most other lensed sources discovered by Herschel so far, because of its higher submm flux (∼200 mJy at 500 μm) and its high redshift. The dominant lens is a foreground z = 0.63 galaxy, not the cluster itself. The source has a far-infrared (FIR) luminosity of L_FIR = 1.1 × 10^14/μ L_⨀, where μ is the magnification factor, likely ∼11. We report here the redshift identification through CO lines with the IRAM-30 m, and the analysis of the gas excitation, based on CO(7–6), CO(6–5), CO(5–4) detected at IRAM and the CO(2–1) at the EVLA. All lines decompose into a wide and strong red component, and a narrower and weaker blue component, 540 km s^−1 apart. Assuming the ultraluminous galaxy (ULIRG) CO-to-H_2 conversion ratio, the H_2 mass is 5.8×10^11/μ M_⨀, of which one third is in a cool component. From the CI(^3P_2−^3 P_1) line we derive a C_I/H_2 number abundance of 6 × 10^−5 similar to that in other ULIRGs. The H_2O_p(2, 0, 2−1, 1, 1) line is strong only in the red velocity component, with an intensity ratio I(H_2O)/I(CO) ∼ 0.5, suggesting a strong local FIR radiation field, possibly from an active nucleus (AGN) component. We detect the [NII]205 μm line for the first time at high-z. It shows comparable blue and red components, with a strikingly broad blue one, suggesting strong ionized gas flows.
Resumo:
The Herschel Lensing Survey (HLS) takes advantage of gravitational lensing by massive galaxy clusters to sample a population of high-redshift galaxies which are too faint to be detected above the confusion limit of current far-infrared/submillimeter telescopes. Measurements from 100-500 μm bracket the peaks of the far-infrared spectral energy distributions of these galaxies, characterizing their infrared luminosities and star formation rates. We introduce initial results from our science demonstration phase observations, directed toward the Bullet cluster (1E0657-56). By combining our observations with LABOCA 870 μm and AzTEC 1.1 mm data we fully constrain the spectral energy distributions of 19 MIPS 24 μm-selected galaxies which are located behind the cluster. We find that their colors are best fit using templates based on local galaxies with systematically lower infrared luminosities. This suggests that our sources are not like local ultra-luminous infrared galaxies in which vigorous star formation is contained in a compact highly dust-obscured region. Instead, they appear to be scaled up versions of lower luminosity local galaxies with star formation occurring on larger physical scales.
Resumo:
Utilization of graphene covered waveguide inserts to form tunable waveguide resonators is theoretically explained and rigorously investigated by means of full-wave numerical electromagnetic simulations. Instead of using graphene-based switching elements, the concept we propose incorporates graphene sheets as parts of a resonator. Electrostatic tuning of the graphene surface conductivity leads to changes in the electromagnetic field boundary conditions at the resonator edges and surfaces, thus producing an effect similar to varying the electrical length of a resonator. The presented outline of the theoretical background serves to give phenomenological insight into the resonator behavior, but it can also be used to develop customized software tools for design and optimization of graphene-based resonators and filters. Due to the linear dependence of the imaginary part of the graphene surface impedance on frequency, the proposed concept was expected to become effective for frequencies above 100 GHz, which is confirmed by the numerical simulations. A frequency range from 100 GHz up to 1100 GHz, where the rectangular waveguides are used, is considered. Simple, all-graphene-based resonators are analyzed first, to assess the achievable tunability and to check the performance throughout the considered frequency range. Graphene–metal combined waveguide resonators are proposed in order to preserve the excellent quality factors typical for the type of waveguide discontinuities used. Dependence of resonator properties on key design parameters is studied in detail. Dependence of resonator properties throughout the frequency range of interest is studied using eight different waveguide sections appropriate for different frequency intervals. Proposed resonators are aimed at applications in the submillimeter-wave spectral region, serving as the compact tunable components for the design of bandpass filters and other devices.