977 resultados para Nasal CPAP


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The purpose of this study was to evaluate collagen deposition, mRNA collagen synthesis and TGFbeta expression in the lung tissue in an experimental model of scleroderma after collagen V-induced nasal tolerance. Methods: Female New Zealand rabbits (N = 12) were immunized with 1 mg/ml of collagen V in Freund's adjuvant (IM). After 150 days, six immunized animals were tolerated by nasal administration of collagen V ( 25 mu g/day) (IM-TOL) daily for 60 days. The collagen content was determined by morphometry, and mRNA expressions of types I, III and V collagen were determined by Real-time PCR. The TGF-beta expression was evaluated by immunostaining and quantified by point counting methods. To statistic analysis ANOVA with Bonferroni test were employed for multiple comparison when appropriate and the level of significance was determined to be p < 0.05. Results: IM-TOL, when compared to IM, showed significant reduction in total collagen content around the vessels (0.371 +/- 0.118 vs. 0.874 +/- 0.282, p < 0.001), bronchioles (0.294 +/- 0.139 vs. 0.646 +/- 0.172, p < 0.001) and in the septal interstitium (0.027 +/- 0.014 vs. 0.067 +/- 0.039, p = 0.026). The lung tissue of IM-TOL, when compared to IM, showed decreased immunostaining of types I, III and V collagen, reduced mRNA expression of types I (0.10 +/- 0.07 vs. 1.0 +/- 0.528, p = 0.002) and V (1.12 +/- 0.42 vs. 4.74 +/- 2.25, p = 0.009) collagen, in addition to decreased TGF-beta expression ( p < 0.0001). Conclusions: Collagen V-induced nasal tolerance in the experimental model of SSc regulated the pulmonary remodeling process, inhibiting collagen deposition and collagen I and V mRNA synthesis. Additionally, it decreased TGF-beta expression, suggesting a promising therapeutic option for scleroderma treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The area above the nasal cavity plays a role in respiratory physiology. Aim: To analyze, during a period of growth, a possible change in the minimum cross sectional area (MCA) and nasal volume of the anterior nasal cavity. Materials and Methods: We evaluated 29 children (14 boys and 15 girls) with a mean age of 7.81 years at first examination (M1) and 11.27 years in the second examination (M2), without symptoms of nasal obstruction. The interval between examinations was 36-48 months. Children were subjected to the examination of acoustic rhinometry in which we recorded the minimum cross-sectional areas, volumes and their correlations with gender. Study design: Cohort. Results: The mean cross-sectional area of the nasal cavity of MCA for girls was 0.30 +/- 0.09 cm2 (M1) and 0.30 +/- 0.14 cm2 (M2), while for boys was 0.24 +/- 0.12 cm2 (M1) and 0.32 +/- 0.10 cm2 (M2). The mean values of the total volumes found for the whole sample were 2.17 +/- 0.23 cm3 (MCA1-M1), 2.56 +/- 0.27 cm3 (MCA1-M2), 4.24 +/- 1.17 cm3 (MCA2-M2) and 4.63 +/- 1.10 cm3 (MCA2-M2). Conclusion: There was no significant change in the minimum cross sectional area of the anterior nasal cavity. There was no significant difference between genders for both MCA and for the volume. There was a significant increase in MCA1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Inhaled endotoxin (lipopolysaccharide, LPS) initiates an inflammatory response and leads to the expression of CR3 (CD11b/CD18) receptors on polymorphonuclear leukocytes (PMNs). We determined if PMN activation in nasal lavage fluid (NLF) is a possible biomarker of occupational endotoxin exposure. Seven subjects exposed to endotoxin provided NLF samples that were split into three aliquots (negative control - 1 M nicotinamide; sham; positive control - 11 eta g of exogenous LPS) and PMN activation was measured using a chemiluminometer. Differences in mean PMN activation were apparent, negative control: 548 +/- 15.65 RLU 100 mu l(-1); sham: 11469 +/- 2582 RLU 100 mu l(-1); positive control: 42026 +/- 16659 RLU 100 mu l (n = 7; p < 0.05). This technique shows promise as a diagnostic method for measuring upper airway LPS exposure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Number 3 cleft or oral-nasal-ocular cleft is a well-known entity that was described by Morian over a century ago. This malformation is a paranasal-medial orbitomaxillary cleft running across the lacrimal segment of the lower eyelid and over the lacrimal groove. The Tessier number 3 naso-ocular cleft represents one of the most difficult and challenging malformations to correct for the reconstructive surgeon. We have conducted a retrospective analysis of our series consisting of 21 cases. Objective: The objective was to review the functional