990 resultados para Reactive Control


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Multilevel power converters have been introduced as the solution for high-power high-voltage switching applications where they have well-known advantages. Recently, full back-to-back connected multilevel neutral point diode clamped converters (NPC converter) have been used inhigh-voltage direct current (HVDC) transmission systems. Bipolar-connected back-to-back NPC converters have advantages in long-distance HVDCtransmission systems over the full back-to-back connection, but greater difficulty to balance the dc capacitor voltage divider on both sending and receiving end NPC converters. This study shows that power flow control and dc capacitor voltage balancing are feasible using fast optimum-predictive-based controllers in HVDC systems using bipolar back-to-back-connected five-level NPC multilevel converters. For both converter sides, the control strategytakes in account active and reactive power, which establishes ac grid currents in both ends, and guarantees the balancing of dc bus capacitor voltages inboth NPC converters. Additionally, the semiconductor switching frequency is minimised to reduce switching losses. The performance and robustness of the new fast predictive control strategy, and its capability to solve the DC capacitor voltage balancing problem of bipolar-connected back-to-back NPCconverters are evaluated.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Voltage source multilevel power converter structures are being considered for high power high voltage applications where they have well known advantages. Recently, full back-to-back connected multilevel neutral diode clamped converters (NPC) have been used in high voltage direct current (HVDC) transmission systems. Bipolar back-to-back connection of NPCs have advantages in long distance HVDC transmission systems, but highly increased difficulties to balance the dc capacitor voltage dividers on both sending and receiving end NPCs. This paper proposes a fast optimum-predictive controller to balance the dc capacitor voltages and to control the power flow in a long distance HVDCsystem using bipolar back-to-back connected NPCs. For both converter sides, the control strategy considers active and reactive power to establish ac grid currents on sending and receiving ends, while guaranteeing the balancing of both NPC dc bus capacitor voltages. Furthermore, the fast predictivecontroller minimizes the semiconductor switching frequency to reduce global switching losses. The performance and robustness of the new fast predictive control strategy and the associated dc capacitors voltage balancing are evaluated. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The reactive power management is an important task in future power systems. The control of reactive power allows the increase of distributed energy resources penetration as well as the optimal operation of distribution networks. Currently, the control of reactive power is only controlled in large power units and in high and very high voltage substations. In this paper a reactive power control in smart grids paradigm is proposed, considering the management of distributed energy resources and of the distribution network by an aggregator namely Virtual Power Player (VPP).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents a direct power control (DPC) for three-phase matrix converters operating as unified power flow controllers (UPFCs). Matrix converters (MCs) allow the direct ac/ac power conversion without dc energy storage links; therefore, the MC-based UPFC (MC-UPFC) has reduced volume and cost, reduced capacitor power losses, together with higher reliability. Theoretical principles of direct power control (DPC) based on sliding mode control techniques are established for an MC-UPFC dynamic model including the input filter. As a result, line active and reactive power, together with ac supply reactive power, can be directly controlled by selecting an appropriate matrix converter switching state guaranteeing good steady-state and dynamic responses. Experimental results of DPC controllers for MC-UPFC show decoupled active and reactive power control, zero steady-state tracking error, and fast response times. Compared to an MC-UPFC using active and reactive power linear controllers based on a modified Venturini high-frequency PWM modulator, the experimental results of the advanced DPC-MC guarantee faster responses without overshoot and no steady-state error, presenting no cross-coupling in dynamic and steady-state responses.