991 resultados para Mri Field Gradients


Relevância:

40.00% 40.00%

Publicador:

Resumo:

INTRODUCTION: Gamma Knife surgery (GKS) is a non-invasive neurosurgical stereotactic procedure, increasingly used as an alternative to open functional procedures. This includes targeting of the ventro-intermediate nucleus of the thalamus (e.g. Vim) for tremor. We currently perform an indirect targeting, as the Vim is not visible on current 3Tesla MRI acquisitions. Our objective was to enhance anatomic imaging (aiming at refining the precision of anatomic target selection by direct visualisation) in patients treated for tremor with Vim GKS, by using high field 7T MRI. MATERIALS AND METHODSH: Five young healthy subjects were scanned on 3 (T1-w and diffusion tensor imaging) and 7T (high-resolution susceptibility weighted images (SWI)) MRI in Lausanne. All images were further integrated for the first time into the Gamma Plan Software(®) (Elekta Instruments, AB, Sweden) and co-registered (with T1 was a reference). A simulation of targeting of the Vim was done using various methods on the 3T images. Furthermore, a correlation with the position of the found target with the 7T SWI was performed. The atlas of Morel et al. (Zurich, CH) was used to confirm the findings on a detailed analysis inside/outside the Gamma Plan. RESULTS: The use of SWI provided us with a superior resolution and an improved image contrast within the basal ganglia. This allowed visualization and direct delineation of some subgroups of thalamic nuclei in vivo, including the Vim. The position of the target, as assessed on 3T, perfectly matched with the supposed one of the Vim on the SWI. Furthermore, a 3-dimensional model of the Vim-target area was created on the basis of the obtained images. CONCLUSION: This is the first report of the integration of SWI high field MRI into the LGP, aiming at the improvement of targeting validation of the Vim in tremor. The anatomical correlation between the direct visualization on 7T and the current targeting methods on 3T (e.g. quadrilatere of Guyot, histological atlases) seems to show a very good anatomical matching. Further studies are needed to validate this technique, both by improving the accuracy of the targeting of the Vim (potentially also other thalamic nuclei) and to perform clinical assessment.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Mapping the human auditory cortex with standard functional imaging techniques is difficult because of its small size and angular position along the Sylvian fissure. As a result, the exact number and location of auditory cortex areas in the human remains unknown. In a first experiment, we measured the two largest tonotopic areas of primary auditory cortex (PAC, Al and R) using high-resolution functional MRI at 7 Tesla relative to the underlying anatomy of Heschl's gyrus (HG). The data reveals a clear anatomical- functional relationship that indicates the location of PAC across the range of common morphological variants of HG (single gyri, partial duplication and complete duplication). Human PAC tonotopic areas are oriented along an oblique posterior-to-anterior axis with mirror-symmetric frequency gradients perpendicular to HG, as in the macaque. In a second experiment, we tested whether these primary frequency-tuned units were modulated by selective attention to preferred vs. non-preferred sound frequencies in the dynamic manner needed to account for human listening abilities in noisy environments, such as cocktail parties or busy streets. We used a dual-stream selective attention experiment where subjects attended to one of two competing tonal streams presented simultaneously to different ears. Attention to low-frequency tones (250 Hz) enhanced neural responses within low-frequency-tuned voxels relative to high (4000 Hz), and vice versa when at-tention switched from high to low. Human PAC is able to tune into attended frequency channels and can switch frequencies on demand, like a radio. In a third experiment, we investigated repetition suppression effects to environmental sounds within primary and non-primary early-stage auditory areas, identified with the tonotopic mapping design. Repeated presentations of sounds from the same sources, as compared to different sources, gave repetition suppression effects within posterior and medial non-primary areas of the right hemisphere, reflecting their potential involvement in semantic representations. These three studies were conducted at 7 Tesla with high-resolution imaging. However, 7 Tesla scanners are, for the moment, not yet used for clinical diagnosis and mostly reside in institutions external to hospitals. Thus, hospital-based clinical functional and structural studies are mainly performed using lower field systems (1.5 or 3 Tesla). In a fourth experiment, we acquired tonotopic maps at 3 and 7 Tesla and evaluated the consistency of a tonotopic mapping paradigm between scanners. Mirror-symmetric