outcome and aesthetic results of the different techniques applied for each case. Materials and Methods: From 1997 to 2007, 21 patients with a Tessier number 3 cleft were treated in our craniofacial units. The clinical findings, tomographic studies, and surgical procedures were reviewed and analyzed. We have discussed our protocol of the treatment. Results: We have treated facial malformation in 2 craniofacial centers. Fourteen patients were evaluated in the first year of their life, with an average age at presentation of 3 years. Twelve patients were female, and 9 were male; 6 patients had amniotic bands in limbs, 5 patients had an association with Tessier number 11 cleft, 3 patients with number 9 cleft, and 1 with number 7 cleft. Related to cleft lip, 10 patients had bilateral cleft lip, and 8 patients had unilateral cleft lip. Three patients did not have any involvement of the upper lip. The alar base was deviated upward in 19 patients, 11 cases had severe anatomic alteration with the lateral border of the ala above the medial canthus, and 8 cases had a mild dislocation. Nine cases of lacrimal duct obstruction and 8 cases of lacrimal duct extrophy were identified. Twelve patients had a lower eyelid coloboma of varying grades, and there were 2 cases of microblepharia. Aiming the soft tissue reconstruction, eyelid, nose, and upper lip were evaluated regarding their position, absence of tissue, and position of medial canthus and ala. Twelve of our patients underwent correction in the same moment, their medial canthus rotated upward and the ala downward, using the contralateral side as the reference. The lip was treated using a Millard-like technique. Neo-conjunctivorhinostomy was performed in the same moment in 2 patients or later in 1 case. Four patients had plagiocephaly due to the cranial involvement, and they were submitted to cranioplasty. Three had neurosurgical approach and advancement of the frontal bandeau. One adult patient received an acrylic plate to reshape the frontal area. Conclusions: Tessier number 3 cleft is one of the most difficult and challenging malformations to correct for the reconstructive surgeon. Besides the difficulties of its treatment, patients with Tessier number 3 cleft may achieve good results when the team has good skills.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Furosemide, a potent diuretic, affects ion and water movement across the respiratory epithelium. However, the effects of furosemide, as clinically used, on mucociliary clearance, a critical respiratory defense mechanism, are still lacking in humans. Fourteen young healthy subjects were assigned to three random interventions, spaced one-week apart: no intervention (control), oral furosemide (40 mg), and furosemide + oral volume replacement (F + R). Nasal mucociliary clearance was assessed by saccharine test (STT), and mucus properties were in vitro evaluated by means of contact angle and transportability by sneeze. Urine output and osmolality were also evaluated. Urine output increased and reduced urine osmolality in furosemide and F + R compared to the control condition. STT remained stable in the control group. In contrast, STT increased significantly (40%) after furosemide and F + R. There were no changes in vitro mucus properties in all groups. In conclusion, furosemide prolongs STT in healthy young subjects. This effect is not prevented by fluid replacement, suggesting a direct effect of furosemide on the respiratory epithelium. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Contact endoscopy (CE) was initially described as a method used in the analysis of uterine and vocal folds histology. The first nasal cavity CE studies achieved promising results regarding its use for the differentiation between benign and malignant lesions, considering that biopsy might cause some complications, especially bleeding. This study described and compared the findings of CE on inverted papilloma and nasosinusal squamous cell carcinoma (SCC) and tested the effectiveness of this exam as a noninvasive method for in vivo differentiation between these tumors. Methods: The patients included in this study were divided into group A, patients diagnosed with inverted papilloma, and group B, patients diagnosed with SCC. CE results were compared among themselves. CE images were presented to examiners not experienced with the method. Results: Twenty-two patients were examined, 13 in group A and 9 in group B. The main relevant differences in CE findings between those two groups were corkscrew vessels, presence of mitoses, keratinization and nuclear pleomorphism in carcinoma, and vacuolated cells in papilloma. The examiners were capable