992 resultados para Pressure biofeedback unit
Resumo:
An eclogite facies meta-plagiogranite from the Lanzo massif (western Alps, Italy) contains crystals of zircon intimately associated with allanite. Zircon displays different microtextures ranging from pristine, euhedral, and magmatic to fractured, porous varieties with mosaic zoning, and pervasive recrystallization into euhedral microcrystals. Fractures and voids in the recrystallized zircon microcrystals are mainly filled by high-pressure Na-rich pyroxene. Electron backscattered diffraction analysis revealed a similar crystallographic orientation for primary magmatic zircon crystals and microcrystals, with less than 2 degrees misorientation among neighboring microdomains. The textural change is coupled with chemical and isotopic modifications: recrystallized zircon domains contain significantly less Th and light- to mid-REE, but are richer in Sr than magmatic zircon crystals. Magmatic zircon preserves the protolith U-Pb age of 163.5 +/- 1.7 Ma, whereas zircon microcrystals have a mean age of 55 +/- 1 Ma. The coexisting allanite also contains inclusions of Na-rich pyroxene and has chemical features (elevated Sr and Ni contents and lack of Eu anomaly) indicating formation at high pressure. Despite being associated texturally with zircon, allanite yields a younger Th-Pb age of 46.5 +/- 3.0 Ma, suggesting that the Lanzo unit remained at relatively high pressure conditions for similar to 8 m.y. Zircon recrystallization proceeded with volume reduction and loss of material to an alkaline metamorphic fluid that acted as the agent for a coupled dissolution-reprecipitation process. Recrystallization occurred with minimum transport, in a low-strain environment, and was not significantly enhanced by metamictization. The source of the fluid for zircon recrystallization is most probably related to prograde devolatilization reactions in the surrounding serpentinite.
Resumo:
La rigidité anormalement haute des artères à grande conductance est un marqueur de l'augmentation du risque cardiovasculaire et est typiquement retrouvée chez les patients diabétiques ou hypertendus. Ces vaisseaux deviennent plus rigides avec l'âge, expliquant la haute prévalence d'hypertension systolique chez les personnes âgées. Cette rigidification agit sur la pression sanguine de plusieurs façons. Notamment la fonction windkessel est gênée, menant à l'augmentation de la pression systolique et de la pression puisée, la diminution de la pression diastolique, et ainsi à l'augmentation de la postcharge ventriculaire gauche associée à une probable diminution de la perfusion coronarienne. De plus, la propagation des ondes de pression le long de l'arbre vasculaire est accélérée, de sorte que les ondes réfléchies générées au site de décalage d'impédance atteignent l'aorte ascendante plus tôt par rapport au début de l'éjection ventriculaire, aboutissant à une augmentation de la pression systolique centrale, ce qui n'arriverait pas en présence de vaisseaux moins rigides. Dans ce cas, au contraire, les ondes de pression antérogrades et réfléchies voyages plus lentement, de sorte que les ondes de réflexion tendent à atteindre l'aorte centrale une fois l'éjection terminée, augmentant la pression diastolique et contribuant à la perfusion coronarienne. La tonométrie d'applanation est une méthode non invasive permettant l'évaluation de la forme de l'onde de pression au niveau l'aorte ascendante, basée sur l'enregistrement du pouls périphérique, au niveau radial dans notre étude. Nous pouvons dériver à partir de cette méthode un index d'augmentation systolique (sAIX) qui révèle quel pourcentage de la pression centrale est du aux ondes réfléchies. Plusieurs études ont montré que cet index est corrélé à d'autres mesures de la