243 resultados para Radiofrequency


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Acute pneumothorax is a frequent complication after percutaneous pulmonary radiofrequency (RF) ablation. In this study we present three cases showing delayed development of pneumothorax after pulmonary RF ablation in 34 patients. Our purpose is to draw attention to this delayed complication and to propose a possible approach to avoid this major complication. These three cases occurred subsequent to 44 CT-guided pulmonary RF ablation procedures (6.8%) using either internally cooled or multitined expandable RF electrodes. In two patients, the pneumothorax, being initially absent at the end of the intervention, developed without symptoms. One of these patients required chest drain placement 32 h after RF ablation, and in the second patient therapy remained conservative. In the third patient, a slight pneumothorax at the end of the intervention gradually increased and led into tension pneumothorax 5 days after ablation procedure. Underlying bronchopleural fistula along the coagulated former electrode track was diagnosed in two patients. In conclusion, delayed development of pneumothorax after pulmonary RF ablation can occur and is probably due to underlying bronchopleural fistula, potentially leading to tension pneumothorax. Patients and interventionalists should be prepared for delayed onset of this complication, and extensive track ablation following pulmonary RF ablation should be avoided.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Contact force (CF) is an important determinant of lesion formation for atrial endocardial radiofrequency ablation. There are minimal published data on CF and ventricular lesion formation. We studied the impact of CF on lesion formation using an ovine model both endocardially and epicardially. METHODS AND RESULTS Twenty sheep received 160 epicardial and 160 endocardial ventricular radiofrequency applications using either a 3.5-mm irrigated-tip catheter (Thermocool, Biosense-Webster, n=160) or a 3.5 irrigated-tip catheter with CF assessment (Tacticath, Endosense, n=160), via percutaneous access. Power was delivered at 30 watts for 60 seconds, when either catheter/tissue contact was felt to be good or when CF>10 g with Tacticath. After completion of all lesions, acute dimensions were taken at pathology. Identifiable lesion formation from radiofrequency application was improved with the aid of CF information, from 78% to 98% on the endocardium (P<0.001) and from 90% to 100% on the epicardium (P=0.02). The mean total force was greater on the endocardium (39±18 g versus 21±14 g for the epicardium; P<0.001) mainly because of axial force. Despite the force-time integral being greater endocardially, epicardial lesions were larger (231±182 mm(3) versus 209±131 mm(3); P=0.02) probably because of the absence of the heat sink effect of the circulating blood and covered a greater area (41±27 mm(2) versus 29±17 mm(2); P=0.03) because of catheter orientation. CONCLUSIONS In the absence of CF feedback, 22% of endocardial radiofrequency applications that are thought to have good contact did not result in lesion formation. Epicardial ablation is associated with larger lesions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the study was to review the clinical and electrophysiological characteristics and results of radiofrequency catheter ablation in patients with multiple accessory pathways to compare them with those of patients with single accessory pathways. Electrophysiological study and radiofrequency catheter ablation were performed in 1010 consecutive cases with Wolff Parkinson White Syndrome. Presence of multiple accessory pathways was documented in 31 patients (3.1%); 30 had two, and 1 had three accessory pathways. Of the 63 accessory pathways, 42 were manifest and 21 concealed. Nine patients had Ebstein's anomaly associated with atrioventricular bypass tracts. The most common combination was right posteroseptal with right free wall bypass tracts (15 patients with 30 accessory pathways). Fifty-one of the sixty-three accessory pathways (81%) were ablated successfully without complications. The duration of the procedure was 100 +/- 58 min and the fluoroscopic time 40 +/- 17 min. A follow up of 5 +/- 3 years after ablation, demonstrated recurrences of six accessory pathways (9.5%). In conclusion, patients with multiple accessory pathways can be treated by radiofrequency ablation in only one session with a high success rate although slightly less than that in patients with a single accessory pathway (81% vs 93%, P<0.01).