984 resultados para Rigid internal fixation


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: This multicentre study aimed to investigate long-term radiographic and functional results following the treatment of condylar fractures using an angulated screwdriver system and open rigid internal fixation with an intraoral surgical approach.Methods: Twenty-nine patients with a total of 32 condylar fractures were evaluated. The patients were investigated prospectively based on the following variables: age, sex, aetiology, side, location and classification of the fracture, degree of displacement, associated fractures, surgical approach, oral health status, type of osteosynthesis plate, duration of surgery, mouth-opening, complications, and duration of follow-up.Results: The fractures were classified as subcondylar (n = 25) or condylar neck (n = 7). Mean patient age was 36.38 +/- 16.60 years. The median duration of postoperative follow-up was 24.39 +/- 13.94 months. No joint noise, weakness of the facial nerve, joint pain, or muscle pain was observed. An additional retromandibular approach was necessary to enable the treatment of one subcondylar fracture with medial displacement.Conclusion: Subcondylar or condylar neck fractures with medial or lateral displacement can be treated using an intraoral approach with satisfactory results with the advantages of the absence of visible scarring, the avoidance of facial nerve injury, and the ability to obtain rapid access to the fracture. (C) 2014 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: The treatment of mandibular fractures has undergone many changes, especially after the introduction of rigid internal fixation techniques. Currently, the use of resorbable materials presents some advantages over metallic devices, particularly when applied in children. Objective: The authors discuss the controversies involved in the treatment of mandibular fractures in children, mainly related to fixation of fractures. Case Report: In this paper, we present a case of a 5 years treatment patient with mandibular angle fracture treated by open reduction and internal fixation with plates and screws. Final Comments: Aiming to not interfere in the development of tooth germs and mandibular bone growth a second surgery for removal of the fixation devices is indicated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To evaluate the ratio of soft tissue to hard tissue in bilateral sagittal split setback osteotomy with rigid internal fixation or wire fixation. MATERIALS AND METHODS: A literature search was performed using PubMed, Medline, CINAHL, Web of Science, the Cochrane Library, and Google Scholar Beta. From the original 766 articles identified, 8 articles were included. Two articles were prospective and 6 retrospective. The follow-up period ranged from 1 year to 12.7 years for rigid internal fixation. Two articles on wire fixation were found to be appropriate for inclusion. RESULTS: The differences between short- and long-term ratios of the lower lip to lower incisors for bilateral sagittal split setback osteotomy with rigid internal fixation or wire fixation were quite small. The ratio was 1:1 in the long term and by trend slightly lower in the short term. No distinction was seen between the short- and long-term ratios for mentolabial fold. The ratio was found to be 1:1 for the mentolabial fold to point B. In the short term, the ratio of the soft tissue pogonion to the pogonion showed a 1:1 ratio, with a trend to be lower in the long term. The upper lip showed mainly protrusion, but the amount was highly variable. CONCLUSIONS: This systematic review shows that evidence-based conclusions on soft tissue changes are difficult to draw. This is mostly because of inherent problems of retrospective studies, inferior study designs, and the lack of standardized outcome measurements. Well-designed prospective studies with sufficient samples and excluding additional surgery, ie, genioplasty or maxillary surgery, are needed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: The purpose of the present systematic review was to evaluate the soft tissue/hard tissue ratio in bilateral sagittal split advancement osteotomy (BSSO) with rigid internal fixation (RIF) or wire fixation (WF). MATERIALS AND METHODS: The databases PubMed, Medline, CINAHL, Web of Science, Cochrane Library, and Google Scholar Beta were searched. From the original 711 articles identified, 12 were finally included. Only 3 studies were prospective and 9 were retrospective. The postoperative follow-up ranged from 3 months to 12.7 years for RIF and 6 months to 5 years for WF. RESULTS: The short- and long-term ratios for the lower lip to lower incisor for BSSO with RIF or WF were 50%. No difference between the short- and long-term ratios for the mentolabial-fold to point B and soft tissue pogonion to pogonion could be observed. It was a 1:1 ratio. One exception was seen for the long-term results of the soft tissue pogonion to pogonion in BSSO with RIF; they tended to be greater than a 1:1 ratio. The upper lip mainly showed retrusion but with high variability. CONCLUSIONS: Despite a large number of studies on the short- and long-term effects of mandibular advancement by BSSO, the results of the present systematic review have shown that evidence-based conclusions on soft tissue changes are still unknown. This is mostly because of the inherent problems of retrospective studies, inferior study designs, and the lack of standardized outcome measures. Well-designed prospective studies