998 resultados para Radiographic imaging


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim Non-radiographic axial spondyloarthritis (nr-axSpA) is axial inflammatory arthritis where plain radiographic damage is not evident. An unknown proportion of these patients will progress to ankylosing spondylitis (AS). The increasing recognition of nr-axSpA has been greatly assisted by the widespread use of magnetic resonance imaging. The aim of this article was to construct a set of consensus statements based on a literature review to guide investigation and promote best management of nr-axSpA. Methods A literature review using Medline was conducted covering the major investigation modalities and treatment options available. A group of rheumatologists and a radiologist with expertise in investigation and management of SpA reviewed the literature and formulated a set of consensus statements. The Grade system encompassing the level of evidence and strength of recommendation was used. The opinion of a patient with nr-axSpA and a nurse experienced in the care of SpA patients was also sought and included. Results The literature review found few studies specifically addressing nr-axSpA, or if these patients were included, their results were often not separately reported. Fourteen consensus statements covering investigation and management of nr-axSpA were formulated. The level of agreement was high and ranged from 8.1 to 9.8. Treatment recommendations vary little with established AS, but this is primarily due to the lack of available evidence on the specific treatment of nr-axSpA. Conclusion The consensus statements aim to improve the diagnosis and management of nr-axSpA. We aim to raise awareness of this condition by the public and doctors and promote appropriate investigation and management.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Undergraduate Medical Imaging (MI)students at QUT attend their first clinical placement towards the end of semester two. Students undertake two (pre)clinical skills development units – one theory and one practical. Students gain good contextual and theoretical knowledge during these units via a blended learning model with multiple learning methods employed. Students attend theory lectures, practical sessions, tutorial sessions in both a simulated and virtual environment and also attend pre-clinical scenario based tutorial sessions. The aim of this project is to evaluate the use of blended learning in the context of 1st year Medical Imaging Radiographic Technique and its effectiveness in preparing students for their first clinical experience. It is hoped that the multiple teaching methods employed within the pre-clinical training unit at QUT builds students clinical skills prior to the real situation. A quantitative approach will be taken, evaluating via pre and post clinical placement surveys. This data will be correlated with data gained in the previous year on the effectiveness of this training approach prior to clinical placement. In 2014 59 students were surveyed prior to their clinical placement demonstrated positive benefits of using a variety of learning tools to enhance their learning. 98.31%(n=58)of students agreed or strongly agreed that the theory lectures were a useful tool to enhance their learning. This was followed closely by 97% (n=57) of the students realising the value of performing role-play simulation prior to clinical placement. Tutorial engagement was considered useful for 93.22% (n=55) whilst 88.14% (n=52) reasoned that the x-raying of phantoms in the simulated radiographic laboratory was beneficial. Self-directed learning yielded 86.44% (n=51). The virtual reality simulation software was valuable for 72.41% (n=42) of the students. Of the 4 students that disagreed or strongly disagreed with the usefulness of any tool they strongly agreed to the usefulness of a minimum of one other learning tool. The impact of the blended learning model to meet diverse student needs continues to be positive with students engaging in most offerings. Students largely prefer pre -clinical scenario based practical and tutorial sessions where 'real-world’ situations are discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study was carried out to investigate whether the electronic portal imaging (EPI) acquisition process could be optimized, and as a result tolerance and action levels be set for the PIPSPro QC-3V phantom image quality assessment. The aim of the optimization process was to reduce the dose delivered to the patient while maintaining a clinically acceptable image quality. This is of interest when images are acquired in addition to the planned patient treatment, rather than images being acquired using the treatment field during a patient's treatment. A series of phantoms were used to assess image quality for different acquisition settings relative to the baseline values obtained following acceptance testing. Eight Varian aS500 EPID systems on four matched Varian 600C/D linacs and four matched Varian 2100C/D linacs were compared for consistency of performance and images were acquired at the four main orthogonal gantry angles. Images were acquired using a 6 MV beam operating at 100 MU min(-1) and the low-dose acquisition mode. Doses used in the comparison were measured using a Farmer ionization chamber placed at d(max) in solid water. The results demonstrated that the number of reset frames did not have any influence on the image contrast, but the number of frame averages did. The expected increase in noise with corresponding decrease in contrast was also observed when reducing the number of frame averages. The optimal settings for the low-dose acquisition mode with respect to image quality and dose were found to be one reset frame and three frame averages. All patients at the Northern Ireland Cancer Centre are now imaged using one reset frame and three frame averages in the 6 MV 100 MU min(-1) low-dose acquisition mode. Routine EPID QC contrast tolerance (+/-10) and action (+/-20) levels using the PIPSPro phantom based around expected values of 190 (Varian 600C/D) and 225 (Varian 2100C/D) have been introduced. The dose at dmax from electronic portal imaging has been reduced by approximately 28%, and while the image quality has been reduced, the images produced are still clinically acceptable.