980 resultados para STRESS MYOCARDIAL PERFUSION SCINTIGRAPHY


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background-Although assessment of myocardial perfusion by myocardial contrast echocardiography (MCE) is feasible, its incremental benefit to stress echocardiography is not well defined. We examined whether the addition of MCE to combined dipyridamole-exercise echocardiography (DExE) provides incremental benefit for evaluation of coronary artery disease (CAD). Methods and Results-MCE was combined with DExE in 85 patients, 70 of whom were undergoing quantitative coronary angiography and 15 patients with a low probability of CAD. MCE was acquired by low-mechanical-index imaging in 3 apical views after acquisition of standard resting and poststress images. Wall motion, left ventricular opacification, and MCE components of the study were interpreted sequentially, blinded to other data. Significant (>50%) stenoses were present in 43 patients and involved 69 coronary territories. The addition of qualitative MCE improved sensitivity for the detection of CAD (91% versus 74%, P=0.02) and accurate recognition of disease extent (87% versus 65% of territories, P=0.003), with a nonsignificant reduction in specificity. Conclusions-The addition of low-mechanical-index MCE to standard imaging during DExE improves detection of CAD and enables a more accurate determination of disease extent.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives This prospective study investigated the effects of caffeine ingestion on the extent of adenosine-induced perfusion abnormalities during myocardial perfusion imaging (MPI). Methods Thirty patients with inducible perfusion abnormalities on standard (caffeine-abstinent) adenosine MPI underwent repeat testing with supplementary coffee intake. Baseline and test MPIs were assessed for stress percent defect, rest percent defect, and percent defect reversibility. Plasma levels of caffeine and metabolites were assessed on both occasions and correlated with MPI findings. Results Despite significant increases in caffeine [mean difference 3,106 μg/L (95% CI 2,460 to 3,752 μg/L; P < .001)] and metabolite concentrations over a wide range, there was no statistically significant change in stress percent defect and percent defect reversibility between the baseline and test scans. The increase in caffeine concentration between the baseline and the test phases did not affect percent defect reversibility (average change −0.003 for every 100 μg/L increase; 95% CI −0.17 to 0.16; P = .97). Conclusion There was no significant relationship between the extent of adenosine-induced coronary flow heterogeneity and the serum concentration of caffeine or its principal metabolites. Hence, the stringent requirements for prolonged abstinence from caffeine before adenosine MPI—based on limited studies—appear ill-founded.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIMS: We conducted a meta-analysis to evaluate the accuracy of quantitative stress myocardial contrast echocardiography (MCE) in coronary artery disease (CAD). METHODS AND RESULTS: Database search was performed through January 2008. We included studies evaluating accuracy of quantitative stress MCE for detection of CAD compared with coronary angiography or single-photon emission computed tomography (SPECT) and measuring reserve parameters of A, beta, and Abeta. Data from studies were verified and supplemented by the authors of each study. Using random effects meta-analysis, we estimated weighted mean difference (WMD), likelihood ratios (LRs), diagnostic odds ratios (DORs), and summary area under curve (AUC), all with 95% confidence interval (CI). Of 1443 studies, 13 including 627 patients (age range, 38-75 years) and comparing MCE with angiography (n = 10), SPECT (n = 1), or both (n = 2) were eligible. WMD (95% CI) were significantly less in CAD group than no-CAD group: 0.12 (0.06-0.18) (P < 0.001), 1.38 (1.28-1.52) (P < 0.001), and 1.47 (1.18-1.76) (P < 0.001) for A, beta, and Abeta reserves, respectively. Pooled LRs for positive test were 1.33 (1.13-1.57), 3.76 (2.43-5.80), and 3.64 (2.87-4.78) and LRs for negative test were 0.68 (0.55-0.83), 0.30 (0.24-0.38), and 0.27 (0.22-0.34) for A, beta, and Abeta reserves, respectively. Pooled DORs were 2.09 (1.42-3.07), 15.11 (7.90-28.91), and 14.73 (9.61-22.57) and AUCs were 0.637 (0.594-0.677), 0.851 (0.828-0.872), and 0.859 (0.842-0.750) for A, beta, and Abeta reserves, respectively. CONCLUSION: Evidence supports the use of quantitative MCE as a non-invasive test for detection of CAD. Standardizing MCE quantification analysis and adherence to reporting standards for diagnostic tests could enhance the quality of evidence in this field.