979 resultados para Repeated Load Triaxial (RLT) test
Resumo:
OBJECTIVES: To develop a method for objective assessment of fine motor timing variability in Parkinson’s disease (PD) patients, using digital spiral data gathered by a touch screen device. BACKGROUND: A retrospective analysis was conducted on data from 105 subjects including65 patients with advanced PD (group A), 15 intermediate patients experiencing motor fluctuations (group I), 15 early stage patients (group S), and 10 healthy elderly subjects (HE) were examined. The subjects were asked to perform repeated upper limb motor tasks by tracing a pre-drawn Archimedes spiral as shown on the screen of the device. The spiral tracing test was performed using an ergonomic pen stylus, using dominant hand. The test was repeated three times per test occasion and the subjects were instructed to complete it within 10 seconds. Digital spiral data including stylus position (x-ycoordinates) and timestamps (milliseconds) were collected and used in subsequent analysis. The total number of observations with the test battery were as follows: Swedish group (n=10079), Italian I group (n=822), Italian S group (n = 811), and HE (n=299). METHODS: The raw spiral data were processed with three data processing methods. To quantify motor timing variability during spiral drawing tasks Approximate Entropy (APEN) method was applied on digitized spiral data. APEN is designed to capture the amount of irregularity or complexity in time series. APEN requires determination of two parameters, namely, the window size and similarity measure. In our work and after experimentation, window size was set to 4 and similarity measure to 0.2 (20% of the standard deviation of the time series). The final score obtained by APEN was normalized by total drawing completion time and used in subsequent analysis. The score generated by this method is hence on denoted APEN. In addition, two more methods were applied on digital spiral data and their scores were used in subsequent analysis. The first method was based on Digital Wavelet Transform and Principal Component Analysis and generated a score representing spiral drawing impairment. The score generated by this method is hence on denoted WAV. The second method was based on standard deviation of frequency filtered drawing velocity. The score generated by this method is hence on denoted SDDV. Linear mixed-effects (LME) models were used to evaluate mean differences of the spiral scores of the three methods across the four subject groups. Test-retest reliability of the three scores was assessed after taking mean of the three possible correlations (Spearman’s rank coefficients) between the three test trials. Internal consistency of the methods was assessed by calculating correlations between their scores. RESULTS: When comparing mean spiral scores between the four subject groups, the APEN scores were different between HE subjects and three patient groups (P=0.626 for S group with 9.9% mean value difference, P=0.089 for I group with 30.2%, and P=0.0019 for A group with 44.1%). However, there were no significant differences in mean scores of the other two methods, except for the WAV between the HE and A groups (P<0.001). WAV and SDDV were highly and significantly correlated to each other with a coefficient of 0.69. However, APEN was not correlated to neither WAV nor SDDV with coefficients of 0.11 and 0.12, respectively. Test-retest reliability coefficients of the three scores were as follows: APEN (0.9), WAV(0.83) and SD-DV (0.55). CONCLUSIONS: The results show that the digital spiral analysis-based objective APEN measure is able to significantly differentiate the healthy subjects from patients at advanced level. In contrast to the other two methods (WAV and SDDV) that are designed to quantify dyskinesias (over-medications), this method can be useful for characterizing Off symptoms in PD. The APEN was not correlated to none of the other two methods indicating that it measures a different construct of upper limb motor function in PD patients than WAV and SDDV. The APEN also had a better test-retest reliability indicating that it is more stable and consistent over time than WAV and SDDV.