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Esta tese pretende contribuir para o estudo e análise dos factores relacionados com as técnicas de aquisição de imagens radiológicas digitais, a qualidade diagnóstica e a gestão da dose de radiação em sistema de radiologia digital. A metodologia encontra-se organizada em duas componentes. A componente observacional, baseada num desenho do estudo de natureza retrospectiva e transversal. Os dados recolhidos a partir de sistemas CR e DR permitiram a avaliação dos parâmetros técnicos de exposição utilizados em radiologia digital, a avaliação da dose absorvida e o índice de exposição no detector. No contexto desta classificação metodológica (retrospectiva e transversal), também foi possível desenvolver estudos da qualidade diagnóstica em sistemas digitais: estudos de observadores a partir de imagens arquivadas no sistema PACS. A componente experimental da tese baseou-se na realização de experiências em fantomas para avaliar a relação entre dose e qualidade de imagem. As experiências efectuadas permitiram caracterizar as propriedades físicas dos sistemas de radiologia digital, através da manipulação das variáveis relacionadas com os parâmetros de exposição e a avaliação da influência destas na dose e na qualidade da imagem. Utilizando um fantoma contrastedetalhe, fantomas antropomórficos e um fantoma de osso animal, foi possível objectivar medidas de quantificação da qualidade diagnóstica e medidas de detectabilidade de objectos. Da investigação efectuada, foi possível salientar algumas conclusões. As medidas quantitativas referentes à performance dos detectores são a base do processo de optimização, permitindo a medição e a determinação dos parâmetros físicos dos sistemas de radiologia digital. Os parâmetros de exposição utilizados na prática clínica mostram que a prática não está em conformidade com o referencial Europeu. Verifica-se a necessidade de avaliar, melhorar e implementar um padrão de referência para o processo de optimização, através de novos referenciais de boa prática ajustados aos sistemas digitais. Os parâmetros de exposição influenciam a dose no paciente, mas a percepção da qualidade de imagem digital não parece afectada com a variação da exposição. Os estudos que se realizaram envolvendo tanto imagens de fantomas como imagens de pacientes mostram que a sobreexposição é um risco potencial em radiologia digital. A avaliação da qualidade diagnóstica das imagens mostrou que com a variação da exposição não se observou degradação substancial da qualidade das imagens quando a redução de dose é efectuada. Propõe-se o estudo e a implementação de novos níveis de referência de diagnóstico ajustados aos sistemas de radiologia digital. Como contributo da tese, é proposto um modelo (STDI) para a optimização de sistemas de radiologia digital.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives The purpose of this study was to evaluate the effectiveness of the acellular dermal matrix (ADM) as a membrane for guided bone regeneration (GBR), in comparison with a bioabsorbable membrane. Material and methods In seven dogs, the mandibular pre-molars were extracted. After 8 weeks, one bone defect was surgically created bilaterally and the GBR was performed. Each side was randomly assigned to the control group (CG: bioabsorbable membrane made of glycolide and lactide copolymer) or the test group (TG: ADM as a membrane). Immediately following GBR, standardized digital X-ray radiographs were taken, and were repeated at 8 and 16 weeks post-operatively. Before the GBR and euthanasia, clinical measurements of the width and thickness of the keratinized tissue (WKT and TKT, respectively) were performed. One animal was excluded from the study due to complications in the TG during wound healing; therefore, six dogs remained in the sample. The dogs were sacrificed 16 weeks following GBR, and a histomorphometric analysis was performed. Area measurements of new tissue and new bone, and linear measurements of bone height were performed. Results Post-operative healing of the CG was uneventful. In the TG membrane was exposed in two animals, and one of them was excluded from the sample. There were no statistically significant differences between the groups for any histomorphometric measurement. Clinically, both groups showed an increase in the TKT and a reduction in the WKT. Radiographically, an image suggestive of new bone formation could be observed in both groups at 8 and 16 weeks following GBR. Conclusion ADM acted as a barrier in GBR, with clinical, radiographic and histomorphometric results similar to those obtained with the bioabsorbable membrane. To cite this article:Borges GJ, Novaes AB Jr, de Moraes Grisi MF, Palioto DB, Taba M Jr, de Souza SLS. Acellular dermal matrix as a barrier in guided bone regeneration: a clinical, radiographic and histomorphometric study in dogs.Clin. Oral Impl. Res. 20, 2009; 1105-1115.