of defining the diagnosis of these nasal tumors only based on CE images. Conclusion: CE may be a useful noninvasive exam to be used in the in vivo diagnosis of inverted papilloma and nasosinusal SCC, which may enable better preoperative planning. (Am J Rhinol Allergy 24, 210-214, 2010; doi: 10.2500/ajra.2010.24.3467)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background:The Nasal Obstruction Symptom Evaluation (NOSE) instrument is a disease-specific questionnaire for assessing the outcome of an intervention in nasal obstruction in trials. This instrument is only available in the English language and cross-culturally valid questionnaires are very important for all research, including nasal obstruction. The aim of the current study was to reproduce the cross-cultural adaptation process for the NOSE questionnaire in the Portuguese language (NOSE-p). Methodology: Cross-cultural adaptation and validation of the instrument were divided into two stages. Stage I involved four bilingual professionals, an expert committee and the author of the original instrument. In Stage 2, the NOSE-p was tested on 33 patients undergoing septoplasty for internal consistency, test-retest reliability, construct validity. discriminant validity, criterion validity, and response sensitivity. Results: The cross-cultural adaptation process was completed and the NOSE-p was demonstrated to be a valid instrument with satisfactory construct validity. It showed an adequate internal consistency reliability and adequate test-retest reliability. It could discriminate between patients with and without nasal obstruction and it has a high response sensitivity to change. Conclusions: The cross-cultural adaptation and validation process demonstrated to be valid and the NOSE-p proved to be applicable in Brazil.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several epidemiological studies have linked particulate matter exposure to numerous adverse health effects on the respiratory, cardiovascular, and reproductive systems (Braga et al., 1999; Zanobetti et al., 2000; Anderson et al., 2001; Farhat et al., 2005). More recently, ambient levels of black carbon were associated to impaired cognitive function in children (Suglia et al., 2008), suggesting that the central nervous system (CNS) may be a target of air pollutants. The present study was conducted to (a) determine whether chronic residual oil fly ash (ROFA) exposure promotes behavioral changes and lipid peroxidation in rat brain areas, and (b) determine whether N-acetylcysteine (NAC), a general antioxidant, prevents these effects. Forty-five-day-old male Wistar rats were exposed or not to ROFA by intranasal instillation and were treated or not with NAC (150 mg/kg) ip for 30 days. One day later, rats were submitted to the open field test to evaluate the motor/exploratory activities and emotionality followed by decapitation. Striatum and cerebellum were dissected to determine lipid peroxidation by the accumulation of thiobarbituric acid-reactive substances (TBARS). ROFA instillation induced an increase in lipid peroxidation level in striatum (p = .033) and cerebellum (p = .030), as compared with the control group. NAC treatment blocked these changes. ROFA promoted a decrease in the frequency of peripheral walking (p = .006) and a decrease in exploration (p = .001), which were not blocked by N-acetylcysteine. The present study provides evidence that toxic particles, administered by the respiratory route, induce oxidative stress in structures of the central nervous system, as well as behavioral alterations. The administration of NAC reduces lipid peroxidation at the striatum and cerebellum levels, but does not influence behavioral disturbances.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. (1) Evaluate the presence of biofilms in patients with chronic sinusitis with nasal polyps (CRSwNP) and (2) investigate the association of biofilm presence and CRSwNP. Study Design. Cross-sectional study. Setting. University-based tertiary care center. Subjects and Methods. The study group consisted of 33 consecutive patients undergoing functional endoscopic sinus surgery for CRSwNP. The control group consisted of 27 control patients undergoing septoplasty for nasal obstruction without diagnosis of chronic sinusitis. Mucosal samples were harvested intraoperatively for scanning electron microscopic examination to determine biofilm presence. Statistical analysis was performed. For all statistical tests, P = .05 was considered significant. Results. Biofilms were found in 24 (72.7%) of the 33 patients with CRSwNP and in 13 (48.1%) of the 27 septoplasty patients (odds ratio = 2.87; 95% confidence interval, 0.98-8.42; P = .051). Conclusion. (1) Biofilms were present in patients undergoing functional endoscopic sinus surgery for CRSwNP and also in controls without chronic sinusitis. This suggests that biofilms may not be sufficient to cause chronic sinusitis without other cofactors. Host factors could be the responsible for the pathogenesis of biofilms. (2) Although the prevalence of biofilms in patients with CRSwNP was not significantly different from that in the controls, the extremely wide 95% confidence interval, which is just below unity, suggests that a meaningful clinical difference may have been missed because of low statistical power. Further studies are necessary.