998 resultados para Post-extractive implant


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The bone mineral density increments in patients with sporadic primary hyperparathyroidism after parathyroidectomy have been studied by several investigators, but few have investigated this topic in primary hyperparathyroidism associated with multiple endocrine neoplasia type 1. Further, as far as we know, only two studies have consistently evaluated bone mineral density values after parathyroidectomy in cases of primary hyperparathyroidism associated with multiple endocrine neoplasia type 1. Here we revised the impact of parathyroidectomy (particularly total parathyroidectomy followed by autologous parathyroid implant into the forearm) on bone mineral density values in patients with primary hyperparathyroidism associated with multiple endocrine neoplasia type 1. Significant increases in bone mineral density in the lumbar spine and femoral neck values were found, although no short-term (15 months) improvement in bone mineral density at the proximal third of the distal radius was observed. Additionally, short-term and medium-term calcium and parathyroid hormone values after parathyroidectomy in patients with primary hyperparathyroidism associated with multiple endocrine neoplasia type 1 are discussed. In most cases, this surgical approach was able to restore normal calcium/parathyroid hormone levels and ultimately lead to discontinuation of calcium and calcitriol supplementation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: To compare the clinical outcomes of standard, cylindrical, screw-shaped to novel tapered, transmucosal (Straumann Dental implants immediately placed into extraction sockets. Material and methods: In this randomized-controlled clinical trial, outcomes were evaluated over a 3-year observation period. This report deals with the need for bone augmentation, healing events, implant stability and patient-centred outcomes up to 3 months only. Nine centres contributed a total of 208 immediate implant placements. All surgical and post-surgical procedures and the evaluation parameters were discussed with representatives of all centres during a calibration meeting. Following careful luxation of the designated tooth, allocation of the devices was randomly performed by a central study registrar. The allocated SLA titanium implant was installed at the bottom or in the palatal wall of the extraction socket until primary stability was reached. If the extraction socket was >or=1 mm larger than the implant, guided bone regeneration was performed simultaneously (Bio Oss and BioGide. The flaps were then sutured. During non-submerged transmucosal healing, everything was done to prevent infection. At surgery, the need for augmentation and the degree of wound closure was verified. Implant stability was assessed clinically and by means of resonance frequency analysis (RFA) at surgery and after 3 months. Wound healing was evaluated after 1, 2, 6 and 12 weeks post-operatively. RESULTS: The demographic data did not show any differences between the patients receiving either standard cylindrical or tapered implants. All implants yielded uneventful healing with 15% wound dehiscences after 1 week. After 2 weeks, 93%, after 6 weeks 96%, and after 12 weeks 100% of the flaps were closed. Ninety percent of both implant designs required bone augmentation. Immediately after implantation, RFA values were 55.8 and 56.7 and at 3 months 59.4 and 61.1 for cylindrical and tapered implants, respectively. Patient-centred outcomes did not differ between the two implant designs. However, a clear preference of the surgeon's perception for the appropriateness of the novel-tapered implant was evident. CONCLUSIONS: This RCT has demonstrated that tapered or standard cylindrical implants yielded clinically equivalent short-term outcomes after immediate implant placement into the extraction socket.