with sufficient sample sizes that have excluded patients undergoing additional surgery (ie, genioplasty or maxillary surgery) are needed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: The aim of the study was to conduct a long-term prospective follow-up on the stability of soft tissues after bilateral sagittal split osteotomy (BSSO) with rigid internal fixation to set back the mandible. PATIENTS AND METHODS: Seventeen consecutive patients (6 females, 11 males) were re-examined 12.7 years (T5) after surgery. The precedent follow-ups included: before surgery (T1), 5 days (T2) after surgery, 6.6 months (T3) after surgery, and 14.4 months after (T4) surgery. Lateral cephalograms were traced by hand, digitized, and evaluated with the Dentofacial Planner program (Dentofacial Software, Toronto, Canada). The x-axis for the system of coordinates ran through Sella (point 0) and the line NSL -7 degrees. RESULTS: The net effect of the soft tissue chin (soft tissue pogonion) was 79% of the setback at pogonion. At the lower lip (labrale inferior) it was 100% of the setback at lower incisor position. Point B' followed point B to 99%. Labrale inferior and menton' also showed a significant backward, as well as a downward, movement (T5 to T2). Gender correlated significantly (P = .004) with the anterior displacement of point B' and pogonion' (P = .012). The soft tissue relapse 12.7 years after BSSO setback surgery at point B' was 3% and 13% at pogonion'. CONCLUSION: Among the reasons for 3-dimensional long-term soft tissue changes of shape, the surgical technique, the normal process of human aging, the initial growth direction, and remodeling processes must be considered. Growth direction positively influenced the long-term outcome of setback surgery in female compared with male patients because further posterior movement of the mandibular soft tissue occurred.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of the study was to conduct a long-term follow-up on the stability of the hard tissues after bilateral sagittal split osteotomy (BSSO) with rigid internal fixation (RIF)to set back the mandible and to compare it with that of mandibular advancement performed by the same team of surgeons and with the same examination protocol. Seventeen consecutive patients (6 females and 11 males) could be re-examined 12.7 years (T5) after surgery. The previous examinations were before surgery (T1), 5 days (T2), and 6.6 (T3) and 14.4 (T4) months after surgery. Lateral cephalograms were traced by hand, digitized, and evaluated with the Dentofacial Planner software program. The x-axis for the system of co-ordinates ran through sella (point zero) and the line nasion-sella-line minus 7 degrees. The program determined the x- and y-values of each variable and the usual angles and distances. The effects of treatment were determined with Wilcoxon matched pairs, signed ranks test, with Bonferroni adjustment, and the relationship between variables with Spearman rank correlation coefficient. Relapse at point B was 0.94 mm or 15 per cent and at pogonion 1.46 mm or 21 per cent of the initial setback at T5. Relapse was mainly short-term (T4-T2), 13 per cent for point B and 17 per cent for pogonion. Gender correlated significantly with relapse (T5-T2) at point B (P = 0.002) and pogonion (P = 0.021), i.e. females in contrast to males showed further distalization of the mandible instead of relapse. No correlations were seen for age or the amount of surgical setback. The long-term results in mandibular setback patients were more stable when compared with the mandibular advancement patients examined previously. The initial soft tissue profile, the initial growth direction, and the remodelling processes of the hard tissues must be considered as reasons for long-term relapse. Growth direction positively influenced the long-term results in females: further distalization of the mandible occurred.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to compare, by mechanical in vitro testing, a 2.0-mm system made with poly-L-DL-lactide acid with an analogue titanium-based system. Mandible replicas were used as a substrate and uniformly sectioned on the left mandibular angle. The 4-hole plates were adapted and stabilized passively in the same site in both groups using four screws, 6.0 mm long. During the resistance-to-load test, the force was applied perpendicular to the occlusal plane at three different points: first molar at the plated side; first molar at the contralateral side; and between the central incisors. At 1 mm of displacement, no statistically significant difference was found. At 2 mm displacement, a statistically significant difference was observed when an unfavourable fracture was simulated and the load was applied in the contralateral first molar and when a favourable fracture was simulated and the load was applied between the central incisors. At the failure displacement, a statistically significant difference was observed only when the favourable fracture was simulated and the load was applied on the first molar at the plated side. In conclusion, despite more failure, the poly-L-DL-lactic acid-based system was effective.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Bennett fractures are unstable, and, with inadequate treatment, lead to osteoarthritis, weakness and loss of function of the first carpometacarpal joint. This study focuses on long-term functional and radiological outcomes after open reduction and internal fixation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

