998 resultados para Pumping system


Relevância:

60.00% 60.00%

Publicador:

Resumo:

After the Protocol of Kyoto and of the ECHO 92 - Rio de Janeiro, the attentions of the world focus to the preservation of the environment and of the maintainable use of the natural resources. People were looking for preserving environment for the future generations. Ever since, solutions are looked for the supply of energy in its more acquaintances forms and the substitution of the use of fossil fuels for the such alternative forms as: Photovoltaics, solar heat systems for water, wind , bio-diesel, etc. and in this context the Company of Engineering of the State of Bahia - Cerb changed a diesel pumping system by an wind one, It´s the first community system of this nature in Bahia. Facing problems with the model, a Cerb involved the academic segment of the Federal Center of Technological Education of Bahia Cefetba looking for a solution. This work intends to demonstrate the possibilities of optimization of the pumping communit system that supply water to approximately 50 people in the place of Romão, municipal district of São Gabriel-Ba. Technical reports were published in AGRENERGD2004-Unicamp SP and Scientific Magazine ETC,Cefetba, 2005. A simulation of the increase of energy is presented for heights of 15 and 20m, considering the eletromecanical balance from the pumping energy to the wind turbine. From the accomplished bibliographical revision, we emphasized the mechanical aspects of the engineering once in UFRN, those studies concentrate on the Department of Mechanical Engineering while, in others eletroelectronic are more emphasized. Finally, documents that we judged important were enclosed for the perfect understanding of this work

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Neste trabalho, ajustou-se um modelo matemático para quantificar o efeito da variação do rendimento da bomba hidráulica na variação dos custos de um sistema de bombeamento, na estrutura tarifária horossazonal verde (subgrupo A4) e o tempo de recuperação do capital investido no equipamento de maior rendimento. em seguida, o mesmo foi aplicado a um sistema de bombeamento para suprimento de um sistema de irrigação do tipo pivô central. As opções de rendimento da bomba hidráulica foram: 69,5% (bomba 1), 73% (bomba 2) e 78% (bomba 3), cujos custos de aquisição foram, respectivamente, R$ 6.176,00, R$ 8.479,00 e R$ 15.509,00. Os resultados da aplicação do modelo mostraram que: i) a substituição da bomba 1 pela bomba 2 foi viável, sendo o período de recuperação de capital 3,4 anos; ii) a substituição da bomba 1 pela bomba 3 foi viável, sendo o período de recuperação de capital 9,2 anos; iii) a substituição da bomba 2 pela bomba 3 foi inviável, sendo o período de recuperação de capital 21,1 anos superior ao período de amortização do investimento na avaliação econômica, considerado 15 anos.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Despite the emergence of other forms of artificial lift, sucker rod pumping systems remains hegemonic because of its flexibility of operation and lower investment cost compared to other lifting techniques developed. A successful rod pumping sizing necessarily passes through the supply of estimated flow and the controlled wear of pumping equipment used in the mounted configuration. However, the mediation of these elements is particularly challenging, especially for most designers dealing with this work, which still lack the experience needed to get good projects pumping in time. Even with the existence of various computer applications on the market in order to facilitate this task, they must face a grueling process of trial and error until you get the most appropriate combination of equipment for installation in the well. This thesis proposes the creation of an expert system in the design of sucker rod pumping systems. Its mission is to guide a petroleum engineer in the task of selecting a range of equipment appropriate to the context provided by the characteristics of the oil that will be raised to the surface. Features such as the level of gas separation, presence of corrosive elements, possibility of production of sand and waxing are taken into account in selecting the pumping unit, sucker-rod strings and subsurface pump and their operation mode. It is able to approximate the inferente process in the way of human reasoning, which leads to results closer to those obtained by a specialist. For this, their production rules were based on the theory of fuzzy sets, able to model vague concepts typically present in human reasoning. The calculations of operating parameters of the pumping system are made by the API RP 11L method. Based on information input, the system is able to return to the user a set of pumping configurations that meet a given design flow, but without subjecting the selected equipment to an effort beyond that which can bear

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Neste trabalho apresenta-se o estudo do desenvolvimento de um controlador não-tradicional baseado em um mecanismo de histerese com auto-ajuste para o controle de nível de líquido de um sistema de separação e bombeio submarino conhecido como VASPS. O controlador desenvolvido gera sinais enviados para a bomba centrífuga submersa para controlar o nível de líquido no tanque do separador, evitando que ele atinja valores muito baixos que poderiam danificar a bomba ou valores muito altos que reduziriam a eficiência da separação líquido/gás. Os sinais de controle gerados pelo controlador visam solicitar a bomba o mínimo possível de modo a evitar o seu desgaste e falhas prematuras. Nas simulações, o controlador desenvolvido foi testado sob grandes variações nas condições de operação, tais como golfadas, produzindo resultados bastante satisfatórios e promissores.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O objetivo desta dissertação é desenvolver uma ferramenta computacional para a análise do potencial de bombeamento de água com base nos valores de velocidades de vento de uma localidade, utilizando um aerogerador de pequeno porte acoplado a um conjunto motobomba convencional, por intermédio de um inversor de frequência. No trabalho são apresentados dois métodos para o cálculo da vazão. O método 1 utiliza um modelo teórico, enquanto que no método 2 o modelamento é feito a partir de dados de bombeamento obtidos em laboratório. Os dois métodos descrevem o funcionamento de um sistema de bombeamento de água envolvendo os equipamentos citados. Utilizando os modelos matemáticos descritos, foi criado um programa em linguagem Delphi®, para a obtenção dos valores de vazão e volume de água bombeada, além do número de pessoas que podem ser atendidas, com base nos dados de velocidade de vento do local, para com isso, ser possível analisar a viabilidade ou não de instalação do sistema. O funcionamento do programa é descrito através de um exemplo, que contém valores reais de velocidade de vento, e cujos resultados são analisados de forma a possibilitar seu entendimento.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Zootecnia - FMVZ

