950 resultados para Plantar Flexion


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: The objective of this study was to analyze the muscle strength and endurance of the proximal and distal lower-extremity muscles in peripheral artery disease (PAD) patients. Methods: Twenty patients with bilateral PAD with symptoms of intermittent claudication and nine control subjects without PAD were included in the study, comprising 40 and 18 legs, respectively. All subjects performed an isokinetic muscle test to evaluate the muscle strength and endurance of the proximal (knee extension and knee flexion movements) and distal (plantar flexion and dorsiflexion movements) muscle groups in the lower extremity. Results: Compared with the control group, the PAD group presented lower muscle strength in knee flexion (-14.0%), dorsiflexion (-26.0%), and plantar flexion (-21.2%) movements (P < 0.05) but similar strength in knee extension movements (P > 0.05). The PAD patients presented a 13.5% lower knee flexion/extension strength ratio compared with the control subjects (P < 0.05), as well as lower muscle endurance in dorsiflexion (-28.1%) and plantar flexion (-17.0%) movements (P < 0.05). The muscle endurance in knee flexion and knee extension movements was similar between PAD patients and the control subjects (P > 0.05). Conclusion: PAD patients present lower proximal and distal muscle strength and lower distal muscle endurance than control patients. Therefore, interventions to improve muscle strength and endurance should be prescribed for PAD patients.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: To analyze and compare the vertical component of ground reaction forces and isokinetic muscle parameters for plantar flexion and dorsiflexion of the ankle between long-distance runners, triathletes, and nonathletes. METHODS: Seventy-five males with a mean age of 30.26 (±6.5) years were divided into three groups: a triathlete group (n=26), a long-distance runner group (n = 23), and a non-athlete control group. The kinetic parameters were measured during running using a force platform, and the isokinetic parameters were measured using an isokinetic dynamometer. RESULTS: The non-athlete control group and the triathlete group exhibited smaller vertical forces, a greater ground contact time, and a greater application of force during maximum vertical acceleration than the long-distance runner group. The total work (180º/s) was greater in eccentric dorsiflexion and concentric plantar flexion for the non-athlete control group and the triathlete group than the long-distance runner group. The peak torque (60º/s) was greater in eccentric plantar flexion and concentric dorsiflexion for the control group than the athlete groups. CONCLUSIONS: The athlete groups exhibited less muscle strength and resistance than the control group, and the triathletes exhibited less impact and better endurance performance than the runners.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Total ankle arthroplasty (TAA) is still not as satisfactory as total hip and total knee arthroplasty. For the TAA to be considered a valuable alternative to ankle arthrodesis, an effective range of ankle mobility must be recovered. The disappointing clinical results of the current generation of TAA are mostly related to poor understanding of the structures guiding ankle joint mobility. A new design (BOX Ankle) has been developed, uniquely able to restore physiologic ankle mobility and a natural relationship between the implanted components and the retained ligaments. For the first time the shapes of the tibial and talar components in the sagittal plane were designed to be compatible with the demonstrated ligament isometric rotation. This resulted in an unique motion at the replaced ankle where natural sliding as well as rolling motion occurs while at the same time full conformity is maintained between the three components throughout the flexion arc. According to prior research, the design features a spherical convex tibial component, a talar component with radius of curvature in the sagittal plane longer than that of the natural talus, and a fully conforming meniscal component. After computer-based modelling and preliminary observations in several trial implantation in specimens, 126 patients were implanted in the period July 2003 – December 2008. 