907 resultados para OPTICAL-DETECTION


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Enhanced near-infrared photoluminescence (PL) from sulfur-related isoelectronic luminescent centers in silicon was observed from thermally quenched sulfur-implanted silicon in which additional copper or silver ions had been coimplanted. The PL from the sulfur and copper coimplanted silicon peaked between 70 and 100 K and persisted to 260 K. This result strongly supports the original conjecture from the optical detection of magnetic resonance studies that the strong PL from sulfur-doped silicon comes from S-Cu isoelectronic complexes [Frens , Phys. Rev. B 46, 12316 (1992); Mason , ibid. 58, 7007 (1998).]. (c) 2007 American Institute of Physics.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We combine theories of optimal pump-dump control and the related transient probe absorption spectroscopy in order to elucidate the relation between these two optical processes and the possibility of experimental realization. In the weak response regime, we identify the globally optimal pair of pump-dump control fields, and further propose a second-order difference detection scheme to monitor the wave packets dynamics that is jointly controlled by both the pump and dump fields. The globally optimal solution serves also as the initial input for the iterative search for the optimal control fields in the strong response regime. We use a model I-2 molecule to demonstrate numerically the pump-dump control and the detection of a highly vibrationally excited wave packet focusing dynamics on the ground X surface in both the weak and strong response regimes. The I2B surface serves as the intermediate to assist the pump-dump control and the optical detection processes. Demonstrated in the strong response regime are the optimal pair of pump-dump molecular-pi pulses that invert nearly total population onto the predefined target region within a half period of vibration motion. (C) 1999 American Institute of Physics. [S0021-9606(99)00115-4].

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Understanding tumor vascular dynamics through parameters such as blood flow and oxygenation can yield insight into tumor biology and therapeutic response. Hyperspectral microscopy enables optical detection of hemoglobin saturation or blood velocity by either acquiring multiple images that are spectrally distinct or by rapid acquisition at a single wavelength over time. However, the serial acquisition of spectral images over time prevents the ability to monitor rapid changes in vascular dynamics and cannot monitor concurrent changes in oxygenation and flow rate. Here, we introduce snap shot-multispectral imaging (SS-MSI) for use in imaging the microvasculature in mouse dorsal-window chambers. By spatially multiplexing spectral information into a single-image capture, simultaneous acquisition of dynamic hemoglobin saturation and blood flow over time is achieved down to the capillary level and provides an improved optical tool for monitoring rapid in vivo vascular dynamics.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Ecological studies that examine species-environment relationships are often limited to several meteorological parameters, i.e. mean air temperature, relative humidity, precipitation, vapour pressure deficit and solar radiation. The impact of local wind, its speed and direction are less commonly investigated in aerobiological surveys mainly due to difficulties related to the employment of specific analytical tools and interpretation of their outputs. Identification of inoculum sources of economically important plant pathogens, as well as highly allergenic bioaerosols like Cladosporium species, has not been yet explored with remote sensing data and atmospheric models such as Hybrid Single Particle Lagrangian Integrated Trajectory (HYSPLIT). We, therefore, performed an analysis of 24 h intra-diurnal cycle of Cladosporium spp. spores from an urban site in connection with both the local wind direction and overall air mass direction computed by HYSPLIT. The observational method was a volumetric air sampler of the Hirst design with 1 h time resolution and corresponding optical detection of fungal spores with light microscopy. The atmospheric modelling was done using the on-line data set from GDAS with 1° resolution and circular statistical methods. Our results showed stronger, statistically significant correlation (p ≤ 0.05) between high Cladosporium spp. spore concentration and air mass direction compared to the local wind direction. This suggested that a large fraction of the investigated fungal spores had a regional origin and must be located more than a few kilometers away from the sampling point.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