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper reports on the structural and optical properties of Co-doped TiO2 thin films grown onto (0001)Al2O3 substrates by non-reactive pulsed laser deposition (PLD) using argon as buffer gas. It is shown that by keeping constant the substrate temperature at as low as 310 degrees C and varying only the background gas pressure between 7 Pa and 70 Pa, it is possible to grow either epitaxial rutile or pure anatase thin films, as well as films with a mixture of both polymorphs. The optical band gaps of the films are red shifted in comparison with the values usually reported for undoped TiO2, which is consistent with n-type doping of the TiO2 matrix. Such band gap red shift brings the absorption edge of the Co-doped TiO2 films into the visible region, which might favour their photocatalytic activity. Furthermore, the band gap red shift depends on the films' phase composition, increasing with the increase of the Urbach energy for increasing rutile content. (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective - The study evaluated the effect of a canned sardine supplement in C-reactive protein (CRP) in patients on hemodialysis (HD) and the compliance and adherence to this supplement. Design - This was a quasi-experimental study: Participants with a serum CRP of 5 mg/dL or less volunteered to consume a sardine supplement or were maintained on the usual cheese/ham sandwich supplement. Setting - The study took place in two outpatient dialysis units in Lisbon, Portugal. Patients - The study comprised 63 patients receiving maintenance HD three times per week for at least 6 months and an initial CRP concentration of 5 mg/dL or less. Exclusion criteria included the presence of graft vascular access or history of cancer. Intervention - After a 4-week washout period, the nutritional intervention included a canned sardine sandwich for the case group (n = 31) and a cheese or ham sandwich for the control group (n = 32), to be ingested during each routine HD session, 3 times per week, for 8 weeks. Main outcome measure - Serum levels of high-sensitivity CRP were the outcome measure. Results - Only 65 patients from the invited 186 patients met the inclusion criteria and agreed to eat the sardine sandwich supplement three times per week and were involved in the study. A significant proportion of 48% (n = 31, case group) consumed the sardine sandwich supplement three times per week for 8 weeks, fulfilling the requirements and completing the study. The present investigation showed that a sardine sandwich supplement had no effect on CRP levels among patients on HD. However, when participants were stratified according to tertiles of CRP distribution values at baseline, a reduction in CRP levels was found for those in the higher tertile, being higher for the case group (P = .047). Although diabetic patients were excluded from the analysis (eight in the sardine supplementation group and seven in the control group) a significant CRP reduction was found (P = .034). Conclusion - Although a supplement of low-dose n-3 long-chain polyunsaturated fatty acids had no effect on the plasma high-sensitivity CRP of the supplemented group, a reduction in CRP levels was found when patients were stratified for tertiles of CRP (for the upper tertile) and diabetic status (for nondiabetic patients). These findings need to be further confirmed. This canned sardine supplement was accepted by an important proportion of patients, enhancing diet variety and contributing for a greater n-3 long-chain polyunsaturated fatty acids eicosapentaenoic acid and docosahexaenoic acid intake.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of the present work is to determine the antioxidant capacity (AC) of 27 commercial beers. The AC indicates the degree of protection of a certain organism against oxidative damage provoked by reactive oxygen and nitrogen species. Assays were carried out by the following methods: (i) total radical trapping antioxidant parameter (TRAP); (ii) trolox equivalent antioxidant capacity (TEAC); (iii) trolox equivalent antioxidant capacity (DPPH); (iv) ferric-ion reducing antioxidant parameter (FRAP); (v) cupric reducing antioxidant capacity (CUPRAC); (vi) oxygen radical absorbance capacity (ORAC). Ascorbic acid (AA), gallic acid (GA) and trolox (TR) were used as standards. All beers showed antioxidant power, but a wide range of ACs was observed. The effect of several factors upon these differences was studied. Statistical differences were found between ACs of beers of different colours. ORAC method provided always higher experimental ACs, of significant statistical differences to other assays.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents a new predictive digital control method applied to Matrix Converters (MC) operating as Unified Power Flow Controllers (UPFC). This control method, based on the inverse dynamics model equations of the MC operating as UPFC, just needs to compute the optimal control vector once in each control cycle, in contrast to direct dynamics predictive methods that needs 27 vector calculations. The theoretical principles of the inverse dynamics power flow predictive control of the MC based UPFC with input filter are established. The proposed inverse dynamics predictive power control method is tested using Matlab/Simulink Power Systems toolbox and the obtained results show that the designed power controllers guarantees decoupled active and reactive power control, zero error tracking, fast response times and an overall good dynamic and steady-state response.