75 patients with at least 6 months follow-up are here reported. Mean age was 62,6 years (range 22 – 80), mean follow-up 20,2 months. The AOFAS clinical score systems were used to assess patient outcome. Radiographs at maximal dorsiflexion and maximal plantar flexion confirmed the meniscalbearing component moves anteriorly during dorsiflexion and posteriorly during plantarflexion. Frontal and lateral radiographs in the patients, show good alignment of the components, and no signs of radiolucency or loosening. The mean AOFAS score was observed to go from 41 pre-op to 74,6 at 6 month follow-up, with further improvement at the following follow-up. These early results reveal satisfactory clinical scores, with good recovery of range of motion and reduction of pain. Radiographic assessment reveals good osteointegration. All these preliminary results confirm biomechanical studies and the validity of this novel ligamentcompatible prosthesis design. Surely it will be important to re-evaluate these patients later.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

La marcha humana es el mecanismo de locomoción por el cual el cuerpo humano se traslada en línea recta gracias a una serie de movimientos coordinados de la pelvis y de las articulaciones del miembro inferior. Frecuentemente se encuentra influenciada por factores biomecánicos, anatómicos o patologías del sistema neuromusculoesquelético que modifican la forma de caminar de cada individuo. La lesión de médula espinal es una de las patologías que afectan el desarrollo normal de los patrones de la marcha por alteración de la movilidad, de la sensibilidad o del sistema nervioso autónomo. Aunque la lesión medular afecta otras funciones, además de la pérdida de función motora y sensorial, la recuperación de la capacidad de caminar es la mayor prioridad identificada por los pacientes durante la rehabilitación. Por ello, el desarrollo de dispositivos que faciliten la rehabilitación o compensación de la marcha es uno de los principales objetivos de diferentes grupos de investigación y empresas. En el contexto del proyecto Hybrid Technological Platform for Rehabilitation, Functional Compensation and Training of Gait in Spinal Cord Injury Patients se ha desarrollado un dispositivo que combina una órtesis activa (exoesqueleto) y un andador motorizado. Este sistema, como otros dispositivos, tiene el movimiento humano como estándar de referencia, no obstante no se evalúa de manera habitual, cómo es el patrón de la marcha reproducido y su similitud o diferencias con la marcha humana, o las modificaciones o adaptaciones en la interacción con el cuerpo del paciente. El presente estudio trata de examinar las características de la marcha normal en diversos grupos de población, y las diferencias con el patrón de marcha lenta. Finalmente, se pretende evaluar qué modificaciones y adaptaciones sufre el patrón de marcha lenta teórico al ser reproducido por el exoesqueleto. La presente investigación consiste en un estudio cuantitativo transversal desarrollado en dos etapas: estudio 1 y estudio 2. En el estudio 1 se analizó el patrón de la marcha a velocidad libremente seleccionada (normal) y el patrón de la marcha a velocidad lenta (0.25m/s) en 62 sujetos distribuidos en grupos considerando el sexo y los percentiles 25, 50 y 75 de estatura de la población española. Durante el estudio 2 se analizó el patrón de la marcha lenta reproducido por el dispositivo Hybrid a diferentes porcentajes de peso corporal (30%, 50% y 70%) en diez sujetos seleccionados aleatoriamente de la muestra del estudio 1. En ambos estudios se obtuvieron variables espacio-temporales y cinemáticas mediante un sistema de captura de movimiento con 6 cámaras distribuidas a lo largo de un pasillo de marcha. Se calcularon las medias, las desviaciones estándar y el 95% de intervalo de confianza, y el nivel alfa de significación se estableció en α=0.05 para todas las pruebas estadísticas. Las principales diferencias en el patrón normal de la marcha se encontraron en los parámetros cinemáticos de hombres y mujeres, aunque también se presentaron diferencias entre los grupos en función de la estatura. Las mujeres mostraron mayor flexión de cadera y rodilla, y mayor extensión de tobillo que los hombres durante el ciclo normal, aunque la basculación lateral de la pelvis, mayor en las mujeres, y el desplazamiento lateral del centro de gravedad, mayor en los hombres, fueron los parámetros identificados como principales discriminantes entre sexos. La disminución de la velocidad de la marcha mostró similares adaptaciones y modificaciones en hombres y en mujeres, presentándose un aumento de la fase de apoyo y una disminución de la fase de oscilación, un retraso de los máximos y mínimos de flexoextensión de cadera, rodilla y tobillo, y una disminución del rango articular en las tres articulaciones. Asimismo, la basculación lateral de la pelvis y el movimiento vertical del centro de gravedad disminuyeron, mientras que el movimiento lateral del centro de gravedad y el ancho de paso