NDIR is proposed for monitoring of air pollutants emitted by ship engines. Careful optical filtering overcomes the challenge of optical detection of NO2 in humid exhaust gas, despite spectroscopic overlap with the water vapour band.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The successful immobilization of enzymes such as horseradish peroxidase (HRP) in solid films is essential for applications in sensors and for fundamental studies aimed at identifying possible biotechnological devices. In this study we show that HRP can be immobilized in alternated layers with chitosan as the template material. The activity of HRP in HRP/chitosan films was preserved for several weeks, and could be detected optically upon monitoring the reaction with pyrogallol. The morphology of the film displayed stripes that disappeared after reaction with pyrogallol. Though the activity in the HRP/chitosan film was lower than in a homogeneous solution or in an LB film investigated earlier, the response was linear for a considerable period of time, which may be advantageous for sensing hydrogen peroxide. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

dThe detection of aromatic compounds from pesticides and industrial wastewater has become of great interest, since these compounds withstand chemical oxidation and biological degradation, accumulating in the environment. In this work, a highly sensitive biosensor for detecting catechol was obtained with the immobilization of Cl-catechol 1,2-dioxygenase (CCD) in nanostructured films. CCD layers were alternated with poly(amidoamine) generation 4 (PAMAM G4) dendrimer using the electrostatic layer-by-layer (LbL) technique. Circular dichroism (CD) measurements indicated that the immobilized CCD preserved the same conformation as in solution. The thickness of the very first CCD layers in the LbL films was estimated at ca. 3.6 nm, as revealed by surface plasmon resonance (SPR). PAMAM/CCD 10-bilayer films were employed in detecting diluted catechol solutions using either an optical or electrical approach. Due to the mild immobilization conditions employed, especially regarding the pH and ionic strength of the dipping solutions, CCD remained active in the films for periods longer than 3 weeks. The optical detection comprised absorption experiments in which the formation of cis-cis muconic acid, resulting from the reaction between CCD and catechol, was monitored by measuring the absorbance at 260 nm after film immersion in catechol solutions. The electrical detection was carried out using LbL films deposited onto gold-interdigitated electrodes immersed in aqueous solutions at different catechol concentrations. Using impedance spectroscopy in a broad frequency range (1Hz-1kHz), we could detect catechol in solutions at concentrations as low as 10(-10) M. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The magnetic circular dichroism (MCD) of F2+ centers in KCl:SH- has been measured in absorption in the 1ssigma(g) --> 2p(y)pi(u) transitions at 493 and 509 nm, with fields up to 5 T and in the temperature range 1.5 K < T < 77 K. Within the limit of detection, no MCD is observed in the near infrared transition 1ssigma(g) --> 2psigma(u) as well as in both emissions 2ppi(u) --> 1ssigma(g) and 2psigma(u) --> 1ssigma(g). The optical detection of EPR in the F2+ ground state presents an isotropic single band with g = 1.965 +/- 0.007. The spin-lattice relaxation measured at H = 0.32 T is typical of a direct process T-1 = 4.3 x 10(-2_ coth (gmu(B)H/2k(B)T). The spectral variation of the MCD is calculated using perturbation theory to first order. The Hamiltonian includes the spin-orbit interaction in the 2ppi(u) excited state and the orbital molecular wave functions are obtained by a linear combination of 1s and 2p atomic orbitals. The calculated MCD is in good agreement with the observed one, for the spin-orbit interaction strength Pound(z) = 3.6 meV.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Nowadays, the attainment of microsystems that integrate most of the stages involved in an analytical process has raised an enormous interest in several research fields. This approach provides experimental set-ups of increased robustness and reliability, which simplify their application to in-line and continuous biomedical and environmental monitoring. In this work, a novel, compact and autonomous microanalyzer aimed at multiwavelength colorimetric determinations is presented. It integrates the microfluidics (a three-dimensional mixer and a 25 mm length "Z-shape" optical flow-cell), a highly versatile multiwavelength optical detection system and the associated electronics for signal processing and drive, all in the same device. The flexibility provided by its design allows the microanalyzer to be operated either in single fixed mode to provide a dedicated photometer or in multiple wavelength mode to obtain discrete pseudospectra. To increase its reliability, automate its operation and allow it to work under unattended conditions, a multicommutation sub-system was developed and integrated with the experimental set-up. The device was initially evaluated in the absence of chemical reactions using four acidochromic dyes and later applied to determine some key environmental parameters such as phenol index, chromium(VI) and nitrite ions. Results were comparable with those obtained with commercial instrumentation and allowed to demonstrate the versatility of the proposed microanalyzer as an autonomous and portable device able to be applied to other analytical methodologies based on colorimetric determinations.