886 resultados para Postmortem photography


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The development of new medical devices, such as aortic valves, requires numerous preliminary studies on animals and training of personnel on cadavers before the devices can be used in patients. Postmortem circulation, a technique used for postmortem angiography, allows the vascular system to be reperfused in a way similar to that in living persons. This technique is used for postmortem investigations to visualize the human vascular system and to make vascular diagnoses. Specific material for reperfusing a human body was developed recently. Our aim was to investigate whether postmortem circulation that imitates in vivo conditions allows for the testing of medical materials on cadavers. We did this by delivering an aortic valve using minimally invasive methods. Postmortem circulation was established in eight corpses to recreate an environment as close as possible to in vivo conditions. Mobile fluoroscopy and a percutaneous catheterization technique were used to deliver the material to the correct place. Once the valve was implanted, the heart and primary vessels were extracted to confirm its position. Postmortem circulation proved to be essential in several of the cadavers because it helped the clinicians to deliver the material and improve their implantation techniques. Due to the intravascular circulation, sites with substantial arteriosclerotic stenosis could be bypassed, which would have been impossible without perfusion. Although originally developed for postmortem investigations, this reperfusion technique could be useful for testing new medical devices intended for living patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aims of this study were to assess whether high-mobility group box-1 protein can be determined in biological fluids collected during autopsy and evaluate the diagnostic potential of high-mobility group box-1 protein in identifying sepsis-related deaths. High-mobility group box-1 protein was measured in serum collected during hospitalization as well as in undiluted and diluted postmortem serum and pericardial fluid collected during autopsy in a group of sepsis-related deaths and control cases with noninfectious causes of death. Inclusion criteria consisted of full biological sample availability and postmortem interval not exceeding 6h. The preliminary results indicate that high-mobility group box-1 protein levels markedly increase after death. Concentrations beyond the upper limit of the calibration curve were obtained in undiluted postmortem serum in septic and traumatic control cases. In pericardial fluid, concentrations beyond the upper limit of the calibration curve were found in all cases. These findings suggest that the diagnostic potential of high-mobility group box-1 protein in the postmortem setting is extremely limited due to molecule release into the bloodstream after death, rendering antemortem levels difficult or impossible to estimate even after sample dilution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Postmortem angiography is becoming increasingly essential in forensic pathology as an adjunct to conventional autopsy. Despite the numerous advantages of this technique, some questions have been raised regarding the influence of the contrast agent injected on the results of toxicological and biochemical analyses. The aim of this study was to investigate the effect of the injection of the contrast agent Angiofil®, mixed with paraffin oil, on the results of postmortem biochemical investigations performed on vitreous humor. Postmortem biochemical investigations were performed on vitreous samples collected from bodies that had undergone postmortem angiography (n=50) and from a control group (n=50). Two vitreous samples were analyzed for each group and the results compared. Glucose, urea, creatinine, 3-β-hydroxybutyrate, sodium and chloride were tested. Different values were observed between the first and second samples in each group. However, these differences were not clinically relevant, suggesting that the injection of this contrast agent mixture does not modify the concentration of the analyzed substances in the vitreous humor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Urea nitrogen, creatinine, and uric acid are relatively stable in postmortem serum and may, therefore, be used for diagnostic purposes when chronic kidney disease and end-stage renal failure are investigated as causes of death. Nevertheless, uncertainties remain in defining the best alternative to postmortem serum for the identification and assessment of significantly decreased kidney function. In this study, we investigated urea nitrogen, creatinine, and uric acid levels in postmortem serum, pericardial fluid, and vitreous humor in a series of medico-legal cases (500 autopsies) with various causes of death. No postmortem interval-related