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background. Stress myocardial contrast echo (MCE) is technically challenging with exercise (Ex) because of cardiacmovementandshort duration ofhyperemia.Vasodilators solve these limitations, but are less potent for inducing abnormal wall motion (WM). We sought whether a combined dipyridamole (DI; 0.56 mg/kg i.v. 4 min) and Ex stress protocol would enable MCE to provide incremental benefit toWManalysis for detection of CAD. Methods. Standard echo images were followed by real time MCE at rest and following stress in 85 pts, 70 undergoing quantitative coronary angiography and 15 low risk pts.WMAfrom standard and LVopacification images, and then myocardial perfusion were assessed sequentially in a blinded fashion. A subgroup of 13 pts also underwent Ex alone, to assess the contribution of DI to quantitative myocardial flow reserve (MFR). Results. Significant (>50%) stenoses were present in 43 pts, involving 69 territories. Addition of MCE improved SE sensitivity for detection of CAD (91% versus 74%, P = 0.02) and better appreciation of disease extent (87% versus 65%territories, P=0.003), with a non-significant reduction in specificity. In 55 territories subtended by a significant stenosis, but with no resting WM abnormality, ability to identify ischemia was also significantly increased by MCE (82% versus 60%, P = 0.002). MFR was less with Ex alone than with DIEx stress (2.4 ± 1.6 versus 4.0 ± 1.9, P = 0.05), suggesting prolongation of hyperaemia with DI may be essential to the results. Conclusions. Dipyridamole-exercise MCE adds significant incremental benefit to standard SE, with improved diagnostic sensitivity and more accurate estimation of extent of CAD.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION: Diabetic patients are at high risk for coronary artery disease (CAD), which is the leading cause of death in this population. The Swiss Society of Endocrinology-Diabetology (SSED) recommends CAD screening for diabetic patients with > or = 2 additional cardiovascular risk factors (CVRF), by stress echocardiography (SE) or myocardial perfusion imaging (MPI). The aim of this study was to assess the application of these guidelines and the treatment of CVRF in the diabetes outpatient clinics of the five Swiss University Hospitals. METHODS: The study was initiated in Lausanne and the study questionnaires were circulated to the endocrinologists of the five Swiss University Hospitals. Practitioners were asked to include consecutive patients attending the diabetes outpatient clinics over one month. Prevalence of CAD, screening methods for CAD, prevalence of CVRF, biological analyses over the last 6 months and medical therapy were recorded. RESULTS: A total of 302 subjects were included. The mean age was 53 +/- 14 years, 68% had type 2 diabetes, 27% type 1 and 5% other types. Among T2DM with > or = 2 CVRF, 45% were screened for CAD according to SSED guidelines. In T2DM 25% had blood pressure < or = 130/80 mm Hg, 15% a lipid profile within target, 23% HbA1c < or = 7.0%. Overall, 2% achieved all 3 targets. CONCLUSIONS: Only 45% of T2DM with > or = 2 CVRF were screened for CAD according to SSED guidelines and 2% of T2DM had proper control over all CVRF. Efforts are still necessary to improve CAD prevention and screening of diabetic patients in Swiss University Hospitals.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract Background: Left ventricular free wall rupture occurs in up to 10% of the in-hospital deaths following myocardial infarction. It is mainly associated with posterolateral myocardial infarction and its antemortem diagnosis is rarely made. Contrast echocardiography has been increasingly used for the evaluation of myocardial perfusion in patients with acute myocardial infarction, with important prognostic implications. In this case, we reported its use for the detection of a mechanical complication following myocardial infarction. Case presentation: A 50-year-old man with acute myocardial infarction in the lateral wall underwent myocardial contrast echocardiography for the evaluation of myocardial perfusion in the third day post-infarction. A perfusion defect was detected in lateral and inferior walls as well as the presence of contrast extrusion from the left ventricular cavity into the myocardium, forming a serpiginous duct extending from the endocardium to the epicardial region of the lateral wall, without communication with the pericardial space. Magnetic resonance imaging confirmed the diagnosis of impending rupture of the left ventricular free wall. While waiting for cardiac surgery, patient presented with cardiogenic shock and died. Anatomopathological findings were consistent with acute myocardial infarction in the lateral wall and a left ventricular free wall rupture at the infarct site. Conclusion: This case illustrates the early diagnosis of left ventricular free wall rupture by contrast echocardiography. Due to its ability to be performed at bedside this modality of imaging has the potential to identify this catastrophic condition in patients with acute myocardial infarction and help to treat these patients with emergent surgery.