993 resultados para PACEMAKER IMPLANTATION
Resumo:
Background During acute coronary syndromes patients perceive intense distress. We hypothesized that retrospective ratings of patients' MI-related fear of dying, helplessness, or pain, all assessed within the first year post-MI, are associated with poor cardiovascular outcome. Methods We studied 304 patients (61 ± 11 years, 85% men) who after a median of 52 days (range 12-365 days) after index MI retrospectively rated the level of distress in the form of fear of dying, helplessness, or pain they had perceived at the time of MI on a numeric scale ranging from 0 ("no distress") to 10 ("extreme distress"). Non-fatal hospital readmissions due to cardiovascular disease (CVD) related events (i.e., recurrent MI, elective and non-elective stent implantation, bypass surgery, pacemaker implantation, cerebrovascular incidents) were assessed at follow-up. The relative CVD event risk was computed for a (clinically meaningful) 2-point increase of distress using Cox proportional hazard models. Results During a median follow-up of 32 months (range 16-45), 45 patients (14.8%) experienced a CVD-related event requiring hospital readmission. Greater fear of dying (HR 1.21, 95% CI 1.03-1.43), helplessness (HR 1.22, 95% CI 1.04-1.44), or pain (HR 1.27, 95% CI 1.02-1.58) were significantly associated with an increased CVD risk without adjustment for covariates. A similarly increased relative risk emerged in patients with an unscheduled CVD-related hospital readmission, i.e., when excluding patients with elective stenting (fear of dying: HR 1.26, 95% CI 1.05-1.51; helplessness: 1.26, 95% CI 1.05-1.52; pain: HR 1.30, 95% CI 1.01-1.66). In the fully-adjusted models controlling for age, the number of diseased coronary vessels, hypertension, and smoking, HRs were 1.24 (95% CI 1.04-1.46) for fear of dying, 1.26 (95% CI 1.06-1.50) for helplessness, and 1.26 (95% CI 1.01-1.57) for pain. Conclusions Retrospectively perceived MI-related distress in the form of fear of dying, helplessness, or pain was associated with non-fatal cardiovascular outcome independent of other important prognostic factors.
Resumo:
Objectives Posttraumatic stress disorder (PTSD) prospectively increases the risk of incident cardiovascular disease (CVD) independent of other risk factors in otherwise healthy individuals. Between 10% and 20% of patients develop PTSD related to the traumatic experience of myocardial infarction (MI). We investigated the hypothesis that PTSD symptoms caused by MI predict adverse cardiovascular outcome. Methods We studied 297 patients (61 ± 10 years, 83% men) who self-rated PTSD symptoms attributable to a previous index MI. Non-fatal CVD-related hospital readmissions (i.e. recurrent MI, elective and non-elective intracoronary stenting, bypass surgery, pacemaker implantation, cardiac arrhythmia, cerebrovascular event) were assessed at follow-up. Cox proportional hazard models controlled for demographic factors, coronary heart disease severity, major CVD risk factors, cardiac medication, and mental health treatment. Results Forty-three patients (14.5%) experienced an adverse event during a mean follow-up of 2.8 years (range 1.3–3.8). A 10 point higher level in the PTSD symptom score (mean 8.8 ± 9.0, range 0–47) revealed a hazard ratio (HR) of 1.42 (95% CI 1.07–1.88) for a CVD-related hospital readmission in the fully adjusted model. A similarly increased risk (HR 1.45, 95% CI 1.07–1.97) emerged for patients with a major or unscheduled CVD-related readmission (i.e. when excluding patients with elective stenting). Conclusions Elevated levels of PTSD symptoms caused by MI may adversely impact non-fatal cardiovascular outcome in post-MI patients independent of other important prognostic factors. The possible importance of PTSD symptoms as a novel prognostic psychosocial risk factor in post-MI patients warrants further study.