aumentaron. Durante la evaluación del patrón de la marcha reproducido por el exoesqueleto se observó que las tres articulaciones del miembro inferior disminuían el rango de movimiento por la falta de fuerza de los motores para contrarrestar el peso corporal, incluso con un 70% de descarga de peso. Además, la transferencia de peso se encontró limitada por la falta de movimiento de la pelvis en el plano frontal y se sustituyó por un aumento de la inclinación del tronco y, por tanto, del movimiento lateral del centro de gravedad. Este hecho, junto al aumento del desplazamiento vertical del centro de gravedad, hizo del patrón de la marcha reproducido por el exoesqueleto un movimiento poco eficiente. En conclusión, se establecen patrones de marcha normal diferenciados por sexos, siendo la basculación lateral de la pelvis y el movimiento lateral del centro de gravedad los parámetros discriminantes más característicos entre sexos. Comparando la marcha a velocidad libremente seleccionada y la velocidad lenta, se concluye que ambos sexos utilizan estrategias similares para adaptar el patrón de la marcha a una velocidad lenta y se mantienen las características diferenciadoras entre hombres y mujeres. En relación a la evaluación del dispositivo Hybrid, se deduce que la falta de movimiento lateral de la pelvis condiciona la transferencia de peso y el aumento del rango de movimiento del centro de gravedad y, en consecuencia, tiene como resultado un patrón de la marcha poco eficiente. Este patrón no resultaría indicado para los procesos de rehabilitación o recuperación de la marcha, aunque podría considerarse adecuado para la compensación funcional de la bipedestación y la locomoción. ABSTRACT The human walking is a means of moving body forward using a repetitious and coordinated sequence of pelvis and lower limb motions. It is frequently influenced by biomechanical and anatomical factors or by musculoskeletal pathologies which modify the way of walking. The spinal injury is one of those pathologies which affect the normal pattern of walking, due to the alteration of the mobility, the sensory or the autonomic nervous system. Although the spinal injury affects many other body functions, apart from the motor and sensory ones, the main priority for patients is to recover the ability of walking. Consequently, the main objective of many research groups and private companies is the development of rehabilitation and compensation devices for walking. In this context, the Hybrid Technological Platform for Rehabilitation, Functional Compensation and Training of Gait in Spinal Cord Injury Patients project has developed a device which integrates an exoskeleton and a motorized smart walker. This system, as other similar devices, has the human movement as standard reference. Nevertheless, these devices are not usually evaluated on the way they reproduce the normal human pattern or on the modifications and in the interactions with the patient’s body. The aim of the present study is to examine the normal walking characteristics, to analyze the differences between self-selected and low speed walking patterns, and to evaluate the modifications and adaptations of walking pattern when it is reproduced by the exoskeleton. The present research is a quantitative cross-sectional study carried out in two phases: study 1 and study 2. During the study 1, the self-selected and the low speed (0.25m/s) walking patterns were analyzed in sixty-two people distributed in groups, according to sex and 25th, 50th and 75th percentiles of height for Spanish population. The study 2 analyzed the low speed walking pattern reproduced by the Hybrid system in three conditions: 30%, 50% and 70% of body weight support. To do this, ten subjects were randomly selected and analyzed from the people of study 1. An optoelectronic system with six cameras was used to obtain spatial, temporal and kinematic parameters in both studies. Means, standard deviations and 95% confidence intervals of the study were calculated. The alpha level of significance was set at α=0.05 for all statistical tests. The main differences in normal gait pattern were found in kinematic parameters between men and women. The hip and the knee were more flexed and the ankle plantar flexion was higher in women than in men during normal gait cycle. Although the greater pelvic obliquity of women and the higher lateral movement of center of gravity of men were the most relevant discriminators between male and female gait patterns. Comparing self-selected and low speed walking patterns, both sexes showed similar adaptations and modifications. At low speed walking, men and women increased the stance phase ratio and decreased