981 resultados para Portable.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Clinical microscopy is a versatile and robust tool used for the diagnosis of a plethora of diseases. However, due to various reasons, it remains inaccessible in resource limited settings. In this paper, we present an automated and cost-effective alternative to microscopy for use in clinical diagnostics. With the use of custom optics and microfluidics, we demonstrate a field-portable imaging flow cytometry system. Using the presented system, we have been able to image 586 cells per second. We demonstrate the clinical relevance of the proposed system by differentiating between suspensions of healthy and sphered RBCs based on high-throughput morphometric analysis. The instrument presented here is a major advancement in the domain of field portable diagnostics as it enables fast and robust quantitative diagnostic testing at the point-of-care.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Clinical microscopy is a versatile diagnostic platform used for diagnosis of a multitude of diseases. In the recent past, many microfluidics based point-of-care diagnostic devices have been developed, which serve as alternatives to microscopy. However, these point-of-care devices are not as multi-functional and versatile as clinical microscopy. With the use of custom designed optics and microfluidics, we have developed a versatile microscopy-based cellular diagnostic platform, which can be used at the point of care. The microscopy platform presented here is capable of detecting infections of very low parasitemia level (in a very small quantity of sample), without the use of any additional computational hardware. Such a cost-effective and portable diagnostic device, would greatly impact the quality of health care available to people living in rural locations of the world. Apart from clinical diagnostics, it's applicability to field research in environmental microbiology has also been outlined. (C) 2015 Author(s). All article content, except where otherwise noted, is licensed under a Creative Commons Attribution 3.0 Unported License.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The maintenance of adequate dissolved oxygen level is very important in the economy of any aquaculture system. An easy to construct aerating device was created using 0.5 hp water-pump, shower rose, Styrofoam, and rubber hose. The aerator works by drawing water from below and discharging it into the atmosphere as a spray. The spray is aerated as it splashes into the water surface. The aerating device has an average spray of 1.2 unit and doubles the dissolved oxygen content of 37.8 m super(3) tank in one hour

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This manual has been produced by members of the national acoustics group (NAG) and represents the first in a series of outputs designed to promote co-ordination and consistency in Agency hydroacoustic surveys. It is designed as a field guide for Agency staff operating the SIMRAD EY500 portable scientific echosounder. It should be simplistic enough for the newcomer to EY500 to be able to set up and run a mobile hydroacoustic survey with some knowledge of the supporting theory. It should act as guidance for standardisation of survey procedures providing a concise list of settings and recommendations that can be used as a quick reference guide in the field. This manual condenses 5 years of practical experience of surveying fish populations using Simrad hardware and software for surveying large rivers and still waters throughout England and Wales. This document should be used as a companion to the manufacturers instruction manual and not act as a substitute for it.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes the trials made with a simple portable canvas-tarpaulin tank system developed at the University Sains Malaysia for culture of hybrid catfish (Clarias gariepinus x Clarias macrocephalus) by Malaysia small scale farmers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A portable type warp load meter has been developed for the use in fishing trawlers. The instrument enables to monitor the warp load in fishing trawlers accurately and easily without disturbing the routine fishing operations. The instrument can be used in several other places like cranes, bollard tests for marine engines, dry docks etc. especially when the operation has to be conducted easily without disturbing the load system. The information displayed in micro ammeter in the range 0 to 1000 kg can be fed to continuous recorders for detailed analysis and permanent records.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A portable 3D laser scanning system has been designed and built for robot vision. By tilting the charge coupled device (CCD) plane of portable 3D scanning system according to the Scheimpflug condition, the depth-of-view is successfully extended from less than 40 to 100 mm. Based on the tilted camera model, the traditional two-step camera calibration method is modified by introducing the angle factor. Meanwhile, a novel segmental calibration approach, i.e., dividing the whole work range into two parts and calibrating, respectively, with corresponding system parameters, is proposed to effectively improve the measurement accuracy of the large depth-of-view 3D laser scanner. In the process of 3D reconstruction, different calibration parameters are used to transform the 2D coordinates into 3D coordinates according to the different positions of the image in the CCD plane, and the measurement accuracy of 60 mu m is obtained experimentally. Finally, the experiment of scanning a lamina by the large depth-of-view portable 3D laser scanner used by an industrial robot IRB 4400 is also employed to demonstrate the effectiveness and high measurement accuracy of our scanning system. (C) 2007 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Predictability -- the ability to foretell that an implementation will not violate a set of specified reliability and timeliness requirements -- is a crucial, highly desirable property of responsive embedded systems. This paper overviews a development methodology for responsive systems, which enhances predictability by eliminating potential hazards resulting from physically-unsound