1000 resultados para Poluição do ar, redução, Brasil
Resumo:
The intensive development in the urbanization process implied a series of economic, social, and gradually, environmental transformations, essentially, since its intensification, which took place from the Industrial Revolution in Europe and North America. In Latin American countries, including Brazil, there was such acceleration in urban sprawl, only in the middle of the twentieth century, fomented by a peculiar industrialization, coming from the scientific-technical revolution, which occurred in developing countries. In this context, and with a lack of planning and an effective organization, cities of the dependent countries face an inordinate population growth and an unprecedented industrial swelling. Brazil, following this trend, presents several issues regarding the gaps in the provision of necessary infrastructure to meet the most basic needs of its population and the intense activity and anthropogenic effects on the environment. In this sense, environmental problems, related to air and water pollution, degradation and contamination of soil, paving roads, reduction of green areas, urban heat island, among others, reaching ever deeper into the Brazilian urban areas. It is important the analysis in this final project, the weather events related to episodes of strong winds and the events and the impacts to the population of Rio Claro (SP) in the period 2005 to 2010, basing themselves in Geographical Climatology and Urban climate studies. In this scenario, we found the prevalence of occurrences linked to falling trees in the study area, connected, at the same time, to the occurrence and to the absence of episodes of extreme events, with measurements of strong winds, showing a connection between the events and external facts to episodes of winds
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
O estudo teve por objetivo construir um modelo de regressão baseada no uso do solo para predizer a concentração material particulado inalável (MP10) no município de São Paulo, Brasil. O estudo se baseou na média de MP10 de 2007 de 9 estações de monitoramento. Obtiveram-se dados demográficos, viários e de uso do solo em círculos concêntricos de 250 a 1.000 m para compor o modelo. Calculou-se regressão linear simples para selecionar as variáveis mais robustas e sem colinearidade. Quatro variáveis entraram no modelo de regressão múltipla. Somente tráfego leve em círculos concêntricos <250 m permaneceu no modelo final, que explicou 63,8% da variância de MP10. Verificou-se que o método de regressão baseada no uso do solo é rápido, de fácil execução. Entretanto, este modelo se baseou em medições de MP10 de poucos locais.
Resumo:
Introdução A poluição do ar é um fator de risco associado com descompensação e mortalidade em pacientes com insuficiência cardíaca (IC). Objetivo Avaliar o impacto de um filtro de polipropileno sobre desfechos cardiovasculares em pacientes com IC e voluntários saudáveis durante exposição controlada à poluição. Métodos Ensaio clínico duplocego, controlado e cruzado, incluindo 26 pacientes com IC e 15 voluntários saudáveis, expostos a três protocolos diferentes de inalação randomizados por ordem: Ar Limpo; Exposição à Partículas de Exaustão do Diesel (ED); e ED filtrada. Os desfechos estudados foram função endotelial por índice de hiperemia reativa (RHi) e índice de aumento (Aix), biomarcadores séricos, variáveis de teste cardiopulmonar submáximo (caminhada de seis-minutos [tc6m]; consumo de oxigênio [VO2]; equivalente ventilatório de gás carbônico [VE/VCO2 slope]; consumo de O2 por batida [PulsoO2]) e variabilidade da frequência cardíaca (VFC). Resultados No grupo IC, a ED piorou o RHi [de 2,17 (IQR: 1,8-2,5) para 1,72 (IQR: 1,5-2,2); p=0,002], reduziu o VO2 [de 11.0 ± 3.9 para 8.4±2.8ml/Kg/min; p < 0.001], o tc6m [de 243,3±13 para 220,8 ± 14m; p=0,030] e o PulsoO2 [de 8.9 ± 1.0 para 7.8±0.7ml/bpm; p < 0.001]; e aumentou o BNP [de 47,0pg/ml (IQR: 17,3-118,0) para 66,5pg/ml (IQR: 26,5-155,5); p=0,004]. O filtro foi capaz de reduzir a concentração de poluição de 325±31 para 25±6?g/m3 (p < 0,001 vs. ED). No grupo IC, o filtro foi associado com melhora no RHi [2,06 (IQR: 1,5-2,6); p=0,019 vs. ED); aumento no VO2 (10.4 ± 3.8ml/Kg/min; p < 0.001 vs. ED) e PulsoO2 (9.7±1.1ml/bpm; p < 0.001 vs. ED); e redução no BNP [44,0pg/ml (IQR: 20,0-110,0); p=0,015 vs. ED]. Em ambos os grupos, a ED reduziu o Aix, sem efeito do filtro. O uso do filtro foi associado com maior ventilação e reinalação de CO2. Outras variáveis pesquisadas como VE/VCO2 slope e VFC não sofreram influências entre os protocolos. Conclusão A poluição do ar afetou adversamente o desempenho cardiovascular de pacientes com IC. Este é o primeiro ensaio clínico demonstrando que um simples filtrorespiratório pode prevenir a disfunção endotelial, a intolerância ao exercício e o aumento do BNP associados à poluição em pacientes com IC. O uso de máscaras com filtro tem o potencial de reduzir a morbidade associada à IC. Identificador ClinicalTrials.gov: NCT01960920