rigidité artérielle comme la vitesse de l'onde de pouls, qu'il augmente avec l'âge et avec les facteurs de risques cardiovasculaires, et qu'il est capable de préciser le pronostic cardiovasculaire. En revanche, peu d'attention a été portée à l'augmentation de la pression centrale diastolique due aux ondes réfléchies (dAIX). Nous proposons donc de mesurer cet index par un procédé d'analyse développé dans notre laboratoire, et ce dans la même unité que l'index systolique. Etant donné que les modifications de la paroi artérielle modulent d'une part la vitesse de l'onde de pouls (PWV) et d'autre part le temps de voyage aller-retour des ondes de pression réfléchies aux sites de réflexion, toute augmentation de la quantité d'énergie réfléchie atteignant l'aorte pendant la systole devrait être associée à une diminution de l'énergie arrivant au même point pendant la diastole. Notre étude propose de mesurer ces deux index, ainsi que d'étudier la relation de l'index d'augmentation diastolique (dAIX) avec la vitesse de propagation de l'onde de pouls (PWV) et avec le rythme cardiaque (HR), ce dernier étant connu pour influencer l'index d'augmentation systolique (sAIX) . L'influence de la position couchée et assise est aussi étudiée. Les mesures de la PWV et des sAIX et dAIX est réalisée chez 48 hommes et 45 femmes âgées de 18 à 70 ans, classés en 3 groupes d'âges. Les résultats montrent qu'en fonction de l'âge, le genre et la position du corps, il y a une relation inverse entre sAIX et dAIX. Lorsque PWV et HR sont ajoutés comme covariables à un modèle de prédiction comprenant l'âge, le genre et la position du corps comme facteurs principaux, sAIX est directement lié à PWV (p<0.0001) et inversement lié à HR (p<0.0001). Avec la même analyse, dAIX est inversement lié à PWV (p<0.0001) et indépendant du rythme cardiaque (p=0.52). En conclusion, l'index d'augmentation diastolique est lié à la rigidité vasculaire au même degré que l'index d'augmentation systolique, alors qu'il est affranchi de l'effet confondant du rythme cardiaque. La quantification de l'augmentation de la pression aortique diastolique due aux ondes réfléchies pourrait être une partie utile de l'analyse de l'onde de pouls.
Resumo:
OBJECTIVE: To evaluate the feasibility and effects of non-invasive pressure support ventilation (NIV) on the breathing pattern in infants developing respiratory failure after extubation. DESIGN: Prospective pilot clinical study; each patient served as their own control. SETTING: A nine-bed paediatric intensive care unit of a tertiary university hospital. PATIENTS: Six patients (median age 5 months, range 0.5-7 months; median weight 4.2 kg, range 3.8-5.1 kg) who developed respiratory failure after extubation. INTERVENTIONS: After a period of spontaneous breathing (SB), children who developed respiratory failure were treated with NIV. MEASUREMENTS AND RESULTS: Measurements included clinical dyspnoea score (DS), blood gases and oesophageal pressure recordings, which were analysed for respiratory rate (RR), oesophageal inspiratory pressure swing (dPes) and oesophageal pressure-time product (PTPes). All data were collected during both periods (SB and NIV). When comparing NIV with SB, DS was reduced by 44% (P < 0.001), RR by 32% (P < 0.001), dPes by 45% (P < 0.01) and PTPes by 57% (P < 0.001). A non-significant trend for decrease in PaCO(2) was observed. CONCLUSION: In these infants, non-invasive pressure support ventilation with turbine flow generator induced a reduction of breathing frequency, dPes and PTPes, indicating reduced load of the inspiratory muscles. NIV can be used with some benefits in infants with respiratory failure after extubation.
Pulse pressure variation-guided fluid therapy after cardiac surgery: A pilot before-and-after trial.
