139 resultados para Rebolo de CBN


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An HPLC-DAD method for the quantitative analysis of Δ(9)-tetrahydrocannabinol (THC), Δ(9)-tetrahydrocannabinolic acid-A (THCA-A), cannabidiol (CBD), and cannabinol (CBN) in confiscated cannabis products has been developed, fully validated and applied to analyse seized cannabis products. For determination of the THC content of plant material, this method combines quantitation of THCA-A, which is the inactive precursor of THC, and free THC. Plant material was dried, homogenized and extracted with methanol by ultrasonication. Chromatographic separation was achieved with a Waters Alliance 2695 HPLC equipped with a Merck LiChrospher 60 RP-Select B (5μm) precolumn and a Merck LiChroCart 125-4 LiChrospher 60 RP-Select B (5μm) analytical column. Analytes were detected and quantified using a Waters 2996 photo diode array detector. This method has been accepted by the public authorities of Switzerland (Bundesamt für Gesundheit, Federal Office of Public Health), and has been used to analyse 9092 samples since 2000. Since no thermal decarboxylation of THCA-A occurs, the method is highly reproducible for different cannabis materials. Two calibration ranges are used, a lower one for THC, CBN and CBD, and a higher one for THCA-A, due to its dominant presence in fresh plant material. As provider of the Swiss proficiency test, the robustness of this method has been tested over several years, and homogeneity tests even in the low calibration range (1%) show high precision (RSD≤4.3%, except CBD) and accuracy (bias≤4.1%, except CBN).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A retificação, processo final de usinagem de uma peça, utiliza fluidos de corte com a finalidade de lubrificação, refrigeração e remoção de cavacos. No entanto, esses fluidos são extremamente agressivos com o meio. Com o avanço tecnológico a tendência mundial é produzir peças cada vez mais sofisticadas, com elevado grau de tolerância geométrica, dimensional, com bom acabamento superficial, com baixo custo e, principalmente, sem causar danos ao meio. Para tanto, ao processo de retificação está intrínseca a reciclagem do fluido de corte, que se destaca pelo seu custo. Através da variação da velocidade de avanço no processo de retificação cilíndrica externa do aço ABNT D6, racionalizando a aplicação de dois fluidos de corte e usando um rebolo superabrasivo de CBN (nitreto de boro cúbico) com ligante vitrificado, avaliaram-se os parâmetros de saída da força tangencial de corte, emissão acústica, rugosidade, circularidade, desgaste da ferramenta, tensão residual e a integridade superficial através da microscopia eletrônica de varredura (MEV) dos corpos-de-prova. Com a análise do desempenho do fluido, do rebolo e da velocidade de mergulho, encontraram-se as melhores condições de usinagem propiciando a diminuição do volume de fluido de corte e a diminuição do tempo de usinagem, sem prejudicar os parâmetros geométricos e dimensionais, o acabamento superficial e a integridade superficial dos componentes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

One of the problems found in mechanical harvest of sugar cane is the lack of synchronism between the harvest machine and the infield wagon, causing crop losses as well as operational capacity. The objective of the present research was to design a system capable of helping to synchronize the sugar cane harvest machine with the wagon. The communication between tractor and harvest machine is wireless. Two ultrasound sensors coupled to the elevator and a microprocessor manage such information, generating a correct synchronization among the machines. The system was tested in laboratory and on field performing its function adequately, maintaining the two machines in synchronization, indicating and alerting the operators their relative positions. The developed system reduced the sugar cane lost in 60 kg ha-1 comparing to the harvest with the system turned off.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nickel-based super alloys are used in a variety of applications in which high-temperature strength and resistance to creep, corrosion, and oxidation are required, such as in aircraft gas turbines, combustion chambers, and automotive engine valves. The properties that make these materials suitable for these applications also make them difficult to grind. Grinding systems for such materials are often built around vitrified cBN (cubic boron nitride) wheels to realize maximum productivity and minimum cost per part. Conditions that yield the most economical combination of stock removal rate and wheel wear are key to the successful implementation of the grinding system. Identifying the transition point for excessive wheel wear is important. The aim of this study is to compare the performance of different cBN wheels when grinding difficult-to-grind (DTG) materials by determining the 'wheel wear characteristic curve', which correlates the G-ratio to the calculated tangential force per abrasive grain. With the proposed methodology, a threshold force per grit above which the wheel wear rate increases rapidly can be quickly identified. A comparison of performance for two abrasive product formulations in the grinding of three materials is presented. The obtained results can be applied for the development of grinding applications for DTG materials.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This keynote paper aims at analyzing relevant industrial demands for grinding research. The chosen focus is to understand what are the main research challenges in the extensive industrial use of the process. Since the automotive applications are the most important driving forces for grinding development, the paper starts with an analysis on the main trends in more efficient engines and the changes in their components that will affect the grinding performance. A view from 23 machine tool builders is also presented based on a survey made in interviews and during the EMO and IMTS machine tool shows. Case studies received by the STC G members were used to show how research centers and industries are collaborating. A view from the authors and the final conclusions show hot topics for future grinding research. (C) 2009 CIRP.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this work is to study the wheel/workpiece dynamic interactions in high-speed grinding using vitrified CBN wheel and DTG (difficult to grind) work materials. This problem is typical in the grinding of engine valve heads. The influence of tangential force per abrasive grain was investigated as an important control variable for the determination of G ratio. Experiments were carried out to observe the influence of vibrations in the wheel wear. The measurements of acoustic emission (AE) and vibration signals helped in identifying the correlation between the dynamic interactions (produced by forced random excitation) and the wheel wear. The wheel regenerative chatter phenomenon was observed by using the wheel mapping technique. (c) 2008 CIRP.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A rapid and simple method was optimized for determination of Delta(9)-tetrahydrocannabinol (Delta(9)-THC), cannabidiol (CBD), and cannabinol (CBN) contents in cannabis products by gas chromatography with flame-ionization detection (GC-FID), using diazepam as internal standard. All parameters of validation of the method such as linearity, intraassay precision, and limits of detection and quantification of the analytes were satisfactory. Using the described method, cannabinoid contents of 55 cannabis product samples seized in Sao Paulo City, Brazil, in 2006 and 2007 were measured. Delta(9)-THC content in marijuana and hashish samples varied between 0.08% and 5.5%, with an average of 2.5%. The phenotypic ratio showed that the products were able to be designated as ""drug type.""

