954 resultados para Non-invasive temperature estimation
Resumo:
Recently, a number of cases of smuggling dissolved cocaine in wine bottles have been reported. The aim of the present study was to determine whether cocaine dissolved in wine can be detected by proton magnetic resonance spectroscopy ((1) H MRS) on a standard clinical MR scanner, in intact (i.e. unopened) wine bottles. (1) H MRS experiments were performed with a 3 Tesla clinical scanner on wine phantoms with or without cocaine contamination. The aromatic protons of cocaine displayed resonance peaks in the 7-8 ppm region of the spectrum, where no overlapping resonances of wine were present. Additional cocaine resonances were detected in the 2-3 ppm region of the spectrum, between the resonances of ethanol and other wine constituents. Detection of cocaine in wine (at 5 mM, i.e. ∼1.5 g/L) was feasible in a scan time of 1 min. We conclude that dissolved cocaine can be detected in intact wine bottles, on a standard clinical MR scanner. Thus, (1) H MRS is the technique of choice to examine this type of suspicious cargo, since it allows for a non-destructive and rapid content characterization. Copyright © 2010 John Wiley & Sons, Ltd.
Resumo:
INTRODUCTION. The role of turbine-based NIV ventilators (TBV) versus ICU ventilators with NIV mode activated (ICUV) to deliver NIV in case of severe respiratory failure remains debated. OBJECTIVES. To compare the response time and pressurization capacity of TBV and ICUV during simulated NIV with normal and increased respiratory demand, in condition of normal and obstructive respiratory mechanics. METHODS. In a two-chamber lung model, a ventilator simulated normal (P0.1 = 2 mbar, respiratory rate RR = 15/min) or increased (P0.1 = 6 mbar, RR = 25/min) respiratory demand. NIV was simulated by connecting the lung model (compliance 100 ml/mbar; resistance 5 or 20 l/mbar) to a dummy head equipped with a naso-buccal mask. Connections allowed intentional leaks (29 ± 5 % of insufflated volume). Ventilators to test: Servo-i (Maquet), V60 and Vision (Philips Respironics) were connected via a standard circuit to the mask. Applied pressure support levels (PSL) were 7 mbar for normal and 14 mbar for increased demand. Airway pressure and flow were measured in the ventilator circuit and in the simulated airway. Ventilator performance was assessed by determining trigger delay (Td, ms), pressure time product at 300 ms (PTP300, mbar s) and inspiratory tidal volume (VT, ml) and compared by three-way ANOVA for the effect of inspiratory effort, resistance and the ventilator. Differences between ventilators for each condition were tested by oneway ANOVA and contrast (JMP 8.0.1, p\0.05). RESULTS. Inspiratory demand and resistance had a significant effect throughout all comparisons. Ventilator data figure in Table 1 (normal demand) and 2 (increased demand): (a) different from Servo-i, (b) different from V60.CONCLUSION. In this NIV bench study, with leaks, trigger delay was shorter for TBV with normal respiratory demand. By contrast, it was shorter for ICUV when respiratory demand was high. ICUV afforded better pressurization (PTP 300) with increased demand and PSL, particularly with increased resistance. TBV provided a higher inspiratory VT (i.e., downstream from the leaks) with normal demand, and a significantly (although minimally) lower VT with increased demand and PSL.