Resumo:
PURPOSE: The aim of this study is to study the feasibility, safety, and physiological effects of pulse pressure variation (PPV)-guided fluid therapy in patients after cardiac surgery. MATERIALS AND METHODS: We conducted a pilot prospective before-and-after study during mandatory ventilation after cardiac surgery in a tertiary intensive care unit. We introduced a protocol to deliver a fluid bolus for a PPV ≥13% for at least >10 minutes during the intervention period. RESULTS: We studied 45 control patients and 53 intervention patients. During the intervention period, clinicians administered a fluid bolus on 79% of the defined PPV trigger episodes. Median total fluid intake was similar between 2 groups during mandatory ventilation (1297 mL [interquartile range 549-1968] vs 1481 mL [807-2563]; P = .17) and the first 24 hours (3046 mL [interquartile range 2317-3982] vs 3017 mL [2192-4028]; P = .73). After adjusting for several baseline factors, PPV-guided fluid management significantly increased fluid intake during mandatory ventilation (P = .004) but not during the first 24 hours (P = .47). Pulse pressure variation-guided fluid therapy, however, did not significantly affect hemodynamic, renal, and metabolic variables. No serious adverse events were noted. CONCLUSIONS: Pulse pressure variation-guided fluid management was feasible and safe during mandatory ventilation after cardiac surgery. However, its advantages may be clinically small.
Resumo:
INTRODUCTION: Cefepime has been associated with a greater risk of mortality than other beta-lactams in patients treated for severe sepsis. Hypotheses for this failure include possible hidden side-effects (for example, neurological) or inappropriate pharmacokinetic/pharmacodynamic (PK/PD) parameters for bacteria with cefepime minimal inhibitory concentrations (MIC) at the highest limits of susceptibility (8 mg/l) or intermediate-resistance (16 mg/l) for pathogens such as Enterobacteriaceae, Pseudomonas aeruginosa and Staphylococcus aureus. We examined these issues in a prospective non-interventional study of 21 consecutive intensive care unit (ICU) adult patients treated with cefepime for nosocomial pneumonia. METHODS: Patients (median age 55.1 years, range 21.8 to 81.2) received intravenous cefepime at 2 g every 12 hours for creatinine clearance (CLCr) >or= 50 ml/min, and 2 g every 24 hours or 36 hours for CLCr < 50 ml/minute. Cefepime plasma concentrations were determined at several time-points before and after drug administration by high-pressure liquid chromatography. PK/PD parameters were computed by standard non-compartmental analysis. RESULTS: Seventeen first-doses and 11 steady states (that is, four to six days after the first dose) were measured. Plasma levels varied greatly between individuals, from two- to three-fold at peak-concentrations to up to 40-fold at trough-concentrations. Nineteen out of 21 (90%) patients had PK/PD parameters comparable to literature values. Twenty-one of 21 (100%) patients had appropriate duration of cefepime concentrations above the MIC (T>MIC >or= 50%) for the pathogens recovered in this study (MIC <or= 4 mg/l), but only 45 to 65% of them had appropriate coverage for potential pathogens with cefepime MIC >or= 8 mg/l. Moreover, 2/21 (10%) patients with renal impairment (CLCr < 30 ml/minute) demonstrated accumulation of cefepime in the plasma (trough concentrations of 20 to 30 mg/l) in spite of dosage adjustment. Both had symptoms compatible with non-convulsive epilepsy (confusion and muscle jerks) that were not attributed to cefepime-toxicity until plasma levels were disclosed to the caretakers and symptoms resolved promptly after drug arrest. CONCLUSIONS: These empirical results confirm the suspected risks of hidden side-effects and inappropriate PK/PD parameters (for pathogens with upper-limit MICs) in a population of ICU adult patients. Moreover, it identifies a safety and efficacy window for cefepime doses of 2 g every 12 hours in patients with a CLCr >or= 50 ml/minute infected by pathogens with cefepime MICs <or= 4 mg/l. On the other hand, prompt monitoring of cefepime plasma levels should be considered in case of lower CLCr or greater MICs.
Resumo:
Positive pressure ventilation (PPV) is a frequent intervention in the neonatal intensive care unit. This article is directed towards paediatricians in training and attempts to cover the basics of PPV without being too technical. To do so we have employed an extensive use of graphics to illustrate the underlying principles.