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Energia na Agricultura) - FCA

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The anaerobic treatment of sewage is widely employed in Brazil and it is an appreciated way for the treatment of effluents, helping to reduce the environmental impact in rivers. The methane gas obtained from the process can be applied to improve the energetic efficiency of the system, reducing the amount of waste and the cost of the treatment process. This work presents the net energy balance of anaerobic reactors applied to the treatment of sewage. The analysis was performed considering full-scale and laboratory-scale treatment systems. In laboratory scale, the results from three kinds of systems were compared regarding the biological treatment of greywater. Two of them (UASB7 and UASB12) were anaerobic and the other one was a combined anaerobic-aerobic system (UASB7/SBR6). Greywater methanization (compared to theoretical maximum) was calculated considering 100% removal (g BOD/day), the literature percentage removal and the anionic surfactant presence in the effluentt. For each of these three cases, the efficiencies were, respectively, 16.9%, 43.6% and 51.3% in UASB7 reactor, 25.6%, 50.3% and 59.2% in UASB12 reactor and 30.6%, 61.2% and 71.9% in UASB7/SBR6 reactor. The energetic potential was found to be 4.66x10-4, 7.77x10-4 and 5.12x10-4 kWh/L for the UASB7, UASB12 and UASB7/SBR6 reactors, respectively. The pumping system, the aeration (in the anaerobic-aerobic system) and the temperature controlled heating system were considered to calculate the energetic consumption. However, the third one was not employed since tropical regions like Brazil do not need heating systems and also because of its high energetic consumption. The calculated net energy balance in the reactors was negative in the case of greywater, respectively -0.16, -0.28 and -0.18 kWh/L for the reactors UASB7, UASB12 and UASB7/SRB6. In full scale (ETE Jardim das Flores - Rio Claro, SP), the average energy... (Complete abstract click electronic access below)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

On the field of the projects of hydraulic systems exists a lot of worries when we talk about the calculate of hydraulic pumps. In this case some facts must be considerate: length of tubes, fluid characteristics, height gauge, temperature, pressure, characteristics of tubes, flow required and others. For that mathematic calculates must be developed with the objective to optimize hydraulic pumps and agree to find an ideal machine (that don't requires more energy than necessary or less energy than it requires; that is the more critical case, cause exists the risk that the fluid pumped do not agree to become in your destiny). The wrong calculate of this machine can super-size its, bringing an excessive energy consumption. Actually it's an important subject because we are in the age of lack of energy what turn it more expensive. So the correct sizing of a hydraulic pump is connected with the fact that you have to uses the enough energy resources avoiding waste. The calculate of ideal pump in the pumping system is studied during years and a lot of specialists in this subject develop equations and theories to calculate its. Some researches study about this subject and all of them become to the same conclusion: to find the ideal pump we have to know the characteristics of fluid (cinematic viscosity), the required flow , overall yield (overall of motor x overall of pump) the high gauge or discharge pressure and the loss of repression. The pressure drop can be calculated with different theories: using Hazen-Williams, Darcy e Weisbach or Chézy (1775 - that starts the researches to calculate the pressure drop). Although the most used theory and what is most near to reality is the Darcy's equation. So, in this job the Darcy's equation were choice to calculate the drop pressure that consider what kind of flow we are studying: laminar or turbulent. The determination of the best pump to be used in the ... ( complete abstract click eletronic access below)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study is about a heating line that uses thermal oil. It is located in a facility that produces interlayers used in cars windshields. A plastic resin is melted and is sent to a matrix called DIE where the interlayers are produced. The DIE needs to receive heat from the circulation of thermal oil in four different regions of its interior, to ensure the correct thickness of the interlayer. The thermal energy is provided by electric heaters and the flow of thermal oil is impelled by four mechanically sealed centrifugal pumps (one per region). The key point of this study is the fact that these four pumps of the system have reported successive failures in the mechanical seals. Apparently, a poorly designed project has burdened the system intermittently. The pumps operation condition is located in a region of low efficiency, according to the characteristic curves. This fact is the source of the noticeable reduced time between failures. Changes in the configuration of the facility and in the number of pumps will be proposed, aiming to achieve higher operational efficiency. The proposals will be mathematically analyzed according to the Hydraulic Institute criteria. At the same time, we will also keep focus on an in-depth study of a heating system structure, starting with a detailed approach for each component and discussion about its real need and economic viability. At the end of this paper it is shown that the gain in efficiency achieved with the new proposed configuration reflects not only in the reduction of maintenance costs, but also a potential improvement in energy efficiency. It is shown that these two aspects are closely related and together form the basis for the design of a reliable and efficient pumping system

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Civil e Ambiental - FEB

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)