the swing phase ratio. The maximum and minimum peak flexion of hip, knee and ankle appeared after and the range of motion of them decreased during low speed walking. Furthermore, the pelvic obliquity and the vertical movement of the center of gravity decreased, whereas the lateral movement of center of gravity and step width increased. Evaluating the gait pattern reproduced by the exoskeleton, a decrease of lower limb range of motion was observed. This was probably due to the lack of strength of the engines, which were not able to control the body weight, even with the 70% supported. Moreover, the weight transfer from one limb to the contralateral side was restricted due to the lack of pelvis obliquity. This movement deficiency was replaced by the lateral torso sway and, consequently, the increase of lateral movement of the center of gravity. This fact, as well as the increase of the vertical displacement of the center of gravity, made inefficient the gait pattern reproduced by the exoskeleton. In conclusion, different gait patterns of both sexes have been determined, being pelvis obliquity and lateral movement of center of gravity the most relevant discriminators between male and female gait patterns. Comparing self-selected and low speed walking patterns, it was concluded that both sexes use similar strategies for adapting the gait pattern to a low speed, and therefore, the differentiating characteristics of normal gait are maintained. Regarding the Hybrid system evaluation, it was determined that the gait pattern reproduced by the exoskeleton is inefficient. This was due to the lack of pelvis obliquity and the increase of the center of gravity displacement. Consequently, whereas the walking pattern reproduced by the exoskeleton would not be appropriated for the rehabilitation process, it could be considered suitable for functional compensation of walking and standing.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

To examine the impact of insulin resistance on the insulin-dependent and insulin-independent portions of muscle glycogen synthesis during recovery from exercise, we studied eight young, lean, normoglycemic insulin-resistant (IR) offspring of individuals with non-insulin-dependent diabetes mellitus and eight age-weight matched control (CON) subjects after plantar flexion exercise that lowered muscle glycogen to approximately 25% of resting concentration. After approximately 20 min of exercise, intramuscular glucose 6-phosphate and glycogen were simultaneously monitored with 31P and 13C NMR spectroscopies. The postexercise rate of glycogen resynthesis was nonlinear. Glycogen synthesis rates during the initial insulin independent portion (0-1 hr of recovery) were similar in the two groups (IR, 15.5 +/- 1.3 mM/hr and CON, 15.8 +/- 1.7 mM/hr); however, over the next 4 hr, insulin-dependent glycogen synthesis was significantly reduced in the IR group [IR, 0.1 +/- 0.5 mM/hr and CON, 2.9 +/- 0.2 mM/hr; (P < or = 0.001)]. After exercise there was an initial rise in glucose 6-phosphate concentrations that returned to baseline after the first hour of recovery in both groups. In summary, we found that following muscle glycogen-depleting exercise, IR offspring of parents with non-insulin-dependent diabetes mellitus had (i) normal rates of muscle glycogen synthesis during the insulin-independent phase of recovery from exercise and (ii) severely diminished rates of muscle glycogen synthesis during the subsequent recovery period (2-5 hr), which has previously been shown to be insulin-dependent in normal CON subjects. These data provide evidence that exercise and insulin stimulate muscle glycogen synthesis in humans by different mechanisms and that in the IR subjects the early response to stimulation by exercise is normal.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

1.1 Background and Purpose: Ultrasound guided sciatic nerve blockade has rapid onset but at 24 hours pain is greater than nerve stimulator techniques. Injection of the nerve branches or trunk and sub-sheath blockade increase success and reduce onset times but risk injury. This study mapped needle coordinates for sciatic nerve blockade with nerve stimulation and its relation to postoperative pain scores. 1.2 Method: Angle and distance of the needle tip and infusion catheter from the popliteal sciatic nerve at which stimulated plantar flexion occurred were measured. Pain scores at postanesthesia unit discharge and 24 hours were recorded. 1.3 Results: 81% of opioid naïve patients reported immediate analgesia and 20.8% at 24 hours. In opioid tolerant patients 56.8% reported immediate analgesia and 9.1% at 24 hours. Plantar flexion was observed with the needle in the posterior medial quadrant near the sciatic nerve. Opioid tolerant patients reported adequate analgesia when the needle was located more medially and proximally to the sciatic nerve. 