Resumo:
OBJECTIVES: We have sought to develop an automated methodology for the continuous updating of optimal cerebral perfusion pressure (CPPopt) for patients after severe traumatic head injury, using continuous monitoring of cerebrovascular pressure reactivity. We then validated the CPPopt algorithm by determining the association between outcome and the deviation of actual CPP from CPPopt. DESIGN: Retrospective analysis of prospectively collected data. SETTING: Neurosciences critical care unit of a university hospital. PATIENTS: A total of 327 traumatic head-injury patients admitted between 2003 and 2009 with continuous monitoring of arterial blood pressure and intracranial pressure. MEASUREMENTS AND MAIN RESULTS: Arterial blood pressure, intracranial pressure, and CPP were continuously recorded, and pressure reactivity index was calculated online. Outcome was assessed at 6 months. An automated curve fitting method was applied to determine CPP at the minimum value for pressure reactivity index (CPPopt). A time trend of CPPopt was created using a moving 4-hr window, updated every minute. Identification of CPPopt was, on average, feasible during 55% of the whole recording period. Patient outcome correlated with the continuously updated difference between median CPP and CPPopt (chi-square=45, p<.001; outcome dichotomized into fatal and nonfatal). Mortality was associated with relative "hypoperfusion" (CPP<CPPopt), severe disability with "hyperperfusion" (CPP>CPPopt), and favorable outcome was associated with smaller deviations of CPP from the individualized CPPopt. While deviations from global target CPP values of 60 mm Hg and 70 mm Hg were also related to outcome, these relationships were less robust. CONCLUSIONS: Real-time CPPopt could be identified during the recording time of majority of the patients. Patients with a median CPP close to CPPopt were more likely to have a favorable outcome than those in whom median CPP was widely different from CPPopt. Deviations from individualized CPPopt were more predictive of outcome than deviations from a common target CPP. CPP management to optimize cerebrovascular pressure reactivity should be the subject of future clinical trial in severe traumatic head-injury patients.
Resumo:
Sixteen patients with refractory hypertension were submitted to vigorous sodium depletion while cardiovascular homeostasis was monitored with measurements of hormonal and hemodynamic parameters and repeat saralasin tests. This regimen resulted in a negative sodium balance by an average of 300 mEq. The loss of sodium closely correlated to the decrease of body weight (r = 0.70, p less than 0.005). Blood pressure (BP) decreased from 176/166 +/- 8/3 to 155/109 +/-6/3 mm Hg. There was a significant correlation between percent increments in plasma renin activity (PRA) and the rise in plasma norepinephrine (r = 0.68, p less than 0.05) and a close negative correlation between percent increase in PRA and the ratio of fall in mean blood pressure (MAP) per unit of weight loss (r = -0.73, p less than 0.005). Thus, patients with the least percent increase in PRA demonstrated the greatest fall in BP per unit of weight loss, indicating that relative rather than absolute elevation of renin may be the factor limiting antihypertensive efficacy of sodium depletion. Sodium depletion induced increase in peripheral resistance and decrease in cardiac output, both mostly attributable to relative hyperreninemia. Indeed, the adverse hemodynamic changes were reversed by angiotensin inhibition, during which BP normalized. It is concluded that vigorous sodium depletion complemented by angiotensin blockade or suppression with sympatholytic agents improves management of otherwise refractory hypertension.