Resumo:
The Amazon holds over half of the planet's remaining tropical forests and comprises the largest biodiversity in the world, accounting for approximately 60 % of the Brazilian territory. However, deforestation fires in the region causes serious problems to exposed human. The aim of this study was to evaluate the chemical compounds as well as the cellular and molecular effects after exposure to organic material extracted from particulate matter less than 10 µm (PM10) in the Amazon region. As for the chemical composition, n-alkanes analysis showed a prevalence of anthropogenic influence during the fires in the region. In addition, there was a predominance of monosaccharides from biomass burning markers. Also, the Polycyclic Aromatic Hydrocarbons (PAH) and their derivatives have also been identified in samples collected in the Amazon. By using the PAH concentrations was possible to calculate the BaP-equivalent and it was found that the dibenz(a) anthracene contributes with 83% to potential carcinogenic risk. As for the potential mutagenic risk, the benzo (a) pyrene is the HPA that has a major contribution in this analysis. It may be noted that the retene was the most abundant PAH. This compound was genotoxic and cause death by necrosis in the human lung cells. In biological tests, the data showed that organic PM10 is capable of causing genetic damage in both plant cells and in human lung cells. This damage cause an arrest in the G1 phase of the cell cycle exposed, increasing the expression of p53 and p21. Additionally, the PM10 caused cell death by apoptosis, increasing the foci of histone - H2AX. Given these results, it is important to emphasize the reduction and better control of biomass burning in the Amazon region thus improving the quality of health of the population being exposed. As clearly stated recently by the World Health Organization, the reduction of air pollution could save millions of lives annually.
Resumo:
The main aim of this study was to evaluate the impact of the urban pollution plume from the city of Manaus by emissions from mobile and stationary sources in the atmospheric pollutants concentrations of the Amazon region, by using The Weather Research and Forecasting with Chemistry (WRF-Chem) model. The air pollutants analyzed were CO, NOx, SO2, O3, PM2.5, PM10 and VOCs. The model simulations have been configured with a grid spacing of 3 km, with 190 x and 136 y grid points in horizontal spacing, centered in the city of Manaus during the period of 17 and 18 of March 2014. The anthropogenic emissions inventories have gathered from mobile sources that were estimated the emissions of light and heavy-duty vehicles classes. In addition, the stationary sources have considered the thermal power plants by the type of energy sources used in the region as well as the emissions from the refinery located in Manaus. Various scenarios have been defined with numerical experiments that considered only emissions by biogenic, mobile and stationary sources, and replacement fuel from thermal power plant, along with a future scenario consisting with twice as much anthropogenic emissions. A qualitative assessment of simulation with base scenario has also been carried out, which represents the conditions of the region in its current state, where several statistical methods were used in order to compare the results of air pollutants and meteorological fields with observed ground-based data located in various points in the study grid. The qualitative analysis showed that the model represents satisfactorily the variables analyzed from the point of view of the adopted parameters. Regarding the simulations, defined from the base scenarios, the numerical experiments indicate relevant results such as: it was found that the stationary sources scenario, where the thermal power plants are predominant, resulted in the highest concentrations, for all air pollutants evaluated, except for carbon monoxide when compared to the vehicle emissions scenario; The replacement of the energy matrix of current thermal power plants for natural gas have showed significant reductions in pollutants analyzed, for instance, 63% reductions of NOx in the contribution of average concentration in the study grid; A significant increase in the concentrations of chemical species was observed in a futuristic scenario, reaching up to a 81% increase in peak concentrations of SO2 in the study area. The spatial distributions of the scenarios have showed that the air pollution plume from Manaus is predominantly west and southwest, where it can reach hundreds of kilometers to areas dominated by original soil covering.
