974 resultados para SEPARATION EFFICIENCY


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Biofluid behaviour in microchannel systems is investigated in this paper through the modelling of a microfluidic biochip developed for the separation of blood plasma. Based on particular assumptions, the effects of some mechanical features of the microchannels on behaviour of the biofluid are explored. These include microchannel, constriction, bending channel, bifurcation as well as channel length ratio between the main and side channels. The key characteristics and effects of the microfluidic dynamics are discussed in terms of separation efficiency of the red blood cells with respect to the rest of the medium. The effects include the Fahraeus and Fahraeus-Lindqvist effects, the Zweifach-Fung bifurcation law, the cell-free layer phenomenon. The characteristics of the microfluid dynamics include the properties of the laminar flow as well as particle lateral or spinning trajectories. In this paper the fluid is modelled as a single-phase flow assuming either Newtonian or Non-Newtonian behaviours to investigate the effect of the viscosity on flow and separation efficiency. It is found that, for a flow rate controlled Newtonian flow system, viscosity and outlet pressure have little effect on velocity distribution. When the fluid is assumed to be Non-Newtonian more fluid is separated than observed in the Newtonian case, leading to reduction of the flow rate ratio between the main and side channels as well as the system pressure as a whole.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Joule heat-induced hot-spot formation sets severe limits in the operation of continuous annular electrochromatography (CAEC), a new concept for preparative separation as an analog to analytical capillary electrochromatography (CEC). This may lead to eluent flow perturbance, even to boiling, which would massively weaken separation efficiency and may even hamper the stationary phase used for separation. For reasons of system integration and high-efficiency heat transfer, micro flow heat exchangers are considered with a separate coolant flow. A 3D numerical analysis of the heat transfer of water single-phase laminar flow in a square microchannel and different arrays of micro pin-fins was carried out using COMSOL Multiphysics. Several advanced materials with low electric conductivity and at the same time with high heat conductivity were put forward to be used in the CAEC system. As essential design point, it is proposed to constitute the micro heat exchanger from two different parts of the CAEC system, namely a microstructured pin-fins plate and a so-called conductive plate.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The eluent droplet size defines the number of sampling compartments in a continuously operated annular electrochromatograph and therefore influences separation efficiency. In this work, an assembly of two capillaries, a feeding capillary on the top and a receiving capillary placed under it, has been investigated to control droplet size. The receiving capillary prevents the liquid droplet formation beyond a critical size, which reduces the volume of sampling compartment as compared with the case of the electrolyte flow driven solely by gravity. With a receiving capillary, the electrolyte droplet size was reduced from 1.5 to 0.46 mm. Further decrease of droplet size was not possible due to a so-called droplet jump upwards effect which has been observed on a hydrophilic glass surface with water. A typical electrolyte used in CAEC has high methanol content. In an attempt to improve the methanol-repellent properties of the glass surface, two approaches have been implemented: (i) self-assembled chemisorbed monolayers of an alkylsiloxane and (ii) fabrication of a nano-pin film. The methanol-repellent surface of the feeding capillary suppressed the droplet jump upwards effect. The surface remained methanol repellent in different solutions with lower polarity than that of water.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In the catalytic hydrogenation of benzene to cyclohexane, the separation of unreacted benzene from the product stream is inevitable and essential for an economically viable process. In order to evaluate the separation efficiency of ionic liquids (ILs) as a solvent in this extraction processes, the ternary (liquid + liquid) equilibrium of 1-alkyl-3-methylimidazolium hexafluorophosphate, [Cnmim][PF6] (n = 4, 5, 6), with benzene and cyclohexane was studied at T = 298.15 K and atmospheric pressure. The reliability of the experimentally determined tie-line data was confirmed by applying the Othmer–Tobias equation. The solute distribution coefficient and solvent selectivity for the systems studied were calculated and compared with literature data for other ILs and sulfolane. It turns out that the benzene distribution coefficient increases and solvent selectivity decreases as the length of the cation alkyl chain grows, and the ionic liquids [Cnmim][PF6] proved to be promising solvents for benzene–cyclohexane extractive separation. Finally, an NRTL model was applied to correlate and fit the experimental LLE data for the ternary systems studied.