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The only nuclear model independent method for the determination of nuclear charge radii of short-lived radioactive isotopes is the measurement of the isotope shift. For light elements (Z < 10) extremely high accuracy in experiment and theory is required and was only reached for He and Li so far. The nuclear charge radii of the lightest elements are of great interest because they have isotopes which exhibit so-called halo nuclei. Those nuclei are characterized by a a very exotic nuclear structure: They have a compact core and an area of less dense nuclear matter that extends far from this core. Examples for halo nuclei are 6^He, 8^He, 11^Li and 11^Be that is investigated in this thesis. Furthermore these isotopes are of interest because up to now only for such systems with a few nucleons the nuclear structure can be calculated ab-initio. In the Institut für Kernchemie at the Johannes Gutenberg-Universität Mainz two approaches with different accuracy were developed. The goal of these approaches was the measurement of the isotope shifts between (7,10,11)^Be^+ and 9^Be^+ in the D1 line. The …first approach is laser spectroscopy on laser cooled Be^+ ions that are trapped in a linear Paul trap. The accessible accuracy should be in the order of some 100 kHz. In this thesis two types of linear Paul traps were developed for this purpose. Moreover, the peripheral experimental setup was simulated and constructed. It allows the efficient deceleration of fast ions with an initial energy of 60 keV down to some eV and an effcient transport into the ion trap. For one of the Paul traps the ion trapping could already be demonstrated, while the optical detection of captured 9^Be^+ ions could not be completed, because the development work was delayed by the second approach. The second approach uses the technique of collinear laser spectroscopy that was already applied in the last 30 years for measuring isotope shifts of plenty of heavier isotopes. For light elements (Z < 10), it was so far not possible to reach the accuracy that is required to extract information about nuclear charge radii. The combination of collinear laser spectroscopy with the most modern methods of frequency metrology …finally permitted the …first-time determination of the nuclear charge radii of (7,10)^Be and the one neutron halo nucleus 11^Be at the COLLAPS experiment at ISOLDE/ CERN. In the course of the work reported in this thesis it was possible to measure the absolute transition frequencies and the isotope shifts in the D1 line for the Be isotopes mentioned above with an accuracy of better than 2 MHz. Combination with the most recent calculations of the mass effect allowed the extraction of the nuclear charge radii of (7,10,11)^Be with an relative accuracy better than 1%. The nuclear charge radius decreases from 7^Be continuously to 10^Be and increases again for 11^Be. This result is compared with predictions of ab-initio nuclear models which reproduce the observed trend. Particularly the "Greens Function Monte Carlo" and the "Fermionic Molecular Dynamic" model show very good agreement.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Membranproteine spielen eine wichtige Rolle bei physiologischen Prozessen wie Signalweiterleitung oder Immunreaktion. Deshalb stehen sie im Fokus der pharmakologischen Wirkstoffentwicklung und es besteht großes Interesse, Membranproteinbasierte Biosensoren zu entwickeln, die sich z.B. als Screening-Plattformen eignen. Allerdings stellt die Handhabung von Membranproteinen wegen ihrer amphiphilen Struktur eine große Herausforderung dar. Membranproteine werden meist in Zellkultur oder in bakteriellen Expressionssystemen synthetisiert. Diese Verfahren liefern aber oft nur eine geringe Ausbeute und erlauben wenig Kontrolle über die Expressionsbedingungen. Als alternativer Ansatz bietet sich stattdessen die in vitro Synthese von Proteinen an, die in einer zellfreien Umgebung stattfindet. Ziel der vorliegenden Arbeit war die Etablierung eines miniaturisierten Analysesystems, das Aktivitätsmessungen an in vitro synthetisierten Ionenkanälen erlaubt. Dafür wurde ein Labon- Chip entwickelt, der elektrochemische und optische Nachweismethoden in parallelen Anätzen ermöglicht. Als amphiphile Umgebung für die Inkorporation von Membranproteinen wurden vier verschieden biomimetische Membranaufbauten hinsichtlich ihrer Dichtigkeit und ihrer Reproduzierbarkeit untersucht. Als Methode fanden insbesondere die Impedanzspektroskpie und die Oberflächenplasmonen-Resonanzspektroskopie Anwendung. Die peptide cushioned Bilyer Lipid Membranes (pcBLM) eignete sich dabei am besten für Untersuchungen an Membranproteinen. Zur Detektion der Ionenkanalaktivität wurde eine neue Messmethode etabliert, die auf der Messung der Impedanz bei fester Frequenz basiert und u.a. eine Aussage über die Änderung des Membranwiderstandes bei Aktivierung erlaubt. Am Beispiel des nicotinischen Acetylcholinrezeptors (nAchR) konnte gezeigt werden, dass sich die Aktivität von Ionenkanälen mit dem entwickelten Chip-System nachweisen ließ. Die Spezifität der Methode konnte durch verschiedene Kontrollen wie die Zugabe eines nicht-aktivierenden Liganden oder Inhibition des Rezeptors nachgewiesen werden. Weiterhin konnte die in vitro Synthese des Ionenkanals a7 nAchR durch Radioaktivmarkierung nachgewiesen werden. Die Inkorporation des Rezeptors in die biomimetischen Membranen wurde mit Immunodetektion und elektrochemischen Methoden untersucht. Es zeigte sich, dass die funktionelle Inkorporation des a7 nAchR davon abhing, welcher biomimetische Membranaufbau verwendet wurde.