997 resultados para Mode shapes
Resumo:
This paper presents a structural damage detection methodology based on genetic algorithms and dynamic parameters. Three chromosomes are used to codify an individual in the population. The first and second chromosomes locate and quantify damage, respectively. The third permits the self-adaptation of the genetic parameters. The natural frequencies and mode shapes are used to formulate the objective function. A numerical analysis was performed for several truss structures under different damage scenarios. The results have shown that the methodology can reliably identify damage scenarios using noisy measurements and that it results in only a few misidentified elements. (C) 2012 Civil-Comp Ltd and Elsevier Ltd. All rights reserved.
Resumo:
Among the experimental methods commonly used to define the behaviour of a full scale system, dynamic tests are the most complete and efficient procedures. A dynamic test is an experimental process, which would define a set of characteristic parameters of the dynamic behaviour of the system, such as natural frequencies of the structure, mode shapes and the corresponding modal damping values associated. An assessment of these modal characteristics can be used both to verify the theoretical assumptions of the project, to monitor the performance of the structural system during its operational use. The thesis is structured in the following chapters: The first introductive chapter recalls some basic notions of dynamics of structure, focusing the discussion on the problem of systems with multiply degrees of freedom (MDOF), which can represent a generic real system under study, when it is excited with harmonic force or in free vibration. The second chapter is entirely centred on to the problem of dynamic identification process of a structure, if it is subjected to an experimental test in forced vibrations. It first describes the construction of FRF through classical FFT of the recorded signal. A different method, also in the frequency domain, is subsequently introduced; it allows accurately to compute the FRF using the geometric characteristics of the ellipse that represents the direct input-output comparison. The two methods are compared and then the attention is focused on some advantages of the proposed methodology. The third chapter focuses on the study of real structures when they are subjected to experimental test, where the force is not known, like in an ambient or impact test. In this analysis we decided to use the CWT, which allows a simultaneous investigation in the time and frequency domain of a generic signal x(t). The CWT is first introduced to process free oscillations, with excellent results both in terms of frequencies, dampings and vibration modes. The application in the case of ambient vibrations defines accurate modal parameters of the system, although on the damping some important observations should be made. The fourth chapter is still on the problem of post processing data acquired after a vibration test, but this time through the application of discrete wavelet transform (DWT). In the first part the results obtained by the DWT are compared with those obtained by the application of CWT. Particular attention is given to the use of DWT as a tool for filtering the recorded signal, in fact in case of ambient vibrations the signals are often affected by the presence of a significant level of noise. The fifth chapter focuses on another important aspect of the identification process: the model updating. In this chapter, starting from the modal parameters obtained from some environmental vibration tests, performed by the University of Porto in 2008 and the University of Sheffild on the Humber Bridge in England, a FE model of the bridge is defined, in order to define what type of model is able to capture more accurately the real dynamic behaviour of the bridge. The sixth chapter outlines the necessary conclusions of the presented research. They concern the application of a method in the frequency domain in order to evaluate the modal parameters of a structure and its advantages, the advantages in applying a procedure based on the use of wavelet transforms in the process of identification in tests with unknown input and finally the problem of 3D modeling of systems with many degrees of freedom and with different types of uncertainty.
Resumo:
Experimental modal analysis techniques are applied to characterize the planar dynamic behavior of two spur planetary gears. Rotational and translational vibrations of the sun gear, carrier, and planet gears are measured. Experimentally obtained natural frequencies, mode shapes, and dynamic response are compared to the results from lumped-parameter and finite element models. Two qualitatively different classes of mode shapes in distinct frequency ranges are observed in the experiments and confirmed by the lumped-parameter model, which considers the accessory shafts and fixtures in the system to capture all of the natural frequencies and modes. The finite element model estimates the high-frequency modes that have significant tooth mesh deflection without considering the shafts and fixtures. The lumped-parameter and finite element models accurately predict the natural frequencies and modal properties established by experimentation. Rotational, translational, and planet mode types presented in published mathematical studies are confirmed experimentally. The number and types of modes in the low-frequency and high-frequency bands depend on the degrees of freedom in the central members and planet gears, respectively. The accuracy of natural frequency prediction is improved when the planet bearings have differing stiffnesses in the tangential and radial directions, consistent with the bearing load direction. (C) 2012 Elsevier Ltd. All rights reserved.