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background It is noteworthy that there is a clear clinical, epidemiological and pathophysiological association between upper and lower airway inflammation in rhinitis and asthma. Objective The aim of this study was to compare the eosinophil counts in induced sputum and nasal lavage fluids in asthma, checking their association and the accuracy of nasal eosinophilia as a predictor of sputum eosinophilia by a cross-sectional study. Methods The clinical evaluation, asthma control questionnaire (ACQ), pre- and post-bronchodilator spirometry, nasal and sputum sample was performed. The nasal eosinophilia was analysed by a receiver operating curve and logistic regression model. Results In 140 adults, the post-bronchodilator forced expiratory volume in 1 s (FEV(1)) did not differ between patients with or without sputum eosinophilia (0.18). After adjusted for upper airway symptoms, age, ACQ score and post-bronchodilator FEV(1), sputum eosinophilia was associated with 52 times increase in odds of nasal eosinophilia, whereas each 1% increase in bronchodilator response was associated with 7% increase in odds of nasal eosinophilia. Conclusion This study brings further evidence that upper airway diseases are an important component of the asthma syndrome. Furthermore, monitoring of nasal eosinophilia by quantitative cytology may be useful as a surrogate of sputum cytology in as a component of composite measurement for determining airway inflammation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diesel exhaust is the major source of ultrafine particles released during traffic-related pollution. Subjects with chronic respiratory diseases are at greater risk for exacerbations during exposure to air pollution. This study evaluated the effects of subchronic exposure to a low-dose of diesel exhaust particles (DEP). Sixty male BALB/c mice were divided into two groups: (a) Saline: nasal instillation of saline (n = 30); and (b) DEP: nasal instillation of 30 mu g of DEP/10 mu l of saline (n = 30). Nasal instillations were performed 5 days a week, over 30 and 60 days. Animals were anesthetized with pentobarbital sodium (50 mg/kg intraperitoneal [i.p.]) and sacrificed by exsanguination. Bronchoalveolar lavage (BAL) fluid was performed to evaluate the inflammatory cell count and the concentrations of the interleukin (IL)-4, IL-10, and IL-13 by enzyme-linked immunosorbent assay (ELISA). The gene expression of oligomeric mucus/gel-forming (Muc5ac) was evaluated by real-time polymerase chain reaction (PCR). Histological analysis in the nasal septum and bronchioles was used to evaluate the bronchial and nasal epithelium thickness as well as the acidic and neutral nasal mucus content. The saline group (30 and 60 days) did not show any changes in any of the parameters. However, the instillation of DEP over 60 days increased the expression of Muc5ac in the lungs and the acid mucus content in the nose compared with the 30-day treatment, and it increased the total leukocytes in the BAL and the nasal epithelium thickness compared with saline for 60 days. Cytokines concentrations in the BAL were detectable, with no differences among the groups. Our data suggest that a low-dose of DEP over 60 days induces respiratory tract inflammation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Obstructive sleep apnoea syndrome (OSAS) often coexists in patients with chronic obstructive pulmonary disease (COPD). The present prospective cohort study tested the effect of OSAS treatment with continuous positive airway pressure (CPAP) on the survival of hypoxaemic COPD patients. It was hypothesised that CPAP treatment would be associated with higher survival in patients with moderate-to-severe OSAS and hypoxaemic COPD receiving long-term oxygen therapy (LTOT). Prospective study participants attended two outpatient advanced lung disease LTOT clinics in Sao Paulo, Brazil, between January 1996 and July 2006. Of 603 hypoxaemic COPD patients receiving