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the case of a patient in whom successful radiofrequency catheter ablation of an idiopathic ventricular tachycardia (VT) originating in the main stem of the pulmonary artery was performed. After successful ablation of the index arrhythmia, which was an idiopathic right ventricular outflow tract VT, a second VT with a different QRS morphology was reproducibly induced. Mapping of the second VT revealed the presence of myocardium approximately 2 cm above the pulmonary valve. Application of radiofrequency energy at this site resulted in termination and noninducibility of this VT. After 6-month follow-up, the patient remained free from VT recurrences.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND The objective of this study was to assess the incidence and impact of asymptomatic arrhythmia in patients with highly symptomatic atrial fibrillation (AF) who qualified for radiofrequency (RF) catheter ablation. METHODS AND RESULTS In this prospective study, 114 patients with at least 3 documented AF episodes together with corresponding symptoms and an ineffective trial of at least 1 antiarrhythmic drug were selected for RF ablation. With the use of CARTO, circumferential lesions around the pulmonary veins and linear lesions at the roof of the left atrium and along the left atrial isthmus were placed. A continuous, 7-day, Holter session was recorded before ablation, right after ablation, and after 3, 6, and 12 months of follow-up. During each 7-day Holter monitoring, the patients recorded quality and duration of any complaints by using a detailed symptom log. More than 70,000 hours of ECG recording were analyzed. In the 7-day Holter records before ablation, 92 of 114 patients (81%) had documented AF episodes. All episodes were symptomatic in 35 patients (38%). In 52 patients (57%), both symptomatic and asymptomatic episodes were recorded, whereas in 5 patients (5%), all documented AF episodes were asymptomatic. After ablation, the percentage of patients with only asymptomatic AF recurrences increased to 37% (P<0.05) at the 6-month follow-up. An analysis of patient characteristics and arrhythmia patterns failed to identify a specific subset who were at high risk for the development of asymptomatic AF. CONCLUSIONS Even in patients presenting with highly symptomatic AF, asymptomatic episodes may occur and significantly increase after catheter ablation. A symptom-only-based follow-up would substantially overestimate the success rate. Objective measures such as long-term Holter monitoring are needed to identify asymptomatic AF recurrences after ablation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Idiopathic ventricular tachycardia (VT) often originates from the right ventricular outflow tract (RVOT), but foci deep to the endocardium, in the epicardium, or in the left ventricle are not uncommon. Although these extra-RVOT foci can be targeted with ablation, risks involved are higher and success rates lower. Simple electrocardiographic (ECG) criteria allowing (1) discrimination of RVOT foci from extra-RVOT foci and (2) assessment of the chance of success of a right heart ablation procedure are desirable. METHODS Twenty-five consecutive patients referred for radiofrequency (RF) ablation of idiopathic VT or severely symptomatic idiopathic ventricular premature contractions were included. Localization of VT origin and success rates of VT ablation in the RVOT were analyzed according to the ECG pattern. RESULTS The analysis of the R wave in V2 was the strongest single predictor of whether the VT had an RVOT or an extra-RVOT origin. An R wave amplitude < or =30% of the QRS amplitude designated the VT focus in the RVOT with positive and negative predictive values of 95 and 100%, respectively. Analysis of R wave duration in V2 had similar predictive values, whereas the R/S transition zone in precordial leads had slightly lower predictive values. Seventeen of 20 arrhythmias (85%) with an R wave amplitude < or =30% of the QRS amplitude in V2 could be successfully abolished by an exclusively right heart procedure. CONCLUSIONS The analysis of ECG pattern makes it possible to guide the management of patients with idiopathic VT in predicting the arrhythmias that can be safely targeted with RF ablation from the RVOT with high success rates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION Intraoperative radiofrequency (RF) ablation is an effective treatment of atrial fibrillation (AF). However, secondary arrhythmias late after ablation may complicate the patient's course. We report on the incidence, mechanisms, and treatment of gap-related atrial