988 resultados para Radiographic Image Enhancement


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Critical limb ischemia in diabetic patients is associated with high rates of morbidity and mortality. Suboptimal responses to the available medical and surgical treatments are common in these patients, who also demonstrate limited vascular homeostasis. Neovasculogenesis induced by stem cell therapy could be a useful approach for these patients. Neovasculogenesis and clinical improvement were compared at baseline and at 3 and 12 months after autologous bone marrow-derived mononuclear cell (BMMNC) transplantation in diabetic patients with peripheral artery disease. We conducted a prospective study to evaluate the safety and efficacy of intra-arterial administration of autologous BMMNCs (100-400 × 10(6) cells) in 20 diabetic patients with severe below-the-knee arterial ischemia. Although the time course of clinical effects differed among patients, after 12 months of follow-up all patients presented a notable improvement in the Rutherford-Becker classification, the University of Texas diabetic wound scales, and the Ankle-Brachial Index in the target limb. The clinical outcome was consistent with neovasculogenesis, which was assessed at 3 months by digital subtraction angiography and quantified by MetaMorph software. Unfortunately, local cell therapy in the target limb had no beneficial effect on the high mortality rate in these patients. In diabetic patients with critical limb ischemia, intra-arterial perfusion of BMMNCs is a safe procedure that generates a significant increase in the vascular network in ischemic areas and promotes remarkable clinical improvement.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Four standard radiation qualities (from RQA 3 to RQA 9) were used to compare the imaging performance of a computed radiography (CR) system (general purpose and high resolution phosphor plates of a Kodak CR 9000 system), a selenium-based direct flat panel detector (Kodak Direct View DR 9000), and a conventional screen-film system (Kodak T-MAT L/RA film with a 3M Trimax Regular screen of speed 400) in conventional radiography. Reference exposure levels were chosen according to the manufacturer's recommendations to be representative of clinical practice (exposure index of 1700 for digital systems and a film optical density of 1.4). With the exception of the RQA 3 beam quality, the exposure levels needed to produce a mean digital signal of 1700 were higher than those needed to obtain a mean film optical density of 1.4. In spite of intense developments in the field of digital detectors, screen-film systems are still very efficient detectors for most of the beam qualities used in radiology. An important outcome of this study is the behavior of the detective quantum efficiency of the digital radiography (DR) system as a function of beam energy. The practice of users to increase beam energy when switching from a screen-film system to a CR system, in order to improve the compromise between patient dose and image quality, might not be appropriate when switching from screen-film to selenium-based DR systems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In our recent paper by Monnin et al. [Med. Phys. 33, 411-420 (2006)], an objective analysis of the relative performance of a computed radiography (CR) system using both standard single-side (ST-VI) and prototype dual-side read (ST-BD) plates was reported. The presampled modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE) for the systems were determined at three different beam qualities representative of paediatric chest radiography, at an entrance detector air kerma of 5 microGy. Experiments demonstrated that, compared to the standard single-side read system, the MTF for the dual-side read system was slightly reduced, but a significant decrease in image noise resulted in a marked increase in DQE (+40%) in the low spatial frequency range. However, the DQE improvement for the ST-BD plate decreased with increasing spatial frequency, and, at spatial frequencies above 2.2 mm(-1), the DQE of the dual-side read system was lower than that of the single-side one.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: The purpose of this study was to adapt and improve a minimally invasive two-step postmortem angiographic technique for use on human cadavers. Detailed mapping of the entire vascular system is almost impossible with conventional autopsy tools. The technique described should be valuable in the diagnosis of vascular abnormalities. MATERIALS AND METHODS: Postmortem perfusion with an oily liquid is established with a circulation machine. An oily contrast agent is introduced as a bolus injection, and radiographic imaging is performed. In this pilot study, the upper or lower extremities of four human cadavers were perfused. In two cases, the vascular system of a lower extremity was visualized with anterograde perfusion of the arteries. In the other two cases, in which the suspected cause of death was drug intoxication, the veins of an upper extremity were visualized with retrograde perfusion of the venous system. RESULTS: In each case, the vascular system was visualized up to the level of the small supplying and draining vessels. In three of the four cases, vascular abnormalities were found. In one instance, a venous injection mark engendered by the self-administration of drugs was rendered visible by exudation of the contrast agent. In the other two cases, occlusion of the arteries and veins was apparent. CONCLUSION: The method described is readily applicable to human cadavers. After establishment of postmortem perfusion with paraffin oil and injection of the oily contrast agent, the vascular system can be investigated in detail and vascular abnormalities rendered visible.