995 resultados para Orthopedic fixation devices


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper aims to review biomaterials used in manufacturing bone plates including advances in recent years and prospect in the future. It has found among all biomaterials, currently titanium and stainless steel alloys are the most common in production of bone plates. Other biomaterials such as Mg alloys, Ta alloys, SMAs, carbon fiber composites and bioceramics are potentially suitable for bone plates because of their advantages in biocompatibility, bioactivity and biodegradability. However, today either they are not used in bone plates or have limited applications in only some flexible small-size implants. This problem is mainly related to their poor mechanical properties. Additionally, production processes play an effective role. Therefore, in the future, further studies should be conducted to solve these problems and make them feasible for heavy-duty bone plates.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Cardiovascular diseases are a leading cause of death throughout the developed world. With the demand for donor hearts far exceeding the supply, a bridge-to-transplant or permanent solution is required. This is currently achieved with ventricular assist devices (VADs), which can be used to assist the left ventricle (LVAD), right ventricle (RVAD), or both ventricles simultaneously (BiVAD). Earlier generation VADs were large, volume-displacement devices designed for temporary support until a donor heart was found. The latest generation of VADs use rotary blood pump technology which improves device lifetime and the quality of life for end stage heart failure patients. VADs are connected to the heart and greater vessels of the patient through specially designed tubes called cannulae. The inflow cannulae, which supply blood to the VAD, are usually attached to the left atrium or ventricle for LVAD support, and the right atrium or ventricle for RVAD support. Few studies have characterized the haemodynamic difference between the two cannulation sites, particularly with respect to rotary RVAD support. Inflow cannulae are usually made of metal or a semi-rigid polymer to prevent collapse with negative pressures. However suction, and subsequent collapse, of the cannulated heart chamber can be a frequent occurrence, particularly with the relatively preload insensitive rotary blood pumps. Suction events may be associated with endocardial damage, pump flow stoppages and ventricular arrhythmias. While several VAD control strategies are under development, these usually rely on potentially inaccurate sensors or somewhat unreliable inferred data to estimate preload. Fixation of the inflow cannula is usually achieved through suturing the cannula, often via a felt sewing ring, to the cannulated chamber. This technique extends the time on cardiopulmonary bypass which is associated with several postoperative complications. The overall objective of this thesis was to improve the placement and design of rotary LVAD and RVAD inflow cannulae to achieve enhanced haemodynamic performance, reduced incidence of suction events, reduced levels of postoperative bleeding and a faster implantation procedure. Specific objectives were: * in-vitro evaluation of LVAD and RVAD inflow cannula placement, * design and in-vitro evaluation of a passive mechanism to reduce the potential for heart chamber suction, * design and in-vitro evaluation of a novel suture-less cannula fixation device. In order to complete in-vitro evaluation of VAD inflow cannulae, a mock circulation loop (MCL) was developed to accurately replicate the haemodynamics in the human systemic and pulmonary circulations. Validation of the MCL’s haemodynamic performance, including the form and magnitude of pressure, flow and volume traces was completed through comparisons of patient data and the literature. The MCL was capable of reproducing almost any healthy or pathological condition, and provided a useful tool to evaluate VAD cannulation and other cardiovascular devices. The MCL was used to evaluate inflow cannula placement for rotary VAD support. Left and right atrial and ventricular cannulation sites were evaluated under conditions of mild and severe heart failure. With a view to long term LVAD support in the severe left heart failure condition, left ventricular inflow cannulation was preferred due to improved LVAD efficiency and reduced potential for thrombus formation. In the mild left heart failure condition, left atrial cannulation was preferred to provide an improved platform for myocardial recovery. Similar trends were observed with RVAD support, however to a lesser degree due to a smaller difference in right atrial and ventricular pressures. A compliant inflow cannula to prevent suction events was then developed and evaluated in the MCL. As rotary LVAD or RVAD preload was reduced, suction events occurred in all instances with a rigid inflow cannula. Addition of the compliant segment eliminated suction events in all instances. This was due to passive restriction of the compliant segment as preload dropped, thus increasing the VAD circuit resistance and decreasing the VAD flow rate. Therefore, the compliant inflow cannula acted as a passive flow control / anti-suction system in LVAD and RVAD support. A novel suture-less inflow cannula fixation device