Resumo:
QUESTIONS UNDER STUDY: Alcohol ablation (AA) of the septum has been introduced as new therapy in hypertrophic cardiomyopathy (HCM). It was feared that iatrogenic myocardial infarction due to AA may induce re-entry tachyarrhythmias and increase sudden cardiac death. METHODS AND RESULTS: Twenty-four patients (mean age 52 years) underwent successful AA. Clinical follow-up (FU) ranged from 0.3 to 0.7 years (mean 2.8). One patient died (suicide) 4 years after AA. Left ventricular (LV) outflow gradient (peak-to-peak) decreased (median) after AA from 43 (IQR 25 to 4) mmHg to 1 (IQR 0 to 12) mmHg (rest) (p <0.001) and from 130 (IQR 75 to 165) mmHg to 13 (IQR 0 to 31) mmHg (postextrasystolic) (p <0.001). Transient AV block occurred in 22% (5/24) necessitating temporary pacing. A permanent pacemaker was implanted in 4% (1/24). NYHA-class was 2.5 (IQR 2.0 to 3.0) before and 1.5 (IQR 1.3 to 2.0) (p <0.001) after AA. During FU, 2 pacemakers were implanted due to bradycardia (no AV block). A right bundle branch block was found in 13% (2/24) before and 46 % (11/24) after AA (p = 0.003). Non-sustained ventricular tachycardia (NSVT) was observed in 13% (2/16) before and 22% (5/23) (p = 0.46) after AA. Two patients required ICD implantation. CONCLUSIONS: Long-term FU is excellent in HCM after AA. The pressure gradient drops below 25 mm Hg in 95% (23/24) of all patients. Transient AV block occurs in 22% (5/24), but permanent pacemaker implantation is rarely needed (13%, 2/24). Severe NSVT occurs in 13% (2/16) before and 22% (5/23) after AA but ICD implantation is only occasionally required.
Resumo:
BACKGROUND The electrocardiographic PR interval increases with aging, differs by race, and is associated with atrial fibrillation (AF), pacemaker implantation, and all-cause mortality. We sought to determine the associations between PR interval and heart failure, AF, and mortality in a biracial cohort of older adults. METHODS AND RESULTS The Health, Aging, and Body Composition (Health ABC) Study is a prospective, biracial cohort. We used multivariable Cox proportional hazards models to examine PR interval (hazard ratios expressed per SD increase) and 10-year risks of heart failure, AF, and all-cause mortality. Multivariable models included demographic, anthropometric, and clinical variables in addition to established cardiovascular risk factors. We examined 2722 Health ABC participants (aged 74±3 years, 51.9% women, and 41% black). We did not identify significant effect modification by race for the outcomes studied. After multivariable adjustment, every SD increase (29 ms) in PR interval was associated with a 13% greater 10-year risk of heart failure (95% confidence interval, 1.02-1.25) and a 13% increased risk of incident AF (95% confidence interval, 1.04-1.23). PR interval >200 ms was associated with a 46% increased risk of incident heart failure (95% confidence interval, 1.11-1.93). PR interval was not associated with increased all-cause mortality. CONCLUSIONS We identified significant relationships of PR interval to heart failure and AF in older adults. Our findings extend prior investigations by examining PR interval and associations with adverse outcomes in a biracial cohort of older men and women.
Resumo:
Bradyarrhythmias are caused by a disturbed impulse formation in the sinus node and/or a disturbed impulse conduction and can be subclassified clinically as sinus node dysfunction, atrioventricular (AV) block, or functional bradycardia. Persistent bradycardia can be diagnosed by standard ECG. For diagnosis of intermittent bradycardia, often long-term ECG monitoring and/or additional testing is necessary. Symptomatic bradycardias are the standard indication for cardiac pacing after exclusion of reversible causes. Since sinus node dysfunction is associated with a good prognosis, pacing in this condition is only indicated in the presence of bradycardia-related symptoms. For prognostic reasons, pacemaker implantation is indicated in third degree AV block and second degree AV block Mobitz Type II, even if asymptomatic. Cardiac pacing for recurrent unpredictable neurocardiogenic syncope due to a cardioinhibitory reflex should be considered in certain circumstances. The implantation of cardiac pacemakers has been performed for more than half of a century. Due to the enormous technological progress, pacemaker implantations can nowadays be performed under local anesthesia in an outpatient setting. However, complications of pacemaker therapy are still not uncommon.
Resumo:
BACKGROUND Ventricular arrhythmias (VAs) from the left ventricular outflow tract (LVOT) region can be inaccessible for ablation because of epicardial fat or overlying coronary arteries. OBJECTIVE We describe surgical cryoablation of this type of VA. METHODS From March 2009 to 2014, 190 consecutive patients with VAs originating from the LVOT underwent ablation at our institution. Four patients (2%) underwent surgical cryoablation for highly symptomatic VAs after failing catheter ablation. RESULTS In all patients, endocardial or percutaneous epicardial mapping was consistent with origin in the LVOT. In 2 patients, the points of earliest activation during VAs were marked with a bipolar pacing lead in the overlying cardiac vein for guidance during surgery. Surgical cryoablation was successful in 3 of the 4 patients. The fourth patient subsequently had successful endocardial catheter ablation. During a mean follow-up of 22 ± 16 months (range 4-42 months), all patients showed abolition of or marked reduction in symptomatic VA. However, 1 patient subsequently required percutaneous intervention to the left anterior descending coronary artery; another developed progressive left ventricular systolic dysfunction caused by nonischemic cardiomyopathy; and a third patient underwent permanent pacemaker implantation because of complete atrioventricular block after concomitant aortic valve replacement. CONCLUSION Surgical cryoablation is an option for highly symptomatic drug-resistant VAs emanating from the LVOT region. Despite extensive preoperative mapping, the procedure is not effective for all patients, and coronary injury is a risk.