specifications. The backbone of our methodology is the Time-constrained Reactive Automaton (TRA) formalism, which adopts a fundamental notion of space and time that restricts expressiveness in a way that allows the specification of only reactive, spontaneous, and causal computation. Using the TRA model, unrealistic systems – possessing properties such as clairvoyance, caprice, infinite capacity, or perfect timing -- cannot even be specified. We argue that this "ounce of prevention" at the specification level is likely to spare a lot of time and energy in the development cycle of responsive systems -- not to mention the elimination of potential hazards that would have gone, otherwise, unnoticed. The TRA model is presented to system developers through the Cleopatra programming language. Cleopatra features a C-like imperative syntax for the description of computation, which makes it easier to incorporate in applications already using C. It is event-driven, and thus appropriate for embedded process control applications. It is object-oriented and compositional, thus advocating modularity and reusability. Cleopatra is semantically sound; its objects can be transformed, mechanically and unambiguously, into formal TRA automata for verification purposes, which can be pursued using model-checking or theorem proving techniques. Since 1989, an ancestor of Cleopatra has been in use as a specification and simulation language for embedded time-critical robotic processes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The problem was to determine whether a method of aural and visual vocal training that included a program of portable electronic piano keyboard experience would be more effective in teaching sight-singing skills to novice high school chorus students than a method that included only aural and visual vocal training. A sub-problem was to determine whether novice chorus students enjoyed playing electronic keyboards in chorus as a reinforcement experience in sight-singing training. Students were randomly assigned to two treatment groups, tested with the Musical Aptitude Profile, Tonal Imagery, part A, and then trained separately. The experimental group sang repetitions of melodic patterns and utilized techniques associated with the Kodály Method while simultaneously playing keyboard. The comparison group received a similar treatment without using keyboards. The students were pre- and post-tested in sight-singing using the Vocal Sight-Reading Inventory. Results of the Analysis of Covariance using MAP scores as the covariate revealed no significant difference (p<.05) between post-test scores of the two groups. Improvement was noted in 96% of students from pre-test to post-test regardless of grouping. The repeated measures ANOVA revealed a significant relationship (p<.006) between aptitude group and post-test score. High aptitude students in both groups were found to benefit more from the training than low aptitude students. High aptitude keyboard group students achieved an average gain score that was 8.67 points higher than the comparison group. Of the total experimental group, 92% enjoyed playing keyboards in chorus. It is recommended that future research be undertaken to study the use of keyboards with advanced high school choruses and with uncertain singers in the high school chorus. Research is also needed to develop graded, valid, and reliable sight-singing tests for use in high school chorus. Techniques of the Kodály Method should be further investigated for use in high school sight-singing training.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ability of diffuse reflectance spectroscopy to extract quantitative biological composition of tissues has been used to discern tissue types in both pre-clinical and clinical cancer studies. Typically, diffuse reflectance spectroscopy systems are designed for single-point measurements. Clinically, an imaging system would provide valuable spatial information on tissue composition. While it is feasible to build a multiplexed fiber-optic probe based spectral imaging system, these systems suffer from drawbacks with respect to cost and size. To address these we developed a compact and low cost system using a broadband light source with an 8-slot filter wheel for illumination and silicon photodiodes for detection. The spectral imaging system was tested on a set of tissue mimicking liquid phantoms which yielded an optical property extraction accuracy of 6.40 +/- 7.78% for the absorption coefficient (micro(a)) and 11.37 +/- 19.62% for the wavelength-averaged reduced scattering coefficient (micro(s)').

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Steady-state diffuse reflection spectroscopy is a well-studied optical technique that can provide a noninvasive and quantitative method for characterizing the absorption and scattering properties of biological tissues. Here, we compare three fiber-based diffuse reflection spectroscopy systems that were assembled to create a light-weight, portable, and robust optical spectrometer that could be easily translated for repeated and reliable use in mobile settings. The three systems were built using a broadband light source and a compact, commercially available spectrograph. We tested two different light sources and two spectrographs (manufactured by two different vendors). The assembled systems were characterized by their signal-to-noise ratios, the source-intensity drifts, and detector linearity. We quantified the performance of these instruments in extracting optical properties from diffuse reflectance spectra in tissue-mimicking liquid phantoms with well-controlled optical absorption and scattering coefficients. We show that all assembled systems were able to extract the optical absorption and scattering properties with errors less than 10%, while providing greater than ten-fold decrease in footprint and cost (relative to a previously well-characterized and widely used commercial system). Finally, we demonstrate the use of these small systems to measure optical biomarkers in vivo in a small-animal model cancer therapy study. We show that optical measurements from the simple portable system provide estimates of tumor oxygen saturation similar to those detected using the commercial system in murine tumor models of head and neck cancer.