STUDY DESIGN Biomechanical cadaveric study. OBJECTIVE To determine whether augmentation positively influence screw stability or not. SUMMARY OF BACKGROUND DATA Implantation of pedicle screws is a common procedure in spine surgery to provide an anchorage of posterior internal fixation into vertebrae. Screw performance is highly correlated to bone quality. Therefore, polymeric cement is often injected through specifically designed perforated pedicle screws into osteoporotic bone to potentially enhance screw stability. METHODS Caudocephalic dynamic loading was applied as quasi-physiological alternative to classical pull-out tests on 16 screws implanted in osteoporotic lumbar vertebrae and 20 screws in nonosteoporotic specimen. Load was applied using 2 different configurations simulating standard and dynamic posterior stabilization devices. Screw performance was quantified by measurement of screwhead displacement during the loading cycles. To reduce the impact of bone quality and morphology, screw performance was compared for each vertebra and averaged afterward. RESULTS All screws (with or without cement) implanted in osteoporotic vertebrae showed lower performances than the ones implanted into nonosteoporotic specimen. Augmentation was negligible for screws implanted into nonosteoporotic specimen, whereas in osteoporotic vertebrae pedicle screw stability was significantly increased. For dynamic posterior stabilization system an increase of screwhead displacement was observed in comparison with standard fixation devices in both setups. CONCLUSION Augmentation enhances screw performance in patients with poor bone stock, whereas no difference is observed for patients without osteoporosis. Furthermore, dynamic stabilization systems have the possibility to fail when implanted in osteoporotic bone.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Bone’s capacity to repair following trauma is both unique and astounding. However, fractures sometimes fail to heal. Hence, the goal of fracture treatment is the restoration of bone’s structure, composition and function. Fracture fixation devices should provide a favourable mechanical and biological environment for healing to occur. The use of internal fixation is increasing as these devices may be applied with less invasive techniques. Recent studies suggest however that, internal fixation devices may be overly stiff and suppresses callus formation. The degree of mechanical stability influences the healing outcome. This is determined by the stiffness of the fixation device and the degree of limb loading. This project aims to characterise the fixation stability of an internal plate fixation device and the influence of modifications to its configuration on implant stability. As there are no standardised methods for the determination of fixation stiffness, the first part of this project aims to compares different methodologies and determines the most appropriate method to characterise the stiffness of internal plate fixators. The stiffness of a fixation device also influences the physiological loads experienced by the healing bone. Since bone adapts to this applied load by undergoing changes through a remodelling process, undesirable changes could occur during the period of treatment with an implant. The second part of this project aims to develop a methodology to quantify remodelling changes. This quantification is expected to aid our understanding of the changes in pattern due to implant related remodelling and on the factors driving the remodelling process. Knowledge gained in this project is useful to understand how the configuration of internal fixation devices can promote timely healing and prevent undesirable bone loss.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

An extensible internal device (EID) was developed to preserve growth plate during the treatment of fracture complications or segmental bone loss from tumour resection in children. Since this type of extensible, trans-physeal, internal fixation device has only been used in a few paediatric cases; the aim of this study was to evaluate an in vivo canine study, a surgical application of this device, and its interference with longitudinal growth of the non-fractured distal femur. Ton clinically healthy two- to three-month-old poodles weighing 1.5-2.3 kg were used. Following a medial approach to the right distal femur, one extremity of the EID, similar to a T-plate, was fixed in the femoral condyle with two cortical screws placed below the growth plate. The other extremity, consisting of an adaptable brim with two screw holes and a plate guide, was fixed in the third distal of the femoral diaphysis with two cortical screws. The EID was removed 180 days after application. All of the dogs demonstrated full weight-bearing after surgery. The values of thigh and stifle circumferences, and stifle joint motion range did not show any difference between operated and control hindlimbs. The plate slid in the device according to longitudinal bone growth, in all but one dog. In this dog, a 10.5% shortening of the femoral shaft was observed due to a lack of EID sliding. The other dogs had the some longitudinal lengths in both femurs. The EID permits longitudinal bone growth without blocking the distal femur growth plate if appropriately placed.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Background
Neck of femur fractures (NOFFs) are a common cause of morbidity and mortality in our community. Minimally displaced intracapsular fractures are treated with internal fixation by a two-hole dynamic hip screw (DHS) or three partially threaded cancellous screws. Data to support the superiority of one are limited. This prospective randomized controlled trial compares outcomes with these two fixation methods.