gradients within PAC were highly similar at 7 and 3 Tesla across renderings at different spatial resolutions. We concluded that the tonotopic mapping paradigm is robust and suitable for definition of primary tonotopic areas, also at 3 Tesla. Finally, in a fifth study, we considered whether focal brain lesions alter tonotopic representations in the intact ipsi- and contralesional primary auditory cortex in three patients with hemispheric or cerebellar lesions, without and with auditory complaints. We found evidence for tonotopic reorganisation at the level of the primary auditory cortex in cases of brain lesions independently of auditory complaints. Overall, these results reflect a certain degree of plasticity within primary auditory cortex in different populations of subjects, assessed at different field strengths. - La cartographie du cortex auditif chez l'humain est difficile à réaliser avec des techniques d'imagerie fonctionnelle standard, étant donné sa petite taille et position angulaire le long de la fissure sylvienne. En conséquence, le nombre et l'emplacement exacts des différentes aires du cortex auditif restent inconnus chez l'homme. Lors d'une première expérience, nous avons mesuré, avec de l'imagerie par résonance magnétique à haute intensité (IRMf à 7 Tesla) chez des sujets humains sains, deux larges aires au sein du cortex auditif primaire (PAC; Al et R) avec une représentation spécifique des fréquences pures préférées - ou tonotopie. Nos résultats ont démontré une relation anatomico- fonctionnelle qui définit clairement la position du PAC à travers toutes les variantes du gyrus d'Heschl's (HG). Les aires tonotopiques du PAC humain sont orientées le long d'un axe postéro-antérieur oblique avec des gradients de fréquences spécifiques perpendiculaires à HG, d'une manière similaire à celles mesurées chez le singe. Dans une deuxième expérience, nous avons testé si ces aires primaires pouvaient être modulées, de façon dynamique, par une attention sélective pour des fréquences préférées par rapport à celles non-préférées. Cette modulation est primordiale lors d'interactions sociales chez l'humain en présence de bruits distracteurs tels que d'autres discussions ou un environnement sonore nuisible (comme par exemple, dans la circulation routière). Dans cette étude, nous avons utilisé une expérience d'attention sélective où le sujet devait être attentif à une des deux voies sonores présentées simultanément à chaque oreille. Lorsque le sujet portait était attentif aux sons de basses fréquences (250 Hz), la réponse neuronale relative à ces fréquences augmentait par rapport à celle des hautes fréquences (4000 Hz), et vice versa lorsque l'attention passait des hautes aux basses fréquences. De ce fait, nous pouvons dire que PAC est capable de focaliser sur la fréquence attendue et de changer de canal selon la demande, comme une radio. Lors d'une troisième expérience, nous avons étudié les effets de suppression due à la répétition de sons environnementaux dans les aires auditives primaires et non-primaires, d'abord identifiées via le protocole de la première étude. La présentation répétée de sons provenant de la même source sonore, par rapport à de sons de différentes sources sonores, a induit un effet de suppression dans les aires postérieures et médiales auditives non-primaires de l'hémisphère droite, reflétant une implication de ces aires dans la représentation de la catégorie sémantique. Ces trois études ont été réalisées avec de l'imagerie à haute résolution à 7 Tesla. Cependant, les scanners 7 Tesla ne sont pour le moment utilisés que pour de la recherche fondamentale, principalement dans des institutions externes, parfois proches du patient mais pas directement à son chevet. L'imagerie fonctionnelle et structurelle clinique se fait actuellement principalement avec des infrastructures cliniques à 1.5 ou 3 Tesla. Dans le cadre dune quatrième expérience, nous avons avons évalués la cohérence du paradigme de cartographie tonotopique à travers différents scanners (3 et 7 Tesla) chez les mêmes sujets. Nos résultats démontrent des gradients de fréquences définissant PAC très similaires à 3 et 7 Tesla. De ce fait, notre paradigme de définition des aires primaires auditives est robuste et applicable cliniquement. Finalement, nous avons évalués l'impact de lésions focales sur les représentations tonotopiques des aires auditives primaires des hémisphères intactes contralésionales et ipsilésionales chez trois patients avec des lésions hémisphériques ou cérébélleuses avec ou sans plaintes auditives. Nous avons trouvé l'évidence d'une certaine réorganisation des représentations topographiques au niveau de PAC dans le cas de lésions cérébrales indépendamment des plaintes auditives. En conclusion, nos résultats démontrent une certaine plasticité du cortex auditif primaire avec différentes populations de sujets et différents champs magnétiques.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