1.4 Conclusion: Stimulated plantar flexion is isolated to a narrow angular range in the posterior medial quadrant adjacent to the sciatic nerve. Opioid tolerant patients report adequate analgesia if the needle and catheter are more medial and proximal to the nerve surface.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study determined roller massager (RM) effectiveness on ankle plantar flexors’ recovery after exercise-induced muscle damage (EIMD) stimulus. Two experiments were conducted. The first experiment (n=10) examined functional [i.e., ankle plantar flexion maximal voluntary isometric contraction (MVIC) and submaximal (30% of MVIC) sustained force; ankle dorsiflexion maximal range of motion and resistance to stretch; and pain pressure threshold] and morphological [medial gastrocnemius (MG) cross sectional area, thickness, fascicle length, and fascicle angle] variables, before and immediately, 1h, 24h, 48h, and 72 after EIMD. In the second experiment (n=10), changes in MG deoxyhemoglobin concentration kinetics (velocity and amplitude) during a submaximal sustained force test were observed before and 48h after EIMD. Participants performed both experiments twice, with and without (NRM) the application of a RM (6 × 45 seconds with 20 seconds rest between sets). RM intervention did not alter plantar flexors’ strength and flexibility impairment after EIMD, as well the MG morphology and oxygenation kinetics (p>0.05). On the other hand, a strong tendency for an acute (within 1 hour) change of ipsilateral (post-effects: RM=+19%, NRM=-5%, p=0.032) and contralateral (p=0.095) MG pain pressure threshold was observed. In conclusion, the present results suggest that a roller massager has no effect on muscular performance, morphology, and oxygenation recovery after EIMD, except for muscle pain pressure threshold (i.e., a soreness). Thus, RM may have potential application in recovery for people with increased muscle soreness, if performed immediately before a physical task.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Although a lowered medial longitudinal arch has been cited as a causal factor in plantar fasciitis, there is little experimental evidence linking arch motion to the pathogenesis of the condition. This study investigated the sagittal movement of the arch in subjects with and without plantar fasciitis during gait. Methods: Digital fluoroscopy was used to acquire dynamic lateral radiographs from 10 subjects with unilateral plantar fasciitis and 10 matched control subjects. The arch angle and the first metatarsophalangeal joint angle were digitized and their respective maxima recorded. Sagittal movement of the arch was defined as the angular change between heel strike and the maximum arch angle observed during the stance phase of gait. The-thickness of the proximal plantar fascia was determined from sagittal sonograms of both feet. ANOVA models were used to identify differences between limbs with respect to each dependent variable. Relationships between arch movement and fascial thickness were investigated using correlations. Results: There was no significant difference in either the movement or maximum arch angle between limbs. However, subjects with plantar fasciitis were found to have a larger metatarsophalangeal joint angle than controls (P < 0.05). Whereas the symptomatic and asymptomatic plantar fascia were thicker than those of control feet (P < 0.05), significant correlations were noted between fascial thickness and peak arch and metatarsophalangeal joint angles (P < 0.05) in the symptomatic limb only. Conclusions: Neither abnormal shape nor movement of the arch are associated with chronic plantar fasciitis. However, arch mechanics may influence the severity of plantar fasciitis once the condition is present. Digital flexion, in contrast, has a protective role in what might be a bilateral disease process.