Resumo:
Objective: To develop a method for objective quantification of PD motor symptoms related to Off episodes and peak dose dyskinesias, using spiral data gathered by using a touch screen telemetry device. The aim was to objectively characterize predominant motor phenotypes (bradykinesia and dyskinesia), to help in automating the process of visual interpretation of movement anomalies in spirals as rated by movement disorder specialists. Background: A retrospective analysis was conducted on recordings from 65 patients with advanced idiopathic PD from nine different clinics in Sweden, recruited from January 2006 until August 2010. In addition to the patient group, 10 healthy elderly subjects were recruited. Upper limb movement data were collected using a touch screen telemetry device from home environments of the subjects. Measurements with the device were performed four times per day during week-long test periods. On each test occasion, the subjects were asked to trace pre-drawn Archimedean spirals, using the dominant hand. The pre-drawn spiral was shown on the screen of the device. The spiral test was repeated three times per test occasion and they were instructed to complete it within 10 seconds. The device had a sampling rate of 10Hz and measured both position and time-stamps (in milliseconds) of the pen tip. Methods: Four independent raters (FB, DH, AJ and DN) used a web interface that animated the spiral drawings and allowed them to observe different kinematic features during the drawing process and to rate task performance. Initially, a number of kinematic features were assessed including ‘impairment’, ‘speed’, ‘irregularity’ and ‘hesitation’ followed by marking the predominant motor phenotype on a 3-category scale: tremor, bradykinesia and/or choreatic dyskinesia. There were only 2 test occasions for which all the four raters either classified them as tremor or could not identify the motor phenotype. Therefore, the two main motor phenotype categories were bradykinesia and dyskinesia. ‘Impairment’ was rated on a scale from 0 (no impairment) to 10 (extremely severe) whereas ‘speed’, ‘irregularity’ and ‘hesitation’ were rated on a scale from 0 (normal) to 4 (extremely severe). The proposed data-driven method consisted of the following steps. Initially, 28 spatiotemporal features were extracted from the time series signals before being presented to a Multilayer Perceptron (MLP) classifier. The features were based on different kinematic quantities of spirals including radius, angle, speed and velocity with the aim of measuring the severity of involuntary symptoms and discriminate between PD-specific (bradykinesia) and/or treatment-induced symptoms (dyskinesia). A Principal Component Analysis was applied on the features to reduce their dimensions where 4 relevant principal components (PCs) were retained and used as inputs to the MLP classifier. Finally, the MLP classifier mapped these components to the corresponding visually assessed motor phenotype scores for automating the process of scoring the bradykinesia and dyskinesia in PD patients whilst they draw spirals using the touch screen device. For motor phenotype (bradykinesia vs. dyskinesia) classification, the stratified 10-fold cross validation technique was employed. Results: There were good agreements between the four raters when rating the individual kinematic features with intra-class correlation coefficient (ICC) of 0.88 for ‘impairment’, 0.74 for ‘speed’, 0.70 for ‘irregularity’, and moderate agreements when rating ‘hesitation’ with an ICC of 0.49. When assessing the two main motor phenotype categories (bradykinesia or dyskinesia) in animated spirals the agreements between the four raters ranged from fair to moderate. There were good correlations between mean ratings of the four raters on individual kinematic features and computed scores. The MLP classifier classified the motor phenotype that is bradykinesia or dyskinesia with an accuracy of 85% in relation to visual classifications of the four movement disorder specialists. The test-retest reliability of the four PCs across the three spiral test trials was good with Cronbach’s Alpha coefficients of 0.80, 0.82, 0.54 and 0.49, respectively. These results indicate that the computed scores are stable and consistent over time. Significant differences were found between the two groups (patients and healthy elderly subjects) in all the PCs, except for the PC3. Conclusions: The proposed method automatically assessed the severity of unwanted symptoms and could reasonably well discriminate between PD-specific and/or treatment-induced motor symptoms, in relation to visual assessments of movement disorder specialists. The objective assessments could provide a time-effect summary score that could be useful for improving decision-making during symptom evaluation of individualized treatment when the goal is to maximize functional On time for patients while minimizing their Off episodes and troublesome dyskinesias.
Resumo:
Background There is emerging evidence that the physical environment is important for health, quality of life and care, but there is a lack of valid instruments to assess health care environments. The Sheffield Care Environment Assessment Matrix (SCEAM), developed in the United Kingdom, provides a comprehensive assessment of the physical environment of residential care facilities for older people. This paper reports on the translation and adaptation of SCEAM for use in Swedish residential care facilities for older people, including information on its validity and reliability. Methods SCEAM was translated into Swedish and back-translated into English, and assessed for its relevance by experts using content validity index (CVI) together with qualitative data. After modification, the validity assessments were repeated and followed by test-retest and inter-rater reliability tests in six units within a Swedish residential care facility that varied in terms of their environmental characteristics. Results Translation and back translation identified linguistic and semantic related issues. The results of the first content validity analysis showed that more than one third of the items had item-CVI (I-CVI) values less than the critical value of 0.78. After modifying the instrument, the second content validation analysis resulted in I-CVI scores above 0.78, the suggested criteria for excellent content validity. Test-retest reliability showed high stability (96% and 95% for two independent raters respectively), and inter-rater reliability demonstrated high levels of agreement (95% and 94% on two separate rating occasions). Kappa values were very good for test-retest (κ= 0.903 and 0.869) and inter-rater reliability (κ= 0.851 and 0.832). Conclusions Adapting an instrument to a domestic context is a complex and time-consuming process, requiring an understanding of the culture where the instrument was developed and where it is to be used. A team, including the instrument’s developers, translators, and researchers is necessary to ensure a valid translation and adaption. This study showed preliminary validity and reliability evidence for the Swedish version (S-SCEAM) when used in a Swedish context. Further, we believe that the S-SCEAM has improved compared to the original instrument and suggest that it can be used as a foundation for future developments of the SCEAM model.
