122 resultados para Polytetrafluoroethylene
Resumo:
The ESR spectra of poly(chlorotrifluoroethylene) were recorded following gamma-radiolysis under vacuum at room temperature and 77 K. The very broad spectrum at 77 K revealed little fine structure with which to identity the radicals formed upon irradiation, but subsequent photobleaching and annealing studies, together with radiolytic studies at higher temperatures, afforded scope for making radical assignments. Both main-chain radicals and a range of chain-end radicals have been identified. The G-values for radical formation were 1.55, 0.36 and 0.32 at 77 K, 273 K and room temperature, respectively. (C) 2003 Elsevier Science Ltd. All rights reserved.
Resumo:
Fluoropolymers are known as chemically inert materials with good high temperature resistance, so they are often the materials of choice for harsh chemical environments. These properties arise because the carbon-fluorine bond is the strongest of all bonds between other elements and carbon, and, because of their large size, fluorine atoms can protect the carbon backbone of polymers such as poly(tetrafluoroethylene), PTFE, from chemical attack. However, while the carbon-fluorine bond is much stronger than the carbon hydrogen bond, the G values for radical formation on high energy radiolysis of fluoropolymers are roughly comparable to those of their protonated counterparts. Thus, efficient high energy radiation grafting of fluoropolymers is practical, and this process can be used to modify either the surface or bulk properties of a fluoropolymer. Indeed, radiation grafted fluoropolymers are currently being used as separation membranes for fuel cells, hydrophilic filtration membranes and matrix substrate materials for use in combinatorial chemistry. Herein we present a review of recent studies of the high energy radiation grafting of fluoropolymers and of the analytical methods available to characterize the grafts. (C) 2003 Elsevier Ltd. All rights reserved.
Resumo:
For some applications for fluoropolymers they must be subjected to high-energy radiation, e.g., when they are grafted with styrene using an irradiation method to produce fuel cell membranes or matrix supports for combinatorial chemistry. In some of these applications they may be subjected to mechanical stress or elevated temperature, so it is important to elucidate the effects of the radiolysis on these properties. In the present work the effect of gamma-radiolysis on the glass transition, melting behavior, and thermal stability of PFA has been studied as well as the effect of the radiolysis on the tensile properties of the polymer.
Resumo:
The effect of electron beam radiation on a perfluoroalkoxy (PFA) resin was examined using solid-state high-speed magic angle spinning F-19 NMR spectroscopy and FT-IR spectroscopy. Samples were prepared for analysis by subjecting them to electron beam radiation in the dose range 0.5-2.0 MGy at 633 K, which is above the crystalline melting temperature. The new structures were identified and include new saturated chain ends, short and long branches, unsaturated groups, and cross-links. The radiation chemical yield (G value) of new long branch points was greater than the G value of new chain ends, suggesting that cross-linking is the net radiolytic process. This conclusion was supported by an observed decrease in the crystallinity and an increase in the optical clarity of the polymer.
Resumo:
This study aimed to characterize air pollution and the associated carcinogenic risks of polycyclic aromatic hydrocarbon (PAHs) at an urban site, to identify possible emission sources of PAHs using several statistical methodologies, and to analyze the influence of other air pollutants and meteorological variables on PAH concentrations.The air quality and meteorological data were collected in Oporto, the second largest city of Portugal. Eighteen PAHs (the 16 PAHs considered by United States Environment Protection Agency (USEPA) as priority pollutants, dibenzo[a,l]pyrene, and benzo[j]fluoranthene) were collected daily for 24 h in air (gas phase and in particles) during 40 consecutive days in November and December 2008 by constant low-flow samplers and using polytetrafluoroethylene (PTFE) membrane filters for particulate (PM10 and PM2.5 bound) PAHs and pre-cleaned polyurethane foam plugs for gaseous compounds. The other monitored air pollutants were SO2, PM10, NO2, CO, and O3; the meteorological variables were temperature, relative humidity, wind speed, total precipitation, and solar radiation. Benzo[a]pyrene reached a mean concentration of 2.02 ngm3, surpassing the EU annual limit value. The target carcinogenic risks were equal than the health-based guideline level set by USEPA (106) at the studied site, with the cancer risks of eight PAHs reaching senior levels of 9.98107 in PM10 and 1.06106 in air. The applied statistical methods, correlation matrix, cluster analysis, and principal component analysis, were in agreement in the grouping of the PAHs. The groups were formed according to their chemical structure (number of rings), phase distribution, and emission sources. PAH diagnostic ratios were also calculated to evaluate the main emission sources. Diesel vehicular emissions were the major source of PAHs at the studied site. Besides that source, emissions from residential heating and oil refinery were identified to contribute to PAH levels at the respective area. Additionally, principal component regression indicated that SO2, NO2, PM10, CO, and solar radiation had positive correlation with PAHs concentrations, while O3, temperature, relative humidity, and wind speed were negatively correlated.