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIM: To assess the clinical and radiographic outcomes of immediate transmucosal placement of implants into molar extraction sockets. STUDY DESIGN: Twelve-month multicenter prospective cohort study. MATERIAL AND METHODS: Following molar extraction, tapered implants with an endosseous diameter of 4.8 mm and a shoulder diameter of 6.5 mm were immediately placed into the sockets. Molars with evidence of acute periapical pathology were excluded. After implant placement and achievement of primary stability, flaps were repositioned and sutured allowing a non-submerged, transmucosal healing. Peri-implant marginal defects were treated according to the principles of guided bone regeneration (GBR) by means of deproteinized bovine bone mineral particles in conjunction with a bioresrobable collagen membrane. Standardized radiographs were obtained at baseline and 12 months thereafter. Changes in depth and width of the distance from the implant shoulder (IS) and from the alveolar crest (AC) to the bottom of the defect (BD) were assessed. RESULTS: Eighty-two patients (42 males and 40 females) were enrolled and followed for 12 months. They contributed with 82 tapered implants. Extraction sites displayed sufficient residual bone volume to allow primary stability of all implants. Sixty-four percent of the implants were placed in the areas of 36 and 46. GBR was used in conjunction with the placement of all implants. No post-surgical complications were observed. All implants healed uneventfully yielding a survival rate of 100% and healthy soft tissue conditions after 12 months. Radiographically, statistically significant changes (P<0.0001) in mesial and distal crestal bone levels were observed from baseline to the 12-month follow-up. CONCLUSIONS: The findings of this 12-month prospective cohort study showed that immediate transmucosal implant placement represented a predictable treatment option for the replacement of mandibular and maxillary molars lost due to reasons other than periodontitis including vertical root fractures, endodontic failures and caries.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Although considerable bone fill may occur following treatment of peri-implantitis, re-osseointegration appears to be limited and unpredictable. Objectives: To evaluate the effects of various decontamination techniques and implant surface configurations on re-osseointegration of contaminated dental implants. MATERIAL AND METHODS: Three months after tooth extraction, implants consisting of a basal part and an exchangeable intraosseous implant cylinder (EIIC) were placed in the mandibles of dogs. The EIIC was machined (M), sandblasted and acid-etched (SLA), or titanium plasma sprayed (TPS). Ligature-induced peri-implantitis was initiated 8 weeks post-implantation and lasted until bone loss reached the junction of the two implant parts. Three treatment modalities were applied: (T1) the EIIC was exchanged for a pristine EIIC; (T2) the EIIC was sprayed in situ with saline; and (T3) the EIIC was removed, cleansed outside the mouth by spraying with saline, steam-sterilized, and remounted. A collagen barrier was placed over each fixture, and 3 months later, samples were processed for histology and histomorphometry. RESULTS: T2 revealed the highest bone-to-implant contact (BIC) level (significantly better than T1 and T3). T2 also yielded the highest bone crest level (significantly better than T1), followed by T3 (significantly better than T1). SLA showed the highest BIC level (significantly better than M), followed by TPS. There were no statistically significant differences in bone crest height between implant types. CONCLUSIONS: Both SLA implants and in situ cleansing resulted in the best re-osseointegration and bone fill of previously contaminated implants.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A one-year-old healthy sheep received an implant stenting the mural ('posterior') leaflet of the mitral valve. The experiment was authorized by the Cantonal Ethical Committee. The surgery was performed on the open, beating heart during cardiopulmonary bypass (CPB). Management of anaesthesia was based on isoflurane with mechanical intermittent positive pressure ventilation (IPPV) of the lungs, combined with intercostal nerve blocks and intravenous fentanyl and lidocaine. Marked cardiovascular depression occurred towards the end of CPB time and required high doses of dopamine, dobutamine, lidocaine and ephedrine to allow for weaning off the CPB pump. Moreover, severe pulmonary dysfunction developed when IPPV was re-initiated after CPB. Hypoxaemia persisted throughout the recovery from general anaesthesia. Multiple organ failure developed gradually during the three postoperative days, leading to euthanasia of the animal. As described in this case, marked lung injury associated with some degree of failure of other vital organs may occur in sheep after CPB. Intraoperative cardiorespiratory complications when weaning-off may indicate the development of 'post-pump syndrome'.