PURPOSE: To compare the apparent diffusion coefficient (ADC) values of malignant liver lesions on diffusion-weighted MRI (DWI) before and after successful radiofrequency ablation (RF ablation). MATERIALS AND METHODS: Thirty-two patients with 43 malignant liver lesions (23/20: metastases/hepatocellular carcinomas (HCC)) underwent liver MRI (3.0T) before (<1month) and after RF ablation (at 1, 3 and 6months) using T2-, gadolinium-enhanced T1- and DWI-weighted MR sequences. Jointly, two radiologists prospectively measured ADCs for each lesion by means of two different regions of interest (ROIs), first including the whole lesion and secondly the area with the visibly most restricted diffusion (MRDA) on ADC map. Changes of ADCs were evaluated with ANOVA and Dunnett tests. RESULTS: Thirty-one patients were successfully treated, while one patient was excluded due to focal recurrence. In metastases (n=22), the ADC in the whole lesion and in MRDA showed an up-and-down evolution. In HCC (n=20), the evolution of ADC was more complex, but with significantly higher values (p=0.013) at 1 and 6months after RF ablation. CONCLUSION: The ADC values of malignant liver lesions successfully treated by RF ablation show a predictable evolution and may help radiologists to monitor tumor response after treatment.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Aim: Gamma Knife surgery (GKS) is a non-invasive neurosurgical stereotactic procedure, increasingly used as an alternative to open functional procedures. This includes the targeting of the ventro-intermediate (Vim) nucleus of the thalamus for tremor. We currently perform an indirect targeting, using the "quadrilatere of Guyot," as the Vim nucleus is not visible on current 3 Tesla (T) MRI acquisitions. The primary objective of the current study was to enhance anatomic imaging for Vim GKS using high-field (7 T) MRI, with the aim of refining the visualization and precision of anatomical targeting. Method: Five young healthy subjects (mean age 23 years) were scanned both on 3 and 7 T MRI in Lausanne University Hospital (CHUV) and Center for Biomedical Imaging (CIBM). Classical T1-weighted MPRAGE, T2 CISS sequences (replacing former ventriculography) and diffusion tensor imaging were acquired at 3T. We obtained high-resolution susceptibility weighted images (SWI) at 7T for the visualization of thalamic subparts. SWI was further integrated for the first time into Leksell Gamma Plan® (LGP) software and co-registered with the 3T images. A simulation of targeting of the Vim was done using the "quadrilatere of Guyot" methodology on the 3T images. Furthermore, a correlation with the position of the found target on SWI was performed. The atlas of Morel et al. was used to confirm the findings on a detailed computer analysis outside LGP. Also, 3T and 7T MRI of one patient undergoing GKS Vim thalamotomy, were obtained before and 2 years after the procedure, and studied similarly. Results: The use of SWI provided a superior resolution and improved image contrast within the central gray matter. This allowed visualization and direct delineation of groups of thalamic nuclei in vivo, including the Vim. The position of the target, as assessed with the "quadrilatere of Guyot" method on 3 T, perfectly matched with the supposed one of the Vim on the SWI. Furthermore, a 3-dimensional model of the Vim target area was created on the basis of 3T and 7T images. Conclusion: This is the first report of the integration of SWI high-field MRI into the LGP in healthy subjects and in one patient treated GKS Vim thalamotomy. This approach aims at the improvement of targeting validation and further direct targeting of the Vim in tremor. The anatomical correlation between the direct visualization on 7T and the current targeting methods on 3T seems to show a very good anatomical matching.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Introduction: Gamma Knife surgery (GKS) is a noninvasive neurosurgical stereotactic procedure, increasingly used as an alternative to open functional procedures. This includes the targeting of the ventrointermediate nucleus of the thalamus (e.g., Vim) for tremor. Objective: To enhance anatomic imaging for Vim GKS using high-field (7 T) MRI and Diffusion Weighted Imaging (DWI). Methods: Five young healthy subjects and two patients were scanned both on 3 and 7 T MRI. The protocol was the same in all cases, and included: T1-weighted (T1w) and DWI at 3T; susceptibility weighted images (SWI) at 7T for the visualization of thalamic subparts. SWI was further integrated into the Gamma Plan Software® (LGP, Elekta Instruments, AB, Sweden) and co-registered with 3T images. A simulation of targeting of the Vim was done using the quadrilatere of Guyot. Furthermore, a correlation with the position of the found target on SWI and also on DWI (after clustering of the different thalamic nuclei) was performed. Results: For the 5 healthy subjects, there was a good correlation between the position of the Vim on SWI, DWI and the GKS targeting. For the patients, on the pretherapeutic acquisitions, SWI helped in positioning the target. For posttherapeutic sequences, SWI supposed position of the Vim matched the corresponding contrast enhancement seen at follow-up MRI. Additionally, on the patient's follow-up T1w images, we could observe a small area of contrast-enhancement corresponding to the target used in GKS (e.g., Vim), which belongs to the Ventral-Lateral-Ventral (VLV) nuclei group. Our clustering method resulted in seven thalamic groups. Conclusion: The use of SWI provided us with a superior resolution and an improved image contrast within the central gray matter, enabling us to directly visualize the Vim. We additionally propose a novel robust method for segmenting the thalamus in seven anatomical groups based on DWI. The localization of the GKS target on the follow-up T1w images, as well as the position of the Vim on 7 T, have been used as a gold standard for the validation of VLV cluster's emplacement. The contrast enhancement corresponding to the targeted area was always localized inside the expected cluster, providing strong evidence of the VLV segmentation accuracy. The anatomical correlation between the direct visualization on 7T and the current targeting methods on 3T (e.g., quadrilatere of Guyot, histological atlases, DWI) seems to show a very good anatomical matching.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This study compares the performance and the reproducibility of quantitative T2, T2* and the magnetisation transfer ratio (MTR) of articular cartilage at 7T and 3T.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Complete resection of grade II gliomas might prolong survival but is not always possible. The goal of the study was to evaluate the location of unexpected grade II gliomas remnants after assumed complete removal with intraoperative (iop) MRI and to assess the reason for their non-detection.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Little is known about the magnetic resonance imaging (MRI) appearance of canine meniscal lesions. The aim of this study is to describe the MR appearance of meniscal lesions in dogs with experimentally induced cranial cruciate ligament (CCL) deficiency. The pilot study revealed dogs weighing approximately 10 kg to be too small for meniscal evaluation on low-field MRI. In the main study, dogs weighing approximately 35 kg were used. The left CCL was transected and low-field MRI was performed regularly until 13 months post-surgery. Normal menisci were defined as grade 0. Intrameniscal lesions not reaching any surface corresponded to grade 1 if focal and to grade 2 if linear or diffuse. Grade 3 lesions consisted in linear tears penetrating a meniscal surface. Grade 4 lesions included complex signal changes or meniscal distortion. Between 2 and 13 months post-surgery, all dogs developed grade 4 lesions in the medial meniscus. Most of them corresponded to longitudinal or bucket handle tears on arthroscopy and necropsy. Two dogs showed grade 3 lesions reaching the tibial surface of the lateral meniscus on MRI but not in arthroscopy. Such tears are difficult to evaluate arthroscopically; MRI provides more accurate information about the tibial meniscal surface. Grades 1 and 2 lesions could not be differentiated from presumably normal menisci with our imaging technique. An MRI grading system better adapted to canine lesions has yet to be developed. MRI is a helpful tool for the diagnosis of complete tears in the canine meniscus, especially in larger dogs.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