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIMS: Although an added diagnostic and prognostic value of the global coronary artery calcification (CAC) score as an adjunct to single-photon emission computed tomography (SPECT)-myocardial perfusion image (MPI) has been repeatedly documented, none of the previous studies took advantage of the anatomic information provided by the unenhanced cardiac CT. Therefore, no co-registration has so far been used to match a myocardial perfusion defect with calcifications in the subtending coronary artery. To evaluate the prognostic value of integrating SPECT-MPI with CAC images were obtained from non-enhanced cardiac computed tomography (CT) for attenuation correction to predict major adverse cardiac events (MACE). METHODS AND RESULTS: Follow-up was obtained in 462 patients undergoing a 1-day stress/rest (99m)Tc-teterofosmin SPECT and non-enhanced cardiac CT for attenuation correction. Survival free of MACE was determined using the Kaplan-Meier method. After integrating MPI and CT findings, patients were divided into three groups (i) MPI defect matched by calcification (CAC ≥ 1) in the subtending coronary artery (ii) unmatched MPI and CT finding (iii) normal finding by MPI and CT. At a mean follow-up of 34.5 ± 13 months, a MACE was observed in 80 patients (33 death, 6 non-fatal myocardial infarction, 9 hospitalizations due to unstable angina, and 32 revascularizations). Survival analysis revealed the most unfavourable outcome (P < 0.001 log-rank test) for patients with a matched finding. CONCLUSION: In the present study, a novel approach using a combined integration of cardiac SPECT-CAC imaging allows for refined risk stratification, as a matched defect emerged as an independent predictor of MACE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIMS: Myocardial blood flow (MBF) is the gold standard to assess myocardial blood supply and, as recently shown, can be obtained by myocardial contrast echocardiography (MCE). The aims of this human study are (i) to test whether measurements of collateral-derived MBF by MCE are feasible during elective angioplasty and (ii) to validate the concept of pressure-derived collateral-flow assessment. METHODS AND RESULTS: Thirty patients with stable coronary artery disease underwent MCE of the collateral-receiving territory during and after angioplasty of 37 stenoses. MCE perfusion analysis was successful in 32 cases. MBF during and after angioplasty varied between 0.060-0.876 mL min(-1) g(-1) (0.304+/-0.196 mL min(-1) g(-1)) and 0.676-1.773 mL min(-1) g(-1) (1.207+/-0.327 mL min(-1) g(-1)), respectively. Collateral-perfusion index (CPI) is defined as the rate of MBF during and after angioplasty varied between 0.05 and 0.67 (0.26+/-0.15). During angioplasty, simultaneous measurements of mean aortic pressure, coronary wedge pressure, and central venous pressure determined the pressure-derived collateral-flow index (CFI(p)), which varied between 0.04 and 0.61 (0.23+/-0.14). Linear-regression analysis demonstrated an excellent agreement between CFI(p) and CPI (y=0.88 x +0.01; r(2)=0.92; P<0.0001). CONCLUSION: Collateral-derived MBF measurements by MCE during angioplasty are feasible and proved that the pressure-derived CFI exactly reflects collateral relative to normal myocardial perfusion in humans.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The coronary artery calcium (CAC) score is a readily and widely available tool for the noninvasive diagnosis of atherosclerotic coronary artery disease (CAD). The aim of this study was to investigate the added value of the CAC score as an adjunct to gated SPECT for the assessment of CAD in an intermediate-risk population. METHODS: Seventy-seven prospectively recruited patients with intermediate risk (as determined by the Framingham Heart Study 10-y CAD risk score) and referred for coronary angiography because of suspected CAD underwent stress (99m)Tc-tetrofosmin SPECT myocardial perfusion imaging (MPI) and CT CAC scoring within 2 wk before coronary angiography. The sensitivity and specificity of SPECT alone and of the combination of the 2 methods (SPECT plus CAC score) in demonstrating significant CAD (>/=50% stenosis on coronary angiography) were compared. RESULTS: Forty-two (55%) of the 77 patients had CAD on coronary angiography, and 35 (45%) had abnormal SPECT results. The CAC score was significantly higher in subjects with perfusion abnormalities than in those who had normal SPECT results (889 +/- 836 [mean +/- SD] vs. 286 +/- 335; P < 0.0001). Similarly, with rising CAC scores, a larger percentage of patients had CAD. Receiver-operating-characteristic analysis showed that a CAC score of greater than or equal to 709 was the optimal cutoff for detecting CAD missed by SPECT. SPECT alone had a sensitivity and a specificity for the detection of significant CAD of 76% and 91%, respectively. Combining SPECT with the CAC score (at a cutoff of 709) improved the sensitivity of SPECT (from 76% to 86%) for the detection of CAD, in association with a nonsignificant decrease in specificity (from 91% to 