Methods
We prospectively recruited patients over 50 years, with an acute fracture subcapital NOFF, who walked and lived independently, and were cognitively intact. They were randomized into DHS or cancellous screw groups and followed up for 2 years (overall 75.9%). Outcomes of mortality, revision, loss of fixation, avascular necrosis, surgical complications, WOMAC, Harris hip score and SF-12 were measured.

Results
We recruited 62 patients (31 DHS, 29 cancellous screws, 2 failed consent). Six deaths (19.3%) were seen in each group. A total of 3.2% of DHS (1 out of 31) and 10.3% (3 out of 29) of cancellous screw patients required re-operation (P = 0.272). There was no statistical significant difference in patient satisfaction, quality of life (QoL), radiological union or osteonecrosis. There are trends towards better functional scores and QoL in cancellous screws, particularly at 1 year (P = 0.0061), but with a higher re-operation rate. There was a combined mortality and transition to institutional care of 40.0% (24 out of 60) at 2 years.

Conclusions
This study found no difference in outcomes between DHS and cancellous screws in the treatment of subcapital NOFFs in a fit, independent population, but we found a high level of physical decline in previously fit, independently ambulating patients. A large, multicentre trial will be required to differentiate between these two fixation methods.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

An extensible internal device (EID) was developed to preserve growth plate during the treatment of fracture complications or segmental bone loss from tumour resection in children. Since this type of extensible, trans-physeal, internal fixation device has only been used in a few paediatric cases; the aim of this study was to evaluate an in vivo canine study, a surgical application of this device, and its interference with longitudinal growth of the non-fractured distal femur. Ton clinically healthy two- to three-month-old poodles weighing 1.5-2.3 kg were used. Following a medial approach to the right distal femur, one extremity of the EID, similar to a T-plate, was fixed in the femoral condyle with two cortical screws placed below the growth plate. The other extremity, consisting of an adaptable brim with two screw holes and a plate guide, was fixed in the third distal of the femoral diaphysis with two cortical screws. The EID was removed 180 days after application. All of the dogs demonstrated full weight-bearing after surgery. The values of thigh and stifle circumferences, and stifle joint motion range did not show any difference between operated and control hindlimbs. The plate slid in the device according to longitudinal bone growth, in all but one dog. In this dog, a 10.5% shortening of the femoral shaft was observed due to a lack of EID sliding. The other dogs had the some longitudinal lengths in both femurs. The EID permits longitudinal bone growth without blocking the distal femur growth plate if appropriately placed.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The surgical treatment of mandibular condyle fractures currently offers several possibilities for stable internal fixation. In this study, a finite element model evaluation was performed of three different methods for osteosynthesis of low subcondylar fractures: (1) two four-hole straight plates, (2) one seven-hole lambda plate, and (3) one four-hole trapezoidal plate. The finite element model evaluation considered a load applied to the first molar on the contralateral side to the fracture. Results showed that, although the three methods are capable of withstanding functional loading, the lambda plate displayed a more homogeneous stress distribution for both osteosynthesis material and bone and may be a better method when single-plate fixation is the option.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The present study aims to compare three types of internal fixation for fractures of the mandibular angle. Mechanical testing was performed on replicas of polyurethane hemimandibles sectioned at the angle region to simulate a fracture and fixed with three different hardwares. Fixation devices enrolled on this survey included the grid plates with and without an intermediate bar and the method described by Champy and colleagues in 1978 and the sample consisted of 10 hemimandibles for each group. Vertical loadings were applied on each hemimandible and recorded after a vertical displacement of 3 and 5 mm. Statistical analysis was made by means of the variance analysis (ANOVA) and the Duncan test with a significance level of 5%. The Champy technique showed a statistically significant increased resistance when compared to the grid plates after vertical displacements of 3 and 5 mm. The results of this survey suggest that the Champy technique, when compared to the grid plate positioned at the middle of the mandibular bone (placement site selected for this study), is more resistant than the grid plate and that the inclusion or not of an intermediate bar to the grid plates does not improve its resistance after linear vertical loadings.