was then developed to reduce implantation time and postoperative bleeding. The fixation device was evaluated for LVAD and RVAD support in cadaveric animal and human hearts attached to a MCL. LVAD inflow cannulation was achieved in under two minutes with the suture-less fixation device. No leakage through the suture-less fixation device – myocardial interface was noted. Continued development and in-vivo evaluation of this device may result in an improved inflow cannulation technique with the potential for off-bypass insertion. Continued development of this research, in particular the compliant inflow cannula and suture-less inflow cannulation device, will result in improved postoperative outcomes, life span and quality of life for end-stage heart failure patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper proposes a new iterative method to achieve an optimally fitting plate for preoperative planning purposes. The proposed method involves integration of four commercially available software tools, Matlab, Rapidform2006, SolidWorks and ANSYS, each performing specific tasks to obtain a plate shape that fits optimally for an individual tibia and is mechanically safe. A typical challenge when crossing multiple platforms is to ensure correct data transfer. We present an example of the implementation of the proposed method to demonstrate successful data transfer between the four platforms and the feasibility of the method.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Studies on quantitative fit analysis of precontoured fracture fixation plates emerged within the last few years and therefore, there is a wide research gap in this area. Quantitative fit assessment facilitates the measure of the gap between a fracture fixation plate and the underlying bone, and specifies the required plate fit criteria. For clinically meaningful fit assessment outcome, it is necessary to establish the appropriate criteria and parameter. The present paper studies this subject and recommends using multiple fit criteria and the maximum distance between the plate and underlying bone as fit parameter for clinically relevant outcome. We also propose the development of a software tool for automatic plate positioning and fit assessment for the purpose of implant design validation and optimization in an effort to provide better fitting implant that can assist proper fracture healing. The fundamental specifications of the software are discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Oral endotracheal tubes (ETTs) and nasogastric tubes (NGT) are common devices used in adult intensive care and numerous options exist for safe and comfortable securement of these devices. The aim of this project was to identify the available range of ETT and NGT securement devices in Australia as a resource for clinicians seeking to explore options for tube stabilisation. This article reports part A of this project: ETT securement options. Part B will report NGT device fixation options. Securing ETTs to ensure a patent airway with minimal ETT movement, promotion of patient comfort and absence of adverse events such as ETT dislodgement, unplanned extubation and device-related injury1, are essential critical care nursing actions. The ETT requires a fixation method that is robust yet does not traumatise or injure the mucosal tissues of the mouth and soft tissue of the lips.2,3 Choice of a securement apparatus is often determined by product availability in our units or hospitals but is also driven by evidence-based practice and clinician preference. Trying to put this information together can be difficult and time-consuming for the bedside clinician...

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Anatomically pre-contoured fracture fixation plates are a treatment option for bone fractures. A well-fitting plate can be used as a tool for anatomical reduction of the fractured bone. However, recent studies showed that some plates fit poorly for many patients due to considerable shape variations between bones of the same anatomical site. Therefore, the plates have to be manually fitted and deformed by surgeons to fit each patient optimally. The process is time-intensive and labor-intensive, and could lead to adverse clinical implications such as wound infection or plate failure. This paper proposes a new iterative method to simulate the patient-specific deformation of an optimally fitting plate for pre-operative planning purposes. We further demonstrate the validation of the method through a case study. The proposed method involves the integration of four commercially available software tools, Matlab, Rapidform2006, SolidWorks, and ANSYS, each performing specific tasks to obtain a plate shape that fits optimally for an individual tibia and is mechanically safe. A typical challenge when crossing multiple platforms is to ensure correct data transfer. We present an example of the implementation of the proposed method to demonstrate successful data transfer between the four platforms and the feasibility of the method.