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Doria, R.G.S.; Canola, P.A.; Freitas, S.H. & Canola, J.C. [Equine chronic proliferative synovitis (villonodular synovitis): clinical, radiographic and ultrasonographic aspects: Relate of case.] Sinovite proliferativa cronica (sinovite vilonodular) em equino: aspectos clinicos, radiograficos e ultra-sonograficos: Relato de caso. Revista Brasileira de Medicina Veterinciria 30(3):157-161, 2008. Departamento de Cirurgia, Faculdade de Medicina Veterinaria, Universidade de Cuiaba, UNIC, Av. Antartica 788, Casa 26, Residencial Villas Boas, Ribeirao da Ponte, Cuiaba, MT 78040-500. Brasil. E-mail: redoria@uol.com.brThe development of intracapsullar masses at the dorsal aspect of the metacarpofalangeal joint for a period of several months is commonly secondary to the chronic synovitis. Although it is known as villonodular synovitis in horses probably is better to refer it as chronic proliferative synovitis. The most common causes are the non-treated osteocondral fractures of the dorsal portion of the proximal phalanx. In addition, the development of villonodular masses follows the degenerative process in the joint. A case of a lame animal is reported at the present study. The correct diagnosis and the adequate therapeutic propositions were given based on the clinical examination, therapeutic local-anesthetic test and radioghaphic and ultrasonographic imaging exams. The development of a criterious identification of this disease must be based on clinical findings, radiographic and ultrasonographic exams which assume fundamental importance to the treatment and prognostic. The aim of this study is to describe the clinical, radiographic and ultrasonographic findings' allowing the identification and diagnosis of chronic proliferative synovitis at the thoracic metacarpofalangeal joint in the horse.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Accurate early diagnosis of lung metastases is important for establishing therapeutic measures. Therefore, the present study aimed to compare survey thoracic radiographs and computerized tomography (CT) scans to specifically identify lung metastases in female dogs with mammary tumors.Methods: Twenty-one female dogs, weighing 3 to 34 kg and aged from 5 years to 14 years and 10 months, with mammary tumors were studied. In all dogs before the imaging examinations, fine-needle aspiration cytology of the mammary tumors was performed to confirm the diagnosis. Three-view thoracic radiographs were accomplished: right lateral, left lateral and ventrodorsal views. Sequential transverse images of the thorax were acquired on a spiral Scanner, before and after intravenous bolus injection of nonionic iodine contrast. Soft-tissue and lung windows were applied. All the mammary tumors were surgically removed and examined histologically.Results: The correlation between the cytological and histological results regarding presence of malignancy was observed in only 17 cases. In radiographic examinations, no dog displayed signs of lung metastases or thorax chest lesions. CT detected lung metastasis in two cases, while small areas of lung atelectasis located peripherally were found in 28.57% of the dogs.Conclusion: In this study population, spiral CT showed higher sensitivity than chest radiographies to detect lung metastasis; this indicates that CT should be performed on all female dogs with malignant mammary tumors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: To survey the current radiographic prescriptions in dental implant assessment amongst dentists in Brazil.Methods: Sixty-nine dentists were interviewed during a dental implant meeting by two calibrated graduate students, using a 19-question questionnaire, considering imaging modality options both for pre-operative implant site assessment and for follow-up, particularly with respect to cost, patient radiation dose, and broad coverage of facial bones and teeth. Epi-Info 6.04 software was used to analyse the database file.Results: Approximately 63.8% of the dentists prescribed only panoramic radiography for dental implant assessment and 28.9% ordered panoramic radiography plus periapical radiography and/or conventional tomography and/or computed tomography (CT). Only 7.2% of the dentists ordered conventional tomography or CT as a single examination, although 10.1% ordered it in combination with other imaging modalities. The main reasons given for prescribing panoramic radiography were broad coverage and cost (86.4%).Conclusions: This study has shown that most of the dentists in this study prescribe panoramic radiographs in dental implant assessment based on broad coverage and cost. They are not following the American Academy of Oral and Maxillofacial Radiology recommendations regarding cross-sectional imaging.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An 8-month-old Lhasa Apso female dog was referred to the Veterinary Hospital, FMVZ, Unesp, Botucatu Campus, with suspected congenital renal disorder. Ultrasound images revealed higher renal echogenicity, loss of corticomedullary demarcation and diverticular mineralization on the right kidney. The mucosal lining of the stomach was hyperechoic and radiographic examination demonstrated mineralization of wall and folds, which is consistent with uremic gastropathy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Tetralogy of Fallot is a complex cardiac malformation characterized by four anatomical defects: pulmonary valve stenosis, right ventricular hypertrophy, interventricular septal defect and aortic dextroposition. Imaging techniques are useful in the diagnosis of this disease, such as radiography for screening and Doppler echocardiography for a definitive diagnosis. Our objective is to report the radiographic and Doppler echocardiographic aspects of a tetralogy of Fallot case in a 10 month-old Border Collie dog.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Lymphomas are malignant neoplasms resulting from clonal proliferations of lymphocytes, originated from lymphoid organs, but can develop in any organ by the migration of lymphocytes to the organ's tissue. Lymphoma constitutes one of the most common neoplasms in cats. Imaging techniques like radiology, ultrasound and tomography may help in diagnosing and classifying lymphomas. Our objective is to report the radiographic and tomographic characteristics of a mediastinal lymphoma in a cat, which occupied a large thoracic and abdominal area and infiltrated into the medullary canal causing acute paraparesis. The tomographic exam was essential for identifying the mass, its extension and its location, besides identifying how compromised the adjacent structures were, but the histopathological examination was crucial to diagnose the nature of the lesion.