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A modified straight leg raising (SLR) in which ankle dorsiflexion is performed before hip flexion has been suggested to diagnose distal neuropathies such as tarsal tunnel syndrome. This study evaluates the clinical hypothesis that strain in the nerves around the ankle and foot caused by ankle dorsiflexion can be further increased with hip flexion. Linear displacement transducers were inserted into the sciatic, tibial, and plantar nerves and plantar fascia of eight embalmed cadavers to measure strain during the modified SLR. Nerve excursion was measured with a digital calliper. Ankle dorsiflexion resulted in a significant strain and distal. excursion of the tibial nerve. With the ankle in dorsiflexion, the proximal excursion and tension increase in the sciatic nerve associated with hip flexion were transmitted distally along the nerve from the hip to beyond the ankle. As hip flexion had an impact on the nerves around the ankle and foot but not on the plantar fascia, the modified SLR may be a useful test to differentially diagnose plantar heel pain. Although the modified SLR caused the greatest increase in nerve strain nearest the moving joint, mechanical forces acting on peripheral nerves are transmitted well beyond the moving joint. (c) 2006 Orthopaedic Research Society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Diabetic neuropathy leads to progressive loss of sensation, lower-limb distal muscle atrophy, autonomic impairment, and gait alterations that overload feet. This overload has been associated with plantar ulcers even with consistent daily use of shoes. We sought to investigate and compare the influence of diabetic neuropathy and plantar ulcers in the clinical history of diabetic neuropathic patients on plantar sensitivity, symptoms, and plantar pressure distribution during gait while patients wore their everyday shoes. Methods: Patients were categorized into three groups: a control group (CG; n = 15), diabetic patients with a history of neuropathic ulceration (DUG; n = 8), and diabetic patients without a history of ulceration (DG; n = 10). Plantar pressure variables were measured by Pedar System shoe insoles in five plantar regions during gait while patients wore their own shoes. Results: No statistical difference between neuropathic patients with and without a history of plantar ulcers was found in relation to symptoms, tactile sensitivity, and duration of diabetes. Diabetic patients without ulceration presented the lowest pressure-time integral under the heel (72.1 +/- 16.1 kPa x sec; P=.0456). Diabetic patients with a history of ulceration presented a higher pressure-time integral at the midfoot compared to patients in the control group (59.6 +/- 23.6 kPa x sec x 45.8 +/- 10.4 kPa x sec; P = .099), and at the lateral forefoot compared to diabetic patients without ulceration (70.9 +/- 17.7 kPa sec x 113.2 +/- 61.1 kPa x sec, P = .0193). Diabetic patients with ulceration also presented the lowest weight load under the hallux (0.06 +/- 0.02%, P = .0042). Conclusions: Although presenting a larger midfoot area, diabetic neuropathic patients presented greater pressure-time integrals and relative loads over this region. Diabetic patients with ulceration presented an altered dynamic plantar pressure pattern characterized by overload even when wearing daily shoes. Overload associated with a clinical history of plantar ulcers indicates future appearance of plantar ulcers. (J Am Podiatr Med Assoc 99(4): 285-294, 2009)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Phrenic nerve transfer has been used for treating lesions of the brachial plexus since 1970. Although, today, surgeons are more experienced with the technique, there are still widespread concerns about its effects on pulmonary function. This study was undertaken to evaluate the effectiveness and safety of this procedure. METHODS: Fourteen patients with complete palsy of the upper limb were submitted to phrenic nerve transfer as part of a strategy for surgical reconstruction of their plexuses. Two patients were lost to follow-up, and 2 patients were followed for less than 2 years. Of the remaining 10 patients, 9 (90%) were male. The lesions affected both sides equally. The mean age of the patients was 24.8 years (range, 14-43 years), and the mean interval from injury to surgery was 6 months (range, 3-9 months). The phrenic nerve was always transferred to the musculocutaneous nerve, and a nerve graft (mean length, 8 cm; range, 4.5-12 cm) was necessary in all cases. RESULTS: There was no major complication related to the surgery. Seven patients (70%) recovered functional level biceps strength (Medical Research Council grade >= 3). All of the patients exhibited a transient decrease in pulmonary function tests, but without clinical respiratory problems. CONCLUSION: On the basis of our small series and data from the literature, we conclude that phrenic nerve transfer in well-selected patients is a safe and effective procedure for recovering biceps function.