differences were observed in any of the investigated fluids for any analyzed parameter, confirming the biochemical stability of all compounds after death. Data analysis failed to reveal statistically significant differences between postmortem serum and pericardial fluid urea nitrogen, creatinine, and uric acid concentrations. Conversely, statistically significant differences were observed in all analyzed biomarkers between postmortem serum and vitreous humor levels, with lower concentrations of all markers measured in vitreous. The results of this study suggest that, in order to estimate as accurately as possible blood analyte concentrations at the time of death, pericardial fluid should be preferred to vitreous humor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sudden cardiac death is one of the most prevalent cause of death in developed countries. Its aetiology varies according to the age. Some cardiac diseases may explain sudden death with minimal or no anatomic findings. However, many cardiac diseases, as for example channelopathies and hypertrophic cardiomyopathy have a genetic basis. Therefore genetic analyses (molecular autopsy) are becoming a useful tool in forensic medicine to identify the cause of sudden cardiac death and to improve the early diagnosis of asymptomatic carriers among relatives.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Postmortem investigations are becoming more and more sophisticated. CT and MRI are already being used in pathology and forensic medicine. In this context, the impact of postmortem angiography increases because of the rapid evaluation of organ-specific vascular patterns, vascular alteration under pathologic and physiologic conditions, and tissue changes induced by artificial and unnatural causes. CONCLUSION: In this article, the advantages and disadvantages of former and current techniques and contrast agents are reviewed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new analytical approach for measuring methane in tissues is presented. For the first time, the use of in situ-produced, stably labelled CDH(3) provides a reliable and precise methane quantification. This method was applied to postmortem samples obtained from two victims to help determine the explosion origin. There was evidence of methane in the adipose tissue (82 nmol/g) and cardiac blood (1.3 nmol/g) of one victim, which corresponded to a lethal methane outburst. These results are discussed in the context of the available literature to define an analysis protocol for application in the event of a gas explosion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Saffaj et al. recently criticized our method of monitoring carbon dioxide in human postmortem cardiac gas samples using Headspace-Gas Chromatography-Mass Spectrometry. According to the authors, their demonstration, based on the latest SFSTP guidelines (established after 2007 [1,2]) fitted for the validation of drug monitoring bioanalytical methods, has put in evidence potential errors. However, our validation approach was built using SFSTP guidelines established before 2007 [3-6]. We justify the use of these guidelines because of the post-mortem context of the study (and not clinical) and the gaseous state of the sample (and not solid or liquid). Using these guidelines, our validation remains correct.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Vitreous glucose, blood beta-hydroxybutyrate and glycated hemoglobin were systematically measured in a series of 500 medico-legal autopsies in order to characterize the glycemic control during the weeks preceding death and identify ketoacidosis as the cause of death in diagnosed and unsuspected diabetics. Unenhanced CT-scans, histology and toxicology were performed in all cases. 16 cases of diabetic ketoacidosis were identified based on the results of all investigations. Among those, 13 cases concerned individuals with pre-existing diagnoses of diabetes mellitus whereas 3 cases concerned individuals with undiagnosed diabetes. A recent cocaine use was observed in 2 cases. C-reactive protein, interleukin-6 and interleukin-10 were measured and proved to be increased in all cases of diabetic ketoacidosis, whereas markers of generalized, bacterial infection and sepsis were normal in most of these cases. The results of this study highlight the usefulness of systematically performing biochemistry to identify ketoacidosis in unsuspected diabetics. It also emphasizes the role of toxicology and biochemistry to support the diagnosis of diabetic ketoacidosis and delineate the pathophysiological mechanisms that may disrupt the metabolic balance and finally lead to death in diabetic individuals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The concentrations of 3-beta-hydroxybutyrate (3HB) in femoral blood, urine, vitreous humor as well as pericardial and cerebrospinal fluids were retrospectively examined in a series of medico-legal autopsies, which included cases of diabetic ketoacidosis, hypothermia fatalities without ethanol in blood, bodies presenting mild decompositional changes, and sudden deaths in chronic alcoholics. Similar increases in 3HB concentrations were observed in blood, vitreous, and pericardial fluid, irrespective of the cause of death, suggesting that pericardial fluid and vitreous can both be used as alternatives to blood for postmortem 3HB determination. Urine 3HB levels were higher than blood values in most cases. Cerebrospinal fluid 3HB levels were generally lower than concentrations in blood and proved to be diagnostic of underlying metabolic disturbances only when significant increases occurred.