Resumo:
Introduction Because it decreases intubation rate and mortality, NIV has become first-line treatment in case of hypercapnic acute respiratory failure (HARF). Whether this approach is equally successful for all categories of HARF patients is however debated. We assessed if any clinical characteristics of HARF patients were associated with NIV intensity, success, and outcome, in order to identify prognostic factors. Methods Retrospective analysis of the clinical database (clinical information system and MDSi) of patients consecutively admitted to our medico-surgical ICU, presenting with HARF (defined as PaCO2 > 50 mmHg), and receiving NIV between May 2008 and December 2010. Demographic data, medical diagnoses (including documented chronic lung disease), reason for ICU hospitalization, recent surgical interventions, SAPS II and McCabe scores were extracted from the database. Total duration of NIV and the need for tracheal intubation during the 5 days following the first hypercapnia documentation, as well as ICU, hospital and one year mortality were recorded. Results are reported as median [IQR]. Comparisons were carried out with Chi2 or Kruskal-Wallis tests, p<0.05 (*). Results Two hundred and twenty patients were included. NIV successful patients received 16 [9-31] hours of NIV for up to 5 days. Fifty patients (22.7%) were intubated 11 [2-34] hours after HARF occurence, after having receiving 10 [5-21] hours of NIV. Intubation was correlated with increased ICU (18% vs. 6%, p<0.05) and hospital (42% vs. 31%, p>0.05) mortality. SAPS II score was related to increasing ICU (51 [29-74] vs. 23 [12-41]%, p<0.05), hospital (37% [20-59] vs 20% [12-37], p<0.05) and one year mortality (35% vs 20%, p<0.05). Surgical patients were less frequent among hospital fatalities (28.8% vs. 46.3%, p<0.05, RR 0.8 [0-6-0.9]). Nineteen patients (8.6%) died in the ICU, 73 (33.2%) during their hospital stay and 108 (49.1%) were dead one year after HARF. Conclusion The practice to start NIV in all suitable patients suffering from HARF is appropriate. NIV can safely and appropriately be used in patients suffering from HARF from an origin different from COPD exacerbation. Beside usual predictors of severity such as severity score (SAPS II) appear to be associated with increased mortality. Although ICU mortality was low in our patients, hospital and one year mortality were substantial. Surgical patients, although undergoing a similar ICU course, had a better hospital and one year outcome.
Resumo:
Digital holography microscopy (DHM) is an optical microscopy technique which allows recording non-invasively the phase shift induced by living cells with nanometric sensitivity. Here, we exploit the phase signal as an indicator of dry mass (related to the protein concentration). This parameter allows monitoring the protein production rate and its evolution during the cell cycle. ©2008 COPYRIGHT SPIE
Resumo:
Non-invasive markers of fibrosis have been used to diagnose liver fibrosis in a variety of diseases. Hyaluronic acid (HA) and collagen IV (C-IV) levels were measured in the sera of patients from an endemic area for schistosomiasis in Brazil to diagnose and to rank the intensity of liver fibrosis. Seventy-nine adult patients with schistosomiasis, in the age range of 21-82 years (49 ± 13.4) were submitted to clinical and ultrasonographic examinations. Ultrasound was employed to diagnose and categorise liver fibrosis according to World Health Organization patterns. Serum HA and C-IV levels were measured using commercial ELISA kits. Ultrasound revealed six patients with intense liver fibrosis, 21 with moderate, 23 with light and 29 without. Serum HA was able to separate individuals with fibrosis from those without (p < 0.001) and light from intense fibrosis (p = 0.029), but C-IV was not (p = 0.692). The HA diagnostic accuracy for fibrosis was 0.89. The 115.4 ng/mL cut-off level diagnosed patients with fibrosis (sensitivity 0.98, specificity 0.64). HA correlated positively with portal hypertension. Periportal fibrosis (subjective evaluation), age and collateral circulation predicted HA increase. In conclusion, we propose that serum HA can be used to identify patients with liver fibrosis in an endemic area for schistosomiasis mansoni in Brazil.
Resumo:
The multiple endocrine neoplasia type 2A (MEN2A) is a monogenic disorder characterized by an autosomal dominant pattern of inheritance which is characterized by high risk of medullary thyroid carcinoma in all mutation carriers. Although this disorder is classified as a rare disease, the patients affected have a low life quality and a very expensive and continuous treatment. At present, MEN2A is diagnosed by gene sequencing after birth, thus trying to start an early treatment and by reduction of morbidity and mortality. We first evaluated the presence of MEN2A mutation (C634Y) in serum of 25 patients, previously diagnosed by sequencing in peripheral blood leucocytes, using HRM genotyping analysis. In a second step, we used a COLD-PCR approach followed by HRM genotyping analysis for non-invasive prenatal diagnosis of a pregnant woman carrying a fetus with a C634Y mutation. HRM analysis revealed differences in melting curve shapes that correlated with patients diagnosed for MEN2A by gene sequencing analysis with 100% accuracy. Moreover, the pregnant woman carrying the fetus with the C634Y mutation revealed a melting curve shape in agreement with the positive controls in the COLD-PCR study. The mutation was confirmed by sequencing of the COLD-PCR amplification product. In conclusion, we have established a HRM analysis in serum samples as a new primary diagnosis method suitable for the detection of C634Y mutations in MEN2A patients. Simultaneously, we have applied the increase of sensitivity of COLD-PCR assay approach combined with HRM analysis for the non-invasive prenatal diagnosis of C634Y fetal mutations using pregnant women serum.