Resumo:
The main objective of this article is to assess the risk factors and the types of surface for the development of pressure ulcers (PU) on critical ill patients in an Intensive Care Unit (ICU)
Resumo:
To evaluate the impact of noninvasive ventilation (NIV) algorithms available on intensive care unit ventilators on the incidence of patient-ventilator asynchrony in patients receiving NIV for acute respiratory failure. Prospective multicenter randomized cross-over study. Intensive care units in three university hospitals. Patients consecutively admitted to the ICU and treated by NIV with an ICU ventilator were included. Airway pressure, flow and surface diaphragmatic electromyography were recorded continuously during two 30-min periods, with the NIV (NIV+) or without the NIV algorithm (NIV0). Asynchrony events, the asynchrony index (AI) and a specific asynchrony index influenced by leaks (AIleaks) were determined from tracing analysis. Sixty-five patients were included. With and without the NIV algorithm, respectively, auto-triggering was present in 14 (22%) and 10 (15%) patients, ineffective breaths in 15 (23%) and 5 (8%) (p = 0.004), late cycling in 11 (17%) and 5 (8%) (p = 0.003), premature cycling in 22 (34%) and 21 (32%), and double triggering in 3 (5%) and 6 (9%). The mean number of asynchronies influenced by leaks was significantly reduced by the NIV algorithm (p < 0.05). A significant correlation was found between the magnitude of leaks and AIleaks when the NIV algorithm was not activated (p = 0.03). The global AI remained unchanged, mainly because on some ventilators with the NIV algorithm premature cycling occurs. In acute respiratory failure, NIV algorithms provided by ICU ventilators can reduce the incidence of asynchronies because of leaks, thus confirming bench test results, but some of these algorithms can generate premature cycling.
Resumo:
PURPOSE OF REVIEW: Multimodal monitoring (MMM) is routinely applied in neurointensive care. Unfortunately, there is no robust evidence on which MMM-derived physiologic variables are the most clinically relevant, how and when they should be monitored, and whether MMM impacts outcome. The complexity is even higher because once the data are continuously collected, interpretation and integration of these complex physiologic events into targeted individualized care is still embryonic. RECENT FINDINGS: Recent clinical investigation mainly focused on intracranial pressure, perfusion of the brain, and oxygen availability along with electrophysiology. Moreover, a series of articles reviewing the available evidence on all the MMM tools, giving practical recommendations for bedside MMM, has been published, along with other consensus documents on the role of neuromonitoring and electroencephalography in this setting. SUMMARY: MMM allows comprehensive exploration of the complex pathophysiology of acute brain damage and, depending on the different configuration of the pathological condition we are treating, the application of targeted individualized care. Unfortunately, we still lack robust evidence on how to better integrate MMM-derived information at the bedside to improve patient management. Advanced informatics is promising and may provide us a supportive tool to interpret physiologic events and guide pathophysiological-based therapeutic decisions.
Post-partum persistence of abnormal circadian pattern of blood pressure after preeclampsia [109-POS]
Resumo:
OBJECTIVES: Blunted nocturnal dip of blood pressure (BP) and reversed circadian rhythm have been described in preeclampsia (PE). Non-dipper status and preeclampsia are both associated with an increased risk of cardiovascular disease later in life. Complete recovery of BP in PE is reported to occur over a variable period of time. Twenty-four hours-ambulatory blood pressure measurement (ABPM) in the post-partum follow-up after a PE has not been described. The aim of this study was to assess 24h-ambulatory blood pressure pattern after a PE and to determine the prevalence of non-dipper status, nocturnal hypertension, white coat hypertension and masked hypertension. METHODS: This is an observational, prospective study on women who suffered from a preeclampsia. A 24h-ABPM was done 6 weeks post-partum at the Hypertension Unit of the University Hospitals of Geneva, concomitantly with a clinical and biological evaluation. RESULTS: Forty-five women were included in a preliminary analysis. Mean age was 33±6years, 57.3% were Caucasian, mean BMI before pregnancy was 24±5kg/m(2). Office and ambulatory BP are shown in Table 1. Prevalence of nocturnal hypertension was high and half of the women had no nocturnal dipping. The diagnosis of hypertension based on office BP was discordant with the diagnosis based on ABPM in 25% of women. CONCLUSIONS: The prevalence of increased nighttime BP and abnormal BP pattern is high at 6weeks post-partum in preeclamptic women. Early assessment of BP with ABPM after preeclampsia allows an early identification of women with persistent circadian abnormalities who might be at increased risk. It also provides a more accurate assessment than office BP. DISCLOSURES: A. Ditisheim: None. B. Ponte: None. G. Wuerzner: None. M. Burnier: None. M. Boulvain: None. A. Pechère-Bertschi: None.
