981 resultados para Py-GC-MS
Resumo:
Drug screening is an important issue in clinical and forensic toxicology. Gas chromatography coupled to mass spectrometry (GC-MS) remains the gold standard technique for the screening of unknown compounds in urine samples. However, this technique requires substantial sample preparation, which is time consuming. Moreover, some common drugs such as cannabis cannot be easily detected in urine using general procedures. In this work, a sample preparation protocol for treating 200 μL of urine in less than 30 min is described. The enzymatic hydrolysis of glucuro-conjugates was performed in 5 min thanks to the use of microwaves. The use of a deconvolution software allowed reducing the GC-MS run to 10 min, without impairing the quality of the compound identifications. Comparing the results from 139 authentic urine samples to those obtained using the current routine analysis indicated this method performed well. Moreover, additional 5-min GC-MS/MS programs are described, enabling a very sensitive target screening of 54 drugs, including THC-COOH or buprenorphine, without further sample preparation. These methods appeared as an interesting alternative to immuno-assays based screening. The analytical strategy presented in this article proved to be a promising approach for systematic toxicological analysis (STA) of drugs in urine.
Resumo:
A headspace solid-phase microextraction procedure (HS-SPME) was developed for the profiling of traces present in 3,4-methylenedioxymethylampethamine (MDMA). Traces were first extracted using HS-SPME and then analyzed by gas chromatography-mass spectroscopy (GC-MS). The HS-SPME conditions were optimized using varying conditions. Optimal results were obtained when 40 mg of crushed MDMA sample was heated at 80 °C for 15 min, followed by extraction at 80 °C for 15 min with a polydimethylsiloxane/divinylbenzene coated fibre. A total of 31 compounds were identified as traces related to MDMA synthesis, namely precursors, intermediates or by-products. In addition some fatty acids used as tabletting materials and caffeine used as adulterant, were also detected. The use of a restricted set of 10 target compounds was also proposed for developing a screening tool for clustering samples having close profile. 114 seizures were analyzed using an SPME auto-sampler (MultiPurpose Samples MPS2), purchased from Gerstel GMBH & Co. (Germany), and coupled to GC-MS. The data was handled using various pre-treatment methods, followed by the study of similarities between sample pairs based on the Pearson correlation. The results show that HS-SPME, coupled with the suitable statistical method is a powerful tool for distinguishing specimens coming from the same seizure and specimens coming from different seizures. This information can be used by law enforcement personnel to visualize the ecstasy distribution network as well as the clandestine tablet manufacturing.
Resumo:
For more than a decade scientists tried to develop methods capable of dating ink by monitoring the loss of phenoxyethanol (PE) over time. While many methods were proposed in the literature, few were really used to solve practical cases and they still raise much concern within the scientific community. In fact, due to the complexity of ink drying processes it is particularly difficult to find a reliable ageing parameter to reproducibly follow ink ageing. Moreover, systematic experiments are required in order to evaluate how different factors actually influence the results over time. Therefore, this work aimed at evaluating the capacity of four different ageing parameters to reliably follow ink ageing over time: (1) the quantity of solvent PE in an ink line, (2) the relative peak area (RPA) normalising the PE results using stable volatile compounds present in the ink formulation, (3) the solvent loss ratio (R%) calculated from PE results obtained by the analyses of naturally and artificially aged samples, (4) a modified solvent loss ratio version (R%*) calculated from RPA results. After the determination of the limits of reliable measurements of the analytical method, the repeatability of the different ageing parameters was evaluated over time, as well as the influence of ink composition, writing pressure and storage conditions on the results. Surprisingly, our results showed that R% was not the most reliable parameter, as it showed the highest standard deviation. Discussion of the results in an ink dating perspective suggests that other proposed parameters, such as RPA values, may be more adequate to follow ink ageing over time.