Resumo:
One of the challenges for structural engineers during design is considering how the structure will respond to crowd-induced dynamic loading. It has been shown that human occupants of a structure do not simply add mass to the system when considering the overall dynamic response of the system, but interact with it and may induce changes of the dynamic properties from those of the empty structure. This study presents an investigation into the human-structure interaction based on several crowd characteristics and their effect on the dynamic properties of an empty structure. The dynamic properties including frequency, damping, and mode shapes were estimated for a single test structure by means of experimental modal analysis techniques. The same techniques were utilized to estimate the dynamic properties when the test structure was occupied by a crowd with different combinations of size, posture, and distribution. The goal of this study is to isolate the occupant characteristics in order to determine the significance of each to be considered when designing new structures to avoid crowd serviceability issues. The results are presented and summarized based on the level of influence of each characteristic. The posture that produces the most significant effects based on the scope of this research is standing with bent knees with a maximum decrease in frequency of the first mode of the empty structure by 32 percent atthe highest mass ratio. The associated damping also increased 36 times the damping of the empty structure. In addition to the analysis of the experimental data, finite element models and a two degree-of-freedom model were created. These models were used to gain an understanding of the test structure, model a crowd as an equivalent mass, and also to develop a single degree-of-freedom (SDOF) model to best represent a crowd of occupants based on the experimental results. The SDOF models created had an averagefrequency of 5.0 Hz, within the range presented in existing biomechanics research, and combined SDOF systems of the test structure and crowd were able to reproduce the frequency and damping ratios associated with experimental tests. Results of this study confirmed the existence of human-structure interaction andthe inability to simply model a crowd as only additional mass. The two degree-offreedom model determined was able to predict the change in natural frequency and damping ratio for a structure occupied by multiple group sizes in a single posture. These results and model are the preliminary steps in the development of an appropriate methodfor modeling a crowd in combination with a more complex FE model of the empty structure.
Resumo:
Noise and vibration has long been sought to be reduced in major industries: automotive, aerospace and marine to name a few. Products must be tested and pass certain levels of federally regulated standards before entering the market. Vibration measurements are commonly acquired using accelerometers; however limitations of this method create a need for alternative solutions. Two methods for non-contact vibration measurements are compared: Laser Vibrometry, which directly measures the surface velocity of the aluminum plate, and Nearfield Acoustic Holography (NAH), which measures sound pressure in the nearfield, and using Green’s Functions, reconstructs the surface velocity at the plate. The surface velocity from each method is then used in modal analysis to determine the comparability of frequency, damping and mode shapes. Frequency and mode shapes are also compared to an FEA model. Laser Vibrometry is a proven, direct method for determining surface velocity and subsequently calculating modal analysis results. NAH is an effective method in locating noise sources, especially those that are not well separated spatially. Little work has been done in incorporating NAH into modal analysis.
Resumo:
Squeeze film damping effects naturally occur if structures are subjected to loading situations such that a very thin film of fluid is trapped within structural joints, interfaces, etc. An accurate estimate of squeeze film effects is important to predict the performance of dynamic structures. Starting from linear Reynolds equation which governs the fluid behavior coupled with structure domain which is modeled by Kirchhoff plate equation, the effects of nondimensional parameters on the damped natural frequencies are presented using boundary characteristic orthogonal functions. For this purpose, the nondimensional coupled partial differential equations are obtained using Rayleigh-Ritz method and the weak formulation, are solved using polynomial and sinusoidal boundary characteristic orthogonal functions for structure and fluid domain respectively. In order to implement present approach to the complex geometries, a two dimensional isoparametric coupled finite element is developed based on Reissner-Mindlin plate theory and linearized Reynolds equation. The coupling between fluid and structure is handled by considering the pressure forces and structural surface velocities on the boundaries. The effects of the driving parameters on the frequency response functions are investigated. As the next logical step, an analytical method for solution of squeeze film damping based upon Green’s function to the nonlinear Reynolds equation considering elastic plate is studied. This allows calculating modal damping and stiffness force rapidly for various boundary conditions. The nonlinear Reynolds equation is divided into multiple linear non-homogeneous Helmholtz equations, which then can be solvable using the presented approach. Approximate mode shapes of a rectangular elastic plate are used, enabling calculation of damping ratio and frequency shift as well as complex resistant pressure. Moreover, the theoretical results are correlated and compared with experimental results both in the literature and in-house experimental procedures including comparison against viscoelastic dampers.