flutter and other secondary arrhythmias during long-term follow-up. METHODS AND RESULTS In 129 patients who underwent intraoperative RF ablation with placement of left atrial linear lesions using minimally invasive surgical techniques, secondary arrhythmias were analyzed during long-term follow-up (20 +/- 6 months). Transient atrial arrhythmias during the first 3 postoperative months were excluded. In 8 (6.2%) of 129 patients, sustained stable secondary arrhythmias were documented. Left atrial, gap-related atrial flutter was observed in 4 patients (3.1%). The flutter was treated by percutaneous RF ablation in 3 patients (2.3%) and with drugs in 1 patient (0.8%). In 2 patients (1.6%), right atrial isthmus-dependent atrial flutter occurred and was treated successfully by percutaneous RF ablation. In 2 patients (1.6%), ectopic right atrial tachycardias occurred and were treated with percutaneous RF ablation. CONCLUSION Late after intraoperative RF ablation of atrial fibrillation, three types of stable secondary arrhythmias were observed in 6% of patients: left atrial gap-related atrial flutter, right atrial isthmus-dependent atrial flutter, and ectopic atrial tachycardia. Gaps after intraoperative RF ablation due to noncontinuous or nontransmural linear lesions may lead to stable left atrial macroreentrant tachycardias, requiring new interventional therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Open-irrigated radiofrequency catheter ablation (oiRFA) of atrial fibrillation (AF) imposes a volume load and risk of pulmonary edema. We sought to assess the effect of volume administration during ablation on left atrial (LA) pressure and B-type natriuretic peptide (BNP). Methods LA pressure was measured via transseptal sheath at the beginning and end of 44 LA ablation procedures in 42 patients. BNP plasma levels were measured before and after 10 procedures. Results A median of 3,255 (interquartile range [IQR], 2,014)-mL saline was administered during the procedure. During LA ablation, the median fluid balance was +1,438 (IQR, 1,109) mL and LA pressure increased by median 3.7 (IQR, 5.9) mm Hg (P < 0.001). LA pressure did not change in the 19 procedures with furosemide administration (median ΔP = −0.3 [IQR, 7.1] mm Hg, P = 0.334). The correlation of LA pressure and fluid balance was weak (rs = 0.383, P = 0.021). BNP decreased in all four procedures starting in AF or atrial tachycardia and then converting to sinus rhythm (P = 0.068), and increased in all six procedures starting and finishing in sinus rhythm (P = 0.028). After ablation, symptomatic volume overload responding to diuresis occurred in three patients. Conclusions A substantial intravascular volume load during oiRFA can be absorbed with little change in LA pressure, such that LA pressure is not a reliable indicator of the fluid balance. Subsequent redistribution of the volume load imposes a risk after the procedure. Conversion to sinus rhythm may improve ability to acutely accommodate the volume load.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gemcitabine is a potent nucleoside analogue against solid tumors however drug resistance rapidly emerges. Removal of gemcitabine incorporated in the DNA by repair mechanisms could potentially contribute to resistance in chemo-refractory solid tumors. In this study, we evaluated homologous recombination repair of gemcitabine-stalled replication forks as a potential mechanism contributing to resistance. We also studied the effect of hyperthermia on homologous recombination pathway to explain the previously reported synergy between gemcitabine and hyperthermia. We found that hyperthermia degrades and inhibits localization of Mre11 to gemcitabine-stalled replication forks. Furthermore, gemcitabine-treated cells that were also treated with hyperthermia demonstrate a prolonged passage through late S/ G2 phase of cell cycle in comparison to cells treated with gemcitabine alone. This coincides with inhibition of resolution of γH2AX foci. Our findings also demonstrate that thermal sensitization of human hepatocellular carcinoma cell lines to gemcitabine is mediated through an Mre11-dependent homologous recombination repair pathway. Combination of non-invasive radiofrequency field-induced hyperthermia and gemcitabine was superior to either therapy alone (p