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Biodegradable magnesium plate/screw osteosynthesis systems were implanted on the frontal bone of adult miniature pigs. The chosen implant geometries were based on existing titanium systems used for the treatment of facial fractures. The aim of this study was to evaluate the in vivo degradation and tissue response of the magnesium alloy WE43 with and without a plasma electrolytic surface coating. Of 14 animals, 6 received magnesium implants with surface modification (coated), 6 without surface modification (uncoated), and 2 titanium implants. Radiological examination of the skull was performed at 1, 4, and 8 weeks post-implantation. After euthanasia at 12 and 24 weeks, X-ray, computed tomography, and microfocus computed tomography analyses and histological and histomorphological examinations of the bone/implant blocks were performed. The results showed a good tolerance of the plate/screw system without wound healing disturbance. In the radiological examination, gas pocket formation was found mainly around the uncoated plates 4 weeks after surgery. The micro-CT and histological analyses showed significantly lower corrosion rates and increased bone density and bone implant contact area around the coated screws compared to the uncoated screws at both endpoints. This study shows promising results for the further development of coated magnesium implants for the osteosynthesis of the facial skeleton.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

La reconstruction en deux étapes par expanseur et implant est la technique la plus répandue pour la reconstruction mammmaire post mastectomie. La formation d’une capsule périprothétique est une réponse physiologique universelle à tout corps étranger présent dans le corps humain; par contre, la formation d’une capsule pathologique mène souvent à des complications et par conséquent à des résultats esthétiques sous-optimaux. Le microscope électronique à balayage (MEB) est un outil puissant qui permet d’effectuer une évaluation sans pareille de la topographie ultrastructurelle de spécimens. Le premier objectif de cette thèse est de comparer le MEB conventionnel (Hi-Vac) à une technologie plus récente, soit le MEB environnemental (ESEM), afin de déterminer si cette dernière mène à une évaluation supérieure des tissus capsulaires du sein. Le deuxième objectif est d‘appliquer la modalité de MEB supérieure et d’étudier les modifications ultrastructurelles des capsules périprothétiques chez les femmes subissant différents protocoles d’expansion de tissus dans le contexte de reconstruction mammaire prothétique. Deux études prospectives ont été réalisées afin de répondre à nos objectifs de recherche. Dix patientes ont été incluses dans la première, et 48 dans la seconde. La modalité Hi-Vac s’est avérée supérieure pour l’analyse compréhensive de tissus capsulaires mammaires. En employant le mode Hi-Vac dans notre protocole de recherche établi, un relief 3-D plus prononcé à été observé autour des expanseurs BIOCELL® dans le groupe d’approche d’intervention retardée (6 semaines). Des changements significatifs n’ont pas été observés au niveau des capsules SILTEX® dans les groupes d’approche d’intervention précoce (2 semaines) ni retardée.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective To provide 2-year clinical- and patient-oriented data with regard to mandibular overdenture assisted by 2 immediately loaded unsplinted implants. Material and methods In this pre-post design, Phase-I clinical trial, 18 edentate individuals (62.4 ± 7.7 years) received a new set of complete denture. Then, following standard procedures, 3 threaded implants (OsseoSpeed TX™, Dentsply Implants, Mölndal, Sweden) were placed in the mandible in each patient, and locator abutments (Zest Anchors LLC, Escondido, U.S.A.) were inserted on the right and left side implants. The midline implant served as a control for within-patient comparison. The immediate loading was conducted within 24 h of surgery. Data were collected at baseline (T0), 12 (T1) and 24 (T2) months after immediate loading. The clinical outcomes included