Resumo:
This paper presents the Expectation Maximization algorithm (EM) applied to operational modal analysis of structures. The EM algorithm is a general-purpose method for maximum likelihood estimation (MLE) that in this work is used to estimate state space models. As it is well known, the MLE enjoys some optimal properties from a statistical point of view, which make it very attractive in practice. However, the EM algorithm has two main drawbacks: its slow convergence and the dependence of the solution on the initial values used. This paper proposes two different strategies to choose initial values for the EM algorithm when used for operational modal analysis: to begin with the parameters estimated by Stochastic Subspace Identification method (SSI) and to start using random points. The effectiveness of the proposed identification method has been evaluated through numerical simulation and measured vibration data in the context of a benchmark problem. Modal parameters (natural frequencies, damping ratios and mode shapes) of the benchmark structure have been estimated using SSI and the EM algorithm. On the whole, the results show that the application of the EM algorithm starting from the solution given by SSI is very useful to identify the vibration modes of a structure, discarding the spurious modes that appear in high order models and discovering other hidden modes. Similar results are obtained using random starting values, although this strategy allows us to analyze the solution of several starting points what overcome the dependence on the initial values used.
Resumo:
This paper presents a time-domain stochastic system identification method based on maximum likelihood estimation (MLE) with the expectation maximization (EM) algorithm. The effectiveness of this structural identification method is evaluated through numerical simulation in the context of the ASCE benchmark problem on structural health monitoring. The benchmark structure is a four-story, two-bay by two-bay steel-frame scale model structure built in the Earthquake Engineering Research Laboratory at the University of British Columbia, Canada. This paper focuses on Phase I of the analytical benchmark studies. A MATLAB-based finite element analysis code obtained from the IASC-ASCE SHM Task Group web site is used to calculate the dynamic response of the prototype structure. A number of 100 simulations have been made using this MATLAB-based finite element analysis code in order to evaluate the proposed identification method. There are several techniques to realize system identification. In this work, stochastic subspace identification (SSI)method has been used for comparison. SSI identification method is a well known method and computes accurate estimates of the modal parameters. The principles of the SSI identification method has been introduced in the paper and next the proposed MLE with EM algorithm has been explained in detail. The advantages of the proposed structural identification method can be summarized as follows: (i) the method is based on maximum likelihood, that implies minimum variance estimates; (ii) EM is a computational simpler estimation procedure than other optimization algorithms; (iii) estimate more parameters than SSI, and these estimates are accurate. On the contrary, the main disadvantages of the method are: (i) EM algorithm is an iterative procedure and it consumes time until convergence is reached; and (ii) this method needs starting values for the parameters. Modal parameters (eigenfrequencies, damping ratios and mode shapes) of the benchmark structure have been estimated using both the SSI method and the proposed MLE + EM method. The numerical results show that the proposed method identifies eigenfrequencies, damping ratios and mode shapes reasonably well even in the presence of 10% measurement noises. These modal parameters are more accurate than the SSI estimated modal parameters.