Resumo:
As ligaes adesivas tm sido cada vez mais utilizadas nos ltimos anos em detrimento de outros mtodos tais como a soldadura, ligaes aparafusadas e ligaes rebitadas. Os plsticos de Engenharia tm um papel cada vez mais preponderante na indstria, devido s suas excelentes propriedades. Neste trabalho foram considerados trs polmeros diferentes, o Policloreto de Vinilo (PVC) e o Polipropileno (PP) dado o seu baixo custo e peso e a superfcie quimicamente inerte e o Politetrafluoretileno (PTFE) devido s suas boas propriedades qumicas e excelentes propriedades de deslizamento. No entanto, estes materiais possuem uma baixa energia de superfcie e, por isso, so muito difceis de colar com mais relevncia para o PTFE. Assim, aps um estudo preliminar foi escolhido, para realizar as colagens necessrias, um adesivo da Tamarron Technology Tam Tech Adhesive, prprio para este tipo de substratos difceis de colar. Posteriormente foi efetuada a sua caraterizao atravs de ensaios de provetes macios trao. O principal objetivo deste trabalho foi estudar juntas de sobreposio simples de materiais polimricos difceis de colar tais como o PTFE, PP e PVC com recurso a um adesivo que no necessitasse de preparao de superfcie. Foram fabricadas juntas de sobreposio simples (JSS) segundo os mtodos Lap Shear (LS) e Block Shear (BS) dos trs materiais referidos anteriormente e realizados os respetivos ensaios para avaliar o comportamento mecnico das ligaes adesivas. Os materiais utilizados como substratos foram tambm submetidos a ensaios de trao com a finalidade de obter o mdulo de elasticidade e as suas propriedades de resistncia. Os substratos envolvidos nas juntas adesivas no sofreram qualquer preparao especial das superfcies. Na maioria dos casos consistiu apenas numa limpeza das superfcies com lcool etlico. Contudo, para o PTFE tambm se experimentou a preparao por abraso com lixa e por chama. Foi tambm efetuado um trabalho de simulao numrica por elementos finitos utilizando um modelo de dano coesivo triangular. As resistncias ao corte obtidas so superiores em BS comparativamente a LS, exceo feita aos substratos de PTFE aonde os resultados so similares. O tratamento por chama melhorou a resistncia mecnica das juntas. Verificou-se tambm que o modelo numrico simulou adequadamente o comportamento das juntas principalmente das LS.
Resumo:
OBJECTIVE: Venous aneurysms of the lower limbs are rare. When they involve the deep venous system, they can be associated with deep venous thrombosis and pulmonary embolism. The authors report the case of a 63-year-old women evaluated by duplex imaging and venography, in the context of a pulmonary embolism, and detected bilateral large aneurysms of the femoral veins (5 cm in the right femoral vein and 4 cm in the left femoral vein). The aneurysms were located at the bifurcation of the common femoral vein with the superficial and profound veins. METHOD: The right aneurysm was partially thrombosed. The patient was asymptomatic in the lower-limb extremities. After a period of anticoagulation, the authors proceeded to surgically excise the right aneurysm and replaced the venous system using a polytetrafluoroethylene (PTFE) graft with the construction of an a-v fistula. RESULT: The patient had no complications in the postoperative period and her 8-month follow-up examination revealed no symptoms, not even leg edema. The duplex scan showed patency of the graft. She continued with oral anticoagulation. The histologic examination revealed an eosinophilic inflammatory reaction of the vein wall, compatible with the diagnosis of Churg-Strauss syndrome. CONCLUSION: The authors conclude that they have probably described the first case in the international literature of a venous aneurysm with a Churg-Strauss syndrome and pulmonary embolism.