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Pulmonary fat embolism (PFE) can be a cause of death in cases with trauma, during orthopedic surgery and also in non-traumatic conditions, such as burns, pancreatitis, fatty liver or sickle cell disease. As PMA becomes more widespread, it is important to determine how it affects the diagnosis of PFE. Aims: The aim of this study was to determine if the oily contrast liquid used in PMA induces artefactual PFE, if such artefacts differ from original PFE and if PFE can be detected and graded before PMA. Material and methods: Cases of adults without signs of postmortem change and for which an autopsy with angiography was performed were selected for this study. Pulmonary biopsies of each lung were taken before and after the angiography as were fragments of each lung with a twin-edged knife during the autopsy. The samples were examined under the microscope without fixation or staining and after an Oil-Red O staining. PFE was graded according to Falci et al. Results: Non-artefactual (original) PFE was diagnosed in 4 cases on pre-PMA biopsies. As expected, structures with the aspect of PFE were present in all cases after angiography. The microscopical aspect of original and PMA induced PFE was identical. Grading of the PFE according to Falci et al. was depending on the quality of the biopsies. Conclusions: PMA with oily contrast induces artefactual PFE that cannot be visually differentiated from original PFE. Original PFE can however be diagnosed with pre-angiography biopsies. In order to assure the diagnosis and correct grading of PFE, the quality of the biopsy should be checked before PMA with oily contrast.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to derive an index quantifying the state of alteration of cadavers by quantifying the presence of gas in the body using postmortem multidetector computed tomography (MDCT) imaging, and to validate the index by defining its sensitivity and specificity. The RA (radiological alteration)-index was derived from postmortem MDCT data from 118 nontraumatically deceased people. To validate the index, 100 additional scanned bodies (50 % traumatically deceased) were retrospectively examined by two independent observers. Presence of gas at 82 sites was assessed by a radiologist, whereas a forensic pathologist only investigated the seven sites used for the RA-index. The RA-index was highly correlated to the overall presence of gas in all 82 sites (R(2) = 0.98 in the derivation set and 0.85 in the validation set). Semiquantitative evaluation of gas presence in each site showed moderate reliability (Cohen's kappa range, 0.41-0.78); nevertheless, the overall RA-index was very reliable (ICC(2,1) = 0.95; 95 % CI 0.92-0.96). Examiner using the RA-index detected heart cavities full of gas with a sensitivity of 100 % (95 % CI 51.7-100) and a specificity of 98.8 % (92.6-99.9). We conclude that determining the presence of gas at seven sites is a valid means to measure the distribution of gas due to cadaveric alteration in the entire body. The RA-index is rapid, easy-to-use, and reliable for nonexperienced users, and it is a valid method to suspect the normal presence of gas from cadaveric alteration. MDCT can be used to screen for gas embolism and to give indications for gas composition analysis (gas chromatography).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The concentrations of 3-beta-hydroxybutyrate (3HB) in blood and two liver samples were retrospectively examined in a series of medicolegal autopsies. These cases included diabetic ketoacidosis, nondiabetic individuals presenting moderate to severe decompositional changes and nondiabetic medicolegal cases privy of decompositional changes. 3HB concentrations in liver sample homogenates correlate well with blood values in all examined groups. Additionally, decompositional changes were not associated with increases in blood and liver 3HB levels. These results suggest that 3HB can be reliably measured in liver homogenates when blood is not available at autopsy. Furthermore, they suggest that metabolic disturbances potentially leading or contributing to death may be objectified through liver 3HB determination even in decomposed bodies.