988 resultados para PROTOCOL FOR SURGERY


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background/purpose: Gallstones and cholelithiasis are being increasingly diagnosed in children owing to the widespread use of ultrasonography. The treatment of choice is cholecystectomy, and routine intraoperative cholangiography is recommended to explore the common bile duct. The objectives of this study were to describe our experience with the management of gallstone disease in childhood over the last 18 years and to propose an algorithm to guide the approach to cholelithiasis in children based on clinical and ultrasonographic findings. Methods: The data for this study were obtained by reviewing the records of all patients with gallstone disease treated between January 1994 and October 2011. The patients were divided into the following 5 groups based on their symptoms: group 1, asymptomatic; group 2, nonbiliary obstructive symptoms; group 3, acute cholecystitis symptoms; group 4, a history of biliary obstructive symptoms that were completely resolved by the time of surgery; and group 5, ongoing biliary obstructive symptoms. Patients were treated according to an algorithm based on their clinical, ultrasonographic, and endoscopic retrograde cholangiopancreatography (ERCP) findings. Results: A total of 223 patients were diagnosed with cholelithiasis, and comorbidities were present in 177 patients (79.3%). The most common comorbidities were hemolytic disorders in 139 patients (62.3%) and previous bariatric surgery in 16 (7.1%). Although symptoms were present in 134 patients (60.0%), cholecystectomy was performed for all patients with cholelithiasis, even if they were asymptomatic; the surgery was laparoscopic in 204 patients and open in 19. Fifty-six patients (25.1%) presented with complications as the first sign of cholelithiasis (eg, pancreatitis, choledocolithiasis, or acute calculous cholecystitis). Intraoperative cholangiography was indicated in 15 children, and it was positive in only 1 (0.4%) for whom ERCP was necessary to extract the stone after a laparoscopic cholecystectomy (LC). Preoperative ERCP was performed in 11 patients to extract the stones, and a hepaticojejunostomy was indicated in 2 patients. There were no injuries to the hepatic artery or common bile duct in our series. Conclusions: Based on our experience, we can propose an algorithm to guide the approach to cholelithiasis in the pediatric population. The final conclusion is that LC results in limited postoperative complications in children with gallstones. When a diagnosis of choledocolithiasis or dilation of the choledocus is made, ERCP is necessary if obstructive symptoms persist either before or after an LC. Intraoperative cholangiography and laparoscopic common bile duct exploration are not mandatory. Published by Elsevier Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: To determine the micro-hardness profile of two dual cure resin cements (RelyX - U100 (R), 3M-ESPE and Panavia F 2.0 (R), Kuraray) used for cementing fiber-reinforced resin posts (Fibrekor (R) - Jeneric Pentron) under three different curing protocols and two water storage times. Material and methods: Sixty 16mm long bovine incisor roots were endodontically treated and prepared for cementation of the Fibrekor posts. The cements were mixed as instructed, dispensed in the canal, the posts were seated and the curing performed as follows: a) no light activation; b) light-activation immediately after seating the post, and; c) light-activation delayed 5 minutes after seating the post. The teeth were stored in water and retrieved for analysis after 7 days and 3 months. The roots were longitudinally sectioned and the microhardness was determined at the cervical, middle and apical regions along the cement line. The data was analyzed by the three-way ANOVA test (curing mode, storage time and thirds) for each cement. The Tukey test was used for the post-hoc analysis. Results: Light-activation resulted in a significant increase in the microhardness. This was more evident for the cervical region and for the Panavia cement. Storage in water for 3 months caused a reduction of the micro-hardness for both cements. The U100 cement showed less variation in the micro-hardness regardless of the curing protocol and storage time. Conclusions: The micro-hardness of the cements was affected by the curing and storage variables and were material-dependent.