Resumo:
System identification deals with the problem of building mathematical models of dynamical systems based on observed data from the system" [1]. In the context of civil engineering, the system refers to a large scale structure such as a building, bridge, or an offshore structure, and identification mostly involves the determination of modal parameters (the natural frequencies, damping ratios, and mode shapes). This paper presents some modal identification results obtained using a state-of-the-art time domain system identification method (data-driven stochastic subspace algorithms [2]) applied to the output-only data measured in a steel arch bridge. First, a three dimensional finite element model was developed for the numerical analysis of the structure using ANSYS. Modal analysis was carried out and modal parameters were extracted in the frequency range of interest, 0-10 Hz. The results obtained from the finite element modal analysis were used to determine the location of the sensors. After that, ambient vibration tests were conducted during April 23-24, 2009. The response of the structure was measured using eight accelerometers. Two stations of three sensors were formed (triaxial stations). These sensors were held stationary for reference during the test. The two remaining sensors were placed at the different measurement points along the bridge deck, in which only vertical and transversal measurements were conducted (biaxial stations). Point estimate and interval estimate have been carried out in the state space model using these ambient vibration measurements. In the case of parametric models (like state space), the dynamic behaviour of a system is described using mathematical models. Then, mathematical relationships can be established between modal parameters and estimated point parameters (thus, it is common to use experimental modal analysis as a synonym for system identification). Stable modal parameters are found using a stabilization diagram. Furthermore, this paper proposes a method for assessing the precision of estimates of the parameters of state-space models (confidence interval). This approach employs the nonparametric bootstrap procedure [3] and is applied to subspace parameter estimation algorithm. Using bootstrap results, a plot similar to a stabilization diagram is developed. These graphics differentiate system modes from spurious noise modes for a given order system. Additionally, using the modal assurance criterion, the experimental modes obtained have been compared with those evaluated from a finite element analysis. A quite good agreement between numerical and experimental results is observed.
Resumo:
Computing the modal parameters of structural systems often requires processing data from multiple non-simultaneously recorded setups of sensors. These setups share some sensors in common, the so-called reference sensors, which are fixed for all measurements, while the other sensors change their position from one setup to the next. One possibility is to process the setups separately resulting in different modal parameter estimates for each setup. Then, the reference sensors are used to merge or glue the different parts of the mode shapes to obtain global mode shapes, while the natural frequencies and damping ratios are usually averaged. In this paper we present a new state space model that processes all setups at once. The result is that the global mode shapes are obtained automatically, and only a value for the natural frequency and damping ratio of each mode is estimated. We also investigate the estimation of this model using maximum likelihood and the Expectation Maximization algorithm, and apply this technique to simulated and measured data corresponding to different structures.
Resumo:
This paper presents a time-domain stochastic system identification method based on Maximum Likelihood Estimation and the Expectation Maximization algorithm. The effectiveness of this structural identification method is evaluated through numerical simulation in the context of the ASCE benchmark problem on structural health monitoring. Modal parameters (eigenfrequencies, damping ratios and mode shapes) of the benchmark structure have been estimated applying the proposed identification method to a set of 100 simulated cases. The numerical results show that the proposed method estimates all the modal parameters reasonably well in the presence of 30% measurement noise even. Finally, advantages and disadvantages of the method have been discussed.
Resumo:
Computing the modal parameters of large structures in Operational Modal Analysis often requires to process data from multiple non simultaneously recorded setups of sensors. These setups share some sensors in common, the so-called reference sensors that are fixed for all the measurements, while the other sensors are moved from one setup to the next. One possibility is to process the setups separately what result in different modal parameter estimates for each setup. Then the reference sensors are used to merge or glue the different parts of the mode shapes to obtain global modes, while the natural frequencies and damping ratios are usually averaged. In this paper we present a state space model that can be used to process all setups at once so the global mode shapes are obtained automatically and subsequently only a value for the natural frequency and damping ratio of each mode is computed. We also present how this model can be estimated using maximum likelihood and the Expectation Maximization algorithm. We apply this technique to real data measured at a footbridge.