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents the design and compares the performance of linear, decoupled and direct power controllers (DPC) for three-phase matrix converters operating as unified power flow controllers (UPFC). A simplified steady-state model of the matrix converter-based UPFC fitted with a modified Venturini high-frequency pulse width modulator is first used to design the linear controllers for the transmission line active (P) and reactive (Q) powers. In order to minimize the resulting cross coupling between P and Q power controllers, decoupled linear controllers (DLC) are synthesized using inverse dynamics linearization. DPC are then developed using sliding-mode control techniques, in order to guarantee both robustness and decoupled control. The designed P and Q power controllers are compared using simulations and experimental results. Linear controllers show acceptable steady-state behaviour but still exhibit coupling between P and Q powers in transient operation. DLC are free from cross coupling but are parameter sensitive. Results obtained by DPC show decoupled power control with zero error tracking and faster responses with no overshoot and no steady-state error. All the designed controllers were implemented using the same digital signal processing hardware.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The reactive power management in distribution network with large penetration of distributed energy resources is an important task in future power systems. The control of reactive power allows the inclusion of more distributed recourses and a more efficient operation of distributed network. Currently, the reactive power is only controlled in large power plants and in high and very high voltage substations. In this paper, several reactive power control strategies considering a smart grids paradigm are proposed. In this context, the management of distributed energy resources and of the distribution network by an aggregator, namely Virtual Power Player (VPP), is proposed and implemented in a MAS simulation tool. The proposed methods have been computationally implemented and tested using a 32-bus distribution network with intensive use of distributed resources, mainly the distributed generation based on renewable resources. Results concerning the evaluation of the reactive power management algorithms are also presented and compared.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Most of today’s systems, especially when related to the Web or to multi-agent systems, are not standalone or independent, but are part of a greater ecosystem, where they need to interact with other entities, react to complex changes in the environment, and act both over its own knowledge base and on the external environment itself. Moreover, these systems are clearly not static, but are constantly evolving due to the execution of self updates or external actions. Whenever actions and updates are possible, the need to ensure properties regarding the outcome of performing such actions emerges. Originally purposed in the context of databases, transactions solve this problem by guaranteeing atomicity, consistency, isolation and durability of a special set of actions. However, current transaction solutions fail to guarantee such properties in dynamic environments, since they cannot combine transaction execution with reactive features, or with the execution of actions over domains that the system does not completely control (thus making rolling back a non-viable proposition). In this thesis, we investigate what and how transaction properties can be ensured over these dynamic environments. To achieve this goal, we provide logic-based solutions, based on Transaction Logic, to precisely model and execute transactions in such environments, and where knowledge bases can be defined by arbitrary logic theories.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction Congenital syphilis is an important health problem in Brazil. This study assessed measures aimed at the prevention and control of syphilis in the State of Mato Grosso and its capital, Cuiabá. Methods A descriptive study cross-sectional and of time trends assessing the congenital syphilis was performed in Cuiabá and Mato Grosso between 2001 and 2011. We compared maternal sociodemographic characteristics and health care utilization related to cases of congenital syphilis during the periods from 2001 to 2006 and from 2007 to 2011. We assessed the temporal trends in this disease's incidence using a simple linear regression. Results Between 2001 and 2006 in Mato Grosso, 86.8% of the mothers who had live births with congenital syphilis received prenatal care, 90.6% presented with a nontreponemal test reagent at delivery, 96.2% had no information regarding a treponemal confirmatory test at delivery, and 77.6% received inadequate treatment for syphilis; additionally, 75.8% of their partners were not treated. There was a statistically significant reduction in prenatal visits (p = 0.004) and an increase in the proportion of mothers reactive to nontreponemal tests at delivery (p = 0.031) between the two periods. No other variables were found to differ significantly between the periods. In Cuiabá, we observed a similar distribution of variables. In the state and in the capital, the increasing trend of congenital syphilis was not statistically significant. Conclusions The high incidence of congenital syphilis in Mato Grosso and the low levels of health care indicators for pregnant women with syphilis suggest the need to improve the coverage and quality of prenatal care.