887 resultados para Orthodontic


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To evaluate the shear bond strength and site of failure of brackets bonded to dry and wet enamel. Study design: 50 teeth were divided into ten groups of 5 teeth each (10 surfaces). In half the groups enamel was kept dry before bonding, and in the other half distilled water was applied to wet the surface after etching. The following groups were established: 1)Acid/Transbond-XT (dry/wet) XT; 2) Transbond Plus Self Etching Primer (TSEP)/Transbond-XT paste (dry/wet); 3) Concise (dry), Transbond MIP/Concise (wet), 4) FujiOrtho-LC (dry/wet); 5) SmartBond (dry/wet). Brackets were bonded to both buccal and lingual surfaces. Specimens were stored in distilled water (24 hours at 37ºC) and thermocycled. Brackets were debonded using a Universal testing machine (cross-head speed 1 mm/min). Failure sites were classified using a stereomicroscope. Results: No significant differences in bond strength were detected between the adhesives under wet and dry conditions except for Smart- Bond, whose bond strength was significantly lower under dry conditions. For all the adhesives most bond failures were of mixed site location except for Smartbond, which failed at the adhesive-bracket interface. Conclusions: Under wet conditions the bonding capacity of the adhesives tested was similar than under dry conditions, with the exception of SmartBond which improved under wet conditions

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The goal of the study was to analyse orthodontic care in Finnish health centres with special reference to the delivery, outcome and costs of treatment. Public orthodontic care was studied by two questionnaires sent to the chief dental officers of all health centres (n = 276) and to all specialist orthodontists in Finland (n = 146). The large regional variation was mentioned by the orthodontists as the most important factor requiring improvement. Orthodontic practices and outcome were studied in eight Finnish municipal health centres representing early and late timing of treatment. A random sample of 16- and 18-year-olds (n = 1109) living in these municipalities was examined for acceptability of occlusion with the Occlusal Morphology and Function Index (OMFI). In acceptability of occlusion, only minor differences were found between the two timing groups. The percentage of subjects with acceptable morphology was higher among untreated than among treated adolescents. The costs of orthodontic care were estimated among the adolescents with a treatment history. The mean appliance costs were higher in the late, and the mean visit costs higher in the early timing group. The cost-effectiveness of orthodontic services differed among the health centres, but was almost equal in the two timing groups. National guidelines and delegation of orthodontic tasks were suggested as the tools for reducing the variation among the health centres. In the eight health centres, considerable variation was found in acceptability of occlusion and in cost-effectiveness of services. The cost-effectiveness was not directly connected with the timing of treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Les troubles respiratoires du sommeil (TRS), qui représentent une préoccupation croissante pour la santé, ont des effets significatifs sur la santé, le comportement et la performance académique chez l’enfant. Les malformations craniofaciales, l’hypertrophie adéno-amygdalienne et l'obésité, représentent des facteurs de risque importants dans le développement de cette condition. Les symptômes des TRS ont été étudiés dans une étude prospective chez les enfants et adolescents durant leur traitement orthodontique dans un milieu universitaire. Cette étude a cherché à décrire la prévalence et les facteurs de risque principaux des TRS, ainsi que l'impact des différentes interventions orthodontiques sur les symptômes TRS. Matériel et méthodes: dans une étude cohorte prospective, un groupe de 168 sujets âgés de 12 à 21 ans ont été soumis, quatre ans après la prise de données initiale, à un examen craniofacial en plus d'être administré des questionnaires qui ont recueilli des données sur la situation socio-démographique, le bruxisme et les troubles d’ATM, le sommeil et le comportement diurne, et les facteurs neuropsychologiques. Résultats: l'indice de masse corporelle a été augmenté mais est demeurée dans la même catégorie aux deux moments de l'enquête. Il ya eu une augmentation du serrement des dents et des symptômes de l'ATM, une diminution de la taille des amygdales, et une augmentation de la somnolence diurne. La prévalence des TRS n'a pas changé entre l’étude initiale et l’étude de suivi. Aucune intervention orthodontique s'est avérée avoir un effet cliniquement significatif sur les voies aériennes supérieures. Conclusions: la prévalence des symptômes TRS était constante par rapport aux valeurs de base pour la population étudiée, mais a augmenté si rapportée à la population générale. Les traitements orthodontiques ne montrent aucun effet sur les TRS. Mots-clés : apnée du sommeil, craniofacial, prévalence, ronflement, traitement orthodontique, voies aériennes supérieures