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Factors affecting the detennination of PAHs by capillary GC/MS were studied. The effect of the initial column temperature and the injection solvent on the peak areas and heights of sixteen PAHs, considered as priority pollutants, USillg crosslinked methyl silicone (DB!) and 5% diphenyl, 94% dimethyl, 1% vinyl polysiloxane (DBS) columns was examined. The possibility of using high boiling point alcohols especially butanol, pentanol, cyclopentanol, and hexanol as injection solvents was investigated. Studies were carried out to optimize the initial column temperature for each of the alcohols. It was found that the optimum initial column temperature is dependent on the solvent employed. The peak areas and heights of the PAHs are enhanced when the initial column temperature is 10-20 c above the boiling point of the solvent using DB5 column, and the same or 10 C above the boiling point of the solvent using DB1 column. Comparing the peak signals of the PAHs using the alcohols, p-xylene, n-octane, and nonane as injection solvents, hexanol gave the greatest peak areas and heights of the PAHs particularly the late-eluted peaks. The detection limits were at low pg levels, ranging from 6.0 pg for fluorene t9 83.6 pg for benzo(a)pyrene. The effect of the initial column temperature on the peak shape and the separation efficiency of the PARs was also studied using DB1 and DB5 columns. Fronting or splitting of the peaks was obseIVed at very low initial column temperature. When high initial column temperature was used, tailing of the peaks appeared. Great difference between DB! and.DB5 columns in the range of the initial column temperature in which symmetrical.peaks of PAHs can be obtained is observed. Wider ranges were shown using DB5 column. Resolution of the closely-eluted PAHs was also affected by the initial column temperature depending on the stationary phase employed. In the case of DB5, only the earlyeluted PAHs were affected; whereas, with DB1, all PAHs were affected. An analytical procedure utilizing solid phase extraction with bonded phase silica (C8) cartridges combined with GC/MS was developed to analyze PAHs in water as an alternative method to those based on the extraction with organic solvent. This simple procedure involved passing a 50 ml of spiked water sample through C8 bonded phase silica cartridges at 10 ml/min, dried by passing a gentle flow of nitrogen at 20 ml/min for 30 sec, and eluting the trapped PAHs with 500 Jll of p-xylene at 0.3 ml/min. The recoveries of PAHs were greater than 80%, with less than 10% relative standard deviations of nine determinations. No major contaminants were present that could interfere with the recognition of PAHs. It was also found that these bonded phase silica cartridges can be re-used for the extraction of PAHs from water.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

La protéomique est un sujet d'intérêt puisque l'étude des fonctions et des structures de protéines est essentiel à la compréhension du fonctionnement d'un organisme donné. Ce projet se situe dans la catégorie des études structurales, ou plus précisément, la séquence primaire en acides aminés pour l’identification d’une protéine. La détermination des protéines commence par l'extraction d'un mélange protéique issu d'un tissu ou d'un fluide biologique pouvant contenir plus de 1000 protéines différentes. Ensuite, des techniques analytiques comme l’électrophorèse en gel polyacrylamide en deux dimensions (2D-SDS-PAGE), qui visent à séparer ce mélange en fonction du point isoélectrique et de la masse molaire des protéines, sont utilisées pour isoler les protéines et pour permettre leur identification par chromatographie liquide and spectrométrie de masse (MS), typiquement. Ce projet s'inspire de ce processus et propose que l'étape de fractionnement de l'extrait protéique avec la 2D-SDS-PAGE soit remplacé ou supporté par de multiples fractionnements en parallèle par électrophorèse capillaire (CE) quasi-multidimensionnelle. Les fractions obtenues, contenant une protéine seule ou un mélange de protéines moins complexe que l’extrait du départ, pourraient ensuite être soumises à des identifications de protéines par cartographie peptidique et cartographie protéique à l’aide des techniques de séparations analytiques et de la MS. Pour obtenir la carte peptidique d'un échantillon, il est nécessaire de procéder à la protéolyse enzymatique ou chimique des protéines purifiées et de séparer les fragments peptidiques issus de cette digestion. Les cartes peptidiques ainsi générées peuvent ensuite être comparées à des échantillons témoins ou les masses exactes des peptides enzymatiques sont soumises à des moteurs de recherche comme MASCOT™, ce qui permet l’identification des protéines en