Resumo:
Trypanosoma cruzi infection has a large public health impact in Latin American countries. Although the transmission rates via blood transfusions and insect vectors have declined sharply in the past 20 years due to policies of the Southern Cone countries, a large number of people are still at risk for infection. Currently, no accepted experimental model or descriptions of the clinical signs that occur during the course of acute murine infection are available. The aim of this work was to use non-invasive methods to evaluate the clinical signs of Balb/c mice infected with the Y strain of T. cruzi. The infected mice displayed evident clinical changes beginning in the third week of infection. The mice were evaluated based on physical characteristics, spontaneous activity, exploratory behaviour and physiological alterations. We hope that the results presented in this report provide parameters that complement the effective monitoring of trypanocidal treatment and other interventions used to treat experimental Chagas disease.
Resumo:
Echocardiography is the preferred initial test to assess cardiac morphology and ventricular function. Cardiac MRI enables an optimal visualisation of heart muscle without contrast injection, and precise measurement of the ventricular volumes and systolic function. It is therefore an ideal test for patients with poor echocardiographic windows or for the specific evaluation of right heart chambers. Heart CT also remarkably images heart muscle and precisely measures ventricular systolic function after intravenous injection of iodinated contrast. Coronary CT may also, in selected cases, avoid the need for diagnostic coronary angiography. Although very accurate, these imaging modalities are expensive and may be contra-indicated for a particular patient. Their use in clinical practice has to follow the accepted guidelines.
Resumo:
Objectifs : Evaluer une méthode simple et rapide de mesure du volume atrial gauche. Matériels et méthodes : Cinquante patients ont été examinés avec un CT gaté pour mesure du score calcique. Trois méthodes ont été utilisées pour calculer le volume atrial gauche : 1) une méthode orthogonale avec mesure des surfaces/diamètres dans les plans axiaux/coronaux/sagittaux, 2) une méthode biplan inspirée de l'échocardiographie et 3) une méthode volumétrique. Les mesures ont été faites par le même observateur un mois plus tard et ont été répétées par trois autres observateurs. L'axe cardiaque a aussi été mesuré. La méthode Bland-Altmann et les corrélations de Spearman ont été utilisées. Résultats : La méthode volumétrique montre les variations intra/interobservateur les plus basses avec une variabilité de 6,1/7,4 ml, respectivement. Pour les mesures avec la méthode orthogonale (surfaces/diamètres), les variations intra/interobservateur sont 12,3/13,5 ml et 14,6/11,6 ml, respectivement. Pour la méthode biplan, les variations intra/interobservateur sont plus hautes : 23,9/19,8 ml. Comparée à la méthode de référence volumétrique, la méthode orthogonale avec les surfaces est mieux corrélée (R=0,959, p<0,001) que les autres méthodes. Il y a une faible influence de l'axe du coeur sur la méthode orthogonale avec les surfaces. Conclusion : La méthode volumétrique est le gold standard en terme de variabilité. Cependant elle est longue à metttre en oeuvre. La méthode orthogonale avec les surfaces est une alternative simple, sauf chez les patients obèses avec un coeur horizontalisé.