Resumo:
Dissertao de mestrado Internacional em Sustentabilidade do Ambiente Construdo
Resumo:
Primary rib involvement accounts for 16% of paediatric Ewing sarcoma (ES). Neo-adjuvant chemotherapy and surgical tumor resection may leave large thoracic wall defects requiring complex reconstruction in a growing individual. We report our experience in three children aged 3, 10, and 12 years, in whom single-stage resection and reconstruction were performed using a Gore-Tex Dualmesh patch, covered by a latissimus dorsi rotation flap harvested in continuity with the thoracolumbar fascia. The youngest patient also had a vertical expandable prosthetic titanium rib (VEPTR) anchored to help prevent subsequent scoliosis throughout growth.
Resumo:
The quantification of ammonia (NH3) losses from sugarcane straw fertilized with urea can be performed with collectors that recover the NH3 in acid-treated absorbers. Thus, the use of an open NH3 collector with a polytetrafluoroethylene (PTFE)-wrapped absorber is an interesting option since its cost is low, handling easy and microclimatic conditions irrelevant. The aim of this study was to evaluate the efficiency of an open collector for quantifying NH3-N volatilized from urea applied over the sugarcane straw. The experiment was carried out in a sugarcane field located near Piracicaba, So Paulo, Brazil. The NH3-N losses were estimated using a semi-open static collector calibrated with 15N (reference method) and an open collector with an absorber wrapped in PTFE film. Urea was applied to the soil surface in treatments corresponding to rates of 50, 100, 150 and 200 kg ha-1 N. Applying urea-N fertilizer on sugarcane straw resulted in losses NH3-N up to 24 % of the applied rate. The amount of volatile NH3-N measured in the open and the semi-open static collector did not differ. The effectiveness of the collection system varied non-linearly, with an average value of 58.4 % for the range of 100 to 200 kg ha-1 of urea-N. The open collector showed significant potential for use; however, further research is needed to verify the suitability of the proposed method.
Resumo:
Background Patients with cirrhosis in ChildPugh class C or those in class B who have persistent bleeding at endoscopy are at high risk for treatment failure and a poor prognosis, even if they have undergone rescue treatment with a transjugular intrahepatic porto - systemic shunt (TIPS). This study evaluated the earlier use of TIPS in such patients. Methods We randomly assigned, within 24 hours after admission, a total of 63 patients with cirrhosis and acute variceal bleeding who had been treated with vasoactive drugs plus endoscopic therapy to treatment with a polytetrafluoroethylene-covered stent within 72 hours after randomization (early-TIPS group, 32 patients) or continuation of vasoactive-drug therapy, followed after 3 to 5 days by treatment with propranolol or nadolol and long-term endoscopic band ligation (EBL), with insertion of a TIPS if needed as rescue therapy (pharmacotherapyEBL group, 31 patients). Results During a median follow-up of 16 months, rebleeding or failure to control bleeding occurred in 14 patients in the pharmacotherapyEBL group as compared with 1 patient in the early-TIPS group (P=0.001). The 1-year actuarial probability of remaining free of this composite end point was 50% in the pharmacotherapyEBL group versus 97% in the early-TIPS group (P<0.001). Sixteen patients died (12 in the pharmacotherapyEBL group and 4 in the early-TIPS group, P=0.01). The 1-year actuarial survival was 61% in the pharmacotherapyEBL group versus 86% in the early-TIPS group (P<0.001). Seven patients in the pharmacotherapyEBL group received TIPS as rescue therapy, but four died. The number of days in the intensive care unit and the percentage of time in the hospital during follow-up were significantly higher in the pharmacotherapyEBL group than in the early-TIPS group. No significant diferences were observed between the two treatment groups with respect to serious adverse events. Conclusions In these patients with cirrhosis who were hospitalized for acute variceal bleeding and at high risk for treatment failure, the early use of TIPS was associated with signif icant reductions in treatment failure and in mortality. (Current Controlled Trials number, ISRCTN58150114.)