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mémoire numérisé par la Division de la gestion de documents et des archives de l'Université de Montréal

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: L’expansion palatine du maxillaire a beaucoup d’effets positifs sur la respiration et la qualité du sommeil, mais peu d'études ont examiné ces données sur des adultes ayant dépassé l’âge permettant de bénéficier d'une expansion palatine conventionnelle. Le but de cette recherche est d’évaluer la stabilité de l’EPRAC (expansion palatine rapide assistée chirurgicalement) et son effet sur les troubles respiratoires après l’ablation des appareils orthodontiques. Méthodes: Neuf patients (Âge moyen 21, entre 16-39 ans) nécessitant une EPRAC ont passé des nuits dans un laboratoire de sommeil, et ce avant l’EPRAC, après l’EPRAC, et après l’ablation des appareils fixes. Les radiographies céphalométriques postéroantérieures ainsi que les modèles d’étude ont été pris pendant ces trois périodes de temps. Résultats: L’analyse des modèles d’étude a démontré une récidive significative au niveau des distances inter-molaires et inter-canines au niveau du maxillaire seulement. Les analyses céphalométriques ont démontré une récidive au niveau de la largeur maxillaire. Aucun changement important n'a été observé dans les stades de sommeil, mais une réduction importante dans l’index de ronflement a été notée. De plus, il y avait moins de changements entre les stades de sommeil. Conclusions: La récidive squelettique est minime et cliniquement non significative. Par contre, les changements dans les distances intermolaires et intercanines sont cliniquement importants. Il semble également qu'une EPRAC ait un effet positif sur la qualité de sommeil par la réduction de l’indice de ronflement ainsi que sur la diminution des changements entre les stades de sommeil.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction : La force d’adhésion à l'interface métal-céramique avec les résines auto-polymérisantes destinées au collage indirect des boîtiers orthodontiques n'a pas été évaluée à ce jour et un protocole clinique basé sur la littérature scientifique est inexistant. Objectifs : 1) Comparer la force de cisaillement maximale entre des boîtiers métalliques et des surfaces en porcelaine préparées selon différentes méthodes; 2) Suggérer un protocole clinique efficace et prévisible. Matériel et méthodes : Quatre-vingt-dix disques en leucite (6 groupes; n = 15/groupe) ont été préparés selon 6 combinaisons de traitements de surface : mécaniques (+ / - fraisage pour créer les rugosités) et chimiques (acide fluorhydrique, apprêt, silane). Des bases en résine composite Transbond XT (3M Unitek, Monrovia, California) faites sur mesure ont été collées avec le système de résine adhésive auto-polymérisante Sondhi A + B Rapid Set (3M Unitek, Monrovia, California). Les échantillons ont été préservés (H2O/24hrs), thermocyclés (500 cycles) et testés en cisaillement (Instron, Norwood, Massachusetts). Des mesures d’Index d’adhésif résiduel (IAR) ont été compilées. Des tests ANOVAs ont été réalisés sur les rangs étant donné que les données suivaient une distribution anormale et ont été ajustés selon Tukey. Un Kruskall-Wallis, U-Mann Whitney par comparaison pairée et une analyse de Weibull ont aussi été réalisés. Résultats : Les médianes des groupes varient entre 17.0 MPa (- fraisage + acide fluorhydrique) à 26.7 MPa (- fraisage + acide fluorhydrique + silane). Le fraisage en surface ne semble pas affecter l’adhésion. La combinaison chimique (- fraisage + silane + apprêt) a démontré des forces de cisaillement significativement plus élevées que le traitement avec (- fraisage + acide fluorhydrique), p<0,05, tout en possédant des forces similaires au protocole typiquement suggéré à l’acide fluorhydrique suivi d’une application de silane, l’équivalence de (- fraisage + acide fluorhydrique + silane). Les mesures d’IAR sont significativement plus basses dans le groupe (- fraisage + acide fluorhydrique) en comparaison avec celles des 5 autres groupes, avec p<0,05. Malheureusement, ces 5 