These data form the basis of an analysis of a prevalent research bias in the field of ocean acidification, notably the ignoring of natural fluctuations and gradients in the experimental design. The data are extracted from published work and own experiments.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A method is presented for calculating the winding patterns required to design independent zonal and tesseral biplanar shim coils for magnetic resonance imaging. Streamline, target-field, Fourier integral and Fourier series methods are utilized. For both Fourier-based methods, the desired target field is specified on the surface of the conducting plates. For the Fourier series method it is possible to specify the target field at additional depths interior to the two conducting plates. The conducting plates are confined symmetrically in the xy plane with dimensions 2a x 2b, and are separated by 2d in the z direction. The specification of the target field is symmetric for the Fourier integral method, but can be over some asymmetric portion pa < x < qa and sb < y < tb of the coil dimensions (-1 < p < q < 1 and -1 < s < t < 1) for the Fourier series method. Arbitrary functions are used in the outer sections to ensure continuity of the magnetic field across the entire coil face. For the Fourier series case, the entire field is periodically extended as double half-range sine or cosine series. The resultant Fourier coefficients are substituted into the Fourier series and integral expressions for the internal and external magnetic fields, and stream functions on both the conducting surfaces. A contour plot of the stream function directly gives the required coil winding patterns. Spherical harmonic analysis of field calculations from a ZX shim coil indicates that example designs and theory are well matched.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper presents a finite-difference time-domain (FDTD) simulator for electromagnetic analysis and design applications in MRI. It is intended to be a complete FDTD model of an MRI system including all RF and low-frequency field generating units and electrical models of the patient. The pro-ram has been constructed in an object-oriented framework. The design procedure is detailed and the numerical solver has been verified against analytical solutions for simple cases and also applied to various field calculation problems. In particular, the simulator is demonstrated for inverse RF coil design, optimized source profile generation, and parallel imaging in high-frequency situations. The examples show new developments enabled by the simulator and demonstrate that the proposed FDTD framework can be used to analyze large-scale computational electromagnetic problems in modern MRI engineering. (C) 2004 Elsevier Inc. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In modern magnetic resonance imaging, both patients and health care workers are exposed to strong. non-uniform static magnetic fields inside and outside of the scanner. In which body movement may be able to induce electric currents in tissues which could be potentially harmful. This paper presents theoretical investigations into the spatial distribution of induced E-fields in a tissue-equivalent human model when moving at various positions around the magnet. The numerical calculations are based on an efficient. quasi-static, finite-difference scheme. Three-dimensional field profiles from an actively shielded 4 T magnet system are used and the body model projected through the field profile with normalized velocity. The simulation shows that it is possible to induce E-fields/currents near the level of physiological significance under some circumstances and provides insight into the spatial characteristics of the induced fields. The methodology presented herein can be extrapolated to very high field strengths for the evaluation of the effects of motion at a variety of field strengths and velocities. (C) 2004 Elsevier Ltd. All rights reserved.