Resumo:
La sténose aortique est la cardiopathie valvulaire la plus fréquente retrouvée chez les patients agés. Suite à l’apparition des symptômes, la survie des patients diminue de façon drastique en l’absence d’un remplacement valvulaire aortique. Cependant, une proportion considérable de ces patients n’est pas opérée en raison d’un risque chirurgical élevé, l’âge étant l’une des principales raisons de refus d’un remplacement valvulaire aortique chirurgical. Ce défaut dans la prise en charge des ces patients a favorisé le développement du remplacement valvulaire aortique par cathéter où implantation valvulaire aortique par cathèter (TAVR ou TAVI), qui a représenté une révolution dans le traitement de la sténose aortique. Cette intervention est actuellement un traitement de routine chez les patients à haut risque chirurgical atteints d’une sténose aortique, même si la chirurgie cardiaque n’est pas contre-indiquée. Ces dernières années ont vu un changement de profil des candidats potentiels vers une population à plus faible risque. Cependant, plusieurs préoccupations demeurent. L’une des plus importantes est la survenue des arythmies et de troubles de conduction, notamment le bloc de branche gauche et le bloc auriculo-ventriculaire, qui sont des complications fréquemment associées au TAVR. Malgré l’évolution de la technologie et le développement de nouveaux dispositifs réduisant le taux global de complications, aucune amélioration n’a pas été intégrée pour prévenir l’apparition de telles complications. De plus, l’utilisation de certains dispositifs de nouvelle génération semble être associée à un risque accru de troubles de conduction, et par conséquent, l’incidence de ces complications pourrait augmenter dans le futur. Cependant, L’impact et l’évolution de ces complications sont inconnus. Ce travail de recherche évalue l’incidence et l’évolution des troubles de conduction suite au TAVR et l’impact des blocs de branche gauche de novo et de l’implantation d’un pacemaker sur les résultats cliniques et échocardiographiques.
Resumo:
Scopo Confrontare il trattamento transcatetere (TAVI) balloon-expandable con il trattamento chirurgico di sostituzione valvolare aortica (AVR) della stenosi valvolare aortica severa (SVAS) nella pratica clinica real world. Materiali e metodi Nel decennio 2010-2020, 1486 pazienti con SVAS isolata sono stati sottoposti a AVR (n=1049) o TAVI balloon-expandable (n=437) presso Hesperia Hospital Modena. Sono stati analizzati la Mortality nell’intera popolazione e gli episodi di ricovero cardiovascolare nei 5 anni precedenti e durante il follow-up nella popolazione residente in Emilia Romagna (n=1196) al momento della procedura (AVR n=879, TAVI balloon-expandable n=317). Risultati La popolazione TAVI è risultata mediamente più anziana di quella AVR (età media 82.2 vs. 72.7 anni) e maggiormente gravata da comorbidità. L’In-hospital mortality è stata del 1.4% nella AVR e 2.1% nella TAVI (pNS). La sopravvivenza a 5 anni è stata del 85.74% nella AVR e del 59.45% nella TAVI, con la TAVI come fattore predittivo di All-cause mortality (HR 1.44 95%CI 1.14-1.82). La riospedalizzazione per Heart Failure a 5 anni è stata del 20.6% per AVR e 51.3% per TAVI, con dialisi preoperatoria (HR 5.67 95%CI 3.06-10.49) come principale fattore predittivo. Il tasso di All Stroke a 5 anni è stato del 3.7% nella AVR e del 7.5% nella TAVI, con fibrillazione atriale preoperatoria come principale fattore predittivo (HR 1.91 95%CI 1.06-3.45). Il tasso di angioplastica coronarica percutanea (PCI) a 5 anni è stato del 3.1% sia nella AVR che nella TAVI, con previous PCI come principale fattore predittivo (HR 4.86 95%CI 2.57-9.21). L’impianto di pacemaker a 30 giorni è stato del 2.9% nella AVR e 3.4% nella TAVI (pNS). Conclusioni Nella pratica clinica real-world 2010-2020 di un centro cardiochirurgico a medio volume, la TAVI balloon-expandable ha mostrato una eccellente performance a 30 giorni in confronto con la AVR, che invece ha evidenziato una migliore performance durante follow-up.
