34 resultados para QFT
Resumo:
Since interferon-gamma release assays (IGRAs) were introduced in the 2000's, tuberculin skin testing (TST) and IGRAs have been used in various latent tuberculosis infection (LTBI) screening settings. IGRAs are laboratory-based tests and are considered not to be affected by previous Bacille de Calmette et Guérin (BCG) vaccination; however, they are more costly when compared directly with TST, which does not require specimen processing in a laboratory. This study aimed to examine TST and two types of IGRAs, QuantiFERON-TB Gold in Tube (QFT-GIT) and T-SPOT. TB (TSPOT), from an economic viewpoint. Firstly, a systematic literature review was conducted to identify cost related analyses of LTBI screening. Secondly, specific cost information detailing each test's items and labor was collected from an LTBI screening program of health care workers in Houston, and the cost of each test was computed. Thirdly, using the computed cost estimate of each test, cost-effectiveness analyses were conducted to compare TST and IGRAs.^ A literature search showed that a limited number of studies have been conducted, but the IGRA's economic advantages were common among studies. Cost analyses showed that IGRAs were much more costly than TST. The results were consistent with previous studies. In cost-effectiveness analyses, where test cost and consequential TB-related cost were considered, IGRAs showed variable advantages over TST depending on the targeted population. When only non BCG-vaccinated people were considered, TST was the least costly option among the three tests. On the other hand, when only BCG-vaccinated people were considered, IGRAs were less costly options. These results were mostly consistent even with varying assumption parameters.^ IGRAs can be more costly than TST, but their economic disadvantages are alleviated when the target population was BCG-vaccinated. Based on current knowledge, IGRAs may be recommended in a population where the BCG history is mixed. Additional studies are needed to better understand IGRA's reliability among low-incidence and low-risk populations in which background TB prevalence is low.^
Resumo:
BACKGROUND. The development of interferon-gamma release assays (IGRA) has introduced powerful tools in diagnosing latent tuberculosis infection (LTBI) and may play a critical role in the future of tuberculosis diagnosis. However, there have been reports of high indeterminate results in young patient populations (0-18 years). This study investigated results of the QunatiFERON-TB Gold In-Tube (QFT-GIT) IGRA in a population of children (0-18 years) at Texas Children's Hospital in association with specimen collection procedures using surrogate variables. ^ METHODS. A retrospective case-control study design was used for this investigation. Cases were defined as having QFT-GIT indeterminate results. Controls were defined as having either positive or negative results (determinates). Patients' admission status, staff performing specimen collection, and specific nurse performing specimen collection were used as surrogates to measure specimen collection procedures. ^ To minimize potential confounding, abstraction of patients' electronic medical records was performed. Abstracted data included patients' medications and evaluation at the time of QFT-GIT specimen collection in addition to their medical history. QFT-GIT related data was also abstracted. Cases and controls were characterized using chi-squared tests or Fisher's exact tests across categorical variables. Continuous variables were analyzed using one-way ANOVA and t-tests for continuous variables. A multivariate model was constructed by backward stepwise removal of statistically significant variables from univariate analysis. ^ RESULTS. Patient data was abstracted from 182 individuals aged 0-18 years from July 2010 to August 2011 at Texas Children's Hospital. 56 cases (indeterminates) and 126 controls (determinates) were enrolled. Cancer was found to be an effect modifier with subsequent stratification resulting in a cancer patient population too small to analyze (n=13). Subsequent analyses excluded these patients. ^ The exclusion of cancer patients resulted in a population of 169 patients with 49 indeterminates (28.99%) and 120 determinates (71.01%), with mean ages of 9.73 (95% CI: 8.03, 11.43) years and 11.66 (95% CI: 10.75, 12.56) years (p = 0.033), respectively. Median age of patients who were indeterminates and determinates were 12.37 and 12.87 years, respectively. Lack of data for our specific nurse surrogate (QFTNurse) resulted in its exclusion from analysis. The