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Plantar fasciitis is the third most frequent injury in runners. Despite its high prevalence, its pathogenesis remains inconclusive. The literature reports overload as the basic mechanism for its development. However, the way that these plantar loads are distributed on the foot surface of runners with plantar fasciitis and the effects of pain on this mechanical factor has not yet been investigated. Therefore, the aim of this study was to evaluate and compare the plantar pressure distributions during running in runners with symptom or history of plantar fasciitis and runners without the disease. Methods: Forty-five recreational runners with plantar fasciitis (30 symptomatic and 15 with previous history of the disease) and 60 runners without plantar fasciitis (control group) were evaluated. Pain was assessed by a visual analogue scale. All runners were evaluated by means of the Pedar system insoles during running forty meters at a speed of 12(5%) km/h, using standard sport footwear. Two-way ANOVAS were employed to investigate the main and interaction effects between groups and plantar areas. Findings: No interaction effects were found for any of the investigated variables: peak pressure (P=0.61), contact area (P=0.38), contact time (P=0.91), and the pressure-time integral (P=0.50). Interpretation: These findings indicated that the patterns of plantar pressure distribution were not affected in recreational runners with plantar fasciitis when compared to control runners. Pain also did not interfere with the dynamic patterns of the plantar pressure distributions. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The type of surface used for running can influence the load that the locomotor apparatus will absorb and the load distribution could be related to the incidence of chronic injuries. As there is no consensus on how the locomotor apparatus adapts to loads originating from running Surfaces with different compliance, the objective of this study was to investigate how loads are distributed over the plantar surface while running on natural grass and on a rigid surface-asphalt. Forty-four adult runners with 4 3 years of running experience were evaluated while running at 12 km/h for 40 m wearing standardised running shoes and Pedar insoles (Novel). Peak pressure, contact time and contact area were measured in six regions: lateral, central and medial rearfoot, midfoot, lateral and media] forefoot. The Surfaces and regions were compared by three ANOVAS (2 x 6). Asphalt and natural grass were statistically different in all variables. Higher peak pressures were observed on asphalt at the central (p < 0.001) [grass: 303.8(66.7) kPa; asphalt: 342.3(76.3) kPa] and lateral rearfoot (p < 0.001) [grass: 312.7(75.8) kPa: asphalt: 350.9(98.3) kPa] and lateral forefoot (p < 0.001) [grass: 221.5(42.9) kPa asphalt: 245.3(55.5) kPa]. For natural grass, contact time and contact area were significantly greater at the central rearfoot (p < 0.001). These results suggest that natural grass may be a Surface that provokes lighter loads on the rearfoot and forefoot in recreational runners. (C) 2008 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The purpose of this study was to investigate the ankle range of motion during neuropathic gait and its influence on plantar pressure distribution in two phases during stance: at heel-strike and at push-off. Methods: Thirty-one adults participated in this study (control group, n = 16; diabetic neuropathic group, n = 15). Dynamic ankle range of motion (electrogoniometer) and plantar pressures (PEDAR-X system) were acquired synchronously during walking. Plantar pressures were evaluated at rearfoot. midfoot and forefoot during the two phases of stance. General linear model repeated measures analysis of variance was applied to investigate relationships between groups, areas and stance phases. Findings: Diabetic neuropathy patients walked using a smaller ankle range of motion in stance phase and smaller ankle flexion at heel-strike (P = 0.0005). Peak pressure and pressure-time integral values were higher in the diabetic group in the midfoot at push-off phase when compared to heel-strike phase. On the other hand, the control group showed similar values of peak pressure in midfoot during both stance phases. Interpretation: The ankle mobility reduction observed could be associated to altered plantar pressure distribution observed in neuropathic subjects. Results demonstrated that midfoot and forefoot play a different role in subjects with neuropathy by receiving higher loads at push-off phase that are probably due to smaller ankle flexion at stance phase. This may explain the higher loads in anterior areas of the foot observed in diabetic neuropathy subjects and confirm an inadequate foot rollover associated to the smaller ankle range of motion at the heel-strike phase. (C) 2009 Elsevier Ltd. All rights reserved.