Resumo:
A novel approach to the study of hepatic glycogen kinetics and fractional gluconeogenesis in vivo is described. Ten healthy female subjects were fed an iso-caloric diet containing 55% carbohydrate energy with a 13C abundance of 1.083 atom percent for a 3-day baseline period; then, a diet of similar composition, but providing carbohydrate with a 13C abundance of 1.093 atom percent was started and continued for 5 days. Resting respiratory gas exchanges, urinary nitrogen excretion, breath 13CO2 and plasma 13C glucose were measured every morning in the fasting state. The enrichment in 13C of hepatic glycogen was calculated from these measured data. 13C glycogen enrichment increased after switching to a 13C enriched carbohydrate diet, and was identical to the 13C enrichment of dietary carbohydrates after 3 days. The time required to renew 50% of hepatic glycogen, as determined from the kinetics of 13C glycogen enrichment, was 18.9 +/- 3.6 h. Fractional gluconeogenesis, as determined from the difference between the enrichments of glucose oxidized originating from hepatic glycogen and plasma glucose 13C was 50.8 +/- 5.3%. This non-invasive method will allow the study of hepatic glycogen metabolism in insulin-resistant patients.
Resumo:
RESUME : L'application d'une ventilation non-invasive (VNI) à pression positive chez des patients avec une insuffisance respiratoire aiguë hypoxémique non liée à une broncho-pneumopathie chronique obstructive (BPCO), reste controversée malgré les résultats encourageants apparus dans de récentes études. Ce travail de thèse est composé d'une introduction qui comprend un historique de la VNI et une revue de ces applications principales dans l'insuffisance respiratoire aiguë avec, en particulier, une analyse des études cliniques principales concernant son utilisation dans l'exacerbation de la BPCO, dans l'asthme aigu sévère, dans les syndromes restrictifs et dans l'insuffisance respiratoire aiguë hypoxémique. La première partie aborde également les aspects pratiques de l'utilisation de la VNI, avec une description de l'équipement et des techniques utilisées. Ce travail de thèse a ensuite pour but d'analyser dans une étude personnelle l'application d'une VNI à pression positive chez des patients avec une insuffisance respiratoire aiguë hypoxémique non liée à une BPCO. Il s'agit d'une étude prospective et observationnelle, dans laquelle nous avons voulu analyser l'efficacité de la VNI chez un groupe de patients sélectionnés et coopérants, stables du point de vue hémodynamique, présentant un syndrome de détresse respiratoire aiguë (SDRA) primaire (atteinte pulmonaire directe). Les échanges gazeux, le taux d'intubation, la mortalité et la durée de séjour dans l'unité de soins intensifs ont été enregistrés. Dans notre travail, la VNI a été appliquée de manière prospective à 12 patients, stables du point de vue hémodynamique, présentant les critères diagnostiques pour un SDRA primaire (SDRAP) et une indication pour une ventilation mécanique classique. Leur évolution a été comparée avec celle d'un groupe contrôle de 12 patients avec SDRAP. et précédemment traités dans la même unité de soins intensifs, ayant des caractéristiques similaires à l'admission : âge, score SAPS II, rapport Pa02/Fi02 et valeurs de pH . Un échec de la VNI fut observé chez 4 patients (33%), tous bactériémiques et nécessitant une intubation endotrachéale. Un facteur prédictif négatif. Les patients traités avec succès ont présenté un temps cumulatif de ventilation (p=0.001) et une durée de séjour aux soins intensifs (p=0.004) inférieure à ceux du groupe contrôle. Pendant la première période d'observation de la ventilation, l'oxygénation après 60 minutes s'est améliorée de manière plus importante dans le groupe VNI par rapport au groupe contrôle (PaO2/FiO2 : 146 +/- 52 mmHg vs. 109 +/- 34 mmHg ; p=0.05). Le taux de mortalité globale aux soins intensifs ne fut pas différent entre le groupe VNI et le groupe de patients intubés. Le taux de complications graves fut plus élevé chez les patients du groupe contrôle. Nos résultats suggèrent que chez des patients stables et coopérants, avec une pneumonie étendue, sans bactériémie à l'admission et remplissant les critères diagnostiques d'un SDRAp, la VNI représente une alternative valable à l'intubation endotrachéale.