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper discusses how object-oriented iuheritance can be re-interpreted if statecharts are used for modelling the dynamic behaviour of an object. The support of inheritance of statecharts allows the improvement of systems' development by easing the reutilization of parts of already developed euccessful systems, aad by promoting the iterative and continuous models' refinement advocated by the operatioaal approach. Statechart is the formalism used within UML to specify reactive state.based behaviours. This paper covers the use of statecharts within the modelling of embedded systems for industrial control applxications, where performance and memory usage are main concerns.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In addition to numerous immune factors, C-reactive protein (CRP) and nitric oxide (NO) are believed to be molecules of malaria immunopathology. The objective of this study was to detect CRP and NO inductions by agglutination latex test and Griess microassay respectively in both control and malaria groups from endemic areas of Iran, including Southeastern (SE) (Sistan & Balouchestan, Hormozgan, Kerman) and Northwestern (NW) provinces (Ardabil). The results indicated that CRP and NO are produced in all malaria endemic areas of Iran. In addition, more CRP and NO positive cases were observed amongst malaria patients in comparison with those in control group. A variable co-association of CRP/NO production were detected between control and malaria groups, which depended upon the malaria endemic areas and the type of plasmodia infection. The percentage of CRP/NO positive cases was observed to be lower in NW compare to SE region, which may be due to the different type of plasmodium in the NW (Plasmodium vivax) with SE area (P. vivax, Plasmodium falciparum, mixed infection). The fluctuations in CRP/NO induction may be consistent with genetic background of patients. Although, CRP/NO may play important role in malaria, their actual function and interaction in clinical forms of disease remains unclear.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

ABSTRACT¦Naturally acquired tumor-specific T-cells can be detected in most advanced cancer patients.¦Yet, they often fail to control or eliminate the disease, in contrast to many virus-specific CD8¦T lymphocytes. Therapeutic vaccines aim at inducing and boosting specific T-cells mediated¦immunity to reduce tumor burden. The properties of CD8 T-cells required for protection from¦infectious disease and cancer are only partially characterized.¦The objectives of this study were to assess effector functions, stage of differentiation and¦clonotype selection of tumor-reactive T lymphocytes following peptide vaccination in¦melanoma patients over time. Results were compared to protective viral-specific T-cell¦responses found in healthy individuals. We also characterized dominant versus low/non¦dominant T-cell clonotypes with the aim to further understand the in vivo function of each set¦of frequency-based specific T-cells.¦Here we developed and applied a novel approach for molecular and functional analysis of¦single T lymphocytes ex vivo. T-cell receptor (TCR) clonotype mapping revealed rapid¦selection and expansion of co-dominant T-cell clonotypes, which made up the majority of the¦highly differentiated "effector" T-cells, but only 25% of the less differentiated "effectormemory"¦cells, mostly composed of non-dominant clonotypes. Moreover, we show that¦advanced effector cell differentiation was indeed clonotype-dependent. Surprisingly, however,¦the acquisition of effector functions (cytokine production, killing) was clonotype-independent.¦Vaccination of melanoma patients with native peptide induced competent effector function in¦both dominant and non-dominant clonotypes, suggesting that most if not all clonotypes¦participating in a T-cell response have the potential to develop equal functional competence.¦In contrast, many T-cells remained poorly functional after vaccination with analog peptide,¦despite similar clonotype-dependent differentiation. Our findings show that the type of¦peptide vaccine has a critical influence on the selection and functional activation of the¦clonotypic T-cell repertoire. They also show that systematic assessment of individual T-cells¦identifies the cellular basis of immune responses, contributing to the rational development of¦vaccines.