86%). CONCLUSION: The CAC score may offer incremental diagnostic information over SPECT data for identifying patients with significant CAD and negative MPI results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Myocardial perfusion imaging with SPECT (SPECT-MPI) and 64-slice CT angiography (CTA) are both established techniques for the noninvasive evaluation of coronary artery disease (CAD). Three-dimensional (3D) SPECT/CT image fusion may offer an incremental diagnostic value by integrating both sets of information. We report our first clinical experiences with fused 3D SPECT/CT in CAD patients. METHODS: Thirty-eight consecutive patients with at least 1 perfusion defect on SPECT-MPI (1-d adenosine stress/rest SPECT with (99m)Tc-tetrofosmin) and 64-slice CTA were included. 3D volume-rendered fused SPECT/CT images were generated and compared with the findings from the side-by-side analysis with regard to coronary lesion interpretation by assigning the perfusion defects to their corresponding coronary lesion. RESULTS: The fused SPECT/CT images added information on pathophysiologic lesion severity in 27 coronary stenoses (22%) of 12 patients (29%) (P<0.001). Among 40 equivocal lesions on side-by-side analysis, the fused interpretation confirmed hemodynamic significance in 14 lesions and excluded functional relevance in 10 lesions. In 3 lesions, assignment of perfusion defect and coronary lesion appeared to be reliable on side-by-side analysis but proved to be inaccurate on fused interpretation. Added diagnostic information by SPECT/CT was more commonly found in patients with stenoses of small vessels (P=0.004) and involvement of diagonal branches (P=0.01). CONCLUSION: In addition to being intuitively convincing, 3D SPECT/CT fusion images in CAD may provide added diagnostic information on the functional relevance of coronary artery lesions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Preservation of myocardial perfusion during general anesthesia is likely important in patients at risk for perioperative cardiac complications. Data related to the influence of general anesthesia on the normal myocardial circulation are limited. In this study, we investigated myocardial microcirculatory responses to pharmacological vasodilation and sympathetic stimulation during general anesthesia with sevoflurane in healthy humans immediately before surgical stimulation. METHODS Six female and 7 male subjects (mean age 43 years, range 28-61) were studied at baseline while awake and during the administration of 1 minimum alveolar concentration sevoflurane. Using myocardial contrast echocardiography, myocardial blood flow (MBF) and microcirculatory variables were assessed at rest, during adenosine-induced hyperemia, and after cold pressor test-induced sympathetic stimulation. MBF was calculated from the relative myocardial blood volume multiplied by its exchange frequency (β) divided by myocardial tissue density (ρT), which was set at 1.05 g·mL(-1). RESULTS During sevoflurane anesthesia, MBF at rest was similar to baseline values (1.05 ± 0.28 vs 1.05 ± 0.32 mL·min(-1)·g(-1); P = 0.98; 95% confidence interval [CI], -0.18 to 0.18). Myocardial blood volume decreased (P = 0.0044; 95% CI, 0.01-0.04) while its exchange frequency (β) increased under sevoflurane anesthesia when compared with baseline. In contrast, hyperemic MBF was reduced during anesthesia compared with baseline (2.25 ± 0.5 vs 3.53 ± 0.7 mL·min(-1)·g(-1); P = 0.0003; 95% CI, 0.72-1.84). Sympathetic stimulation during sevoflurane anesthesia resulted in a similar MBF compared to baseline (1.53 ± 0.53 and 1.55 ± 0.49 mL·min(-1)·g(-1); P = 0.74; 95% CI, -0.47 to 0.35). CONCLUSIONS In otherwise healthy subjects who are not subjected to surgical stimulation, MBF at rest and after sympathetic stimulation is preserved during sevoflurane anesthesia despite a decrease in myocardial blood volume. However, sevoflurane anesthesia reduces hyperemic MBF, and thus MBF reserve, in these subjects.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Clinical evaluation of arterial potency in acute ST-elevation myocardial infarction (STEMI) is unreliable. We sought to identify infarction and predict infarct-related artery potency measured by the Thrombolysis In Myocardial Infarction (TIMI) score with qualitative and quantitative intravenous myocardial contrast echocardiography (MCE). Thirty-four patients with suspected STEMI underwent MCE before emergency angiography and planned angioplasty. MCE was performed with harmonic imaging and variable triggering intervals during intravenous administration of Optison. Myocardial perfusion was quantified offline, fitting an exponential function to contrast intensity at various pulsing intervals. Plateau myocardial contrast intensity (A), rate of rise (beta), and myocardial flow (Q = A x beta) were assessed in 6 segments. Qualitative assessment of perfusion defects was sensitive for the diagnosis of infarction (sensitivity 93%) and did not differ between anterior and inferior infarctions. However, qualitative assessment had only moderate specificity (50%), and perfusion defects were unrelated to TIMI flow. In patients with STEMI, quantitatively derived myocardial blood flow Q (A x beta) was significantly lower in territories subtended by an artery with impaired (TIMI 0 to 2) flow than those territories supplied by a reperfused artery with TIMI 3 flow (10.2 +/- 9.1 vs 44.3 +/- 50.4, p = 0.03). Quantitative flow was also lower in segments with impaired flow in the subtending artery compared with normal patients with TIMI 3 flow (42.8 +/- 36.6, p = 0.006) and all segments with TIMI 3 flow (35.3 +/- 32.9, p = 0.018). An receiver-operator characteristic curve derived cut-off Q value of