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents the treatment protocol of maxillofacial surgery in the rehabilitation process of cleft lip and palate patients adopted at HRAC-USP. Maxillofacial surgeons are responsible for the accomplishment of two main procedures, alveolar bone graft surgery and orthognathic surgery. The primary objective of alveolar bone graft is to provide bone tissue for the cleft site and then allow orthodontic movements for the establishment of an an adequate occlusion. When performed before the eruption of the maxillary permanent canine, it presents high rates of success. Orthognathic surgery aims at correcting maxillomandibular discrepancies, especially anteroposterior maxillary deficiencies, commonly observed in cleft lip and palate patients, for the achievement of a functional occlusion combined with a balanced face.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aims of this study were to analyse the validity, sensitivity and specificity of the protocol of oro-facial myofunctional evaluation with scores (OMES) for oro-facial myofunctional disorder (OMD) diagnosis in young and adult subjects. Eighty subjects were examined. The OMES was validated against the Nordic Orofacial Test-Screening (NOT-S) protocol (criterion validity) (Spearman correlation test). The construct validity was tested by analysis of the ability of the OMES (i) to differentiate healthy subjects (n = 22) from temporomandibular disorder (TMD) patients (n = 22), which frequently have OMD (MannWhitney test) and (ii) to measure the changes that occurred in a subgroup with TMD between the period before and after oro-facial myofunctional therapy (T group, n = 15) (Wilcoxon test). Two speech therapists trained with the OMES participated as examiners (E). There was a statistically significant correlation between the OMES and NOT-S protocols, which was negative because the two scales are inverse (r = -0.86, P < 0.01). There was a significant difference between the healthy and TMD subjects regarding the oro-facial myofunctional status (OMES total score, P = 0.003). After therapy, the T group showed improvement in the oro-facial myofunctional status (OMES total score, P = 0.001). Inter- and intra-examiner agreement was moderate, and the reliability coefficients ranged from good to excellent. The OMES protocol presented mean sensitivity and specificity = 0.80, positive predictive value = 0.76 and negative predictive value = 0.84. Conclusion: The OMES protocol is valid and reliable for clinical evaluation of young and adult subjects, among them patients with TMD.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Pesquisa e Desnsenvolvimento Tecnologico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Primary stability of stems in cementless total hip replacements is recognized to play a critical role for long-term survival and thus for the success of the overall surgical procedure. In Literature, several studies addressed this important issue. Different approaches have been explored aiming to evaluate the extent of stability achieved during surgery. Some of these are in-vitro protocols while other tools are coinceived for the post-operative assessment of prosthesis migration relative to the host bone. In vitro protocols reported in the literature are not exportable to the operating room. Anyway most of them show a good overall accuracy. The RSA, EBRA and the radiographic analysis are currently used to check the healing process of the implanted femur at different follow-ups, evaluating implant migration, occurance of bone resorption or osteolysis at the interface. These methods are important for follow up and clinical study but do not assist the surgeon during implantation. At the time I started my Ph.D Study in Bioengineering, only one study had been undertaken to measure stability intra-operatively. No follow-up was presented to describe further results obtained with that device. In this scenario, it was believed that an instrument that could measure intra-operatively the stability achieved by an implanted stem would consistently improve the rate of success. This instrument should be accurate and should give to the surgeon during implantation a quick answer concerning the stability of the implanted stem. With this aim, an intra-operative device was designed, developed and validated. The device is meant to help the surgeon to decide how much to press-fit the implant. It is essentially made of a torsional load cell, able to measure the extent of torque applied by the surgeon to test primary stability, an angular sensor that measure the relative angular displacement between stem and femur, a rigid connector that enable connecting the device to the stem, and all the electronics for signals conditioning. The device was successfully validated in-vitro, showing a good overall accuracy in discriminating stable from unstable implants. Repeatability tests showed that the device was reliable. A calibration procedure was then performed in order to convert the angular readout into a linear displacement measurement, which is an information clinically relevant and simple to read in real-time by the surgeon. The second study