Resumo:
Among the numerous approaches to food waste treatment, the food waste disposers method (FWDs), as a newcomer, has become slowly accepted by the general public owing to the worries about its impact on the existing sewage system. This paper aims to justify the role of FWDs in the process of urbanization in order to better prepare a city to take good care of the construction of its infrastructure and the solid waste treatment. Both the literatures and the case study help to confirm that FWDs has no negative effects on the wastewater treatment plant and it is also environmental friendly by reducing the greenhouse gas emissions. In the case study, the Lappeenranta waste water treatment plant has been selected in order to figure out the possible changes to a WWTP following the integration of FWDs: the observation shows only minor changes take place in a WWTP, in case of 25% application, like BOD up 7%, TSS up 6% and wastewater flowrate up 6%, an additional sludge production of 200 tons per year and the extra yield of methane up to 10000m3 per year; however, when the utilization rate of FWD is over 75%, BOD, TSS, and wastewater flowrate will experience more significant changes, thus exerting much pressure on the existing WWTP. FWDs can only be used in residential areas or cities equipped with consummate drainage network within the service sphere of WWTP, therefore, the relevant authority or government department should regulate the installation frequency of FWDs, while promoting the accessory application of FWDs. In the meanwhile, WWTP should improve their treatment process in order to expand their capacity for sludge treatment so as to stay in line with the future development of urban waste management.
Resumo:
When using appropriate inflation pressures and load capacity (ballast), it may obtain a higher yield and prolongation of the life of the tire, besides it may minimize the problems of loss of traction, increased slippage and fuel consumption. This study aimed to evaluate the fuel consumption of a tractor operating with new and worn tires in three conditions of ballasting and three inflation pressures, when driving on compacted soil with vegetation cover. The experiment was conducted at the experimental unit from the Department of Animal Science, Federal University of Lavras, state of Minas Gerais, Brazil, in an agricultural soil compacted by cattle trampling and with vegetation cover. It was used a tractor 4x2 with front wheel assist, of a 65.62 kW engine power. The tires were of R1 type, diagonal (front: 12.4 to 24; and rear: 18.4 to 30), the average height of the clutches of the new tires were 0.3 and 0.35 m for front and rear tires, respectively, and for the worn tires were 0.018 and 0.0045 m, for the front and the rear tires, respectively. The results showed advantages for the tractor equipped with new tires.
Resumo:
Several methods have been described to measure intraocular pressure (IOP) in clinical and research situations. However, the measurement of time varying IOP with high accuracy, mainly in situations that alter corneal properties, has not been reported until now. The present report describes a computerized system capable of recording the transitory variability of IOP, which is sufficiently sensitive to reliably measure ocular pulse peak-to-peak values. We also describe its characteristics and discuss its applicability to research and clinical studies. The device consists of a pressure transducer, a signal conditioning unit and an analog-to-digital converter coupled to a video acquisition board. A modified Cairns trabeculectomy was performed in 9 Oryctolagus cuniculus rabbits to obtain changes in IOP decay parameters and to evaluate the utility and sensitivity of the recording system. The device was effective for the study of kinetic parameters of IOP, such as decay pattern and ocular pulse waves due to cardiac and respiratory cycle rhythm. In addition, there was a significant increase of IOP versus time curve derivative when pre- and post-trabeculectomy recordings were compared. The present procedure excludes corneal thickness and error related to individual operator ability. Clinical complications due to saline infusion and pressure overload were not observed during biomicroscopic evaluation. Among the disadvantages of the procedure are the requirement of anesthesia and the use in acute recordings rather than chronic protocols. Finally, the method described may provide a reliable alternative for the study of ocular pressure dynamic alterations in man and may facilitate the investigation of the pathogenesis of glaucoma.