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to evaluate helical CT angiography in the assessment of occlusive arterial disease of abdominal aorta and the lower extremities. Sixteen patients underwent both transcatheter angiography and helical CT. Helical CT was inconclusive in 6.2% of segments whereas angiography was inconclusive in 5%. The overall sensitivity of helical CT was 91% and specificity 93%. Segmental analysis found a sensitivity of 43% in infrapopliteal arteries, and a specificity of 86%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O objetivo deste estudo foi comparar as decisões de tratamento restaurador de superfícies oclusais, sem cavitação, quando realizadas através dos aspectos clínicos e radiográficos, convencional e digitalizado. Foram examinados, 33 sítios das superfícies oclusais de 30 molares permanentes extraídos, com e sem pigmentação. O plano de tratamento para cada região foi realizado por 5 cirurgiões-dentistas, professores universitários, utilizando dois tipos de exames: exame visual de fotografias e radiografia interproximal convencional (IV + RXC); e exame visual de fotografias e radiografia digitalizada (IV + DIGORA). O padrão de validação para os planos de tratamento foi realizado através do aspecto histológico. A sensibilidade em determinar a não-necessidade de tratamento restaurador foi, em média, tanto para a IV + RXC quanto para a IV + DIGORA, de 0,23. A especificidade foi, em média, de 0,83 e 0,86, para a IV + RXC e IV + DIGORA, respectivamente. Quando comparou-se os planos de tratamento intra-examinadores, não foi encontrada diferença estatisticamente significante à nível de 5%. Baseado nestes dados, pode-se concluir que os métodos radiográficos, convencional e digitalizado, não demonstraram diferenças na efetividade da determinação do plano de tratamento de superfícies oclusais sem cavitação.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to assess positive end-expiratory pressure (PEEP)-induced lung overdistension and alveolar recruitment in six patients with acute lung injury (ALI) using a computed tomographic (CT) scan method. Lung overdistension was first determined in six healthy volunteers in whom CT sections were obtained at FRC and at TLC with a positive airway pressure of 30 cm H2O. In patients, lung volumes were quantified by the analysis of the frequency distribution of CT numbers on the entire lung at zero end-expiratory pressure (ZEEP) and PEEP. In healthy volunteers at FRC, the distribution of the density histograms was monophasic with a peak at -791 ± 12 Hounsfield units (HU). The lowest CT number observed was -912 HU. At TLC, lung volume increased by 79 ± 35% and the peak CT number decreased to -886 ± 26 HU. More than 70% of the increase in lung volume was located below -900 HU, suggesting that this value can be considered as the threshold separating normal aeration from overdistension. In patients with ALI, at ZEEP the distribution of density histograms was either monophasic (n = 3) or biphasic (n = 3). The mean CT number was -319 ± 34 HU. At PEEP 13 ± 3 cm H2O, lung volume increased by 47 ± 19% whereas mean CT number decreased to -538 ± 171 HU. PEEP induced a mean alveolar recruitment of 320 ± 160 ml and a mean lung overdistension of 238 ± 320 ml. In conclusion, overdistended lung parenchyma of healthy volunteers is characterized by a CT number below -900 HU. This threshold can be used in patients with ALI for differentiating PEEP-induced alveolar recruitment from lung overdistension.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background. Intravenous injection of contrast material is routinely performed in order to differentiate nonaerated lung parenchyma from pleural effusion in critically ill patients undergoing thoracic computed tomography (CT). The aim of the present study was to evaluate the effects of contrast material on CT measurement of lung volumes in 14 patients with acute lung injury. Method. A spiral thoracic CT scan, consisting of contiguous axial sections of 10 mm thickness, was performed from the apex to the diaphragm at end-expiration both before and 30 s (group 1; n=7) or 15 min (group 2; n=7) after injection of 80 ml contrast material. Volumes of gas and tissue, and volumic distribution of CT attenuations were measured before and after injection using specially designed software (Lungview®; Institut National des Télécommunications, Evry, France). The maximal artifactual increase in lung tissue resulting from a hypothetical leakage within the lung of the 80 ml contrast material was calculated. Results. Injection of contrast material significantly increased the apparent volume of lung tissue by 83 ± 57 ml in group 1 and 102 ± 80 ml in group 2, whereas the corresponding maximal artifactual increases in lung tissue were 42 ± 52 ml and 31 ± 18 ml. Conclusion. Because systematic injection of contrast material increases the amount of extravascular lung water in patients with acute lung injury, it seems prudent to avoid this procedure in critically ill patients undergoing a thoracic CT scan and to reserve its use for specific indications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to evaluate the diagnostic agreement of conventional panoramic radiographs and their inverted scanned images in the detection of the mandibular canal and mental foramen. A total of 77 panoramic radiographs obtained from the files of totally edentulous patients were used. Digitization was done by means of a scanner with brightness and contrast adjustment, as well as image inversion. The extension of mandibular canal was divided into