reported in my thesis, concerns the evaluation of the possibility to have predictive information regarding the primary stability of a cementless stem, by measuring the micromotion of the last rasp used by the surgeon to prepare the femoral canal. This information would be really useful to the surgeon, who could check prior to the implantation process if the planned stem size can achieve a sufficient degree of primary stability, under optimal press fitting conditions. An intra-operative tool was developed to this aim. It was derived from a previously validated device, which was adapted for the specific purpose. The device is able to measure the relative micromotion between the femur and the rasp, when a torsional load is applied. An in-vitro protocol was developed and validated on both composite and cadaveric specimens. High correlation was observed between one of the parameters extracted form the acquisitions made on the rasp and the stability of the corresponding stem, when optimally press-fitted by the surgeon. After tuning in-vitro the protocol as in a closed loop, verification was made on two hip patients, confirming the results obtained in-vitro and highlighting the independence of the rasp indicator from the bone quality, anatomy and preserving conditions of the tested specimens, and from the sharpening of the rasp blades. The third study is related to an approach that have been recently explored in the orthopaedic community, but that was already in use in other scientific fields. It is based on the vibration analysis technique. This method has been successfully used to investigate the mechanical properties of the bone and its application to evaluate the extent of fixation of dental implants has been explored, even if its validity in this field is still under discussion. Several studies have been published recently on the stability assessment of hip implants by vibration analysis. The aim of the reported study was to develop and validate a prototype device based on the vibration analysis technique to measure intra-operatively the extent of implant stability. The expected advantages of a vibration-based device are easier clinical use, smaller dimensions and minor overall cost with respect to other devices based on direct micromotion measurement. The prototype developed consists of a piezoelectric exciter connected to the stem and an accelerometer attached to the femur. Preliminary tests were performed on four composite femurs implanted with a conventional stem. The results showed that the input signal was repeatable and the output could be recorded accurately. The fourth study concerns the application of the device based on the vibration analysis technique to several cases, considering both composite and cadaveric specimens. Different degrees of bone quality were tested, as well as different femur anatomies and several levels of press-fitting were considered. The aim of the study was to verify if it is possible to discriminate between stable and quasi-stable implants, because this is the most challenging detection for the surgeon in the operation room. Moreover, it was possible to validate the measurement protocol by comparing the results of the acquisitions made with the vibration-based tool to two reference measurements made by means of a validated technique, and a validated device. The results highlighted that the most sensitive parameter to stability is the shift in resonance frequency of the stem-bone system, showing high correlation with residual micromotion on all the tested specimens. Thus, it seems possible to discriminate between many levels of stability, from the grossly loosened implant, through the quasi-stable implants, to the definitely stable one. Finally, an additional study was performed on a different type of hip prosthesis, which has recently gained great interest thus becoming fairly popular in some countries in the last few years: the hip resurfacing prosthesis. The study was motivated by the following rationale: although bone-prosthesis micromotion is known to influence the stability of total hip replacement, its effect on the outcome of resurfacing implants has not been investigated in-vitro yet, but only clinically. Thus the work was aimed at verifying if it was possible to apply to the resurfacing prosthesis one of the intraoperative devices just validated for the measurement of the micromotion in the resurfacing implants. To do that, a preliminary study was performed in order to evaluate the extent of migration and the typical elastic movement for an epiphyseal prosthesis. An in-vitro procedure was developed to measure micromotions of resurfacing implants. This included a set of in-vitro loading scenarios that covers the range of directions covered by hip resultant forces in the most typical motor-tasks. The