groupes ont des taux de fracture élévés de 80 à 100% suite à la décimentation des boîtiers. Conclusion : Toutes les combinaisons de traitement de surface testées offrent une force d’adhésion cliniquement suffisante pour accomplir les mouvements dentaires en orthodontie. Une application de silane suivie d’un apprêt est forte intéressante, car elle est simple à appliquer cliniquement tout en permettant une excellente adhésion. Il faut cependant avertir les patients qu’il y a un risque de fracture des restorations en céramique lorsque vient le moment d’enlever les broches. Si la priorité est de diminuer le risque d’endommager la porcelaine, un mordançage seul à l’acide hydrofluorique sera suffisant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thesis written in co-mentorship with director: Nelly Huynh; co-directors: Frank Rauch and Jean-Marc Retrouvey; collaborators: Clarice Nishio, Duy-Dat Vu and Nathalie Alos

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Orthodontic tooth movement uses mechanical forces that result in inflammation in the first days. Myeloperoxidase (MPO) is an enzyme found in polymorphonuclear neutrophil (PMN) granules, and it is used to estimate the number of PMN granules in tissues. So far, MPO has not been used to study the inflammatory alterations after the application of orthodontic tooth movement forces. The aim of this study was to determine MPO activity in the gingival crevicular fluid (GCF) and saliva (whole stimulated saliva) of orthodontic patients at different time points after fixed appliance activation. Methods: MPO was determined in the GCF and collected by means of periopaper from the saliva of 14 patients with orthodontic fixed appliances. GCF and saliva samples were collected at baseline, 2 hours, and 7 and 14 days after application of the orthodontic force. Results: Mean MPO activity was increased in both the GCF and saliva of orthodontic patients at 2 hours after appliance activation (P<0.02 for all comparisons). At 2 hours, PMN infiltration into the periodontal ligament from the orthodontic force probably results in the increased MPO level observed at this time point. Conclusions: MPO might be a good marker to assess inflammation in orthodontic movement; it deserves further studies in orthodontic therapy. (Am J Orthod Dentofacial Orthop 2010;138:613-6)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work was to investigate the neuromuscular changes associated with the orthodontic post-treatment using surface electromyography. One hundred (100) young, healthy adults without signs and symptoms of temporomandibular dysfunction (TMD) were divided into two groups: 60 subjects who were undergoing orthodontic intervention (Ortho Group) and 40 subjects who had no orthodontic intervention (Control Group), aged 18-25 years. EMG activity of masseter and temporalis anterior muscle was recorded during two different tests: 1. maximum voluntary clench (MVC) with cotton rolls; and 2. MVC in intercuspal position. In all subjects, both tests were performed with symmetric muscular patterns (more than 85%) and with insignificant latero-deviating of the mandible (lower than 10%). There are no statistically significant differences between the subjects of both groups evaluated. Both groups showed medium index values calculated according to the normal standards established previously.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to evaluate the stress distribution in the resin in contact with the spirals of cylindrical and conical mini-implants, when submitted to lateral load and insertion torsion. A photoelastic model was fabricated using transparent gelatin to simulate the alveolar bone. The model was observed with a plane polariscope and photographically recorded before and after activation of the two screws with a lateral force and torsion. The lateral force application caused bending moments on both mini-implants, with the uprising of fringes or isochromatics, characteristics of stresses, along the threads of the mini-implants and in the apex. When the torsion was exerted in the mini-implants, a great concentration of stress upraised close to the apex. The conclusion was that, comparing conical with cylindrical mini-implants under lateral load, the stresses were similar on the traction sides. The differences appear (1) on the apex, where the cylindrical mini-implant showed a greater concentration of stress, and (2) along the spirals, in the compression side, where the conical mini-implant showed a greater concentration of stress. The greater part of the stress produced by both mini-implants, after torsion load in insertion, were concentrated on the apex. With the cylindrical mini-implant, the greater concentration of tension was close to the apex, while with the conical one, the stresses were distributed along a greater amount of apical threads.