Resumo:
Air pollution can threat the environment and public health, and is assess by pollutant ́s concentration measurements in order to verify whether the limits set by environmental agencies are being respected. However, these measures do not indicate immediately the impacts to living beings. To faced this problem, plants are been investigated as potential bioindicators of air pollution and, among them, stand out bromeliads Tillandsia genus which colonize various substrates,. obtaining water and nutrients from the atmosphere directly. In this context, this research assessed the potential of epiphytic bromeliad Tillandsia recurvata (L.) L. found in urbanized areas of the city of Curitiba - PR as a bioindicator of urban air pollution. According to vehicle traffic, five sample points were selected and classified. Points P1 and P2 were classified as high-traffic vehicle due presenting trucks and urban transport; point P3 was classified as moderate traffic due the predominance of private vehicles and urban transport; and points P4 and P5 were classified as low-traffic, presenting circulation of private vehicles only. There were analyzed the abundance of T. recurvata, morphophysiological parameters (leaf area, leaf specific area, sclerophylly index, percentage dry weight / fresh weight, chlorophyll (a + b), analysis of structural mesophyll organization) and the heavy metals accumulation (Fe, Cd, Cr, Cu, Pb and Zn). The abundance analysis and the results obtained for metals analysis were correlated with the intensity of vehicular traffic, directing the sampling points P1 > P2 = P3 > P4 = P5. This result demonstrate that the abundance of T. recurvata is greater in urban air pollution impacted areas, thus indicating that T. recurvata absorbs and accumulates metals and can be used in biomonitoring of urban air pollution in areas impacted by vehicular traffic. Morphophysiological parameters analyzed shows that the internal plant ́s structure is not significantly impacted by urban air pollution due plant ́s adptations. The presence of absorbing scales, the CAM metabolism pathway and it ́s store water ability, among other features, demonstrate their potential as bio-indicator in urban areas, especially regarding heavy metals accumulation .
Resumo:
A rápida urbanização e acelerada modernização da maioria das cidades dos países ditos de terceiro mundo, desencadeiam problemas que hoje são causadores de grandes conflitos, esses problemas por sua vez são decorrentes de falhas no planejamento urbano e ambiental, que por sua vez são resultantes do uso indevido dos recursos naturais e deficiente distribuição das riquezas dos municípios. A qualidade de vida está diretamente relacionada com problemas como enchentes, alagamentos, precariedade no sistema de saúde, educação e transporte; ocupação desordenada, construções habitacionais irregulares, poluição dos córregos, deficiência de saneamento básico, ausência de locais públicos de lazer, poluição do ar, sonora e visual; qualidade da água potável entre outros. Campinas como um dos canais de industrialização e concentração populacional do estado de São Paulo demonstra como o planejamento pode influenciar de forma expressiva no desenvolvimento social e econômico. Sendo assim, o presente trabalho, por meio de respaldo teórico multidisciplinar, analisa a qualidade de vida relacionada à qualidade ambiental, que por sua vez está atrelada à gestão dos recursos naturais e ao planejamento urbano, usando como recorte espacial alguns bairros da cidade de Campinas-SP e demonstrando o potencial que a geografia oferece para esses estudos
Resumo:
Mestrado em Segurança e Higiene no Trabalho.