applicability of the protocol was assessed on two different commercial designs and on different head sizes. The repeatability and reproducibility were excellent (comparable to the best previously published protocols for standard cemented hip stems). Results showed that the procedure is accurate enough to detect micromotions of the order of few microns. The protocol proposed was thus completely validated. The results of the study demonstrated that the application of an intra-operative device to the resurfacing implants is not necessary, as the typical micromovement associated to this type of prosthesis could be considered negligible and thus not critical for the stabilization process. Concluding, four intra-operative tools have been developed and fully validated during these three years of research activity. The use in the clinical setting was tested for one of the devices, which could be used right now by the surgeon to evaluate the degree of stability achieved through the press-fitting procedure. The tool adapted to be used on the rasp was a good predictor of the stability of the stem. Thus it could be useful for the surgeon while checking if the pre-operative planning was correct. The device based on the vibration technique showed great accuracy, small dimensions, and thus has a great potential to become an instrument appreciated by the surgeon. It still need a clinical evaluation, and must be industrialized as well. The in-vitro tool worked very well, and can be applied for assessing resurfacing implants pre-clinically.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Critical lower limb ischemia is a severe disease. A common approach is infrainguinal bypass. Synthetic vascular prosthesis, are good conduits in high-flow low-resistance conditions but have difficulty in their performance as small diameter vessel grafts. A new approach is the use of native decellularized vascular tissues. Cell-free vessels are expected to have improved biocompatibility when compared to synthetic and are optimal natural 3D matrix templates for driving stem cell growth and tissue assembly in vivo. Decellularization of tissues represent a promising field for regenerative medicine, with the aim to develop a methodology to obtain small-diameter allografts to be used as a natural scaffold suited for in vivo cell growth and pseudo-tissue assembly, eliminating failure caused from immune response activation. Material and methods. Umbilical cord-derived mesenchymal cells isolated from human umbilical cord tissue were expanded in advanced DMEM. Immunofluorescence and molecular characterization revealed a stem cell profile. A non-enzymatic protocol, that associate hypotonic shock and low-concentration ionic detergent, was used to decellularize vessel segments. Cells were seeded cell-free scaffolds using a compound of fibrin and thrombin and incubated in DMEM, after 4 days of static culture they were placed for 2 weeks in a flow-bioreactor, mimicking the cardiovascular pulsatile flow. After dynamic culture, samples were processed for histological, biochemical and ultrastructural analysis. Discussion. Histology showed that the dynamic culture cells initiate to penetrate the extracellular matrix scaffold and to produce components of the ECM, as collagen fibres. Sirius Red staining showed layers of immature collagen type III and ultrastructural analysis revealed 30 nm thick collagen fibres, presumably corresponding to the immature collagen. These data confirm the ability of cord-derived cells to adhere and penetrate a natural decellularized tissue and to start to assembly into new tissue. This achievement makes natural 3D matrix templates prospectively valuable candidates for clinical bypass procedures

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Piezoelectric instrumentation seems to offer 3 important advantages for cutting bone structures. Be more precise because it is produced by micro-vibrations from the cutting insert. Be safer because the ultrasonic frequency used does not affect soft tissue. Thirdly, the less invasive cutting action produces minor tissue damage and consequently probably a better healing Aim of the Study: The aim of this study is to evaluate the effectiveness of piezoelectric device capability in maxillo-facial surgery, in order to take advantage of these favourable capacity. Material and Methods: Considering the several potential application of the piezoelectric technology in Orthognathic, Oncologic and Extractive surgery, we would like to design protocols in order to verify how this new device can modify the surgical technique, the surgical time, the patients healing and its quality of life. Results: Due to the precise Piezosurgery cut, we can manage the Cad-Cam-Custom Made plates protocol in Oncologic Surgery and in Orthognatic Surgery increasing our percentage of comparison between the 3D preoperative plan and the surgical execution. We also found a better quality of life impaction in Patient who underwent and extractive surgery Conclusion: Piezosurgery device seems to be a strong surgical aid were safe and precise cut are needed and its capability to reduce the discomfort Patients need to be study in deep also in major surgery like Orthognatic and Oncologic surgery.