final model included only our remaining surrogate variables (QFTStaff and QFTInpatientOutpatient). The staff collecting surrogate (QFTStaff) was found to be modestly associated with indeterminates when nurses collected the specimen (OR = 1.54, 95% CI: 0.51, 4.64, p = 0.439) in the final model. Inpatients were found to have a strong and statistically significant association with indeterminates (OR = 11.65, 95% CI: 3.89, 34.9, p < 0.001) in the final model. ^ CONCLUSION. Inpatient status was used as a surrogate for indication of nurse drawn blood specimens. Nurses have had little to no training regarding shaking of tubes versus phlebotomists regarding QFT-GIT testing procedures. This was also measured by two other surrogates; specifically a medical note stating whether a nurse or phlebotomist collected the specimen (QFTStaff) and the name and title of the specific nurse if collection was performed by a nurse (QFTNurse). Results indicated that inpatient status was a strong and statistically significant factor for indeterminates, however, nurse collected specimens and indeterminate results had no statistically significant association in non-cancer patients. The lack of data denoting the specific nurse performing specimen collection excluded the QFTNurse surrogate in our analysis. ^ Findings suggests training of staff personnel in specimen procedures may have little effect on the number of indeterminates while inpatient status and thus possibly illness severity may be the most important factor for indeterminate results in this population. The lack of congruence between our surrogate measures may imply that our inpatient surrogate gauged illness severity rather than collection procedures as intended. ^ Despite the lack of clear findings, our analysis indicated that more than half of indeterminates were found in specimens drawn by nurses and as such staff training may be explored. Future studies may explore methods in measuring modifiable variables during pre-analytical QFT-GIT procedures that can be discerned and controlled. Identification of such measures may provide insight into ways to lowering indeterminate QFT-GIT rates in children.^
Resumo:
This paper re-examines the stability of multi-input multi-output (MIMO) control systems designed using sequential MIMO quantitative feedback theory (QFT). In order to establish the results, recursive design equations for the SISO equivalent plants employed in a sequential MIMO QFT design are established. The equations apply to sequential MIMO QFT designs in both the direct plant domain, which employs the elements of plant in the design, and the inverse plant domain, which employs the elements of the plant inverse in the design. Stability theorems that employ necessary and sufficient conditions for robust closed-loop internal stability are developed for sequential MIMO QFT designs in both domains. The theorems and design equations facilitate less conservative designs and improved design transparency.
Resumo:
La tuberculosis TB es una de las principales causas de muerte en el mundo en individuos con infección por VIH. En Colombia esta coinfección soporta una carga importante en la población general convirtiéndose en un problema de salud pública. En estos pacientes las pruebas diagnósticas tienen sensibilidad inferior y la enfermedad evoluciona con mayor frecuencia hacia formas diseminadas y rápidamente progresivas y su diagnóstico oportuno representa un reto en Salud. El objetivo de este proyecto es evaluar el desempeño de las pruebas diagnósticas convencionales y moleculares, para la detección de TB latente y activa pacientes con VIH, en dos hospitales públicos de Bogotá. Para TB latente se evaluó la concordancia entre las pruebas QuantiFERON-TB (QTF) y Tuberculina (PPD), sugiriendo superioridad del QTF sobre la PPD. Se evaluaron tres pruebas diagnósticas por su sensibilidad y especificidad, baciloscopia (BK), GenoType®MTBDR plus (Genotype) y PCR IS6110 teniendo como estándar de oro el cultivo. Los resultados de sensibilidad (S) y especificidad (E) de cada prueba con una prevalencia del 19,4 % de TB pulmonar y extrapulmonar en los pacientes que participaron del estudio fue: BK S: 64% E: 99,1%; Genotype S: 77,8% E: 94,5%; PCRIS6110 S: 73% E: 95,5%, de la misma forma se determinaron los valores predictivos positivos y negativos (VPP y VPN) BK: 88,9% y 94,8%, Genotype S: 77,8% E: 94,5%; PCRIS6110 S: 90% y 95,7%. Se concluyó bajo análisis de curva ROC que las pruebas muestran un rendimiento diagnóstico similar por separado en el diagnóstico de TB en pacientes con VIH, aumentando su rendimiento diagnostico cuando se combinan