anterior, middle, and posterior regions, and the presence of a radiopaque line that characterized the mandibular canal was classified according to a 5-point confidence scale. The mental foramen was classified in 4 types: continuous, separated, diffuse, and unidentified. Both conventional and inverted scanned panoramic radiographs were evaluated by 3 calibrated implantologists at 2 distinct moments with a minimum interval of 10 days between them. Intraexaminer agreement was evaluated by Kappa statistics by point and by 95% confidence interval. Because the intraexaminer level of agreement was low, interexaminer agreements could not be carried out. The results showed a substantial (in 2 situations), moderate (in 16 situations), and fair (in 18 situations) intraexaminer agreement for mandibular canal and a substantial (in 1 situation), fair (in 1 situation), and moderate (in 10 situations) intraeaminer agreement for mental foramen. There were no statistically significant differences in most instances. In conclusion, the diagnostic agreement of conventional and inverted scanned panoramic radiographs for detection of mandibular canal and mental foramen was low.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The influence of the type of rotary cutting instrument on bone repair after osteotomy in swine jaw, was evaluated using digital and densitometric radiographic examinations, at controlled times. Two cross-sectional dissections were made through the base of the right jaw, one using a high speed rotary instrument and the other using low speed, both with liquid cooling. After established periods the animals were sacrificed and their jaws removed for direct and indirect digital radiographic and densitometric studies using the CROMOX, DIGORA and ODR systems. In the initial periods (7 and 28 days) the bone density was higher in osteotomy areas performed with high rotation speeds, and in the final periods (60 and 90 days) the bone density was higher in the osteotomies performed with low rotation, indicating a better final bone repair with the use of low rotation. The qualitative analysis of the repair process was made by the ODR system which obtained three-dimensional and coloured digital images, which enable the bone thickness to be measured using an aluminium wedge. This showed that by twenty-eight days the bone repair was already apparently complete. © 2010 SECOM.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Odontologia - FOA

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A imagem digital no formato DICOM requer grande espaço para armazenamento, dificultando o arquivamento e transmissão da imagem via internet, sendo necessária, muitas vezes, a compressão das imagens por meio de formatos de arquivo como o JPEG. O objetivo neste estudo foi avaliar a influência dos formatos DICOM e JPEG, nos Fatores de Qualidade 100, 80 e 60, na reprodutibilidade intra e interexaminador na marcação de pontos cefalométricos em Telerradiografias digitais em Norma Frontal. A amostra consistiu de 120 imagens digitais de Telerradiografias em Norma Frontal, obtidas de 30 indivíduos. As 30 imagens originais, em formato DICOM, posteriormente, foram convertidas para o formato JPEG, nos Fatores de Qualidade 100, 80 e 60. Após cegar e randomizar a amostra, três ortodontistas calibrados marcaram os 18 pontos cefalométricos em cada imagem utilizando um programa de cefalometria computadorizada, que registra as medidas dos pontos cefalométricos em um sistema de coordenadas cartesianas X e Y. Nos resultados, os testes estatísticos de correlações intraclasses e análise de variância (ANOVA) apresentaram concordância de reprodutibilidade dos pontos cefalométricos em Telerradiografias digitais em Norma Frontal, tanto intra como interexaminador, com exceção dos pontos ZL, ZR, AZ, JR, NC, CN na coordenada Y e A6 na coordenada X, independentemente dos formatos de arquivo. Em conclusão, os formatos de arquivo DICOM e JPEG, nos Fatores de Qualidade 100, 80 e 60, não afetaram a reprodutibilidade intra e interexaminador na marcação dos pontos cefalométricos.(AU)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A imagem digital no formato DICOM requer grande espaço para armazenamento, dificultando o arquivamento e transmissão da imagem via internet, sendo necessária, muitas vezes, a compressão das imagens por meio de formatos de arquivo como o JPEG. O objetivo neste estudo foi avaliar a influência dos formatos DICOM e JPEG, nos Fatores de Qualidade 100, 80 e 60, na reprodutibilidade intra e interexaminador na marcação de pontos cefalométricos em Telerradiografias digitais em Norma Frontal. A amostra consistiu de 120 imagens digitais de Telerradiografias em Norma Frontal, obtidas de 30 indivíduos. As 30 imagens originais, em formato DICOM, posteriormente, foram convertidas para o formato JPEG, nos Fatores de Qualidade 100, 80 e 60. Após cegar e randomizar a amostra, três ortodontistas calibrados marcaram os 18 pontos cefalométricos em cada imagem utilizando um programa de cefalometria computadorizada, que registra as medidas dos pontos cefalométricos em um sistema de coordenadas cartesianas X e Y. Nos resultados, os testes estatísticos de correlações intraclasses e análise de variância (ANOVA) apresentaram concordância de reprodutibilidade dos pontos cefalométricos em Telerradiografias digitais em Norma Frontal, tanto intra como interexaminador, com exceção dos pontos ZL, ZR, AZ, JR, NC, CN na coordenada Y e A6 na coordenada X, independentemente dos formatos de arquivo. Em conclusão, os formatos de arquivo DICOM e JPEG, nos Fatores de Qualidade 100, 80 e 60, não afetaram a reprodutibilidade intra e interexaminador na marcação dos pontos cefalométricos.(AU)