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Osteoarticular allograft is one possible treatment in wide surgical resections with large defects. Performing best osteoarticular allograft selection is of great relevance for optimal exploitation of the bone databank, good surgery outcome and patient’s recovery. Current approaches are, however, very time consuming hindering these points in practice. We present a validation study of a software able to perform automatic bone measurements used to automatically assess the distal femur sizes across a databank. 170 distal femur surfaces were reconstructed from CT data and measured manually using a size measure protocol taking into account the transepicondyler distance (A), anterior-posterior distance in medial condyle (B) and anterior-posterior distance in lateral condyle (C). Intra- and inter-observer studies were conducted and regarded as ground truth measurements. Manual and automatic measures were compared. For the automatic measurements, the correlation coefficients between observer one and automatic method, were of 0.99 for A measure and 0.96 for B and C measures. The average time needed to perform the measurements was of 16 h for both manual measurements, and of 3 min for the automatic method. Results demonstrate the high reliability and, most importantly, high repeatability of the proposed approach, and considerable speed-up on the planning.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background Sedation prior to performance of diagnostic esophagogastroduodenoscopy (EGDE) is widespread and increases patient comfort. But 98% of all serious adverse events during EGDEs are ascribed to sedation. The S3 guideline for sedation procedures in gastrointestinal endoscopy published in 2008 in Germany increases patient safety by standardization. These new regulations increase costs because of the need for more personnel and a prolonged discharge procedure after examinations with sedation. Many patients have difficulties to meet the discharge criteria regulated by the S3 guideline, e.g. the call for a second person to escort them home, to resign from driving and working for the rest of the day, resulting in a refusal of sedation. Therefore, we would like to examine if an acupuncture during elective, diagnostic EGDEs could increase the comfort of patients refusing systemic sedation. Methods/Design A single-center, double blinded, placebo controlled superiority trial to compare the success rates of elective, diagnostic EGDEs with real and placebo acupuncture. All patients aged 18 years or older scheduled for elective, diagnostic EGDE who refuse a systemic sedation are eligible. 354 patients will be randomized. The primary endpoint is the rate of successful EGDEs with the randomized technique. Intervention: Real or placebo acupuncture before and during EGDE. Duration of study: Approximately 24 months. Discussion Organisation/Responsibility The ACUPEND - Trial will be conducted in accordance with the protocol and in compliance with the moral, ethical, and scientific principles governing clinical research as set out in the Declaration of Helsinki (1989) and Good Clinical Practice (GCP). The Interdisciplinary Endoscopy Center (IEZ) of the University Hospital Heidelberg is responsible for design and conduct of the trial, including randomization and documentation of patients' data. Data management and statistical analysis will be performed by the independent Institute for Medical Biometry and Informatics (IMBI) and the Center of Clinical Trials (KSC) at the Department of General, Visceral and Transplantation Surgery, University of Heidelberg.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the isoflurane-sparing effects of lidocaine administered by constant rate infusion (CRI) during umbilical surgery in calves. STUDY DESIGN: Randomized 'blinded' prospective clinical study. ANIMALS: Thirty calves (mean 4.7 +/- SD 2.5 weeks old) undergoing umbilical surgery. METHODS: After premedication with xylazine (0.1 mg kg(-1) , IM), anaesthesia was induced with ketamine (4 mg kg(-1) , IV) and maintained with isoflurane in O(2) administered through a circle breathing system. The calves were assigned randomly to receive a bolus of 2 mg kg(-1) lidocaine IV after induction of anaesthesia, followed by CRI of 50 mug kg(-1) minute(-1) (group L, n=15) or a bolus and CRI of 0.9% sodium