interrogeant les bases de données génomiques. Les avantages exploitables de la CE, par rapport à la 2D-SDS-PAGE, sont sa haute efficacité de séparation, sa rapidité d'analyse et sa facilité d'automatisation. L’un des défis à surmonter est la faible quantité de masse de protéines disponible après analyses en CE, due partiellement à l'adsorption des protéines sur la paroi du capillaire, mais due majoritairement au faible volume d'échantillon en CE. Pour augmenter ce volume, un capillaire de 75 µm était utilisé. Aussi, le volume de la fraction collectée était diminué de 1000 à 100 µL et les fractions étaient accumulées 10 fois; c’est-à-dire que 10 produits de séparations étaient contenu dans chaque fraction. D'un autre côté, l'adsorption de protéines se traduit par la variation de l'aire d'un pic et du temps de migration d'une protéine donnée ce qui influence la reproductibilité de la séparation, un aspect très important puisque 10 séparations cumulatives sont nécessaires pour la collecte de fractions. De nombreuses approches existent pour diminuer ce problème (e.g. les extrêmes de pH de l’électrolyte de fond, les revêtements dynamique ou permanent du capillaire, etc.), mais dans ce mémoire, les études de revêtement portaient sur le bromure de N,N-didodecyl-N,N-dimethylammonium (DDAB), un surfactant qui forme un revêtement semi-permanent sur la paroi du capillaire. La grande majorité du mémoire visait à obtenir une séparation reproductible d'un mélange protéique standard préparé en laboratoire (contenant l’albumine de sérum de bovin, l'anhydrase carbonique, l’α-lactalbumine et la β-lactoglobulin) par CE avec le revêtement DDAB. Les études portées sur le revêtement montraient qu'il était nécessaire de régénérer le revêtement entre chaque injection du mélange de protéines dans les conditions étudiées : la collecte de 5 fractions de 6 min chacune à travers une séparation de 30 min, suivant le processus de régénération du DDAB, et tout ça répété 10 fois. Cependant, l’analyse en CE-UV et en HPLC-MS des fractions collectées ne montraient pas les protéines attendues puisqu'elles semblaient être en-dessous de la limite de détection. De plus, une analyse en MS montrait que le DDAB s’accumule dans les fractions collectées dû à sa désorption de la paroi du capillaire. Pour confirmer que les efforts pour recueillir une quantité de masse de protéine étaient suffisants, la méthode de CE avec détection par fluorescence induite par laser (CE-LIF) était utilisée pour séparer et collecter la protéine, albumine marquée de fluorescéine isothiocyanate (FITC), sans l'utilisation du revêtement DDAB. Ces analyses montraient que l'albumine-FITC était, en fait, présente dans la fraction collecté. La cartographie peptidique a été ensuite réalisée avec succès en employant l’enzyme chymotrypsine pour la digestion et CE-LIF pour obtenir la carte peptidique.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

With a solution technique, NaY zeolite incorporated, tetraethylorthosilicate-crosslinked poly(vinyl alcohol) membranes were prepared. The resulting membranes were tested for their ability to separate isopropyl alcohol/water mixtures by pervaporation in the temperature range of 30-50 degrees C. The effects of the zeolite content and feed composition on the pervaporation performance of the membranes were investigated. The experimental results demonstrated that both flux and selectivity increased simultaneously with increasing zeolite content in the membranes. This was explained on the basis of the enhancement of hydrophilicity, selective adsorption, and establishment of a molecular sieving action attributed to the creation of pores in the membrane matrix. The membrane containing 15 mass % zeolite exhibited the highest separation selectivity of 3991 with a flux of 5.39 X 10(-2) kg/m(2) h with 10 mass % water in the feed at 30 degrees C. The total flux and flux of water were close to each other for almost all the studied membranes, and this suggested that the membranes could be used effectively to break the azeotropic point of water/isopropyl alcohol mixtures to remove a small amount of water from isopropyl alcohol. From the temperature-dependent diffusion and permeation values, the Arrhenius activation parameters were estimated. The activation energy values obtained for water were significantly lower than those for isopropyl alcohol, and this suggested that the developed membranes had a higher separation efficiency for water/isopropyl alcohol systems. The activation energy values for total permeation and water permeation were found to be almost the same for all the membranes, and this signified that coupled transport was minimal because of the highly selective nature of the membranes. Positive heat of sorption values were observed in all the membranes, and this suggested that Henry's mode of sorption was predominant. (c) 2008 Wiley Periodicals, lnc.