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The goal of this study was to investigate the use of custom-made orthopedic shoes (OS) and the association between the use of OS and the most relevant aspects of their usability. Over a 6-month period, patients meeting the inclusion criteria were recruited by 12 orthopedic shoe companies scattered throughout the Netherlands and asked to complete a questionnaire composed of a pre- and post-OS section. Patients with different pathologies were included in the study (n = 339; response 67%). Mean age of the patients was 63 +/- 15 years, and 38% were male. Three months after delivery, 81% of the patients used their OS frequently (4-7 days/week), 13% occasionally (1-3 days/week), and 6% did not use their OS. Associations were found between use and all measured aspects of usability (p-values varied from <0.001 to 0.028). Patients who used their OS more often had a more positive opinion regarding all the aspects of usability. We conclude that all aspects of the usability of OS are relevant in relation to their use and should be taken into account when prescribing and evaluating OS.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study investigated long-term use of custom-made orthopedic shoes (OS) at 1.5 years follow-up. In addition, the association between short-term outcomes and long-term use was studied. Patients from a previously published study who did use their first-ever pair of OS 3 months after delivery received another questionnaire after 1.5 years. Patients with different pathologies were included in the study (n = 269, response = 86%). Mean age was 63 ± 14 years, and 38% were male. After 1.5 years, 87% of the patients still used their OS (78% frequently [4-7 days/week] and 90% occasionally [1-3 days/week]) and 13% of the patients had ceased using their OS. Patients who were using their OS frequently after 1.5 years had significantly higher scores for 8 of 10 short-term usability outcomes (p-values ranged from <0.001 to 0.046). The largest differences between users and nonusers were found for scores on the short-term outcomes of OS fit and communication with the medical specialist and shoe technician (effect size range = 0.16 to 0.46). We conclude that patients with worse short-term usability outcomes for their OS are more likely to use their OS only occasionally or not at all at long-term follow-up.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Toward preparing strong multi-biofunctional materials, poly(ethylenimine) (PEI) conjugated graphene oxide (GO_PEI) was synthesized using poly(acrylic acid) (PAA) as a spacer and incorporated in poly( e-caprolactone) (PCL) at different fractions. GO_PEI significantly promoted the proliferation and formation of focal adhesions in human mesenchymal stem cells (hMSCs) on PCL. GO_PEI was highly potent in inducing stem cell osteogenesis leading to near doubling of alkaline phosphatase expression and mineralization over neat PCL with 5% filler content and was approximate to 50% better than GO. Remarkably, 5% GO_ PEI was as potent as soluble osteoinductive factors. Increased adsorption of osteogenic factors due to the amine and oxygen containing functional groups on GO_ PEI augment stem cell differentiation. GO_ PEI was also highly efficient in imparting bactericidal activity with 85% reduction in counts of E. coli colonies compared to neat PCL at 5% filler content and was more than twice as efficient as GO. This may be attributed to the synergistic effect of the sharp edges of the particles along with the presence of the different chemical moieties. Thus, GO_ PEI based polymer composites can be utilized to prepare bioactive resorbable biomaterials as an alternative to using labile biomolecules for fabricating orthopedic devices for fracture fixation and tissue engineering.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introducción: Las fracturas intertrocantéricas han llegado a nuestros días con una mayor incidencia dado el envejecimiento de la población, con fracturas más complejas, menos estables y asociadas a osteoporosis, se estima que representan aproximadamente 1,75 millones de años de vida perdidos ajustados a discapacidad es decir 0,1% de la carga de morbilidad a nivel mundial. Existe consenso en el tratamiento quirúrgico de este tipo de fracturas, presentando una incidencia variable de fallos, principalmente cuando son inestables, entre estos el denominado “cuto ut”. La utilización de un método de fijación con placa y tornillo helicoidal (DHHS) aparentemente disminuye la incidencia de dichos fallos con respecto a otras técnicas. Metodología: Por medio de una muestra calculada en 128 de pacientes con fracturas intertrocantéricas operados con DHS y DHHS entre el 2007 y el 2012 en La Clínica San Rafael de la ciudad de Bogotá, Colombia, se realizó un análisis multivariado para determinar si existe o no diferencias significativas en los índices de fallo entre estas dos técnicas. Resultados: Los pacientes incluidos en el estudio 54 (42,1%) fueron hombres y 74 (57,8%) fueron mujeres. 75 fueron operados con DHHS y 53 con DHS; en cuanto a las comorbilidades las principales fueron Hipertensión con 40 pacientes para DHS y 30 para DHHS, para el caso de Diabetes Mellitus fueron 13 y 9 para DHS y DHHS, respectivamente; en cuanto al tipo de fractura más común la principal fue la clasificación Tronzo II con 9 pacientes para DHS y 13 para DHHS. Conclusión. Para el estudios se evidencia que para los 3 desenlaces principales evaluados, 1. El porcentaje de re intervención (p=0,282), 2. La supervivencia en el primer año (p=0,499) y 3. El desempeño funcional con la escala de Oxford (p=0,06); no hubo diferencias estadísticamente significativas entre los grupos.