implant survival rate, crestal bone level changes and implant stability. These criteria were assessed through clinical and radiographic examinations as well as resonance frequency analysis. Patient-centered outcomes included patient satisfaction and oral health-related quality of life measured using validated questionnaires. Brunner-Langer approach was used for statistical analysis. Results Implant survival rate for immediate loaded implants was 91.7% at 2-year follow-up. None of the unloaded implants failed. There was no statistically significant difference at baseline and follow-ups with regard to clinical outcomes between loaded and unloaded implants. Patient satisfaction and quality of life improved (p < 0.0001) from baseline to 2-year follow-up. Conclusion Immediate loading protocol did not negatively affect clinical outcomes, satisfaction and quality of life of patients wearing 2-unsplinted-implant mandibular overdenture for 2 years. This conclusion requires confirmation by randomized control trials. Clinical significance statement Mandibular overdenture assisted by two immediately-loaded unsplinted implants is successful treatment based on 2-year clinical and patient-based outcomes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective To provide 2-year clinical- and patient-oriented data with regard to mandibular overdenture assisted by 2 immediately loaded unsplinted implants. Material and methods In this pre-post design, Phase-I clinical trial, 18 edentate individuals (62.4 ± 7.7 years) received a new set of complete denture. Then, following standard procedures, 3 threaded implants (OsseoSpeed TX™, Dentsply Implants, Mölndal, Sweden) were placed in the mandible in each patient, and locator abutments (Zest Anchors LLC, Escondido, U.S.A.) were inserted on the right and left side implants. The midline implant served as a control for within-patient comparison. The immediate loading was conducted within 24 h of surgery. Data were collected at baseline (T0), 12 (T1) and 24 (T2) months after immediate loading. The clinical outcomes included implant survival rate, crestal bone level changes and implant stability. These criteria were assessed through clinical and radiographic examinations as well as resonance frequency analysis. Patient-centered outcomes included patient satisfaction and oral health-related quality of life measured using validated questionnaires. Brunner-Langer approach was used for statistical analysis. Results Implant survival rate for immediate loaded implants was 91.7% at 2-year follow-up. None of the unloaded implants failed. There was no statistically significant difference at baseline and follow-ups with regard to clinical outcomes between loaded and unloaded implants. Patient satisfaction and quality of life improved (p < 0.0001) from baseline to 2-year follow-up. Conclusion Immediate loading protocol did not negatively affect clinical outcomes, satisfaction and quality of life of patients wearing 2-unsplinted-implant mandibular overdenture for 2 years. This conclusion requires confirmation by randomized control trials. Clinical significance statement Mandibular overdenture assisted by two immediately-loaded unsplinted implants is successful treatment based on 2-year clinical and patient-based outcomes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

L’isolement avec ou sans contention (IC) en milieu psychiatrique touche près d’un patient sur quatre au Québec (Dumais, Larue, Drapeau, Ménard, & Giguère-Allard, 2011). Il est pourtant largement documenté que cette pratique porte préjudice aux patients, aux infirmières et à l’organisation (Stewart, Van der Merwe, Bowers, Simpson, & Jones, 2010). Cette mesure posant un problème éthique fait l’objet de politiques visant à la restreindre, voire à l’éliminer. Les études sur l’expérience de l’isolement du patient de même que sur la perception des infirmières identifient le besoin d'un retour sur cet évènement. Plusieurs équipes de chercheurs proposent un retour post-isolement (REPI) intégrant à la fois l’équipe traitante, plus particulièrement les infirmières, et le patient comme intervention afin de diminuer l’incidence de l’IC. Le REPI vise l’échange émotionnel, l’analyse des étapes ayant mené à la prise de décision d’IC et la projection des interventions futures. Le but de cette étude était de développer, implanter et évaluer le REPI auprès des intervenants et des patients d’une unité de soins psychiatriques aigus afin d’améliorer leur expérience de soins. Les questions de recherche étaient : 1) Quel est le contexte d’implantation du REPI? 2) Quels sont les éléments facilitants et les obstacles à l’implantation du REPI selon les patients et les intervenants? 