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The recovery of lactoferrin and lactoperoxidase from sweet whey was studied using colloidal gas aphrons (CGAs), which are surfactant-stabilized microbubbles (10-100 mum). CGAs are generated by intense stirring (8000 rpm for 10 min) of the anionic surfactant AOT (sodium bis-2-ethylhexyl sulfosuccinate). A volume of CGAs (10-30 mL) is mixed with a given volume of whey (1 - 10 mL), and the mixture is allowed to separate into two phases: the aphron (top) phase and the liquid (bottom) phase. Each of the phases is analyzed by SDS-PAGE and surfactant colorimetric assay. A statistical experimental design has been developed to assess the effect of different process parameters including pH, ionic strength, the concentration of surfactant in the CGAs generating solution, the volume of CGAs and the volume of whey on separation efficiency. As expected pH, ionic strength and the volume of whey (i.e. the amount of total protein in the starting material) are the main factors influencing the partitioning of the Lf(.)Lp fraction into the aphron phase. Moreover, it has been demonstrated that best separation performance was achieved at pH = 4 and ionic strength = 0.1 mol/L i.e., with conditions favoring electrostatic interactions between target proteins and CGAs (recovery was 90% and the concentration of lactoferrin and lactoperoxidase in the aphron phase was 25 times higher than that in the liquid phase), whereas conditions favoring hydrophobic interactions (pH close to pI and high ionic strength) led to lower performance. However, under these conditions, as confirmed by zeta potential measurements, the adsorption of both target proteins and contaminant proteins is favored. Thus, low selectivity is achieved at all of the studied conditions. These results confirm the initial hypothesis that CGAs act as ion exchangers and that the selectivity of the process can be manipulated by changing main operating parameters such as type of surfactant, pH and ionic strength.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this report, we describe a rapid and reliable process to bond channels fabricated in glass substrates. Glass channels were fabricated by photolithography and wet chemical etching. The resulting channels were bonded against another glass plate containing a 50-mu m thick PDMS layer. This same PDMS layer was also used to provide the electrical insulation of planar electrodes to carry out capacitively coupled contactless conductivity detection. The analytical performance of the proposed device was shown by using both LIF and capacitively coupled contactless conductivity detection systems. Efficiency around 47 000 plates/m was achieved with good chip-to-chip repeatability and satisfactory long-term stability of EOF. The RSD for the EOF measured in three different devices was ca. 7%. For a chip-to-chip comparison, the RSD values for migration time, electrophoretic current and peak area were below 10%. With the proposed approach, a single chip can be fabricated in less than 30 min including patterning, etching and sealing steps. This fabrication process is faster and easier than the thermal bonding process. Besides, the proposed method does not require high temperatures and provides excellent day-to-day and device-to-device repeatability.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper compares the analytical performance of microchannels fabricated in PDMS, glass, and polyester-toner for electrophoretic separations. Glass and PDMS chips were fabricated using well-established photolithographic and replica-molding procedures, respectively. PDMS channels were sealed against three different types of materials: native PDMS, plasma-oxidized PDMS, and glass. Polyester-toner chips were micromachined by a direct-printing process using an office laser printer. All microchannels were fabricated with similar dimensions according to the limitations of the direct-printing process (width/depth 150 mu m/12 mu m). LIF was employed for detection to rule out any losses in separation efficiency due to the detector configuration. Two fluorescent dyes, coumarin and fluorescein, were used as model analytes. Devices were evaluated for the following parameters related to electrophoretic separations: EOF, heat dissipation, injection reproducibility, separation efficiency, and adsorption to channel wall.