Resumo:
Background L’incidenza di malattie valvolari aortiche è in costante aumento. La terapia definitiva è chirurgica o interventistica, determinando un evidente miglioramento della qualità di vita, a fronte di un rischio operatorio ormai estremamente basso. Le linee guida internazionali più recenti pongono in classe I entrambe le procedure nella fascia di età fra 65 e 80 anni. Materiali e metodi È stata effettuata un’analisi retrospettiva dei pazienti di età compresa fra 65 e 80 anni, sottoposti a sostituzione valvolare aortica isolata chirurgica con bioprotesi sutureless (gruppo SU-AVR), oppure trans-catetere (gruppo TAVR), presso Maria Cecilia Hospital tra gennaio 2011 e dicembre 2021. Mediante propensity score matching sono stati analizzati, nei due gruppi risultanti, gli outcomes di mortalità e complicanze intraospedaliere, a 30 giorni, ad un anno e attuariale. Risultati Sono stati inclusi nello studio 638 pazienti, di cui 338 (52.98%) nel gruppo SU-AVR e 300 (47.02%) nel gruppo TAVR. Dopo propensity score matching, sono stati ottenuti due gruppi di pazienti (124 per gruppo) senza differenze statisticamente significative nelle comorbidità preoperatorie. La mortalità a 30 giorni è risultata sovrapponibile nei 2 gruppi. Il gruppo TAVR ha mostrato un’incidenza significativamente maggiore di impianto di pacemaker definitivo e di danni vascolari maggiori, mentre il gruppo SU-AVR ha mostrato una maggior incidenza di fibrillazione atriale, di trasfusioni e di insufficienza renale. La mortalità per tutte le cause a un anno è risultata significativamente maggiore per il gruppo TAVR e il divario continua ad aumentare con il tempo. Conclusioni La sostituzione valvolare aortica trans-catetere (TAVR) mostra risultati molto buoni nel breve termine nei pazienti fra 65 e 80 anni di età. Al follow-up a medio termine, tuttavia, i risultati preliminari mostrano un miglior outcome dei pazienti sottoposti a sostituzione valvolare chirurgica, sia in termini di mortalità per qualsiasi causa che di eventi cardiovascolari e cerebrovascolari maggiori.
Resumo:
Objective: To ascertain incidence and predictors of new permanent pacemaker (PPM) following transcatheter aortic valve implantation (TAVI) with the self-expanding aortic bioprosthesis. Background: TAVI with the Medtronic Corevalve (MCV) Revalving System (Medtronic, Minneapolis, MN) has been associated with important post-procedural conduction abnormalities and frequent need for PPM. Methods: Overall, 73 consecutive patients with severe symptomatic AS underwent TAVI with the MCV at two institutions; 10 patients with previous pacemaker and 3 patients with previous aortic valve replacement were excluded for this analysis. Clinical, echocardiographic, and procedural data were collected prospectively in a dedicated database. A standard 12-lead ECG was recorded in all patients at baseline, after the procedure and predischarge. Decision to implant PPM was taken according to current guidelines. Logistic multivariable modeling was applied to identify independent predictors of PPM at discharge. Results: Patients exhibited high-risk features as evidenced by advanced age (mean = 82.1 +/- 6.2 years) and high surgical scores (logistic EuroSCORE 23.0 +/- 12.8%, STS score 9.4 +/- 6.9%). The incidence of new PPM was 28.3%. Interventricular septum thickness and logistic Euroscore were the baseline independent predictors of PPM. When procedural variables were included, the independent predictors of PPM were interventricular septum thickness (OR 0.52; 95% CI 0.320.85) and the distance between noncoronary cusp and the distal edge of the prosthesis (OR 1.37; 95% CI 1.031.83). Conclusions: Conduction abnormalities are frequently observed after TAVI with self-expandable bioprosthesis and definitive pacing is required in about a third of the patients, with a clear association with depth of implant and small interventricular septum thickness. (c) 2011 Wiley Periodicals, Inc.