Resumo:
For more than a decade scientists tried to develop methods capable of dating ink by monitoring the loss of phenoxyethanol (PE) over time. While many methods were proposed in the literature, few were really used to solve practical cases and they still raise much concern within the scientific community. In fact, due to the complexity of ink drying processes it is particularly difficult to find a reliable ageing parameter to reproducibly follow ink ageing. Moreover, systematic experiments are required in order to evaluate how different factors actually influence the results over time. Therefore, this work aimed at evaluating the capacity of four different ageing parameters to reliably follow ink ageing over time: (1) the quantity of solvent PE in an ink line, (2) the relative peak area (RPA) normalising the PE results using stable volatile compounds present in the ink formulation, (3) the solvent loss ratio (R%) calculated from PE results obtained by the analyses of naturally and artificially aged samples, (4) a modified solvent loss ratio version (R%*) calculated from RPA results. After the determination of the limits of reliable measurements of the analytical method, the repeatability of the different ageing parameters was evaluated over time, as well as the influence of ink composition, writing pressure and storage conditions on the results. Surprisingly, our results showed that R% was not the most reliable parameter, as it showed the highest standard deviation. Discussion of the results in an ink dating perspective suggests that other proposed parameters, such as RPA values, may be more adequate to follow ink ageing over time.
Resumo:
Gas chromatography coupled with mass spectrometry (GC-MS) is widely used for the characterization of volatile compounds. However, due to the complexity of the soluble coffee matrix, a complete identification of the components should not be based on mass spectra interpretation only. The linear index of retention (LRI) is frequently used to give support to mass spectra. The aim of this work is to investigate the characterization of the volatile compounds in soluble coffee samples by GC-MS using LRI values found with a HP-INNOWAX column. The method used allows a significant increase of the reliability of identifying compounds.
Resumo:
A method based on matrix solid-phase dispersion and gas chromatography-mass spectrometry to determine procymidone, malathion, bifenthrin and pirimicarb in honey is described. The best results were obtained using 1.0 g of honey, 1.0 g of silica-gel as dispersant sorbent and acetonitrile as eluting solvent. The method was validated by fortified honey samples at three concentration levels (0.2, 0.5 to 1.0 mg kg-1). Average recoveries (n=7) ranged from 54 to 84%, with relative standard deviations between 3.7 and 8.5%. Detection and quantification limits attained by the developed method ranged from 0.02 to 0.08 mg kg-1 and 0.07 to 0.25 mg kg-1 for the honey, respectively.
Resumo:
Dipteryx odorata (Aubl.) Willd. is a tall arboreal species native to Central and Northern South America. This paper describes the chemical characterization and phytotoxic potential of polar and non-polar extracts from D. odorata seeds. Structural determinations were accomplished by chemical derivatization and analyzed by GC/MS. The chemical composition of the non-polar fraction (hexane and dichloromethane) presented fatty acids as major constituent. Medium polar and polar fractions (ethyl acetate and ethanol: water) contained carboxylic acid and high 6,7-Dyhidroxycoumarin-β-D-glucopyranoside content, not previously reported for seeds of D. odorata. Extracts showed a significant level of phytotoxic activity, correlated to the content of coumarin derivatives, predominantly in the polar fraction.
Resumo:
Considering the possibility that pesticides used in cattle raising produce residues in milk and cause harm to public health, this study developed a multiresidue method for determination of pesticide residues in bovine milk, using a modified QuEChERS method for sample preparation, and quantification by GC-MS/MS. The method proved to be efficient, resulting in satisfactory recoveries in the range 71.1 to 117.4%, for 45 of the 48 compounds analyzed with RSD values < 17.3%. The method LOD and LOQ were3.0 and 10.0 µg L-1, respectively, except for cyfluthrin which showed 7.5 and 25.0 µg L-1.
Resumo:
This paper reports on the identification of volatile and semi-volatile compounds and a comparison of the chromatographic profiles obtained by Headspace Solid-Phase Microextraction/Gas Chromatography with Mass Spectrometry detection (HS-SPME-GC-MS) of dried leaves of Mikania glomerata Sprengel (Asteraceae), also known as 'guaco.' Three different types of commercial SPME fibers were tested: polydimethylsiloxane (PDMS), polydimethylsiloxane/divinylbenzene (PDMS/DVB) and polyacrylate (PA). Fifty-nine compounds were fully identified by HS-SPME-HRGC-MS, including coumarin, a marker for the quality control of guaco-based phytomedicines; most of the other identified compounds were mono- and sesquiterpenes. PA fibers performed better in the analysis of coumarin, while PDMS-DVB proved to be the best choice for a general and non-selective analysis of volatile and semi-volatile guaco-based compounds. The SPME method is faster and requires a smaller sample than conventional hydrodistillation of essential oils, providing a general overview of the volatile and semi-volatile compounds of M. glomerata.