3) Quelle est la perception des patients et des intervenants des modalités et retombées du REPI?; et 4) L’implantation du REPI est-elle associée à une diminution de la prévalence et de la durée des épisodes d’IC? Cette étude de cas instrumentale (Stake, 1995, 2008) était ancrée dans une approche participative. Le cas était celui de l’unité de soins psychiatriques aigus pour premier épisode psychotique où a été implanté le REPI. En premier lieu, le développement du REPI a d’abord fait l’objet d’une documentation du contexte par une immersion dans le milieu (n=56 heures) et des entretiens individuels avec un échantillonnage de convenance (n=3 patients, n=14 intervenants). Un comité d’experts (l’étudiante-chercheuse, six infirmières du milieu et un patient partenaire) a par la suite développé le REPI qui comporte deux volets : avec le patient et en équipe. L’évaluation des retombées a été effectuée par des entretiens individuels (n= 3 patients, n= 12 intervenants) et l’examen de la prévalence et de la durée des IC six mois avant et après l’implantation du REPI. Les données qualitatives ont été examinées selon une analyse thématique (Miles, Huberman, & Saldana, 2014), tandis que les données quantitatives ont fait l’objet de tests descriptifs et non-paramétriques. Les résultats proposent que le contexte d’implantation est défini par des normes implicites et explicites où l’utilisation de l’IC peut générer un cercle vicieux de comportements agressifs nourris par un profond sentiment d’injustice de la part des patients. Ceux-ci ont l’impression qu’ils doivent se conformer aux attentes du personnel et aux règles de l’unité. Les participants ont exprimé le besoin de créer des opportunités pour une communication authentique qui pourrait avoir lieu lors du REPI, bien que sa pratique soit variable d’un intervenant à un autre. Les résultats suggèrent que le principal élément ayant facilité l’implantation du REPI est l’approche participative de l’étude, alors que les obstacles rencontrés relèvent surtout de la complexité de la mise en œuvre du REPI en équipe. Lors du REPI avec le patient, les infirmières ont pu explorer ses sentiments et son point de vue, ce qui a favorisé la reconstruction de la relation thérapeutique. Quant au REPI avec l’équipe de soins, il a été perçu comme une opportunité d’apprentissage, ce qui a permis d’ajuster le plan d’intervention des patients. Suite à l’implantation du REPI, les résultats ont d’ailleurs montré une réduction significative de l’utilisation de l’isolement et du temps passé en isolement. Les résultats de cette thèse soulignent la possibilité d’outrepasser le malaise initial perçu tant par le patient que par l’infirmière en systématisant le REPI. De plus, cette étude met l’accent sur le besoin d’une présence authentique pour atteindre un partage significatif dans la relation thérapeutique, ce qui est la pierre d’assise de la pratique infirmière en santé mentale. Cette étude contribue aux connaissances sur la prévention des comportements agressifs en milieu psychiatrique en documentant le contexte dans lequel se situe l’IC, en proposant un REPI comportant deux volets de REPI et en explorant ses retombées. Nos résultats soutiennent le potentiel du développement d’une prévention tertiaire qui intègre à la fois la perspective des patients et des intervenants.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

L’isolement avec ou sans contention (IC) en milieu psychiatrique touche près d’un patient sur quatre au Québec (Dumais, Larue, Drapeau, Ménard, & Giguère-Allard, 2011). Il est pourtant largement documenté que cette pratique porte préjudice aux patients, aux infirmières et à l’organisation (Stewart, Van der Merwe, Bowers, Simpson, & Jones, 2010). Cette mesure posant un problème éthique fait l’objet de politiques visant à la restreindre, voire à l’éliminer. Les études sur l’expérience de l’isolement du patient de même que sur la perception des infirmières identifient le besoin d'un retour sur cet évènement. Plusieurs équipes de chercheurs proposent un retour