Resumo:
Introduction: Chronic insufficiency alters homeostasis, in part due to endothelial inflammation. Plasminogen activator inhibitor-1 (PAI-1) is increased in renal disease, contributing to vascular damage. We assessed PAI-1 activity and PAI-1 4G/5G polymorphism in hemodialysis (HD) subjects and any association between thrombotic vascular access (VA) events and PAI-1 polymorphism. Methods: Prospective, observational study in 36 HD patients: mean age: 66.6 +/- 12.5 yr, males n=26 (72%), time on HD: 28.71 +/- 22.45 months. Vascular accesses: 10 polytetrafluoroethylene grafts (PTFEG), 22 arteriovenous fistulae (AVF), four dual lumen catheters (CAT). Control group (CG): 40 subjects; mean age: 60.0 +/- 15 yrs, males n=30 (75%). Group A (GA): thrombotic events (n=12), and group B (GB): No events (n=24). Groups were no different according to age (69.2 +/- 9.12 vs. 65.3 +/- 14.5 yrs), gender (males: 7; 58.3% vs. 18; 81.8%), time on HD (26.1 +/- 14.7 vs. 30.1 +/- 38.7 months), causes of renal failure. Time to follow-up, for access thrombosis: 12 months. Results: PAI-1 levels in HD: 7.21 +/- 2.13 vs. CG: 0.42 +/- 0.27 U/ml (p < 0.000 1). PAI-1 4G/5G polymorphic variant distribution in HD: 5G/5G: 6 (17%),4G/5G: 23 (64%); 4G/4G: 7 (19%) and in CG: 5G/5G: 14 (35%); 4G/5G: 18 (45%); 4G/4G: 8 (20%). C-reactive protein (CRP) in HD: 24.5 +/- 15.2 mg/L vs. in CG 2.3 +/- 0.2 mg/L (p < 0.0001). PAI-1 4G/5G variants: GA: 5G/5G: 3; 4G/5G: 8; 4G/4G: 1; GB: 5G/5G: 3; 4G/5G: 15; 4G/4G: 6. Thrombosis occurred in 8/10 patients (80%) with PTFEG, 3/22 (9%) in AVF, and 1/4 (25%) in CAT. Among the eight PTFEG patients with thrombosis, seven were PAI 4G/5G. Conclusions: PAI-1 levels were elevated in HD patients, independent of their polymorphic variants, 4G/5G being the most prevalent variant. Our data suggest that in patients with PTFEG the 4G/5G variant might be associated with an increased thrombosis risk.
Resumo:
For several years the Iowa Department of Transportation (DOT), Iowa State University, the Federal Highway Administration, and several Iowa counties have been working to develop accelerated bridge construction (ABC) concepts, details, and processes. Throughout this development, much has been learned and has resulted in Iowa being viewed as a national leader in the area of ABC. However, at this time, the Office of Bridges and Structures does not have a complete set of working standards nor design examples to accompany ABC portions of the bridge design manual (now called the Load and Resistance Factor Design/LRFD Bridge Design Manual). During the fall of 2013, the Iowa DOT constructed a bridge on IA 92 in Cass County using an ABC technique known as slide-in bridge construction. During the design of the Cass County Bridge, several questions were raised about the performance of critical design and construction details: the pile-to-pile cap connection and the polytetrafluoroethylene (PTFE) coated bearing pads on which the bridge would slide. The timing of this specific need and the initiation of this project offered a unique opportunity to provide significant short- and long-term value to the Office of Bridges and Structures. Several full-scale laboratory tests, which included several variations of the pile-to-pile cap connection and bearing pad slides, were completed. These tests proved that the connection was capable of achieving the desired capacity and that the expected coefficient of friction of the bearing pads was reasonably low. Finally, a design tool was developed for the Office of Bridges and Structures to be used on future projects that might benefit from a precast pile cap.