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have investigated if a new LEDs system has enough efficient energy to promote efficient shear and tensile bonding strength resistance under standardized tests. LEDs 470 +/- 10 nm can be used to photocure composite during bracket fixation. Advantages considering resistance to tensile and shear bonding strength when these systems were used are necessary to justify their clinical use. Forty eight human extracted premolars teeth and two light sources were selected, one halogen lamp and a LEDs system. Brackets for premolar were bonded through composite resin. Samples were submitted to standardized tests. A comparison between used sources under shear bonding strength test, obtained similar results; however, tensile bonding test showed distinct results: a statistical difference at a level of 1% between exposure times (40 and 60 seconds) and even to an interaction between light source and exposure time. The best result was obtained with halogen lamp use by 60 seconds, even during re-bonding; however LEDs system can be used for bonding and re-bonding brackets if power density could be increased.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Since the 1980s, different devices based on superelastic alloys have been developed to fulfill orthodontic applications. Particularly in the last decades several researches have been carried out to evaluate the mechanical behavior of Ni-Ti alloys, including their tensile, torsion and fatigue properties. However, studies regarding the dependence of elastic properties on residence time of Ni-Ti wires in the oral cavity are scarce. Such approach is essential since metallic alloys are submitted to mechanical stresses during orthodontic treatment as well as pH and temperature fluctuations. The goal of the present contribution is to provide elastic stress-strain results to guide the orthodontic choice between martensitic thermal activated and austenitic superelastic Ni-Ti alloys. From the point of view of an orthodontist, the selection of appropriate materials and the correct maintenance of the orthodontic apparatus are essential needs during clinical treatment. The present work evaluated the elastic behavior of Ni-Ti alloy wires with diameters varying from 0.014 to 0.020 inches, submitted to hysteresis tensile tests with 8% strain. Tensile tests were performed after periods of use of 1, 2 and 3 months in the oral cavity of patients submitted to orthodontic treatment. The results from the hysteresis tests allowed to exam the strain range covered by isostress lines upon loading and unloading, as well as the residual strain after unloading for both superelastic and thermal activated Ni-Ti wires. Superelastic Ni-Ti wires exhibited higher load isostress values compared to thermal activated wires. It was found that such differences in the load isostress values can increase with increasing residence time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the tensile strength of orthodontic wires bonded onto the enamel with cyanoacrylate ester. To obtain the specimens, 120 human premolars (extracted for orthodontic or periodontal reasons) were included in acrylic blocks of rapid polymerization with three teeth each. Four groups were formed with ten specimens each. In the specimens, a dental splint model was made with cyanoacrylate ester and round stainless steel wire. In groups I, II and III, cyanoacrylate ester was used with round steel wires, with variation in diameter: 0.014 inches; 0.016 inches and 0.018 inches, respectively. In group IV, round steel wire 0.018 inches was used with photo polymerizing resin composite with previous acid etching. The adhesive force of the materials was measured in two points under the action of the tensiometer (ETM-USA). The number of loose wires was counted along with those that remained fixed according to the different levels of force applied because of the direction of the tensile force (vertical or horizontal) and the diameter of the wire used. The data obtained were first submitted to a descriptive analysis and then submitted to a statistical analysis (Friedman's Test and Dunn's Test of Multiple Comparison - Epi-info 3.2). Within the limitations of the experimental conditions presented, the cyanoacrylate ester or 'Super Bonder (R)' maintained bonded to enamel and steel wires (0.016 and 0.018 inches) during the tensile strength tests under different levels of applied forces.