post-isolement (REPI) intégrant à la fois l’équipe traitante, plus particulièrement les infirmières, et le patient comme intervention afin de diminuer l’incidence de l’IC. Le REPI vise l’échange émotionnel, l’analyse des étapes ayant mené à la prise de décision d’IC et la projection des interventions futures. Le but de cette étude était de développer, implanter et évaluer le REPI auprès des intervenants et des patients d’une unité de soins psychiatriques aigus afin d’améliorer leur expérience de soins. Les questions de recherche étaient : 1) Quel est le contexte d’implantation du REPI? 2) Quels sont les éléments facilitants et les obstacles à l’implantation du REPI selon les patients et les intervenants? 3) Quelle est la perception des patients et des intervenants des modalités et retombées du REPI?; et 4) L’implantation du REPI est-elle associée à une diminution de la prévalence et de la durée des épisodes d’IC? Cette étude de cas instrumentale (Stake, 1995, 2008) était ancrée dans une approche participative. Le cas était celui de l’unité de soins psychiatriques aigus pour premier épisode psychotique où a été implanté le REPI. En premier lieu, le développement du REPI a d’abord fait l’objet d’une documentation du contexte par une immersion dans le milieu (n=56 heures) et des entretiens individuels avec un échantillonnage de convenance (n=3 patients, n=14 intervenants). Un comité d’experts (l’étudiante-chercheuse, six infirmières du milieu et un patient partenaire) a par la suite développé le REPI qui comporte deux volets : avec le patient et en équipe. L’évaluation des retombées a été effectuée par des entretiens individuels (n= 3 patients, n= 12 intervenants) et l’examen de la prévalence et de la durée des IC six mois avant et après l’implantation du REPI. Les données qualitatives ont été examinées selon une analyse thématique (Miles, Huberman, & Saldana, 2014), tandis que les données quantitatives ont fait l’objet de tests descriptifs et non-paramétriques. Les résultats proposent que le contexte d’implantation est défini par des normes implicites et explicites où l’utilisation de l’IC peut générer un cercle vicieux de comportements agressifs nourris par un profond sentiment d’injustice de la part des patients. Ceux-ci ont l’impression qu’ils doivent se conformer aux attentes du personnel et aux règles de l’unité. Les participants ont exprimé le besoin de créer des opportunités pour une communication authentique qui pourrait avoir lieu lors du REPI, bien que sa pratique soit variable d’un intervenant à un autre. Les résultats suggèrent que le principal élément ayant facilité l’implantation du REPI est l’approche participative de l’étude, alors que les obstacles rencontrés relèvent surtout de la complexité de la mise en œuvre du REPI en équipe. Lors du REPI avec le patient, les infirmières ont pu explorer ses sentiments et son point de vue, ce qui a favorisé la reconstruction de la relation thérapeutique. Quant au REPI avec l’équipe de soins, il a été perçu comme une opportunité d’apprentissage, ce qui a permis d’ajuster le plan d’intervention des patients. Suite à l’implantation du REPI, les résultats ont d’ailleurs montré une réduction significative de l’utilisation de l’isolement et du temps passé en isolement. Les résultats de cette thèse soulignent la possibilité d’outrepasser le malaise initial perçu tant par le patient que par l’infirmière en systématisant le REPI. De plus, cette étude met l’accent sur le besoin d’une présence authentique pour atteindre un partage significatif dans la relation thérapeutique, ce qui est la pierre d’assise de la pratique infirmière en santé mentale. Cette étude contribue aux connaissances sur la prévention des comportements agressifs en milieu psychiatrique en documentant le contexte dans lequel se situe l’IC, en proposant un REPI comportant deux volets de REPI et en explorant ses retombées. Nos résultats soutiennent le potentiel du développement d’une prévention tertiaire qui intègre à la fois la perspective des patients et des intervenants.