Resumo:
OBJETIVO: Dentre os efeitos da poluição ambiental na saúde da criança, destaca-se o aumento de internações por pneumonias. O objetivo do estudo foi estimar a associação dessas internações com o aumento dos poluentes atmosféricos. MÉTODOS: Trata-se de estudo ecológico de séries temporais, realizado na cidade de São José dos Campos, SP, nos anos de 2000 e 2001. Foram utilizados dados diários sobre o número de internações por pneumonia, dados diários de poluentes (SO2, O3 e PM10) e de temperatura e umidade do clima. Foram estimadas as correlações entre as variáveis de interesse pelo coeficiente de Pearson. Para estimar a associação entre as internações por pneumonia e a poluição atmosférica, utilizaram-se modelos aditivos generalizados de regressão de Poisson. Foram estimados os acréscimos das internações por pneumonia para o intervalo interquartil para cada um dos poluentes estudados, com um intervalo de confiança de 95% RESULTADOS: Os três poluentes apresentaram efeitos defasados nas internações por pneumonia, iniciada três a quatro dias após a exposição e decaindo rapidamente. Na estimativa de efeito acumulado de oito dias observou-se ao longo desse período que para aumentos de 24,7 µg/m³ na concentração média de PM10 houve um acréscimo de 9,8% nas internações. CONCLUSÕES: O estudo confirma que o potencial deletério dos poluentes do ar sobre a saúde pode ser detectado, também, em cidades de médio porte. A magnitude do efeito foi semelhante ao observado na cidade de São Paulo. Além disso, mostra a elevada susceptibilidade das crianças aos efeitos adversos advindos da exposição aos contaminantes atmosféricos.
Resumo:
OBJETIVO: Avaliar a relação entre poluição do ar e efeitos respiratórios agudos em crianças. MÉTODOS: Foi realizado um estudo ecológico de séries temporais em três unidades públicas de saúde do bairro de Jacarepaguá, município do Rio de Janeiro, entre abril de 2002 e março de 2003. Foram analisados dados diários de PM10, SO2, NO2, CO e O3, e como variáveis de desfecho 45.595 atendimentos pediátricos de emergência por sintomas respiratórios ou específicos por transtornos nas vias aéreas superiores e nas vias aéreas inferiores. Foram incluídas no modelo para controle de confundimento as variáveis referentes à tendência temporal, sazonalidade, temperatura, umidade relativa do ar, precipitação de chuva, infecções respiratórias e os efeitos do calendário (como feriados e finais de semana). Foi empregada a regressão de Poisson via modelos aditivos generalizados para estimar os efeitos dos poluentes e dos fatores de confusão. RESULTADOS: Somente o O3 apresentou resultado positivo e estatisticamente significativo, tanto com todos os atendimentos de emergência por queixas respiratórias como com os atendimentos motivados por sintomas nas vias aéreas inferiores. O efeito foi no mesmo dia da exposição (lag 0). Associação significativa e de sentido inverso ocorreu com o CO e os atendimentos pediátricos por queixas respiratórias. Não se observou resultado significativo com os demais poluentes atmosféricos. CONCLUSÕES: Foram encontradas associações entre indicadores de poluição atmosférica e o número de atendimentos pediátricos de emergência por motivos respiratórios em Jacarepaguá, apesar de os níveis de todos os poluentes monitorados permanecessem abaixo dos limites recomendados durante todo o período de estudos.
Resumo:
OBJETIVO: Estimar a prevalência de sintomas respiratórios e analisar fatores associados, bem como medidas de pico de fluxo expiratório em escolares. MÉTODOS: Estudo descritivo transversal com escolares de dez a 14 anos de Monte Aprazível, SP. Foram aplicados questionários sobre sintomas de asma e de rinite do protocolo International Study of Asthma and Allergies in Childhood, questões sociodemográficas, fatores predisponentes e antecedentes pessoais e familiares. Foram realizadas medidas repetidas do pico de fluxo expiratório nas crianças e dos níveis de concentração de material particulado (MP2,5) e de black carbon. RESULTADOS: A prevalência de sintomas de asma foi de 11% e de 33,2% de rinite; 10,6% apresentaram mais de quatro crises de sibilos nos últimos 12 meses. Antecedentes familiares para bronquite e rinite associaram-se à presença de asma (p = 0,002 e p < 0,001) e de rinite atuais (p < 0,001 e p < 0,001, respectivamente). Para rinite, houve associação com presença de mofo ou rachadura na casa (p = 0,009). Houve maior freqüência de rinite nos meses de junho a outubro, período de safra da cana de açúcar. Prevalência diária de pico de fluxo expiratório abaixo de 20% da mediana de medidas na criança foi maior em dias com maior concentração de MP2,5. CONCLUSÕES: A prevalência de sintomas de asma está abaixo e a de rinite está acima da média nacional. Ainda que dentro dos níveis aceitáveis, a poluição nos períodos de queima da palha da cana-de-açúcar pode contribuir para a exacerbação de episódios de asma e de rinite.