Relevância:

10.00% 10.00%

Publicador:

Resumo:

mais consumida no país, e proscrita pela Lei n° 11.343 de 23 de agosto de 2006 (chamada de “nova lei de droga”), onde todos os isômeros, sais, éteres e ésteres do ∆9-Tetrahidrocannabinol (THC), princípio ativo, foram proscritos. O método utilizado pela Polícia Civil do Estado do Espírito Santo para a identificação de cannabinóides é o teste colorimétrico, por meio de solução básica de Salt Fast Blue B, o qual apresenta resultados falsos negativos e falsos positivos. A técnica de espectrometria de massas de altíssima resolução e exatidão de massas (ESI(-)FTICR MS), permite detectar os principais cannabinóides na forma de molécula desprotonada, íon [M-H]-. Alguns íons que podem ser identificados são: [CBN - H]- de m/z 309 (CBN = cannabinol); [THC - H]- de m/z 313 (THC = tetrahidrocannabinol) e [CBD - H]- de m/z 313; [CBC - H]- de m/z 327 (CBC = cannabicromeno); [CBEA - H]- de m/z 345 (CBEA = ácido cannabielsóico); [CBNA - H]- de m/z 353 (CBNA = ácido cannabinólico); [THCA - H]- de m/z 357 (THCA = ácido tetrahidrocannabinólico); [8α, 11-Bis-hydroxy-∆9-THC-A - H]- de m/z 389); [∆9-THCA +C2H2O - H]- de m/z 357; e dímeros com m/z de 637, 653, 673, 681, 685 e 717. Foram encontrados adulterantes identificados como [M + N + H]+ : 491; [2M + N + H]+ : 819 e [3M + N + H]+ : 1147, onde M = OTHC (328Da C21H28O3) e N = Nicotina (162Da C10H14N2), além de lidocaína e cocaína. Ainda foram identificados alguns noncannabinóides como Cannflavino A e B e ácidos graxos como palmítico, oleico, linolênico e gama-linolênico nos extratos de sementes de Cannabis. Este estudo tem o objetivo de identificar o perfil químico de amostras de maconha, apreendidas pela Polícia Civil do Estado do Espírito Santo, por ESI(±)-FT-ICR MS.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Esta dissertação tem como objectivo o estudo de um dos grandes problemas da manutenção do Nível de Serviço das vias de comunicação rodoviária e, em especial, da Segurança Rodoviária, que se coloca ao nível das suas acessibilidades, e nas diversas metodologias utilizadas nas vias de aceleração e de desaceleração, ao nível europeu. Neste trabalho, foi coligida a documentação existente em Portugal sobre a introdução e cálculo específico das vias de aceleração e de desaceleração. Seguidamente foi efectuada uma análise deste tema a nível europeu, com base em três países de referência (Espanha, Itália e França), comparando as metodologias respectivas. Por fim, concluída a análise e comparação, são propostas medidas com a finalidade de implementar um conjunto de critérios semelhantes, entre as medidas adoptadas na UE e Portugal.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