Resumo:
Background-Although routinely administered, definitive evidence for the benefits of prophylactic antibiotics before the implantation of permanent pacemakers and implantable cardioverter-defibrillators from a large double-blinded placebo-controlled trial is lacking. The purpose of this study was to determine whether prophylactic antibiotic administration reduces the incidence of infection related to device implantation. Methods and Results-This double blinded study included 1000 consecutive patients who presented for primary device (Pacemaker and implantable cardioverter-defibrillators) implantation or generator replacement randomized in a 1:1 fashion to prophylactic antibiotics or placebo. Intravenous administration of I g of cefazolin (group 1) or placebo (group 2) was done immediately before the procedure. Follow-up was performed 10 days, 1, 3, and 6 months after discharge. The primary end point was any evidence of infection at the surgical incision (pulse generator pocket), or systemic infection related to be procedure. The safety committee interrupted the trial after 649 patients were enrolled due to a significant difference in favor of the antibiotic arm (group 1: 2 of 314 infected patients-0.63%; group 11: 11 of 335 to 3.28%; RR=0.19; P=0.016). The following risk factors were positively correlated with infection by univariate analysis: nonuse of preventive antibiotic (P=0.016); implant procedures (versus generator replacement: P=0.02); presence of postoperative hematoma (P=0.03) and procedure duration (P=0.009). Multivariable analysis identified nonuse of antibiotic (P=0.037) and postoperative hematoma (P=0.023) as independent predictors of infection. Conclusions-Anti biotic prophylaxis significantly reduces infectious complications in patients undergoing implantation of pacemakers or cardioverter-defibrillators. (Circ Arrhythmia Electrophysiol. 2009;2:29-34.)
Resumo:
Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular
Resumo:
Background:Isolated congenital atrioventricular block (CAVB) is a rare condition with multiple clinical outcomes. Ventricular remodeling can occur in approximately 10% of the patients after pacemaker (PM) implantation.Objectives:To assess the functional capacity of children and young adults with isolated CAVB and chronic pacing of the right ventricle (RV) and evaluate its correlation with predictors of ventricular remodeling.Methods:This cross-sectional study used a cohort of patients with isolated CAVB and RV pacing for over a year. The subjects underwent clinical and echocardiographic evaluation. Functional capacity was assessed using the six-minute walk test. Chi-square test, Fisher's exact test, and Pearson correlation coefficient were used, considering a significance level of 5%.Results:A total of 61 individuals were evaluated between March 2010 and December 2013, of which 67.2% were women, aged between 7 and 41 years, who were using PMs for 13.5 ± 6.3 years. The percentage of ventricular pacing was 97.9 ± 4.1%, and the duration of the paced QRS complex was 153.7 ± 19.1 ms. Majority of the subjects (95.1%) were asymptomatic and did not use any medication. The mean distance walked was 546.9 ± 76.2 meters and was strongly correlated with the predicted distance (r = 0.907, p = 0.001) but not with risk factors for ventricular remodeling. (Arq Bras Cardiol. 2014; [online].ahead print, PP.0-0)Conclusions:The functional capacity of isolated CAVB patients with chronic RV pacing was satisfactory but did not correlate with risk factors for ventricular remodeling.
Resumo:
BACKGROUND: New generation transcatheter heart valves (THV) may improve clinical outcomes of transcatheter aortic valve implantation. METHODS AND RESULTS: In a nationwide, prospective, multicenter cohort study (Swiss Transcatheter Aortic Valve Implantation Registry, NCT01368250), outcomes of consecutive transfemoral transcatheter aortic valve implantation patients treated with the Sapien 3 THV (S3) versus the Sapien XT THV (XT) were investigated. An overall of 153 consecutive S3 patients were compared with 445 consecutive XT patients. Postprocedural mean transprosthetic gradient (6.5±3.0 versus 7.8±6.3 mm Hg, P=0.17) did not differ between S3 and XT patients, respectively. The rate of more than mild paravalvular regurgitation (1.3% versus 5.3%, P=0.04) and of vascular (5.3% versus 16.9%, P<0.01) complications were significantly lower in S3 patients. A higher rate of new permanent pacemaker implantations was observed in patients receiving the S3 valve (17.0% versus 11.0%, P=0.01). There were no significant differences for disabling stroke (S3 1.3% versus XT 3.1%, P=0.29) and all-cause mortality (S3 3.3% versus XT 4.5%, P=0.27). CONCLUSIONS: The use of the new generation S3 balloon-expandable THV reduced the risk of more than mild paravalvular regurgitation and vascular complications but was associated with an increased permanent pacemaker rate compared with the XT. Transcatheter aortic valve implantation using the newest generation balloon-expandable THV is associated with a low risk of stroke and favorable clinical outcomes. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT01368250.