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To evaluate the effectiveness of intravenous thrombolysis in combination with nicorandil in the treatment of acute ST-segment elevation myocardial infarction (STEMI). Methods: Patients who developed acute STEMI and underwent intravenous thrombolysis in the hospital were selected and divided into observation group (n = 128) and control group (n = 114). Besides thrombolytic therapy, the observation group was also given 20 mg of nicorandil. The control group received conventional thrombolytic therapy only. Clinical effects and rehabilitation of patients were observed. Results: Cardiac troponin I (cTNI) level of the observation group was 4.0 ± 1.5, 8.3 ± 2.8 and 9.8 ± 3.9 after 4, 12 and 24 h, respectively, which is much lower than 5.8 ± 1.4, 11.4 ± 2.7 and 13.2 ± 4.2 in the control group (p < 0.05). ST-segment resolution of observation group was higher (44 ± 14, 52 ± 17, 69 ± 21 and 80 ± 18) % at different time points, compared with the control group (p < 0.05). The proportion of patients with Curtis-Walker score > 3 points, and ventricular wall motion score (4.70 %; 1.38 ± 0.11) in the observation group were both lower than those of the control group (21.00 %; 1.43 ± 0.15) (p < 0.05). The difference in adverse cardiac events between the observation group (N = 6, 4.70 %) and control group (N = 12, 10.50 %) was not statistically significant (p > 0.05) Conclusion: Combining intravenous thrombolysis with nicorandil therapy can enhance myocardial perfusion level, reduce myocardial damage, improve cardiac function and decrease risk of arrhythmia for acute STEMI patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conventional invasive coronary angiography is the clinical gold standard for detecting of coronary artery stenoses. Noninvasive multidetector computed tomography (MDCT) in combination with retrospective ECG gating has recently been shown to permit visualization of the coronary artery lumen and detection of coronary artery stenoses. Single photon emission tomography (SPECT) perfusion imaging has been considered the reference method for evaluation of nonviable myocardium, but magnetic resonance imaging (MRI) can accurately depict structure, function, effusion, and myocardial viability, with an overall capacity unmatched by any other single imaging modality. Magnetocardiography (MCG) provides noninvasively information about myocardial excitation propagation and repolarization without the use of electrodes. This evolving technique may be considered the magnetic equivalent to electrocardiography. The aim of the present series of studies was to evaluate changes in the myocardium assessed with SPECT and MRI caused by coronary artery disease, examine the capability of multidetector computed tomography coronary angiography (MDCT-CA) to detect significant stenoses in the coronary arteries, and MCG to assess remote myocardial infarctions. Our study showed that in severe, progressing coronary artery disease laser treatment does not improve global left ventricular function or myocardial perfusion, but it does preserve systolic wall thickening in fixed defects (scar). It also prevents changes from ischemic myocardial regions to scar. The MCG repolarization variables are informative in remote myocardial infarction, and may perform as well as the conventional QRS criteria in detection of healed myocardial infarction. These STT abnormalities are more pronounced in patients with Q-wave infarction than in patients with non-Q-wave infarctions. MDCT-CA had a sensitivity of 82%, a specificity of 94%, a positive predictive value of 79%, and a negative predictive value of 95% for stenoses over 50% in the main coronary arteries as compared with conventional coronary angiography in patients with known coronary artery disease. Left ventricular wall dysfunction, perfusion defects, and infarctions were detected in 50-78% of sectors assigned to calcifications or stenoses, but also in sectors supplied by normally perfused coronary arteries. Our study showed a low sensitivity (sensitivity 63%) in detecting obstructive coronary artery disease assessed by MDCT in patients with severe aortic stenosis. Massive calcifications complicated correct assessment of the lumen of coronary arteries.