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O presente trabalho estuda a viabilidade da utilização do processo de flotação a ar dissolvido (FAD) no tratamento de efluentes contendo cromo. Tal processo é analisado comparativamente à sedimentação. Urna revisão dos diferentes tipos de processos de separação ou de recuperação do cromo é, também, aqui apresentada. Soluções contendo 200 mg.l" de cromo tri ou hexavalente foram estudadas quanto às condições ideais de precipitação, às características de sedimentação e de flotação a ar dissalvido em regime descontínuo e contlnuo. Agentes poliméricos foram testados no intuito de melhorar as condições de clarificação. O processo de FAD foi o que apresentou melhores resultados no que se refere a cinética de separação sólido/líquido, e em termos de clarificação das soluções. Estudos de separação sólido/líquido de soluções contendo cromo VI foram feitos por estes dois processos empregando sulfato ferroso e sulfito de sódio como agentes redutores. A FAD mostrou ser eficiente para tratar as soluções quando reduzidas com sulfito de sódio. Porém, no caso da utilização do sulfato ferroso como redutor, o rendimento da FAD diminuiu no tratamento de soluções que continham sólidos suspensos acima de uma concentração crítica. Polímeros também foram empregados neste caso, e confirmaram sua atuação melhorando a cinética de separação sólido/líquido e como agentes que beneficiam a clarificação das soluções. Os resultados dos estudos de flotação por ar dissolvido em uma unidade contínua mostraram que é viavel a FAD sem agentes floculantes ou tensoativos. No entanto, estes aumentam os níveis de clarificação das soluções. Apenas os floculantes a base de amido mostraram-se ineficientes nesta aplicação. Conclui-se que o processo de FAD pode ser utilizado no tratamento de efluentes contendo cromo permitindo obter efluentes finais dentro dos padrões de emissão da legislação brasileira.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In the oil industry the mixture oil/water occurs in the operations of production, transportation and refining, as well as during the use of its derivatives. The amount of water produced associated with the oil varies and can reach values of 90% in volume in the case of mature phase of the production fields. The present work deals with the development of new design of the Mixer Settler based on Phase Inversion (MDIF) in a laboratory scale. We envisage this application in industrial scale so the phases of project, construction and operation are considered. The modifications most significant, in comparison with the original prototype, include the materials of construction and the substitution of the equipment used in the mixing stage of the process. It was tested the viability of substitution of the original system of mechanical mixing by a static mixer. A statistical treatment by means of an experimental design of composed central type was used in order to evaluate the behavior of the main variables of the separation process as function of the efficiency of separation for the new device. This procedure is useful to delimit an optimal region of operation with the equipment. The variables of process considered on the experimental design were: oil concentration in the feeding water (mg/L); Total volumetric flow rate (L/h); Ratio organic/water on volumetric basis (O/A). The separation efficiency is calculated by comparison of the content of oil and greases in the inlet and outlet of the equipment. For determination of TOG (Total Oil and Grease), the method used was based in the absorption of radiation in the infra-red region. The equipment used for these determinations was InfraCal® TOG/TPH Model HATR-T2 of the Wilks Enterprise, Incorporation. It´s important to stand out that this method of measure has being used by PETROBRAS S.A. Results of global efficiency of separation oil/water varied from 75.3 to 97.7% for contaminated waters containing up to 1664,1 mg/L of oil. By means of tests carried out with a real sample of contaminated water supplied by PETROBRAS we have got an effluent specified in terms of the legal standards required for discharging. Thus, the new design of equipment constitutes a real alternative for the conventional systems of treatment of produced water in the oil industry

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This work aims to use a different hydrodynamic condition applied to a new design of mixer-settler on treating wastewater produced by petroleum industry, called MDIF (Misturador-Decantador à Inversão de Fases/ Mixer-Settler based on Phase Inversion MSPI). The use of this different hydrodynamic behaviour is possible due to vertical disposition of the device and the principle of Phase Inversion that controls the MDIF, providing the generation (creation) of a cascade of drops, into an organic layer, that works as micro-decanters, thus making possible the formation of a bed of non-coalesced drops, called Bed Formation . The use of this new hydrodynamics condition allows to increase the residence time of the oil carrier drops, into an organic layer, and the device can treat a greater volume of wastewater. In view of to get this condition it is necessary to operate at high throughput (58,6 m3.m-2.h-1). By results, the condition of Bed Formation is the best one to be used when MSPI operates with throughput up to 58,6 m3.m-2.h-1. The results using the condition of Bed Formation show that increasing the height of the bed of non-coalesced drops and/or decreasing the volumetric ratio (O/A) an increase of the separation efficiency is detected