chloride (NaCl, group S, n=15). End-tidal isoflurane was adjusted to achieve adequate depth of anaesthesia. Heart rate, direct arterial blood pressure and body temperature were measured intraoperatively. Groups were compared by t- tests, anova or Mann-Whitney rank sum test as appropriate. RESULTS: The end-tidal concentration of isoflurane (median, IQR) was significantly lower in group L [1.0% (0.94-1.1)] compared to group S [1.2% (1.1-1.5)], indicating a 16.7% reduction in anaesthetic requirement during lidocaine CRI. Cardiopulmonary parameters and recovery times did not differ significantly between groups. CONCLUSION AND CLINICAL RELEVANCE: Lidocaine CRI may be used as a supplement to inhalation anaesthesia during umbilical surgery in calves in countries where such a protocol would be within the legal requirements for veterinary use in food animals. This study did not show any measurable benefit to the calves other than a reduction in isoflurane requirement.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: In contrast to hypnosis, there is no surrogate parameter for analgesia in anesthetized patients. Opioids are titrated to suppress blood pressure response to noxious stimulation. The authors evaluated a novel model predictive controller for closed-loop administration of alfentanil using mean arterial blood pressure and predicted plasma alfentanil concentration (Cp Alf) as input parameters. METHODS: The authors studied 13 healthy patients scheduled to undergo minor lumbar and cervical spine surgery. After induction with propofol, alfentanil, and mivacurium and tracheal intubation, isoflurane was titrated to maintain the Bispectral Index at 55 (+/- 5), and the alfentanil administration was switched from manual to closed-loop control. The controller adjusted the alfentanil infusion rate to maintain the mean arterial blood pressure near the set-point (70 mmHg) while minimizing the Cp Alf toward the set-point plasma alfentanil concentration (Cp Alfref) (100 ng/ml). RESULTS: Two patients were excluded because of loss of arterial pressure signal and protocol violation. The alfentanil infusion was closed-loop controlled for a mean (SD) of 98.9 (1.5)% of presurgery time and 95.5 (4.3)% of surgery time. The mean (SD) end-tidal isoflurane concentrations were 0.78 (0.1) and 0.86 (0.1) vol%, the Cp Alf values were 122 (35) and 181 (58) ng/ml, and the Bispectral Index values were 51 (9) and 52 (4) before surgery and during surgery, respectively. The mean (SD) absolute deviations of mean arterial blood pressure were 7.6 (2.6) and 10.0 (4.2) mmHg (P = 0.262), and the median performance error, median absolute performance error, and wobble were 4.2 (6.2) and 8.8 (9.4)% (P = 0.002), 7.9 (3.8) and 11.8 (6.3)% (P = 0.129), and 14.5 (8.4) and 5.7 (1.2)% (P = 0.002) before surgery and during surgery, respectively. A post hoc simulation showed that the Cp Alfref decreased the predicted Cp Alf compared with mean arterial blood pressure alone. CONCLUSION: The authors' controller has a similar set-point precision as previous hypnotic controllers and provides adequate alfentanil dosing during surgery. It may help to standardize opioid dosing in research and may be a further step toward a multiple input-multiple output controller.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: This retrospective study was conducted to determine whether a low-volume contrast medium protocol provides sufficient enhancement for 64-detector computed tomography angiography (CTA) in patients with aortoiliac aneurysms. METHODS: Evaluated were 45 consecutive patients (6 women; mean age, 72 +/- 6 years) who were referred for aortoiliac computed tomography angiography between October 2005 and January 2007. Group A (22 patients; creatinine clearance, 64.2 +/- 8.1 mL/min) received 50 mL of the contrast agent. Group B (23 patients; creatinine clearance, 89.4 +/- 7.3 mL/min) received 100 mL of the contrast agent. The injection rate was 3.5 mL/s, followed by 30 mL of saline at 3.5 mL/s. Studies were performed on the same 64-detector computed tomography scanner using a real-time bolus-tracking technique. Quantitative analysis was performed by determination of mean vascular attenuation at 10 regions of interest from the suprarenal aorta to the common femoral artery by one reader blinded to type and amount of contrast agent and compared using the Student t test. Image quality according to a 4-point scale was assessed in consensus by two readers blinded to type and amount of contrast medium and compared using the Mann-Whitney test. Multivariable adjustments were performed using ordinal regression analysis. RESULTS: Mean total attenuation did not differ significantly between both groups (196.5 +/- 33.0 Hounsfield unit [HU] in group A and 203.1 +/- 44.2 HU in group B; P = .57 by univariate and P > .05 by multivariable analysis). Accordingly, attenuation at each region of interest was not significantly different (P > .35). Image quality was excellent or good in all patients. No significant differences in visual assessment were found comparing both contrast medium protocols (P > .05 by univariate and by multivariable analysis). CONCLUSIONS: Aortoiliac aneurysm imaging can be performed with substantially reduced amounts of contrast medium using 64-detector computed tomography angiography technology.