UNL - NSBE

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The metabolism of Δ(9)-tetrahydrocannabinol (THC) is relatively complex, and over 80 metabolites have been identified. However, much less is known about the formation and fate of cannabinoid conjugates. Bile excretion is known to be an important route for the elimination of phase II metabolites. A liquid chromatography-tandem mass spectrometry LC-MS/MS procedure for measuring cannabinoids in oral fluid was adapted, validated and applied to 10 bile samples. THC, 11-hydroxy-Δ(9)-tetrahydrocannabinol (11-OH-THC), 11-nor-9-carboxy-Δ(9)-tetrahydrocannabinol (THCCOOH), cannabinol (CBN), cannabidiol (CBD), Δ(9)-tetrahydrocannabinolic acid A (THC-A), 11-nor-9-carboxy-Δ(9)-tetrahydrocannabinol glucuronide (THCCOOH-gluc) and Δ(9)-tetrahydrocannabinol glucuronide (THC-gluc) were determined following solid-phase extraction and LC-MS/MS. High concentrations of THCCOOH-gluc were found in bile samples (range: 139-21,275 ng/mL). Relatively high levels of THCCOOH (7.7-1548 ng/mL) and THC-gluc (38-1366 ng/mL) were also measured. THC-A, the plant precursor of THC, was the only cannabinoid that was not detected. These results show that biliary excretion is an important route of elimination for cannabinoids conjugates and that their enterohepatic recirculation is a significant factor to consider when analyzing blood elimination profiles of cannabinoids. Furthermore, we suggest that the bile is the matrix of choice for the screening of phase II cannabinoid metabolites.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ao examinar a questão do abandono do magistério público na rede de ensino do Estado de São Paulo, este artigo teve como principal objetivo compreender de que modo esse processo é tecido ao longo da vida e da experiência profissional dos professores. O estudo focalizou o período de 1990-1995 e se baseou em dados quantitativos, obtidos na Secretaria Estadual de Educação, a partir dos quais verificou-se, no interregno, um aumento da ordem de 300% nos pedidos de exoneração do magistério, e em dados qualitativos, obtidos de um questionário, enviado a 158 ex-professores da rede pública, e de 16 entrevistas sobre histórias de vida profissional. As análises evidenciam que, além dos baixos salários, as precárias situações, a insatisfação no trabalho e o desprestígio profissional estão entre os fatores que mais contribuem para que os professores deixem a profissão docente. Mostram também que esse processo acontece lentamente, por meio de uma série de mecanismos pessoais e institucionais de que os docentes fazem uso, até que ocorra o abandono definitivo.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A sensitive method was developed for quantifying a wide range of cannabinoids in oral fluid (OF) by liquid chromatography-tandem mass spectrometry (LC-MS/MS). These cannabinoids include a dagger(9)-tetrahydrocannabinol (THC), 11-hydroxy-a dagger(9)-tetrahydrocannabinol (11-OH-THC), 11-nor-9-carboxy-a dagger(9)-tetrahydrocannabinol (THCCOOH), cannabinol (CBN), cannabidiol (CBD), a dagger(9)-tetrahydrocannabinolic acid A (THC-A), 11-nor-9-carboxy-a dagger(9)-tetrahydrocannabinol glucuronide (THCCOOH-gluc), and a dagger(9)-tetrahydrocannabinol glucuronide (THC-gluc). Samples were collected using a Quantisal (TM) device. The advantages of performing a liquid-liquid extraction (LLE) of KCl-saturated OF using heptane/ethyl acetate versus a solid-phase extraction (SPE) using HLB copolymer columns were determined. Chromatographic separation was achieved in 11.5 min on a Kinetex (TM) column packed with 2.6-mu m core-shell particles. Both positive (THC, 11-OH-THC, CBN, and CBD) and negative (THCCOOH, THC-gluc, THCCOOH-gluc, and THC-A) electrospray ionization modes were employed with multiple reaction monitoring using a high-end AB Sciex API 5000 (TM) triple quadrupole LC-MS/MS system. Unlike SPE, LLE failed to extract THC-gluc and THCCOOH-gluc. However, the LLE method was more sensitive for the detection of THCCOOH than the SPE method, wherein the limit of detection (LOD) and limit of quantification (LOQ) decreased from 100 to 50 pg/ml and from 500 to 80 pg/ml, respectively. The two extraction methods were successfully applied to OF samples collected from volunteers before and after they smoked a homemade cannabis joint. High levels of THC were measured soon after smoking, in addition to significant amounts of THC-A. Other cannabinoids were found in low concentrations. Glucuronide conjugate levels were lower than the method's LOD for most samples. Incubation studies suggest that glucuronides could be enzymatically degraded by glucuronidase prior to OF collection