999 resultados para Protese dentaria total : Materiais de moldagem


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Reabilitação Oral - FOAR

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aiming to investigate in vitro the behavior of esthetic veneers placed in crows and made of the laboratory resins Artglass and Targis when submitted to insertion and removal of circunferential cobalt-chromium clasps, 24 veneer crowns were made (twelve with Artglass (Heraeus Kulzer) and twelve with Targis (Ivoclar Vivadent)), as well as the respective cobalt-chromium clasps. The crowns were then submitted to five thousand cycles of clasps insertion and removal, using a proper device. Using the verification of the force necessary to remove the clasps over the crowns during the experiment, the clasps and crowns mass variation, and the macroscopic inspection of the veneers, one may conclude that the veneers did not show a significant variation of the force required to remove the clasps over the crowns; they show a little amount of abrasion, possible to detect using a visual inspection and they show a little and variable amount of mass loss, less for that made with Artglass (average of 0,002g) and greater for that made with Targis (average of 0,006g)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Um bloco de poliuretano recebeu três implantes de hexagono externo, no posicionamento compensado. Para cada implante foi conectado o pilar protético microunit. Foram realizados cinco enceramentos com três coifas plásticas cada um, que foram fundidos em monobloco numa liga de cobalto-cromo. Foram colados quatro extensomêtros tangenciando cada implante, sendo dois extensomêtros para o implante central. Após o acabamento, as estruturas foram fixadas nos respectivos locais com o parafuso de retenção com torque de 10 Ncm, obtidos com um torquímetro. Para aplicação de carga sobre os corpos-de-prova foram selecionados cinco pontos de aplicação de carga. O dispositivo de aplicação de carga–DAC foi utilizado 30 kg de cargas verticais estáticas, empregando uma ponta esférica de 2 mm de diamêtro, durante 10 segundos em cada um dos pontos estabelecidos, sendo, neste instante registradas as micro deformações de cada extensômetro. Foi utilizado o teste de análise de variância T Student e o nível de significância foi o valor convencional de 5%. Para cada implante foi analisada a microdeformação ocorrida. Os resultados obtidos mostraram que houve uma diferença estatisticamente significativa entre os pontos não-axiais D e E (t = 5,21 df = 4, p = 0,006 < 0,05) e não foi estatisticamente significativa para os dados axial entre os pontos B e C (t = 6, 57, df = 4, p = 0,003 < 0,05 / 3). Conclui-se que,a aplicação de carga ao redor de três implantes de hexágono externo no posicionamento compensado,mostra que os pontos não-axiais sofrem maior micro deformação do que os pontos axiais

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present study aims at evaluating dimensional alteration of stone casts made from impressions with a standard irreversible hydrocolloid and an antimicrobial one. For this, an alginate without disinfectant (Type II Jeltrate) and other containing chlorhexidine (Type II Avagel) were used, which rose by the same regime of treatment: without disinfection; immersion; and spraying. A 1% sodium hypochlorite solution was used for 10 minutes. To obtain the impressions, a perforated impression tray was made from a standard metal model. After molding, the molds were washed in running water for 30 seconds to simulate removal of saliva. Then, with the exception of the control group, these molds were subjected to disinfection treatment. After 10 minutes they were washed again. 60 samples poured with type V special gypsum (Durone) were obtained, that were measured 3 times in a stereomicroscope (SZX12, Olympus) to record the average of dimensional alterations. The disinfection treatment did not bring significant changes in the models obtained from both alginate tested (standard p = 0.7102; with chlorhexidine p = 0.5832). The results showed a statistically significant and additional advantage of the traditional alginate on alginate with chlorhexidine, with respect to dimensional alteration (p < 0.05).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The dental trade has offered dental impression and dental stone for orthodontic use ensuring accurate models. The compatibility between these materials is defined by the wetting of the model surfaces by the mixture water/stone poured over it and the influenced by the method of disinfection of model and disinfectant solution used. It was evaluated the influence of spray disinfection with sodium hypochlorite 1% on the wettability of two commercial alginate (Jeltrate ® - Dentsply and Orthoprint ® - Zhermack) at two commercial type III gypsum (Rio ® - ME and AOBussoli Orthogesso Orthogesso ®-SA). Twenty models were fabricated for each type of alginate, which were divided into two groups (water and sodium hypochlorite), receiving respectively water and sodium hypochlorite 1% spray. Each group of models was then further divided into two subgroups, and on their surface were poured 2 ml of type III gypsum (Gesso Rio® or Orthogesso®). Reached the final setting of the gypsum specimens were sectioned vertically and medially, settled water with sandpaper No. 400 and mounted on suitable device for reading (in the right and left) of the contact angle Carl Zeiss microscope (precision, 001). The results were submitted to ANOVA and founded statistical significance for solutions used. It was concluded that sodium hypochlorite spray improved wettability of alginates studied.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The cares at the manipulation of the alginate (condensation, disinfection of the impression and the time elapsed until the leak of the plaster) deserve special attention considering the great amount of distortions occurring every time the impression is not fill of plaster in a brief space of time and appropriate storage conditions. Besides its adaptation to the plaster suffers influence of the events happened after the impression is removed of the mouth. The purpose of this research was to evaluate the wetting capacity of three brands of alginate (Jeltrate™,Hydrogum™ e Orthoprint™) by the plaster type III (Rio™) under the influence of disinfection by sodium hypochlorite 1% sprays and the time of storage of 15 minutes,30 minutes, 1 hour, 6, 12 and 24 hours. There were made 60 impressions of each brand of alginate divided in two groups (water and sodium hypochlorite 1%) rearranged after the application of the sodium hypochlorite spray according to the storage time (15 or 30 minutes and 1,6,12, or 24 hours). On the surface of the impressions 2ml of plaster were flowed, proportioned and condensed in agreement with manufacturer‘s instructions. After the final setting expansion the casts were sectioned vertically and medially, regularized at the cut surface (emery paper 400) and setted for reading the contact angle at the microscope Carl Zeiss. The obtained results, submitted to statistical treatment (ANOVA) revealed significant differences when compared the employed solutions (water and sodium hypochlorite 1%) and the time of storage. The sodium hypochlorite 1% exhibited the smallest contact angles and the times of storage of 15 minutes and 6 hours the smallest and larger angles, respectively. It can be concluded that the alginate impressions exhibited larger adaptation to the plaster when disinfected by hypochlorite of sodium 1% and stocked by 15 minutes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The activities developed in health area are of great importance, because they have the aim to preserve the life of the men, and therefore, must be performed by authorized persons. The increase of the number of dental schools, the decline at the education quality and a higher admission of students with low ability to exercise their profession, are facts that bring disastrous consequences for society. These facts are, also, reflected at the moral, ethical and technical-scientific performance of the professional. The purpose of this clinic case is to show that although there is a significant suplly of education institutions, there is a lack of scientific and adequate technical knowledgement from the graduated dentals surgeons. The patient MSL, 17 year old, female, went to a dental clinic presenting a tray type Vernis, attached to the lower arch. After clinical evaluation, it was showed that an incorrect material was used for the impression technique, being impossible to take out the tray by the conventional manner. The planning for the removal of the tray was through the divide of it. Thus, the consequence of the lack of knowledge in the use of impression materials had caused a great incovinience to the patient. It can be concluded that the rate of malpractice is directly related to the professional preparation, highlighting the importance of quality dental education for a responsible clinical practice.