LTOT, 95 were diagnosed with moderate-to-severe OSAS. Of this OSAS group, 61 (64%) patients accepted and were adherent to CPAP treatment, and 34 did not accept or were not adherent and were considered not treated. The 5-yr survival estimate was 71% (95% confidence interval 53-83%) and 26% (12-43%) in the CPAP-treated and nontreated groups, respectively (p<0.01). After adjusting for several confounders, patients treated with CPAP showed a significantly lower risk of death (hazard ratio of death versus nontreated 0.19 (0.08-0.48)). The present study found that CPAP treatment was associated with higher survival in patients with moderate-to-severe OSAS and hypoxaemic COPD receiving LTOT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: Biofuel from sugarcane is widely produced in developing countries and is a clean and renewable alternative source of energy. However, sugarcane harvesting is mostly performed after biomass burning. The aim of this study was to evaluate the effects of harvesting after biomass burning on nasal mucociliary clearance and the nasal mucus properties of farm workers. Methods: Twenty seven sugarcane workers (21-45 years old) were evaluated at the end of two successive time-periods: first at the end of a 6-month harvesting period (harvesting), and then at the end of a 3-month period without harvesting (non-harvesting). Nasal mucociliary clearance was evaluated by the saccharine transit test, and mucus properties were analyzed using in vitro mucus contact angle and mucus transportability by sneeze. Arterial blood pressure, heart rate, respiratory rate, pulse oximetry, body temperature, associated illness, and exhaled carbon monoxide were registered. Results: Data are presented as mean values (95% confidence interval). The multivariate model analysis adjusted for age, body-mass index, smoking status and years of working with this agricultural practice showed that harvesting yielded prolonged saccharine transit test in 7.83 min (1.88-13.78), increased mucus contact angle in 8.68 degrees (3.18-14.17) and decreased transportability by sneeze in 32.12 mm (-44.83 to -19.42) compared with the non-harvesting period. No significant differences were detected in any of the clinical parameter at either time-period. Conclusion: Sugarcane harvesting after biomass burning negatively affects the first barrier of the respiratory system in farm workers by impairing nasal mucociliary clearance and inducing abnormal mucus properties. (C) 2011 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intra-nasally instilled benzodiazepines have been proposed for acute anxiety episodes. However, routes with faster absorption may increase abuse liability. This study compared abuse liability of intra-nasal midazolam between subjects with a history of intra-nasal drug abuse and non-psychiatric subjects on a single-blind randomized controlled trial. Thirty-one inhaled-cocaine abusers and 34 normal volunteers received either 1 mg intra-nasal midazolam or active placebo. Visual analogue scales assessing desire to repeat the experience (ER) and Experience Liking (EL) assessed abuse liability. Profile analysis for repeated measures showed a significant effect of time over ER (F-[5,F-57]=3.311, p=0.011) and EL (F-[5,F-57]=3.947, p=0.004), diagnostic group (cocaine abusers scoring higher on both - F-[5,F-57]=5.229, p=0.026; F-[5,F-57]=4.946, p=0.030), regardless of the administered substance. It is concluded that the intra-nasal route does not seem to pose risks for non-psychiatric individuals, but it may represent a risk in itself for subjects with a history of drug abuse through this path. (C) 2008 Elsevier B.V. and ECNP. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To evaluate the effect of rapid maxillary expansion (RME) on the dimension of the nasopharyngeal space and its relation to nasal airway resistance. Methods: Twenty-five school-age children (from 7 to 10 year-old) with mouth and/or mixed breathing, with mixed dentition and uni- or bilateral posterior crossbite involving the deciduous canines and the first permanent molars, were evaluated. RME was placed and remained during 90 days. Rhinomanometry and orthodontic documentation were performed at four different times, i.e., before (T(1)), immediately after (T(2)), 90 days (T(3)) and 30 months (T(4)) after RME. Results: Differences in nasopharyngeal area and in nasal airway resistance were observed only 30 months after RME, and could be explained by facial growth, and not because of the orthodontic procedure. Conclusion: RME does not influence on nasopharyngeal area or nasal airway resistance in long-term evaluation. (C) 2010 Elsevier Ireland Ltd. All rights reserved.