Resumo:
Es conocido que la variación del comportamiento dinámico de las estructuras puede ser empleado dentro de un sistema de monitorización de su integridad estructural. Así, este estudio tiene como objetivo comprender el comportamiento dinámico de edificios esbeltos, frente a diferentes agentes ambientales como la temperatura y/o dirección y velocidad del viento. En el marco de esta investigación, se estudian dos edificios: la Torre de la ETSI (Escuela Técnica Superior de Ingenieros) de Caminos, Canales y Puertos de la UPM (Universidad Politécnica de Madrid) y un edificio de viviendas situado en la calle de Arturo Soria de Madrid. Los datos medioambientales antes mencionados, se registraron con sendas estacionales meteorológicas situadas en las azoteas de ambos edificios. Se realiza el análisis modal operacional de ambas estructuras. Este análisis se realiza a partir de las mediciones de las aceleraciones ante excitaciones ambientales, es un análisis basado sólo en la respuesta de la estructura. Por tanto, no es necesario interrumpir el funcionamiento en servicio de la instalación, obteniendo su comportamientos en este estado. A partir de este análisis, se obtienen las frecuencias naturales, los amortiguamientos modales y las formas modales. Así, en este trabajo se ha estudiado la relación existente entre la variación en la estimación de las frecuencias naturales y la variación de los agentes ambientales (fundamentalmente la temperatura). Los ensayos dinámicos en los dos edificios mencionados anteriormente, se han realizado utilizando acelerómetros de alta sensibilidad sincronizados inalámbricamente, lo cual ha simplificado el trabajo experimental si lo comparamos con los sistemas tradicionales. Como resultado del trabajo realizado se pueden destacar los siguientes puntos: (i) se ha visto que con el equipamiento disponible se pueden realizar análisis dinámicos de edificios, (ii) se ha mejorado el conocimiento dinámico de estas estructuras, y (iii) se ha visto la importancia que pueden tener los agentes ambientales dependiendo por un lado del tipo estructura del edificio. A partir del trabajo, se podrían actualizar modelos matemáticos que sirvan para la predicción de daños en las estructuras, y por otro, se podrán eliminar los efectos de los agentes ambientales, lo cual es un punto vital si se quiere emplear los parámetros modales para el cálculo de indices de daño. La aplicación de este tipo de investigación ayudará a tener una información mayor sobre el comportamiento de las estructuras y así, en el futuro, poder realizar distintos tipos de procesos, como la formulación de modelos matemáticos que reflejen con mayor fidelidad el comportamiento real. De esta forma, la monitorización de los agentes medioambientales permitirán valorar la influencia de estas variaciones sobre la estructura pudiéndose eliminar estos efectos. Con ello, se mejora la incertidumbre en la variación de frecuencias que puede ser utilizada como un sistema de activación de alarmas frente a la detección de daños estructurales. It is known that the variation of the dynamic behavior of structures can be used within a system to monitor structural integrity. So, this study aims to understand the dynamic behavior of slender buildings, against different environmental agents such as temperature and / or wind direction and velocity. As part of this investigation, two buildings are studied: the ETSI's (Escuela Técnica Superior de Ingenieros) main tower of Escuela de Caminos, Canales y Puertos of UPM (Universidad Politécnica de Madrid) and a residential building located in the streets Arturo Soria Madrid. The environmental data were recorded with weather stations located on the roof of both buildings. In both structures a modal operational analysis has been carried out. This analysis is performed from the measurements of the acceleration to the environmental excitation, this analysis is based only on the response of the structure. Therefore, it is not necessary to interrupt the operation of the structure, getting its behavior in this state. From this analysis, the natural frequencies, modal damping and mode shapes are obtained. So, in this work we have studied the existing relationship between the variation in the estimate of the natural frequencies and the variation of environmental agents (mainly temperature). The dynamic tests in the two buildings mentioned above, have been made using high-sensitivity accelerometers wirelessly synchronized, which has simplified the experimental work when compared to traditional systems. As a result of work performed can highlight the following points: (i) it has been found that with the available equipment can perform dynamic analysis of buildings, (ii) has improved dynamic knowledge of these structures, and, (iii) can be seen the potential importance of environmental agents depending on the type of building structure. From the work, mathematical models can be updated that serve to prediction of damage to structures, and on the other side, may eliminate the effects of environmental agents, which is a vital point if you want to use the modal parameters for calculating damage ratings. The application of this type of research will help to have more information about the behavior of structures and so, in the future, conduct various processes, as the formulation of mathematical models that reflect more accurately an actual behavior. In this way the monitoring of environmental agents will allow evaluate the influence of these variations on the structure being possible eliminate these effects. Thereby, improvement the uncertainty in the frequencies variation that can be used as an alarm activation system from detection of structural damage.
Resumo:
This paper presents a time-domain stochastic system identification method based on Maximum Likelihood Estimation and the Expectation Maximization algorithm that is applied to the estimation of modal parameters from system input and output data. The effectiveness of this structural identification method is evaluated through numerical simulation. Modal parameters (eigenfrequencies, damping ratios and mode shapes) of the simulated structure are estimated applying the proposed identification method to a set of 100 simulated cases. The numerical results show that the proposed method estimates the modal parameters with precision in the presence of 20% measurement noise even. Finally, advantages and disadvantages of the method have been discussed.