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Previous studies have pointed out that the mere elevation of the maxillary sinus membrane promotes bone formation without the use of augmentation materials. Purpose: This experimental study aimed at evaluating if the two-stage procedure for sinus floor augmentation could benefit from the use of a space-making device in order to increase the bone volume to enable later implant installation with good primary stability. Materials and Methods: Six male tufted capuchin primates (Cebus apella) were subjected to extraction of the three premolars and the first molar on both sides of the maxilla to create an edentulous area. The sinuses were opened using the lateral bone-wall window technique, and the membrane was elevated. One resorbable space-making device was inserted in each maxillary sinus, and the bone window was returned in place. The animals were euthanatized after 6 months, and biopsy blocks containing the whole maxillary sinus and surrounding soft tissues were prepared for ground sections. Results: The histological examination of the specimens showed bone formation in contact with both the schneiderian membrane and the device in most cases even when the device was displaced. The process of bone formation indicates that this technique is potentially useful for two-stage sinus floor augmentation. The lack of stabilization of the device within the sinus demands further improvement of space-makers for predictable bone augmentation. Conclusions: It is concluded that (1) the device used in this study did not trigger any important inflammatory reaction; (2) when the sinus membrane was elevated, bone formation was a constant finding; and (3) an ideal space-making device should be stable and elevate the membrane to ensure a maintained connection between the membrane and the secluded space.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Delayed fracture healing and non-unions represent rare but severe complications in orthopedic surgery. Further knowledge on the mechanisms of the bone repair process and of the development of a pseudoarthrosis is essential to predict and prevent impaired healing of fractures. The present study aimed at elucidating differences in gene expression during the repair of rigidly and non-rigidly fixed osteotomies. For this purpose, the MouseFix™ and the FlexiPlate™ systems (AO Development Institute, Davos, CH), allowing the creation of well defined osteotomies in mouse femora, were employed. A time course following the healing process of the osteotomy was performed and bones and periimplant tissues were analyzed by high-resolution X-ray, MicroCT and by histology. For the assessment of gene expression, Low Density Arrays (LDA) were done. In animals with rigid fixation, X-ray and MicroCT revealed healing of the osteotomy within 3 weeks. Using the FlexiPlate™ system, the osteotomy was still visible by X-ray after 3 weeks and a stabilizing cartilaginous callus was formed. After 4.5 weeks, the callus was remodeled and the osteotomy was, on a histological level, healed. Gene expression studies revealed levels of transcripts encoding proteins associated with inflammatory processes not to be altered in tissues from bones with rigid and non-rigid fixation, respectively. Levels of transcripts encoding proteins of the extracellular matrix and essential for bone cell functions were not increased in the rigidly fixed group when compared to controls without osteotomy. In the FlexiPlate™ group, levels of transcripts encoding the same set of genes were significantly increased 3 weeks after surgery. Expression of transcripts encoding BMPs and BMP antagonists was increased after 3 weeks in repair tissues from bones fixed with FlexiPlate™, as were inhibitors of the WNT signaling pathways. Little changes only were detected in transcript levels of tissues from rigidly fixed bones. The data of the present study suggest that rigid fixation enables accelerated healing of an experimental osteotomy as compared to non-rigid fixation. The changes in the healing process after non-rigid fixation are accompanied by an increase in the levels of transcripts encoding inhibitors of osteogenic pathways and, probably as a consequence, by temporal changes in bone matrix synthesis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To evaluate selective and superselective catheter therapy of serious arterial damage associated with orthopedic surgery of the pelvis, hip joint, femur, and knee. MATERIALS AND METHODS: Between 1989 and 2005, 16 consecutive patients with arterial damage after orthopedic surgery (seven women, nine men; mean age, 62 years; age range, 21-82 y) underwent angiographic exploration. Seven patients were in hemodynamically unstable condition. Initial orthopedic procedures were iliac crest internal fixation (n = 1); total hip prosthesis (n = 3); revision of total hip prosthesis (n = 4); revision of acetabular cup prosthesis (n = 1); gamma-nailing, nail-plate fixation, or intramedullary nailing (n = 3); and total knee prosthesis (n = 4). RESULTS: Angiography showed pseudoaneurysms (n = 11), vascular lacerations with active extravasation (n = 3), and arteriovenous fistulas with extravasation (n = 2). After angiographic documentation of serious arterial injury, 14 patients were treated with a single or coaxial catheter technique in combination with coils alone, coils and polyvinyl alcohol particles, coils and Gelfoam pledgets, or Gelfoam pledgets; or balloon occlusion with isobutyl cyanoacrylate and coils. Two patients were treated with covered stents. In all, bleeding was effectively controlled in a single session in 16 patients, with immediate circulatory stabilization. Major complications included death, pulmonary embolism, and postprocedural hematoma. CONCLUSION: Selective and superselective catheter therapy may be used for effective, minimally invasive management of rare but potentially life-threatening vascular complications after orthopedic surgery.