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This report describes the development of a Markov model for comparing percutaneous radiofrequency ablation (RFA) and stereotactic body radiation therapy (SBRT) in terms of their cost-utility in treating isolated liver metastases from colorectal cancer. The model is based on data from multiple retrospective and prospective studies, available data on different utility states associated with treatment and complications, as well as publicly available Medicare costs. The purpose of this report is to establish a well-justified model for clinical management decisions. In comparison with SBRT, RFA is the most cost-effective treatment for this patient population. From the societal perspective, SBRT may be an acceptable alternative with an ICER of $28,673/QALY. ^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Six-port network is an interesting radiofrequency architecture with multiple possibilities. Since it was firstly introduced in the seventies as an alternative network analyzer, the six-port network has been used for many applications, such as homodyne receivers, radar systems, direction of arrival estimation, UWB (Ultra-Wide-Band), or MIMO (Multiple Input Multiple Output) systems. Currently, it is considered as a one of the best candidates to implement a Software Defined Radio (SDR). This thesis comprises an exhaustive study of this promising architecture, where its fundamentals and the state-of-the-art are also included. In addition, the design and development of a SDR 0.3-6 GHz six-port receiver prototype is presented in this thesis, which is implemented in conventional technology. The system is experimentally characterized and validated for RF signal demodulation with good performance. The analysis of the six-port architecture is complemented by a theoretical and experimental comparison with other radiofrequency architectures suitable for SDR. Some novel contributions are introduced in the present thesis. Such novelties are in the direction of the highly topical issues on six-port technique: development and optimization of real-time I-Q regeneration techniques for multiport networks; and search of new techniques and technologies to contribute to the miniaturization of the six-port architecture. In particular, the novel contributions of this thesis can be summarized as: - Introduction of a new real-time auto-calibration method for multiport receivers, particularly suitable for broadband designs and high data rate applications. - Introduction of a new direct baseband I-Q regeneration technique for five-port receivers. - Contribution to the miniaturization of six-port receivers by the use of the multilayer LTCC (Low Temperature Cofired Ceramic) technology. Implementation of a compact (30x30x1.25 mm) broadband (0.3-6 GHz) six-port receiver in LTTC technology. The results and conclusions derived from this thesis have been satisfactory, and quite fruitful in terms of publications. A total of fourteen works have been published, considering international journals and conferences, and national conferences. Aditionally, a paper has been submitted to an internationally recognized journal, which is currently under review.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Radiofrequency ablation (RFA) from the epicardial space for ventricular arrhythmias is limited or impossible in some cases. Reasons for epicardial ablation failure and the effect on outcome have not been systematically analyzed. METHODS AND RESULTS We assessed reasons for epicardial RFA failure relative to the anatomic target area and the type of heart disease and assessed the effect of failed epicardial RFA on outcome after ablation procedures for ventricular arrhythmias in a large single-center cohort. Epicardial access was attempted during 309 ablation procedures in 277 patients and was achieved in 291 procedures (94%). Unlimited ablation in an identified target region could be performed in 181 cases (59%), limited ablation was possible in 22 cases (7%), and epicardial ablation was deemed not feasible in 88 cases (28%). Reasons for failed or limited ablation were unsuccessful epicardial access (6%), failure to identify an epicardial target (15%), proximity to a coronary artery (13%), proximity to the phrenic nerve (6%), and complications (<1%). Epicardial RFA was impeded in the majority of cases targeting the left ventricular summit region. Acute complications occurred in 9%. The risk for acute ablation failure was 8.3× higher (4.5-15.0; P<0.001) after no or limited epicardial RFA compared with unlimited RFA, and patients with unlimited epicardial RFA had better recurrence-free survival rates (P<0.001). CONCLUSIONS Epicardial RFA for ventricular arrhythmias is often limited even when pericardial access is successful. Variability of success is dependent on the target area, and the presence of factors limiting ablation is associated with worse outcomes.