Resumo:
The clinical importance of evaluating the respiratory muscles with a variety of tests has been proposed by several studies, once that the combination of several tests would allow a better diagnosis and therefore, a better clinical follow of disorders of the respiratory muscles. This study aimed to evaluate the feasibility of adapting a national electronic manovacuometer to measure the nasal inspiratory pressure (study 1) and analyze the level of load intensity of maximum voluntary ventilation, as well as the variables that may influence this maneuver in healthy subjects (study 2). We studied 20 healthy subjects by a random evaluation of two measures of SNIP in different equipments: a national and an imported. In study 2 it was analyzed the intensity of the load of MVV test, change in pressure developed during the maneuver, the possible differences between genders, and the correlations between the flow developed in the test and the result of MVV. In study 1 it was found the average for both measures of nasal inspiratory pressures: 125 ± 42.4 cmH2O for the imported equipment and 131.7 ± 28.7 cmH2O for the national one. Pearson analysis showed a significant correlation between the average, with a coefficient r = 0.63. The average values showed no significant differences evaluated by paired t test (p> 0.05). In the Bland-Altman analysis it was found a BIAS = 7 cmH2O, SD 32.9 and a confidence interval of - 57.5 cmH2O up to 71.5 cmH2O. In the second study it was found significant differences between the genders in the air volume moved, being higher in males 150.9 ± 13.1 l / min vs 118.5 ± 15.7 L / min for (p = 0.0002, 95% CI 44.85 to 20:05). Regarding the inspiratory and expiratory loading, they were significantly higher in men than in women, peak inspiratory pressure (34.7 ± 5.3 cmH2O vs 19.5 ± 4.2 cmH2O, 95% CI - 18.0 to -12.3, p <0.0001), peak expiratory (33.8 vs. 23.1 ± 5.9 cmH2O ± 5.4 cmH2O, 95% CI -17.1 to - 4.6, p <0.0001), and the delta pressure (59.7 ± 10 cmH2O vs 36.8 ± 8.3 cmH2O, 95% CI 14.5 to 31.2, p <0.0002). The Pearson correlation showed that the flow generated by the maneuver is strongly correlated with the delta-expiratory pressure / inspiratory (r2= 0.83,R = 0.91, 95%IC 0.72 a 0.97 e p< 0.0001).Through these results we suggest that the national electronic manovacuometer is feasible and safe to perform the sniff test in healthy subjects. For the MVV, there are differences between the genders in the intensity of pressure developed during the maneuver. We found a load intensity considered low during the MVV, and found a strong correlation between the flow generated in the test and the delta pressure expiratory / inspiratory
Resumo:
Objectives. This paper attempts to provide critical perspectives on common in vitro research methodologies, including shear bond testing, wear testing, and load-to-failure tests. Origins of interest in high-quality laboratory data is reviewed, in vitro data is categorized into property and simulation protocols, and two approaches are suggested for establishing clinical validity. It is hoped that these insights will encourage further progress toward development of in vitro tests that are validated against clinical performance and/or by producing clinically validated failure or damage mechanisms.Materials and methods. Published shear and tensile bond data (macro and micro) is examined in light of published finite element analyses (FEA). This data is subjected to a Weibull scaling analysis to ascertain whether scaling is consistent with failure from the bonded interface or not. Wear tests results are presented in light of the damage mechanism(s) operating. Quantitative wear data is re-examined as being dependent upon contact pressure. Load-to-failure test results are re-analyzed by calculating contact stresses at failure for 119 tests from 54 publications over more than 25 years.Results. FEA analyses and reported failure modes (adhesive, mixed, cohesive) are consistent with failure not involving interfacial "shear stresses" as calculated in published work. Weibull scaling clearly suggests failure involving external surfaces of specimens, not interfacial origins. Contact stresses (pressures) are clearly an important variable in wear testing and are not well-controlled in published work. Load-to-failure tests create damage not seen clinically due to excessively high contact stresses. Most contact stresses in the 119 tests examined were calculated to be between 1000 MPa and 5000 MPa, whereas clinical contact stresses at wear facets have been measured not to exceed 40 MPa.Conclusions. Our community can do a much better job of designing in vitro tests that more closely simulate clinical conditions, especially when contact is involved. Journals are encouraged to thoughtfully consider a ban on publishing papers using bond tests and load-to-failure methods that are seriously flawed and have no clinical relevance. (C) 2011 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Resumo:
This paper presents and discusses Ménard Pressuremeter test results used to predict bearing capacity of pounded piles installed in a tropical sandy soil. Fifteen pre-bored pressuremeter tests were carried out at the Experimental Research Site from Unesp - Bauru up to 15 m depth, one test per meter. Several laboratory and in situ tests were carried out in this research site as well as load tests on plates and on piles. Pressuremeter test results were firstly analyzed to determine geotechnical soil parameters based on empirical methods, emphasizing the estimative of the earth pressure coefficient at rest (K0). After that, bearing capacity prediction of pounded piles with 4 m, 7 m and 10 m were made and compared with test results from instrumented load tests. Pressuremeter test results allowed a very good estimative of bearing capacity for the pile with 4 m length and underestimated in 25,7% and 20,0% the bearing capacity for the pile with 7 and 10 m length, respectively. The back analysis of the test results suggests that the appropriate value for the bearing capacity factor for the tested soil-pile system on this soil is equal to 2.
Resumo:
This study evaluated the influence of tooth embedding media on the accuracy ofan electronic apex locator. The root canal length of 20 human mandibular canines was measured by inserting a 15 K-file into the root canal up to the apical foramen. The distance was measured with a digital caliper. The embedding media evaluated were alginate, saline, floral foam or gauze soaked in saline. Electronic root canal length measurement was performed with Root ZX II. Data were analysed using ANOVA for repeated measurements and Tukey test, at a significance level of 5%. There was no difference between the actual root canal length measurement and the electronic reading recorded with alginate medium. The readings obtained with the other media differed from the actual root canal length measurements. Alginate provided greater accuracy in electronic root canal length determination by Root ZX II than saline, floral foam and gauze.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Comparative studies between brown dog tick Rhipicephalus sanguineus populations from Brazil (Jaboticabal, São Paulo) and Argentina (Rafaela, Santa Fé) showed significant biological, morphological and genetic differences between them. This work aimed to study, in a comparative way, the acquisition of resistance in domestic dogs to R. sanguineus from Jaboticabal and Rafaela, after successive and controlled infestations. Ticks were kept in a BOD incubator under controlled conditions (27 °C, 80 % relative humidity, 12-h photoperiod). Ten dogs, Dachshund breed, males and females, 6 months old, short- or long-haired, without prior contact with ticks, were used as hosts. They were distributed into two experimental groups composed of five animals each: G1 infested with ten adult couples of R. sanguineus (Jaboticabal) per animal, and G2 infested with ten adult couples of R. sanguineus (Rafaela) per animal. Ticks' biological parameters and titration of antibodies from the dogs' sera by ELISA test were used for comparison between the strains. Results of the biological parameters showed that the dogs did not acquire immunity to either of the R. sanguineus strains after repeated infestations. The ELISA test showed low antibody titers in sera of dogs from G2, in successive infestations, and higher antibody responses post second and third infestations in G1. It also demonstrated cross-reactivity between sera of dogs infested with R. sanguineus (Jaboticabal) and antigens from R. sanguineus (Rafaela) and vice versa. We conclude that Dachshund dogs did not develop resistance against neither Jaboticabal nor Rafaela strains of R. sanguineus.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Ciência Animal - FMVA
Resumo:
Pós-graduação em Desenvolvimento Humano e Tecnologias - IBRC