985 resultados para Radiation sources.
Resumo:
The sources of betatherapy for clinical use in Brazil are, the vast majority of strontium-90, radioactive element that is not produced in the country, and therefore requires importation of international laboratories accredited by the International Atomic Energy Agency (IAEA).The use of these resources is always limited the crediting of characteristic values supplied by the manufacturer tables that provide the nominal value of activity and dose distribution to determine the irradiation time of the injury. The Institute of Nuclear Energy Research (IPEN / CNEN-SP) has recently researching the emission profile of these types of radiation sources, and some jobs are being developed with ionization chambers extrapolation for the purpose of standardizing a systematic calibration sources betatherapy. Other studies using parallel measures dosimeters (TLD's) and simulations with the Monte Carlo method. Radiological films have also been used in studies of applicators dosimetric analysis of strontium-90. This paper seeks to analyze the different methods for calibration of applicators betatherapy, already consolidated in studies by examining the advantages and disadvantages of each procedure
Resumo:
A variety of occupational hazards are indigenous to academic and research institutions, ranging from traditional life safety concerns, such as fire safety and fall protection, to specialized occupational hygiene issues such as exposure to carcinogenic chemicals, radiation sources, and infectious microorganisms. Institutional health and safety programs are constantly challenged to establish and maintain adequate protective measures for this wide array of hazards. A unique subset of academic and research institutions are classified as historically Black universities which provide educational opportunities primarily to minority populations. State funded minority schools receive less resources than their non-minority counterparts, resulting in a reduced ability to provide certain programs and services. Comprehensive health and safety services for these institutions may be one of the services compromised, resulting in uncontrolled exposures to various workplace hazards. Such a result would also be contrary to the national health status objectives to improve preventive health care measures for minority populations.^ To determine if differences exist, a cross-sectional survey was performed to evaluate the relative status of health and safety programs present within minority and non-minority state-funded academic and research institutions. Data were obtained from direct mail questionnaires, supplemented by data from publicly available sources. Parameters for comparison included reported numbers of full and part-time health and safety staff, reported OSHA 200 log (or equivalent) values, and reported workers compensation experience modifiers. The relative impact of institutional minority status, institution size, and OSHA regulatory environment, was also assessed. Additional health and safety program descriptors were solicited in an attempt to develop a preliminary profile of the hazards present in this unique work setting.^ Survey forms were distributed to 24 minority and 51 non-minority institutions. A total of 72% of the questionnaires were returned, with 58% of the minority and 78% of the non-minority institutions participating. The mean number of reported full-time health and safety staff for the responding minority institutions was determined to be 1.14, compared to 3.12 for the responding non-minority institutions. Data distribution variances were stabilized using log-normal transformations, and although subsequent analysis indicated statistically significant differences, the differences were found to be predicted by institution size only, and not by minority status or OSHA regulatory environment. Similar results were noted for estimated full-time equivalent health and safety staffing levels. Significant differences were not noted between reported OSHA 200 log (or equivalent) data, and a lack of information provided on workers compensation experience modifiers prevented comparisons on insurance premium expenditures. Other health and safety program descriptive information obtained served to validate the study's presupposition that the inclusion criteria would encompass those organizations with occupational risks from all four major hazard categories. Worker medical surveillance programs appeared to exist at most institutions, but the specific tests completed were not readily identifiable.^ The results of this study serve as a preliminary description of the health and safety programs for a unique set of workplaces have not been previously investigated. Numerous opportunities for further research are noted, including efforts to quantify the relative amount of each hazard present, the further definition of the programs reported to be in place, determination of other means to measure health outcomes on campuses, and comparisons among other culturally diverse workplaces. ^
Resumo:
Theoretical X-ray opacities are used in numerous radiative transfer simulations of plasmas at different temperatures and densities, for example astrophysics, fusion, metrology and EUV and X-rays radiation sources. However, there are only a reduced number of laboratories working on the validation of those theoretical results empirically, in particular for high temperature plasmas (mayor que 1eV). One of those limitations comes from the use of broad band EUV- X ray sources to illuminate the plasma which, among other issues, present low reproducibility and repetition rate [1]. Synchrotron radiation facilities are a more appropriate radiation source in that sense, since they provide tunable, reproducible and high resolution photons. Only their ?low? photon intensity for these experiments has prevented researchers to use it for this purpose. However, as new synchrotron facilities improve their photon fluxes, this limitation not longer holds [2]. This work evaluates the experimental requirements to use third generation synchrotron radiation sources for the empirical measurement of opacities of plasmas, proposing a pausible experimental set-up to carry them out. Properties of the laser or discharge generated plasmas to be studied with synchrotron radiation will be discussed in terms of their maximum temperatures, densities and temporal evolution. It will be concluded that there are encouraging reasons to pursue these kind of experiments which will provide with an appropriate benchmark for theoretical opacities
Resumo:
Item 245.