Resumo:
Os hidrocarbonetos policíclicos aromáticos (HPAs) estão associados ao aumento da incidência de diversos tipos de cânceres no homem. Essas moléculas são formadas principalmente na queima incompleta de matéria orgânica, sendo encontradas em todos os compartimentos ambientais. Órgãos regulamentadores das áreas ambiental e de saúde ocupacional consideram 17 HPAs como contaminantes atmosféricos prioritários. Este trabalho apresenta um método para análise simultânea destes HPAs utilizando-se a cromatografia a gás acoplada à espectrometria de massas operando no modo tandem (GC-MS/MS). Os limites de detecção e quantificação do método mostraram-se até 5 vezes inferiores aos obtidos no método GC-MS (SCAN). O método mostrou-se seletivo para análise de HPAs em extratos de amostras de material particulado atmosférico. Uma análise comparativa de dois sistemas de solventes (diclorometano/metanol 4:1 v/v e hexano/acetona 1:1 v/v) para a extração de HPAs, utilizando amostras de material particulado atmosférico, revelou que ambas as misturas de solventes possuem poder de extração semelhante. Os resultados sugerem que é possível realizar extração de HPAs de material particulado atmosférico em ultra-som com a mistura hexano/acetona (1:1), que é menos tóxica em relação à mistura diclorometano/metanol (4:1), bastante utilizada nestas análises, sem perdas significativas na exatidão do método.
Resumo:
A preliminary analysis by GC-MS comparing the mass spectrum of the compounds with the Wiley 275 L mass spectral data base was used to identify the fatty acids and mainly, some volatile compounds responsible for the flavor of the roasted coffee oil. The oil was obtained by mechanical expelling of Brazilian beans (Coffea arabica) roasted at 238ºC for 10 minutes. Different sample preparation methodologies such as headspace, adsorbent suction trapping and esterification were used. It was possible to identify pyrazines, pyridines, furan derivatives and other compounds not reported in the literature.
Resumo:
(E)-2-nonenal is considered an important off-flavor of beer, related to the flavor of beer staling. In this study, a new method for determination of (E)-2-nonenal in beer using headspace solid-phase microextraction and gas chromatographic coupled mass spectrometry (HS-SPME-GC-MS) was developed and applied in Brazilian beer samples. The extractions were carried out in CAR-PDMS (carboxen-polydimethylsiloxane) fiber and the best results were found with 15 minutes of equilibrium and 90 minutes of extraction at 50 °C. The method was linear in the range from 0.02 to 4.0 μg.L-1 with correlation coefficient of 0.9994. The limits of detection and quantification were 0.01 and 0.02 μg.L-1, respectively. 96.5% of recovery and 4% precision (RSD) were obtained in the fortification of beer samples with 2.0 μg.L-1 of (E)-2-nonenal. The developed method proved to be simple, efficient and highly sensitive to the determination of this analyte being easily applied in the quality control of the brewery. (E)-2-nonenal was found in all beer samples analyzed with levels between 0.17 and 0.42 μg.L-1.
Resumo:
Abstract Brazilian wine production is characterized by Vitis labrusca grape varieties, especially the economically important Isabel cultivar, with over 80% of its production destined for table wine production. The objective of this study was to optimize and validate the conditions for extracting volatile compounds from wine with the solid-phase microextraction technique, using the response surface method. Based on the response surface analysis, it can be concluded that the central point values maximize the process of extracting volatile compounds from wine, i.e., an equilibrium time of 15 minutes, an extraction time of 35 minutes, and an extraction temperature of 30 °C. Esters were the most numerous compounds found under these extraction conditions, indicating that wines made from Isabel cultivar grapes are characterized by compounds that confer a fruity aroma; this finding corroborates the scientific literature.