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The present work had as objective to apply an experimental planning aiming at to improve the efficiency of separation of a new type of mixer-settler applied to treat waste water contaminated with oil. An unity in scale of laboratory, was installed in the Post-graduation Program of Chemical Engineering of UFRN. It was constructed in partnership with Petrobras S.A. This called device Misturador-Decantador a Inversão de Fases (MDIF) , possess features of conventional mixer-settler and spray column type. The equipment is composed of three main parts: mixing chamber; chamber of decantation and chamber of separation. The efficiency of separation is evaluated analyzing the oil concentrations in water in the feed and the output of the device. For the analysis one used the gravimetric method of oil and greases analysis (TOG). The system in study is a water of formation emulsified with oil. The used extractant is a mixture of Turpentine spirit hydro-carbons, supplied for Petrobras. It was applied, for otimization of the efficiency of separation of the equipment, an experimental planning of the composite central type, having as factorial portion fractionary factorial planning 2 5-2, with the magnifying of the type star and five replications in the central point. In this work, the following independents variables were studied: contents of oil in the feed of the device; volumetric ratio (O/A); total flowrate ; agitation in the mixing chamber and height of the organic bed. Minimum and maximum limits for the studied variables had been fixed according previous works. The analysis of variance for the equation of the empirical model, revealed statistically significant and useful results for predictions ends. The variance analysis also presented the distribution of the error as a normal distribution and was observed that as the dispersions do not depend on the levels of the factors, the independence assumption can be verified. The variation around the average is explained by 98.98%, or either, equal to the maximum value, being the smoothing of the model in relation to the experimental points of 0,98981. The results present a strong interaction between the variable oil contents in the feed and agitation in the mixing chamber, having great and positive influence in the separation efficiency. Another variable that presented a great positive influence was the height of the organic bed. The best results of separation efficiency had been obtained for high flowrates when associates the high oil concentrations and high agitation. The results of the present work had shown excellent agreement with the results carried out through previous works with the mixer-settler of phase inversion

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In recent decades, the generation of solid and liquid waste has increased substantially due to increased industrial activity that is directly linked to economic growth. For that is the most efficient process, it is inevitable generation of such wastes. In the oil industry, a major waste generated in oil exploration is produced water, which due to its complex composition and the large amount generated, has become a challenge, given the restrictions imposed by environmental laws regarding their disposal, making if necessary create alternatives for reuse or treatment in order to reduce the content of contaminants and reduce the harmful effects to the environment. This water can be present in free form or emulsified with the oil, when in the form of an emulsion of oil-water type, it is necessary to use chemicals to promote the separation and flotation is the treatment method which has proved to be more efficient, for it can remove much of the emulsified oil when compared to other methods. In this context, the object of this work was to study the individual effects and interactions of some physicochemical parameters of operations, based on previous work to a flotation cell used in the separation of synthetic emulsion oil / water in order to optimize the efficiency of the separation process through of the 24 full factorial design with center point. The response variables to evaluate the separation efficiency was the percentage of color and turbidity removal. The independent variables were: concentration of de-emulsifying, oil content in water, salinity and pH, these being fixed, minimum and maximum limits. The analysis of variance for the equation of the empirical model, was statistically significant and useful for predictive purposes the separation efficiency of the floater with R2 > 90%. The results showed that the oil content in water and the interaction between the oil content in water and salinity, showed the highest values of the estimated effects among all the factors investigated, having great and positive influence on the separation efficiency. By analyzing the response surface was determined maximum removal efficiency above 90% for both measured for turbidity as a measure of color when in a saline medium (30 g/L), the high oil concentrations (306 ppm) using low concentrations of de-emulsifying (1,1 ppm) and at pH close to neutral