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Un matériau semi-conducteur utilisé lors de la fabrication d’antennes térahertz (THz), le quaternaire InGaAsP (E_g = 0,79 eV), subit une implantation ionique de Fe suivi d’un recuit thermique rapide (RTA) dans le but d’améliorer ses propriétés d’émission. Le recuit est nécessaire afin de recristalliser la couche amorphisée lors de l’implantation, donnant lieu à un polycristal rempli de défauts de recristallisation. On constate cependant que les matériaux implantés Fe offrent de meilleures performances que ceux simplement endommagés au Ga. Dans le but de départager l’effet des défauts de recristallisation et des impuretés de Fe, des mesures de spectroscopie transitoire des niveaux profonds (DLTS) et de DLTS en courant (I-DLTS), ainsi que de spectrométrie de masse d’ions secondaires par temps de vol (ToF-SIMS) ont été effectuées sur des échantillons non implantés et d’autres recristallisés. Les mesures DLTS et I-DLTS ont pour but de caractériser les niveaux profonds générés par ces deux procédures postcroissance, tout en identifiant le rôle que jouent les impuretés de Fe sur la formation de ces niveaux profonds. De plus, le voisinage des atomes de Fe dans le matériau recristallisé a été étudié à l’aide des mesures ToF-SIMS. Les mesures DLTS sur matériau recristallisé sont peu concluantes, car la mesure de capacité est faussée par la haute résistivité du matériau. Par contre, les mesures I-DLTS sur matériau recristallisé ont permis de conclure que les impuretés de Fe sont responsables de la formation d’une grande variété de niveaux d’énergie se trouvant entre 0,25 et 0,40 eV, alors que les défauts de structure induisent des niveaux de moins de 0,25 eV. La concentration de Fe est élevée par rapport au seuil de solubilité du Fe dans le matériau recristallisé. Il serait donc plausible que des agrégats de Fe se forment. Toutefois, cette hypothèse est infirmée par l'absence de pic aux masses correspondant à la molécule ^(56)Fe_2^+ sur les spectres ToF-SIMS. De plus, un modèle simple est utilisé afin d’estimer si certaines masses présentes sur les spectres ToF-SIMS correspondent à des liaisons non induites par la mesure dans le matériau recristallisé. Bien qu’aucune liaison avec le Ga et l'As n’est détectable, ce modèle n’exclut pas la possibilité de liens préférentiels avec l’In.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Un matériau semi-conducteur utilisé lors de la fabrication d’antennes térahertz (THz), le quaternaire InGaAsP (E_g = 0,79 eV), subit une implantation ionique de Fe suivi d’un recuit thermique rapide (RTA) dans le but d’améliorer ses propriétés d’émission. Le recuit est nécessaire afin de recristalliser la couche amorphisée lors de l’implantation, donnant lieu à un polycristal rempli de défauts de recristallisation. On constate cependant que les matériaux implantés Fe offrent de meilleures performances que ceux simplement endommagés au Ga. Dans le but de départager l’effet des défauts de recristallisation et des impuretés de Fe, des mesures de spectroscopie transitoire des niveaux profonds (DLTS) et de DLTS en courant (I-DLTS), ainsi que de spectrométrie de masse d’ions secondaires par temps de vol (ToF-SIMS) ont été effectuées sur des échantillons non implantés et d’autres recristallisés. Les mesures DLTS et I-DLTS ont pour but de caractériser les niveaux profonds générés par ces deux procédures postcroissance, tout en identifiant le rôle que jouent les impuretés de Fe sur la formation de ces niveaux profonds. De plus, le voisinage des atomes de Fe dans le matériau recristallisé a été étudié à l’aide des mesures ToF-SIMS. Les mesures DLTS sur matériau recristallisé sont peu concluantes, car la mesure de capacité est faussée par la haute résistivité du matériau. Par contre, les mesures I-DLTS sur matériau recristallisé ont permis de conclure que les impuretés de Fe sont responsables de la formation d’une grande variété de niveaux d’énergie se trouvant entre 0,25 et 0,40 eV, alors que les défauts de structure induisent des niveaux de moins de 0,25 eV. La concentration de Fe est élevée par rapport au seuil de solubilité du Fe dans le matériau recristallisé. Il serait donc plausible que des agrégats de Fe se forment. Toutefois, cette hypothèse est infirmée par l'absence de pic aux masses correspondant à la molécule ^(56)Fe_2^+ sur les spectres ToF-SIMS. De plus, un modèle simple est utilisé afin d’estimer si certaines masses présentes sur les spectres ToF-SIMS correspondent à des liaisons non induites par la mesure dans le matériau recristallisé. Bien qu’aucune liaison avec le Ga et l'As n’est détectable, ce modèle n’exclut pas la possibilité de liens préférentiels avec l’In.