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Based on a subgroup analysis of 18-month BAsel Stent Kosten Effektivitäts Trial (BASKET) outcome data, we hypothesized that very late (> 12 months) stent thrombosis occurs predominantly after drug-eluting stent implantation in large native coronary vessel stenting. METHODS: To prove or refute this hypothesis, we set up an 11-center 4-country prospective trial of 2260 consecutive patients treated with > or = 3.0-mm stents only, randomized to receive Cypher (Johnson ; Johnson, Miami Lakes, FL), Vision (Abbott Vascular, Abbott Laboratories, IL), or Xience stents (Abbott Vascular). Only patients with left main or bypass graft disease, in-stent restenosis or stent thrombosis, in need of nonheart surgery, at increased bleeding risk, without compliance/consent are excluded. All patients are treated with dual antiplatelet therapy for 12 months. The primary end point will be cardiac death/nonfatal myocardial infarction after 24 months with further follow-up up to 5 years. RESULTS: By June 12, 229 patients (10% of the planned total) were included with a baseline risk similar to that of the same subgroup of BASKET (n = 588). CONCLUSIONS: This study will answer several important questions of contemporary stent use in patients with large native vessel stenting. The 2-year death/myocardial infarction-as well as target vessel revascularization-and bleeding rates in these patients with a first- versus second-generation drug-eluting stent should demonstrate the benefit or harm of these stents compared to cobalt-chromium bare-metal stents in this relevant, low-risk group of everyday patients. In addition, a comparison with similar BASKET patients will allow to estimate the impact of 12- versus 6-month dual antiplatelet therapy on these outcomes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: There is little evidence on differences across health care systems in choice and outcome of the treatment of chronic low back pain (CLBP) with spinal surgery and conservative treatment as the main options. At least six randomised controlled trials comparing these two options have been performed; they show conflicting results without clear-cut evidence for superior effectiveness of any of the evaluated interventions and could not address whether treatment effect varied across patient subgroups. Cost-utility analyses display inconsistent results when comparing surgical and conservative treatment of CLBP. Due to its higher feasibility, we chose to conduct a prospective observational cohort study. METHODS: This study aims to examine if1. Differences across health care systems result in different treatment outcomes of surgical and conservative treatment of CLBP2. Patient characteristics (work-related, psychological factors, etc.) and co-interventions (physiotherapy, cognitive behavioural therapy, return-to-work programs, etc.) modify the outcome of treatment for CLBP3. Cost-utility in terms of quality-adjusted life years differs between surgical and conservative treatment of CLBP.This study will recruit 1000 patients from orthopaedic spine units, rehabilitation centres, and pain clinics in Switzerland and New Zealand. Effectiveness will be measured by the Oswestry Disability Index (ODI) at baseline and after six months. The change in ODI will be the primary endpoint of this study.Multiple linear regression models will be used, with the change in ODI from baseline to six months as the dependent variable and the type of health care system, type of treatment, patient characteristics, and co-interventions as independent variables. Interactions will be incorporated between type of treatment and different co-interventions and patient characteristics. Cost-utility will be measured with an index based on EQol-5D in combination with cost data. CONCLUSION: This study will provide evidence if differences across health care systems in the outcome of treatment of CLBP exist. It will classify patients with CLBP into different clinical subgroups and help to identify specific target groups who might benefit from specific surgical or conservative interventions. Furthermore, cost-utility differences will be identified for different groups of patients with CLBP. Main results of this study should be replicated in future studies on CLBP.