Resumo:
Control of the collective response of plasma particles to intense laser light is intrinsic to relativistic optics, the development of compact laser-driven particle and radiation sources, as well as investigations of some laboratory astrophysics phenomena. We recently demonstrated that a relativistic plasma aperture produced in an ultra-thin foil at the focus of intense laser radiation can induce diffraction, enabling polarization-based control of the collective motion of plasma electrons. Here we show that under these conditions the electron dynamics are mapped into the beam of protons accelerated via strong charge-separation-induced electrostatic fields. It is demonstrated experimentally and numerically via 3D particle-in-cell simulations that the degree of ellipticity of the laser polarization strongly influences the spatial-intensity distribution of the beam of multi-MeV protons. The influence on both sheath-accelerated and radiation pressure-accelerated protons is investigated. This approach opens up a potential new route to control laser-driven ion sources.
Resumo:
The present work is concerned with the use of the cross correlation technique to measure delay time between two simulated signals displaced with respect to time, in order to develop a cross correlator system that will be used to measure the water and oil pipes flowrate in which the detection system is composed by two external low intensity radiation sources located along the tube and two NaI(Tl) gamma-ray detectors. The final purpose of the correlator system is to use the natural disturbances, as the turbulence in the own flow rather than to inject radioactive tracers to the fluid flow as usually is carried out. In the design of this correlator is evaluated the point-by-point calculation method for the cross correlation function in order to produce a system accurate and fast. This method is divided at the same time in three modes of operation: direct, relay and polarity.
Resumo:
Dissertacao (Mestrado)
Resumo:
Irradiation is a methodology qualified for dry ingredients preservation or decontamination and can be performed using various radiation sources and energy levels in accordance with the objectives to be achieved [1]. Electron beam irradiation is used mainly for food products with low density, while gamma irradiation is mainly used for large volumes [2]. Arenaria Montana L. has a high antioxidant potential and richness in bioactive phytochemicals. It is used in Portuguese traditional medicine, acting therapeutically as an anti-inflammatory and diuretic plant [3]. The aim of this work was to evaluate the effects of gamma and electron beam irradiation at different doses (I and 10 kGy) in the antioxidant activity of A. montana. Free radicals scavenging activity, reducing power and lipid peroxidation inhibition properties of its methanolic extracts and infusions were evaluated. Through a global analysis, it was concluded that the antioxidant activity proved to be higher in methanolic extracts in comparison with the infusions, where it decreased with increasing irradiation dose regardless of the technology used (gamma or electron beam). For methanolic extracts, electron beam resulted in increased antioxidant activity while gamma irradiation caused a decrease in these extracts. Thus, the antioxidant potential is variable depending not only on the type of radiation and the dose applied, but also on the solvent used in the preparation of the extracts (methanol or water).
Resumo:
This study examines differences in the surface black carbon (BC) aerosol loading between the Bay of Bengal (BoB) and the Arabian Sea (AS) and identifies dominant sources of BC in South Asia and surrounding regions during March-May 2006 (Integrated Campaign for Aerosols, Gases and Radiation Budget, ICARB) period. A total of 13 BC tracers are introduced in the Weather Research and Forecasting Model coupled with Chemistry to address these objectives. The model reproduced the temporal and spatial variability of BC distribution observed over the AS and the BoB during the ICARB ship cruise and captured spatial variability at the inland sites. In general, the model underestimates the observed BC mass concentrations. However, the model-observation discrepancy in this study is smaller compared to previous studies. Model results show that ICARB measurements were fairly well representative of the AS and the BoB during the pre-monsoon season. Elevated BC mass concentrations in the BoB are due to 5 times stronger influence of anthropogenic emissions on the BoB compared to the AS. Biomass burning in Burma also affects the BoB much more strongly than the AS. Results show that anthropogenic and biomass burning emissions, respectively, accounted for 60 and 37% of the average +/- standard deviation (representing spatial and temporal variability) BC mass concentration (1341 +/- 2353 ng m(-3)) in South Asia. BC emissions from residential (61 %) and industrial (23 %) sectors are the major anthropogenic sources, except in the Himalayas where vehicular emissions dominate. We find that regional-scale transport of anthropogenic emissions contributes up to 25% of BC mass concentrations in western and eastern India, suggesting that surface BC mass concentrations cannot be linked directly to the local emissions in different regions of South Asia.