Resumo:
OBJETIVO : Analisar a qualidade do ar em escolas de educação básica e suas condições estruturais e funcionais. MÉTODOS : Foi avaliada a qualidade do ar de 51 escolas (81 salas de aula) de educação básica da cidade de Coimbra, Portugal, tanto na parte interior das salas como na exterior, durante as quatro estações do ano, de 2010 a 2011. Foram avaliadas a temperatura (Tº), umidade relativa (Hr), concentrações de monóxido de carbono (CO), dióxido de carbono (CO 2 ), ozona (O 3 ), dióxido de nitrogênio (NO 2 ), dióxido de enxofre (SO 2 ), compostos orgânicos voláteis (COV), formaldeído e material particulado (PM 10 ), de novembro de 2010 a fevereiro de 2011 (outono/inverno) e de março de 2011 a junho de 2011 (primavera/verão). Procedeu-se ao preenchimento de uma grelha de caracterização das condições estruturais e funcionais das escolas. Aplicaram-se os testes estatísticos t- Student para amostras emparelhadas e o teste t de Wilcoxon. RESULTADOS : Em 47 escolas, as concentrações médias de CO 2 encontravam-se acima da concentração máxima de referência (984 ppm) mencionada na legislação portuguesa. Os valores máximos de concentração encontrados no interior das salas foram críticos, principalmente no outono/inverno (5.320 ppm). As concentrações médias de COV e de PM 10 no interior ultrapassaram a concentração máxima de referência legislada em algumas escolas. Não foram detetados valores relevantes (risco) de CO, formaldeído, NO 2 , SO 2 e O 3 . CONCLUSÕES : Houve maior concentração de poluentes no interior das salas, comparativamente com o exterior. A inadequada ventilação está associada à elevada concentração de CO 2 nas salas de aula.
Resumo:
A prática de exercício físico é considerado condição essencial para a manutenção de uma boa saúde. A faixa etária de frequentadores de ginásios inclui utentes desde os 8 aos 80 anos, incluindo assim os grupos mais sensíveis à poluição do ar interior. Embora exista legislação específica para ginásios, nomeadamente para as condições de implementação, a mesma é reduzida e não contempla a qualidade do ar interior (QAI). O objetivo geral deste estudo consistiu na avaliação da QAI de quatro ginásios existentes na área metropolitana do Porto. O período de amostragem realizou-se entre 2 de Maio e 20 de Junho 2014 e, após a caracterização dos ginásios, foram monitorizados os seguintes parâmetros: partículas ultrafinas (< 100 nm), matéria particulada suspensa no ar de frações PM1, PM2,5, PM4 e PM10, dióxido de carbono, monóxido de carbono, ozono, compostos orgânicos voláteis, formaldeído, temperatura ambiente e humidade relativa durante 24 h/dia em salas com diferentes actividades (sala de musculação e cardiofitness e sala de aulas de grupo). Os resultados da avaliação dos parâmetros físicos e químicos foram comparados com os limiares de proteção e margem de tolerância do Decreto-Lei nº 118/2013 de 20 de Agosto, a Portaria nº 353-A/2013 de 4 de Dezembro e o Diploma que regula a construção, instalação e funcionamento dos ginásios. Os poluentes com maiores níveis de excedência são o dióxido de carbono, compostos orgânicos voláteis e as partículas PM2,5. As excedências devem-se essencialmente à sobrelotação das salas, excesso de atividade física e ventilação insuficiente. A localização da instalação dos ginásios é também um fator de extrema importância, sendo recomendado que este se situe em local pouco influenciado pelo tráfego automóvel, assim como, afastado de locais de possível interferência devido às atividades presentes, como é o caso da restauração existente em centros comerciais.