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pedicle hooks which are used as an anchorage for posterior spinal instrumentation may be subjected to considerable three-dimensional forces. In order to achieve stronger attachment to the implantation site, hooks using screws for additional fixation have been developed. The failure loads and mechanisms of three such devices have been experimentally determined on human thoracic vertebrae: the Universal Spine System (USS) pedicle hook with one screw, a prototype pedicle hook with two screws and the Cotrel-Dubousset (CD) pedicle hook with screw. The USS hooks use 3.2-mm self-tapping fixation screws which pass into the pedicle, whereas the CD hook is stabilised with a 3-mm set screw pressing against the superior part of the facet joint. A clinically established 5-mm pedicle screw was tested for comparison. A matched pair experimental design was implemented to evaluate these implants in constrained (series I) and rotationally unconstrained (series II) posterior pull-out tests. In the constrained tests the pedicle screw was the strongest implant, with an average pull-out force of 1650 N (SD 623 N). The prototype hook was comparable, with an average failure load of 1530 N (SD 414 N). The average pull-out force of the USS hook with one screw was 910 N (SD 243 N), not significantly different to the CD hook's average failure load of 740 N (SD 189 N). The result of the unconstrained tests were similar, with the prototype hook being the strongest device (average 1617 N, SD 652 N). However, in this series the difference in failure load between the USS hook with one screw and the CD hook was significant. Average failure loads of 792 N (SD 184 N) for the USS hook and 464 N (SD 279 N) for the CD hook were measured. A pedicular fracture in the plane of the fixation screw was the most common failure mode for USS hooks.(ABSTRACT TRUNCATED AT 250 WORDS)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND CONTEXT: Closed reduction and internal fixation by an anterior approach is an established option for operative treatment of displaced Type II odontoid fractures. In elderly patients, however, inadequate screw purchase in osteoporotic bone can result in severe procedure-related complications. PURPOSE: To improve the stability of odontoid fracture screw fixation in the elderly using a new technique that includes injection of polymethylmethacrylat (PMMA) cement into the C2 body. STUDY DESIGN: Retrospective review of hospital and outpatient records as well as radiographs of elderly patients treated in a university hospital department of orthopedic surgery. PATIENT SAMPLE: Twenty-four elderly patients (8 males and 16 females; mean age, 81 years; range, 62-98 years) with Type II fractures of the dens. OUTCOME MEASURES: Complications, cement leakage (symptomatic/asymptomatic), operation time, loss of reduction, pseudarthrosis and revision surgery, patient complaints, return to normal activities, and signs of neurologic complications were all documented. METHODS: After closed reduction and anterior approach to the inferior border of C2, a guide wire is advanced to the tip of the odontoid under biplanar fluoroscopic control. Before the insertion of one cannulated, self-drilling, short thread screws, a 12 gauge Yamshidi cannula is inserted from anterior and 1 to 3 mL of high-viscosity PMMA cement is injected into the anteroinferior portion of the C2 body. During polymerization of the cement, the screws are further inserted using a lag-screw compression technique. The cervical spine then is immobilized with a soft collar for 8 weeks postoperatively. RESULTS: Anatomical reduction of the dens was achieved in all 24 patients. Mean operative time was 64 minutes (40-90 minutes). Early loss of reduction occurred in three patients, but revision surgery was indicated in only one patient 2 days after primary surgery. One patient died within the first eight postoperative weeks, one within 3 months after surgery. In five patients, asymptomatic cement leakage was observed (into the C1-C2 joint in three patients, into the fracture in two). Conventional radiologic follow-up at 2 and 6 months confirmed anatomical healing in 16 of the19 patients with complete follow-up. In two patients, the fractures healed in slight dorsal angulation; one patient developed a asymptomatic pseudarthrosis. All patients were able to resume their pretrauma level of activity. CONCLUSIONS: Cement augmentation of the screw in Type II odontoid fractures in elderly patients is technically feasible in a clinical setting with a low complication rate. This technique may improve screw purchase, especially in the osteoporotic C2 body.