Resumo:
La influencia de un fluido en las características dinámicas de estructuras se ha estudiado desde hace tiempo. Sin embargo muchos estudios se refieren a aplicaciones bajo el agua, como es el caso del sonar de un submarino por lo que el fluido circundante se considera líquido (sin efectos de compresibilidad). Más recientemente en aplicaciones acústicas y espaciales tales como antenas o paneles muy ligeros, ha sido estudiada la influencia en las características dinámicas de una estructura rodeada por un fluido de baja densidad. Por ejemplo se ha mostrado que el efecto del aire en el transmisor-reflector del Intelsat VI C-B con un diámetro de 3,2 metros y con un peso de sólo 34,7 kg disminuye la primera frecuencia en torno a un 20% con respecto a su valor en vacío. Por tanto es importante en el desarrollo de estas grandes y ligeras estructuras disponer de un método con el que estimar el efecto del fluido circundante sobre las frecuencias naturales de éstas. De esta manera se puede evitar el ensayo de la estructura en una cámara de vacío que para el caso de una gran antena o panel puede ser difícil y costoso. Se ha desarrollado un método de elementos de contorno (BEM) para la determinación del efecto del fluido en las características dinámicas de una placa circular. Una vez calculados analíticamente los modos de vibración de la placa en vacío, la matriz de masa añadida debido a la carga del fluido se determina por el método de elementos de contorno. Este método utiliza anillos circulares de manera que el número de elementos para obtener unos resultados precisos es muy bajo. Se utiliza un procedimiento de iteración para el cálculo de las frecuencias naturales del acoplamiento fluido-estructura para el caso de fluido compresible. Los resultados del método se comparan con datos experimentales y otros modelos teóricos mostrando la precisión y exactitud para distintas condiciones de contorno de la placa. Por otro lado, a veces la geometría de la placa no es circular sino casi-circular y se ha desarrollado un método de perturbaciones para determinar la influencia de un fluido incompresible en las características dinámicas de placas casi-circulares. El método se aplica a placas con forma elíptica y pequeña excentricidad. Por una parte se obtienen las frecuencias naturales y los modos de deformación de la placa vibrando en vacío. A continuación, se calculan los coeficientes adimensionales de masa virtual añadida (factores NAVMI). Se presentan los resultados de estos factores y el efecto del fluido en las frecuencias naturales. ABSTRACT The influence of the surrounding fluid on the dynamic characteristics of structures has been well known for many years. However most of these works were more concerned with underwater applications, such as the sonar of a submarine and therefore the surrounding fluid was considered a liquid (negligible compressibility effects). Recently for acoustical and spatial applications such as antennas or very light panels the influence on the dynamic characteristics of a structure surrounded by a fluid of low density has been studied. Thus it has been shown that the air effect for the Intelsat VI C-B transmit reflector with a diameter of 3,2 meters and weighting only 34,7 kg decreases the first modal frequency by 20% with respect to the value in vacuum. It is important then, in the development of these light and large structures to have a method that estimates the effect that the surrounding fluid will have on the natural frequencies of the structure. In this way it can be avoided to test the structure in a vacuum chamber which for a large antenna or panel can be difficult and expensive A BEM method for the determination of the effect of the surrounding fluid on the dynamic characteristics of a circular plate has been developed. After the modes of the plate in vacuum are calculated in an analytical form, the added mass matrix due to the fluid loading is determined by a boundary element method. This method uses circular rings so the number of elements to obtain an accurate result is very low. An iteration procedure for the computation of the natural frequencies of the couple fluid-structure system is presented for the case of the compressibility effect of air. Comparisons of the present method with various experimental data and other theories show the efficiency and accuracy of the method for any support condition of the plate. On the other hand, sometimes the geometry of the plate is not circular but almost-circular, so a perturbation method is developed to determine the influence of an incompressible fluid on the dynamic characteristics of almost-circular plates. The method is applied to plates of elliptical shape with low eccentricity. First, the natural frequencies and the mode shapes of the plate vibrating in vacuum are obtained. Next, the nondimensional added virtual mass coefficients (NAVMI factors) are calculated. Results of this factors and the effect of the fluid on the natural frequencies are presented.